31A-331 16081664 Joist Calcs - Prelim 8-19-16diff ois 1 4 3/8" 2 16' 0 3/4" 5 1/2" 3 14' 6 3/4" 4 3/8" 31' 9 3/4" Graphical Illustration - Not To Scale Loading (psf):Quick Design Summary:Quick Deflection Summary: Live Load Deflection 0-03 @ 7-11-14 L/480Roof Live Load - 20 Building Code - IBC 2009 Total Load Deflection 0-04 @ 7-10-03 L/240Design Methodology - ASDRoof Dead Load - 10 Critical Moment (Pos)Passed - 63%Floor Live Load - 40 Critical Shear Passed - 51%Floor Dead Load - 15 Unbraced Length (Top/Bottom) - 0-00/16-00-12 Reactions: Maximum Analysis Reactions Support Start End Dead Floor Live Roof Live Snow 1 0-00 4-06 134.00 lb 400.00/-43.00 lb - - 2 16-05-02 16-10-10 391.00 lb 1043.00 lb - - 3 31-05-06 31-09-12 115.00 lb 370.00/-63.00 lb - - Forces: Maximum Load Magnitudes Type Start End Dead Floor Live Roof Live Snow Uniform 0-00 31-09-12 20.00 lb/ft 53.00 lb/ft - - Expanded Design Results: Design Control Result LDF Load Combination Critical Moment (Pos)2251.02 lb ft @ 16-07-14 3545.02 lb ft Passed - 63% 1.00 D + L Critical Shear 720.40 lb @ 16-05-01 1420.00 lb Passed - 51% 1.00 D + L Live Load Deflection 0-03 @ 7-11-14 L/480 Passed - L/935 - L Total Load Deflection 0-04 @ 7-10-03 L/240 Passed - L/726 - D + L Errors, Warnings & Notes: *The dead loads used in the design of this member were applied to the structure as sloped dead loads. *The member graphic, dimensions, and locations shown on this report are based on the centerline of the member. *Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting. Job ID: 16081664B Status: Design Passed Label: J1-16" O.C. Member Type: FloorJoist | Level: 2nd Floor Page: 1 of 2 Member: 1 -11 7/8" PJI-40 @ 16"Date: 08/19/2016 08:49:28 -Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices. -This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional. diff ois 1 2 17' 9 3/4"4 3/8" 18' 2 1/8" Graphical Illustration - Not To Scale Loading (psf):Quick Design Summary:Quick Deflection Summary: Live Load Deflection 0-06 @ 8-11-06 L/480Roof Live Load - 20 Building Code - IBC 2009 Total Load Deflection 0-08 @ 8-11-06 L/240Design Methodology - ASDRoof Dead Load - 10 Critical Moment (Pos)Passed - 83%Floor Live Load - 40 Critical Shear Passed - 46%Floor Dead Load - 15 Unbraced Length (Top/Bottom) - 0-00/17-09-12 Reactions: Maximum Analysis Reactions Support Start End Dead Floor Live Roof Live Snow 1 0-00 0-00 182.00 lb 485.00 lb - - 2 17-09-12 18-02-02 187.00 lb 497.00 lb - - Forces: Maximum Load Magnitudes Type Start End Dead Floor Live Roof Live Snow Uniform 0-00 18-02-02 20.00 lb/ft 53.00 lb/ft -- Connector Information: Nailing Requirements Support Manufacturer Model Top Face Member Min Seat Length Other Information 1 N/A N/A N/A N/A N/A N/A Connector has not been designed. No information is available. Expanded Design Results: Design Control Result LDF Load Combination Critical Moment (Pos)2933.35 lb ft @ 8-11-05 3545.02 lb ft Passed - 83% 1.00 D + L Critical Shear 655.53 lb @ 0-01 1420.00 lb Passed - 46% 1.00 D + L Live Load Deflection 0-06 @ 8-11-06 L/480 Passed - L/568 - L Total Load Deflection 0-08 @ 8-11-06 L/240 Passed - L/413 - D + L Design Notes: *The required bearing length for this member is the same for both with and without web stiffeners (112) Errors, Warnings & Notes: *The dead loads used in the design of this member were applied to the structure as sloped dead loads. *The member graphic, dimensions, and locations shown on this report are based on the centerline of the member. *Analysis and Design has been performed using precision loading from actual modeled conditions. Some loads may have been modified to simplify reporting. *Reinforcement Accessories are required. Refer to current manufacturer's product literature for installation details. Job ID: 16081664B Status: Design Passed Label: J3-16" O.C. Member Type: FloorJoist | Level: 2nd Floor Page: 2 of 2 Member: 1 -11 7/8" PJI-40 @ 16"Date: 08/19/2016 08:49:28 -Transfer reactions may differ from design results as allowed per building codes and standard load distribution practices. -This report is based on modeled conditions input by the user. Actual field conditions may differ from those shown. These results should be reviewed by a qualified design professional.