Loading...
24C-198 TRUSS 15102964B-Ghazey_Bates-rk-102415-DwgsOVERHANG INFO HEEL HEIGHT GABLE STUDS 00-04-03 24 IN. OC END CUT RETURN PLUMB NO REQ. ENGINEERING NONE REQ. LAYOUTS JOBSITE 1 QUOTE LAYOUT CUTTING BRT BRT DATEBY SHIP TO 24 West St Hatfield, MA 01038 R.K. Miles-HatfieldSOLD TO (413) 247-8300 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / / / / /ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # LMCWRKMI ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 15102964B Brian Tetreault Massachusetts / / / Andy Clogston ( ) - PAGE 1 SPECIAL INSTRUCTIONS: *10/18/15 plans. *12" heel height. *All flat ceilings. DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG: Ghazey-Bates /Rosemund BUILDING DEPARTMENT Roof Trusses JOB CATEGORY: Residential LOT # SUBDIV: DATE10/24/15 Northampton, MA Ghazey-Bates /Rosemund Andy Clogston 10/24/15 10/24/15 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5257 UFP Belchertown, LLC QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 40.0,10.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN T01 9.00 0.00 12-08-00 01-00-00 01-00-002 X 6 2 X 4 COMMON 3 12-08-00 T01GE 9.00 0.00 12-08-00 01-00-00 01-00-002 X 6 2 X 4 GABLE 1 12-08-00 T02 9.00 0.00 20-04-00 01-00-00 01-00-002 X 6 2 X 4 COMMON 1 20-04-00 T02SGE 9.00 0.00 20-04-00 01-00-00 01-00-002 X 6 2 X 4 GABLE 1 20-04-00 T03 9.00 0.00 30-00-00 01-00-00 01-00-002 X 6 2 X 4 COMMON 21 30-00-00 T03SGE 9.00 0.00 30-00-00 01-00-00 01-00-002 X 6 2 X 4 GABLE 2 30-00-00 T04 9.00 0.00 15-00-00 01-00-00 01-00-002 X 6 2 X 4 COMMON 6 15-00-00 T04GE 9.00 0.00 15-00-00 01-00-00 01-00-002 X 6 2 X 4 GABLE 1 15-00-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY: TITLE: ADDRESS: PHONE: DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL ConventionallyFramedConventionallyFramedTruss ListTruss Qty SpanT01 3 12' 8"T01GE 1 12' 8"T02 1 20' 4"T02SGE 1 20' 4"T03 21 30' 0"T03SGE 2 30' 0"T04 6 15' 0"T04GE 1 15' 0"Nailer trusses included.(Verify if wanted prior to order)BBO1BBO2BBO3BBO4T01GET02SGET03SGET03SGET04GET02T03(21)T04(6)T01(3)62' 0" 5' 0" 1' 0"44' 0" 12' 0" 62' 0" 12' 8" 7' 8" 9' 8"30' 0"15' 0"15' 0"30' 0"1' 11 1/4"2' 0" 11 1/4"1 1/2"10 1/2"1 1/2"1' 11 1/4"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 1' 11 1/4"1 1/2"1' 11 1/4"2' 0" 2' 0" 2' 0" Roof Area 2248.33Sheathing Count 77Overhang Lines 131Raked Lines 113.75Ridge Lines 67Hip Lines 0Valley Lines 0THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to beincorporated into the building design at the specificationof the building designer. See individual design sheets for eachtruss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracingof the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams,walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing ofwood trusses" available from the Truss Plate Institute, 583D'Onifrio Drive; Madison, WI 53179. It is the responsiblility of theGeneral Contractor/Superintendent to verify that the provided truss layout shall match the final intended construction plans,loading conditions, and use. If they do not, it is the responsiblility of the General Contractor/Superintendent to provideprints/plans containing the latest specifications and designs. Universal Forest Products will not be responsible forprint/planchanges by others after final approval ofshop drawings, norwill they be responsible for errors or modifications made on-siteduring construction. DO NOT CUT, NOTCH, DRILL, OR OTHERWISE"REPAIR" MANUFACTURED TRUSSES IN ANY WAYWITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. UFP WILL NOTBE HELD RESPONSIBLE FOR ANY MODIFICATIONS OR "CHARGE BACKS"DONE WITHOUT PRIOR WRITTENAUTHORIZATION FROM UFPGhazey-Bates/RosemundNorthampoton, MA10/24/15For Approval15102964BThe following information is anapproximate and NOT guaranteed Job 15102964B Truss T01 Truss Type COMMON Qty 3 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:48:53 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-nFkwqYdy??wfl9DBrkC58khXoUC0gWNd0ZXQ0JyQUT8 Scale = 1:32.7 T1 T1 B1 W2 W1 W1 1 2 3 4 5 8 7 6 9 10 3x10 MT20HS 3x10 MT20HS1.5x3 6x6 6-4-0 6-4-0 12-8-0 6-4-0 -1-0-01-0-0 6-4-06-4-0 12-8-06-4-0 13-8-01-0-0 1-0-05-9-06-0-141-0-09.00 12 Plate Offsets (X,Y)-- [6:0-5-0,0-0-12], [8:0-5-0,0-0-12] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.310.290.11 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.03-0.070.01 0.01 (loc)6-76-76 7-8 l/defl>999>999n/a >999 L/d240180n/a 360 PLATES MT20MT20HS Weight: 56 lb FT = 4% GRIP 197/144148/108 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x6 SPF No.2 *Except* W2: 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x8 SP No.1 1-10-4, Right 2x8 SP No.1 1-10-4 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS.(lb/size)8=855/0-5-8 (min. 0-1-8), 6=855/0-5-8 (min. 0-1-8) Max Horz8=-104(LC 6) Max Uplift8=-54(LC 8), 6=-54(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-9=-764/103, 3-9=-553/123, 3-10=-553/123, 4-10=-764/103, 2-8=-799/198, 4-6=-799/198BOT CHORD 7-8=0/448, 6-7=0/448 WEBS 3-7=0/268 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.33 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 8, 6. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T01GE Truss Type GABLE Qty 1 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:49:09 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-JKizB0p_EwxNgcRGn5Uro6LIWxksPlS_h2PGZOyQUSu Scale = 1:32.7 T1 T1 B1 W1 W1 ST3 ST2 ST1 ST2 ST1 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 6x6 3x8 3x8 12-8-0 12-8-0 -1-0-01-0-0 6-4-06-4-0 12-8-06-4-0 13-8-01-0-0 1-0-05-9-06-0-141-0-09.00 12 Plate Offsets (X,Y)-- [10:Edge,0-5-8] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix) 0.130.030.10 DEFL. Vert(LL)Vert(TL)Horz(TL) in-0.01-0.010.00 (loc)9910 l/defln/rn/rn/a L/d18080n/a PLATES MT20 Weight: 68 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x6 SPF No.2 *Except* W2: 2x4 SPF No.2 or 2x4 SPF Stud OTHERS 2x4 SPF No.2 or 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS.All bearings 12-8-0 except (jt=length) 16=-0-0-1 (input: 12-8-0), 10=-0-0-1 (input: 12-8-0), 13=-0-0-1 (input: 12-8-0), 14=-0-0-1 (input: 12-8-0), 15=-0-0-1 (input: 12-8-0), 12=-0-0-1 (input: 12-8-0), 11=-0-0-1 (input: 12-8-0). (lb) - Max Horz16=-104(LC 6)Max Uplift All uplift 100 lb or less at joint(s) 16, 10, 14, 15, 12, 11Max Grav All reactions 250 lb or less at joint(s) 13, 15, 11 except 16=279(LC 2), 10=279(LC 3), 14=304(LC 2), 12=304(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-16=-257/93, 8-10=-257/93 WEBS 4-14=-265/80, 6-12=-265/80 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard IndustryGable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x3 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.12) WARNING: Required bearing size at joint(s) 16, 10, 13, 14, 15, 12, 11 greater than input bearing size.13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 10, 14, 15,12, 11. 14) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T02 Truss Type Common Qty 1 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:49:36 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-1WqAsF8wtDLYPm?SsGTAOpzuLpoIEtSyulSB0JyQUST Scale: 1/4"=1' T1 T1 B1 W2 W1W1 HW1 HW1B1 1 2 3 4 5 6 7 8 9 10 19 20 4x10 4x4 6x6 5x8 2x4 2x4 4x10 4x4 10-2-0 10-2-0 20-4-0 10-2-0 -1-0-01-0-0 5-2-125-2-12 10-2-04-11-4 15-1-44-11-4 20-4-05-2-12 21-4-01-0-0 1-0-08-7-88-11-61-0-09.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [8:0-5-2,Edge], [10:0-4-0,0-3-0] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.280.660.40 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.12-0.300.04 0.01 (loc)10-1310-138 10-13 l/defl>999>803n/a >999 L/d240180n/a 360 PLATES MT20 Weight: 105 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 or 2x4 SPF Stud *Except* W2: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 1-11-12, Right 2x6 SPF No.2 1-11-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS.(lb/size)2=1320/0-5-8 (req. -0-0-1), 8=1320/0-5-8 (req. -0-0-1)Max Horz2=174(LC 7)Max Uplift2=-58(LC 8), 8=-58(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-787/0, 3-4=-1448/245, 4-19=-1136/214, 5-19=-984/236, 5-20=-984/236, 6-20=-1136/214, 6-7=-1448/245, 7-8=-787/0BOT CHORD 2-10=-161/1067, 8-10=-121/1067WEBS5-10=-137/665, 6-10=-440/181, 4-10=-440/181 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.332) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members.7) WARNING: Required bearing size at joint(s) 2, 8 greater than input bearing size. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T02SGE Truss Type GABLE Qty 1 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:50:06 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-8IeW9WVkpR7I?NIDcZ0Cb8C0mv1JGSuNoQjn4ayQUS? Scale: 1/4"=1' T1 T1 B1 W2 W1W1 HW1 HW1B1 ST2 ST1 ST2 ST3 ST1 ST4 ST5 ST6 1 2 3 4 5 6 7 8 9 10 33 34 4x10 4x4 6x6 5x8 2x4 2x4 4x10 4x4 2x4 2x4 3x6 3x6 10-2-0 10-2-0 20-4-0 10-2-0 -1-0-01-0-0 5-2-125-2-12 10-2-04-11-4 15-1-44-11-4 20-4-05-2-12 21-4-01-0-0 1-0-08-7-88-11-61-0-09.00 12 Plate Offsets (X,Y)-- [2:0-3-8,Edge], [8:0-5-2,Edge], [10:0-4-0,0-3-0] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.280.660.40 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.12-0.300.04 0.01 (loc)10-2710-278 10-27 l/defl>999>803n/a >999 L/d240180n/a 360 PLATES MT20 Weight: 130 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 or 2x4 SPF Stud *Except* W2: 2x4 SPF No.2 OTHERS 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 1-11-12, Right 2x6 SPF No.2 1-11-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 5-11-8 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS.(lb/size)2=1320/0-5-8 (min. 0-2-1), 8=1320/0-5-8 (min. 0-2-1)Max Horz2=-174(LC 6) Max Uplift2=-58(LC 8), 8=-58(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-787/0, 3-4=-1448/245, 4-33=-1136/214, 5-33=-984/236, 5-34=-984/236, 6-34=-1136/214, 6-7=-1448/245, 7-8=-787/0BOT CHORD 2-10=-161/1067, 8-10=-121/1067WEBS5-10=-137/665, 6-10=-440/181, 4-10=-440/181 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.332) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 4) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangsnon-concurrent with other live loads.6) All plates are 1.5x3 MT20 unless otherwise indicated. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 2, 8.11) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 12) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T03 Truss Type COMMON Qty 21 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:46:35 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-qiOltMyOVcXEByfglljkYezqus04KypJH566AJyQUVI Scale = 1:69.2 T2 T2 B1 W2 W1 W2 W1 HW1 HW1 T1 T1 B2 1 2 3 4 5 6 7 8 9 10 11 14 13 1223242526 27 28 5x6 6x6 5x6 4x10 4x4 3x10 MT20HS 4x4 2x4 4x4 2x4 4x10 4x4 10-1-3 10-1-3 19-10-13 9-9-11 30-0-0 10-1-3 -1-0-01-0-0 7-7-127-7-12 15-0-07-4-4 22-4-47-4-4 30-0-07-7-12 31-0-01-0-0 1-0-012-3-012-6-141-0-09.00 12 Plate Offsets (X,Y)-- [2:0-5-2,Edge], [10:0-5-2,Edge] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.800.650.64 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.34-0.530.07 0.03 (loc)12-1412-1410 14-17 l/defl>999>679n/a >999 L/d240180n/a 360 PLATES MT20MT20HS Weight: 157 lb FT = 4% GRIP 197/144148/108 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF 2100F 1.8EWEBS2x4 SPF No.2 *Except* W1: 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 1-11-12, Right 2x6 SPF No.2 1-11-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS.(lb/size)2=2203/0-5-8 (min. 0-3-7), 10=2203/0-5-8 (min. 0-3-7)Max Horz2=257(LC 7)Max Uplift2=-71(LC 8), 10=-71(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1356/9, 3-4=-2699/351, 4-5=-2465/432, 5-6=-2235/472, 6-7=-2235/472, 7-8=-2465/432, 8-9=-2699/351, 9-10=-1356/9BOT CHORD 2-23=-213/2009, 23-24=-120/2009, 14-24=-120/2009, 14-25=0/1381, 13-25=0/1381, 13-26=0/1381, 12-26=0/1381, 12-27=-120/2009, 27-28=-120/2009, 10-28=-165/2009WEBS6-12=-198/1168, 8-12=-694/301, 6-14=-198/1168, 4-14=-694/301 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.332) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.5) All plates are MT20 plates unless otherwise indicated. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 2 and 71 lb uplift at joint 10. 9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T03SGE Truss Type GABLE Qty 2 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:47:10 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-IR0_DKNLGMyGuKrOIbsxT0wp3zzP1nWTK14TunyQUUl Scale = 1:70.3 T2 T2 B1 W2 W1 W2 W1 HW1 HW1 T1 T1 B2 ST6 ST4 ST5 ST2 ST3 ST1 ST4 ST5 ST2 ST3 ST1 ST7 ST8 ST9 ST10 12 3 4 5 6 7 8 9 10 11 14 13 1247484950 51 52 5x6 10x12 5x6 4x10 4x4 3x10 MT20HS 4x4 2x4 4x4 2x4 4x10 4x4 4x10 4x10 3x4 4x10 4x10 4x10 10-1-3 10-1-3 19-10-13 9-9-11 30-0-0 10-1-3 -1-0-01-0-0 7-7-127-7-12 15-0-07-4-4 22-4-47-4-4 30-0-07-7-12 31-0-01-0-0 1-0-012-3-012-6-141-0-09.00 12 Plate Offsets (X,Y)-- [2:0-5-2,Edge], [6:0-7-8,0-4-0], [10:0-5-2,Edge] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.800.640.64 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.34-0.540.08 0.03 (loc)12-1412-1410 14-41 l/defl>999>667n/a >999 L/d240180n/a 360 PLATES MT20MT20HS Weight: 238 lb FT = 4% GRIP 197/144148/108 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF 2100F 1.8EWEBS2x4 SPF No.2 *Except* W1: 2x4 SPF No.2 or 2x4 SPF Stud OTHERS 2x4 SPF No.2 or 2x4 SPF Stud *Except* ST6: 2x4 SPF No.2 SLIDER Left 2x6 SPF No.2 1-11-12, Right 2x6 SPF No.2 1-11-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 2-9-3 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS.(lb/size)2=2189/0-5-8 (min. 0-3-7), 10=2189/0-5-8 (min. 0-3-7) Max Horz2=257(LC 7) Max Uplift2=-71(LC 8), 10=-71(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-1320/9, 3-4=-2686/351, 4-5=-2452/432, 5-6=-2222/472, 6-7=-2222/472, 7-8=-2452/432, 8-9=-2686/351, 9-10=-1320/9BOT CHORD 2-47=-213/1997, 47-48=-120/1997, 14-48=-120/1997, 14-49=0/1374, 13-49=0/1374, 13-50=0/1374, 12-50=0/1374, 12-51=-120/1997, 51-52=-120/1997, 10-52=-165/1997 WEBS 6-12=-198/1159, 8-12=-692/301, 6-14=-198/1159, 4-14=-692/301 NOTES-1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 6) All plates are MT20 plates unless otherwise indicated. 7) All plates are 1.5x3 MT20 unless otherwise indicated. 8) Gable studs spaced at 2-0-0 oc.9) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.10) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 71 lb uplift at joint 2 and 71 lb uplift at joint 10. 12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T04 Truss Type COMMON Qty 6 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:47:44 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-Jz3qMyngFoERzYRwIkTvrBKiwgbG?IRT8KJG5pyQUUD Scale = 1:37.6 T1 T1 B1 W2 W1 W11 2 3 4 5 8 7 6 9 10 11 12 4x10 4x10 1.5x3 6x6 7-6-0 7-6-0 15-0-0 7-6-0 -1-0-01-0-0 7-6-07-6-0 15-0-07-6-0 16-0-01-0-0 1-0-06-7-86-11-61-0-09.00 12 Plate Offsets (X,Y)-- [6:0-5-0,0-1-12], [8:0-5-0,0-1-12] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix-M) 0.460.520.16 DEFL. Vert(LL)Vert(TL)Horz(TL) Wind(LL) in-0.06-0.150.02 0.02 (loc)6-76-76 7-8 l/defl>999>999n/a >999 L/d240180n/a 360 PLATES MT20 Weight: 65 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x6 SPF No.2 *Except* W2: 2x4 SPF No.2 or 2x4 SPF Stud SLIDER Left 2x6 SPF No.2 1-11-12, Right 2x6 SPF No.2 1-11-12 BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS.(lb/size)8=1116/0-5-8 (min. 0-1-12), 6=1116/0-5-8 (min. 0-1-12) Max Horz8=-124(LC 6) Max Uplift8=-57(LC 8), 6=-57(LC 9) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-9=-1093/118, 3-9=-835/141, 3-10=-835/141, 4-10=-1093/118, 2-8=-1036/217, 4-6=-1036/217BOT CHORD 8-11=0/681, 7-11=0/681, 7-12=0/681, 6-12=0/681 WEBS 3-7=0/373 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.33 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1 3) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 57 lb uplift at joint 8 and 57 lb uplift at joint 6. 8) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.9) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard Job 15102964B Truss T04GE Truss Type GABLE Qty 1 Ply 1 Northampton, MA Job Reference (optional)7.610 s Jan 29 2015 MiTek Industries, Inc. Fri Oct 23 16:48:00 2015 Page 1 Universal Forest Products ID:whq6DFRwUiKlE_mhZ3?y7nyQUYY-r21tiQ_iUjFAu0f?E5lfVZ_Ww7BglXpqqpB6euyQUTz Scale = 1:37.6 T1 T1 B1 W1 W1 ST4 ST3 ST2 ST1 ST3 ST2 ST1 1 2 3 4 5 6 7 8 9 10 11 20 19 18 17 16 15 14 13 12 21 22 6x6 3x8 3x8 15-0-0 15-0-0 -1-0-01-0-0 7-6-07-6-0 15-0-07-6-0 16-0-01-0-0 1-0-06-7-86-11-61-0-09.00 12 Plate Offsets (X,Y)-- [12:Edge,0-5-8] LOADING (psf) TCLL(Roof Snow=40.0)TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACING- Plate Grip DOLLumber DOL Rep Stress Incr Code 2-0-01.151.15YES IRC2009/TPI2007 CSI. TCBCWB (Matrix) 0.130.030.13 DEFL. Vert(LL)Vert(TL)Horz(TL) in-0.01-0.010.00 (loc)111112 l/defln/rn/rn/a L/d18080n/a PLATES MT20 Weight: 84 lb FT = 4% GRIP 197/144 LUMBER- TOP CHORD 2x6 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x6 SPF No.2 *Except* W2: 2x4 SPF No.2 or 2x4 SPF Stud OTHERS 2x4 SPF No.2 or 2x4 SPF Stud BRACING- TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS.All bearings 15-0-0 except (jt=length) 20=-0-0-1 (input: 15-0-0), 12=-0-0-1 (input: 15-0-0), 16=-0-0-1 (input: 15-0-0), 17=-0-0-1 (input: 15-0-0), 18=-0-0-1 (input: 15-0-0), 19=-0-0-1 (input: 15-0-0), 15=-0-0-1 (input: 15-0-0), 14=-0-0-1 (input: 15-0-0), 13=-0-0-1 (input: 15-0-0). (lb) - Max Horz20=-124(LC 6)Max Uplift All uplift 100 lb or less at joint(s) 20, 12, 17, 18, 19, 15, 14, 13Max Grav All reactions 250 lb or less at joint(s) 16, 19, 13 except 20=304(LC 12), 12=304(LC 12), 17=311(LC 2),18=262(LC 2), 15=311(LC 3), 14=262(LC 3) FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-20=-286/84, 10-12=-286/55 WEBS 5-17=-272/73, 7-15=-272/73 NOTES- 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.33 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard IndustryGable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads. 6) All plates are 1.5x3 MT20 unless otherwise indicated.7) Gable requires continuous bottom chord bearing. 8) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).9) Gable studs spaced at 2-0-0 oc. 10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.12) WARNING: Required bearing size at joint(s) 20, 12, 16, 17, 18, 19, 15, 14, 13 greater than input bearing size.13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 20, 12, 17, 18,19, 15, 14, 13. 14) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 15) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. LOAD CASE(S)Standard