24C-198 HERS-548 86 Massasoit St TBCENERGY STAR Qualified Homes Thermal Bypass Inspection Checklist City: KIC'ir-I^ACLlnfjcK Slate:///? Corrections 'I Builder I Rater I Needed Home Address: Thermal Bypass Inspection Guidelines Builder Verified Rater Verified 1, Overall Air Barrier and Thermal Barrier Alignment Requirements; Insulation shall be installed in full contact with sealed interior and exterior air barrier except (or alternate to interior air tsarrier urtder item no, 2 (Walls Adjoining Exterior Walls or Unconditioned Spaces) All Climate Zones: 1.1 Overall Alig 1.2 Garage Band nment Throughout Home—^ ^{f^ol^Q^ Cl2,(l,')C^ nd Joist Air Barrier (at bays adjoining conditioned space) 1.3 Attic Eave Baffles Where Vents/Leakage Exist • • • • • • Only at Climate Zones 4 and Higher: 1.4 Slab-edge Insulation (A maximum25% of the slab edge may be uninsulated in Climate Zones 4jMwi-S^ Best Practices Encourag^ IMot Req'd • • • 1.5 Air Barrier At All Band Joists (Climafe Zones'} and higher) 1.6 Minimize Thermal Bridging (e.g., OVE framing, SIPs, ICFs) • • • • • • • • 2. Walls Adjoining Exterior Walls or Unconditioned Spaces Requirement: • Fully insulated v/all aligned with air barrier at both interior and exterior, OR • Alternate for Climate Zones 1 thru 3, sealed exterior air barrier aligned with RESNET Grade 1 insulation fully supported • Continuous top and bottom plates or sealed blocking 2.1 Wall Behind Shower/Tub 2.2 Wall Behind Fireplace 2.3 Insulated Attic SlopesAWalls 2.4 Attic Knee Walls 2.5 Skylight Shaft Walls 2.6 Wall Adjoining Porch Roof 2.7 Staircase Walls 2.8 Double Walls • • • • • • • • • • • • • • • • • • • • s • 3. Floors betv««en Conditioned and Exterior Spaces Requirements: • Air barrier is installed at any exposed fibrous insulation edges • Insulation is installed to maintain permanent contact with sub-floor above including necessary supports (e.g., staves for blankets, netting for blown-in) • Blanket insulation is verified to have no gaps^ voids or compression. » Blown-in insulation is verified to have proper density with firm packing 3.1 Insulated Floor Above Garage 3.2 Cantilevered Floor • • • • Shafts Requirements: Openings to unconditioned space are fully sealed with solid blocking or flashing and any remaining gaps are sealed v^th caulk or foam (provide fire-rated collars and caulking wtiere required) 4.1 Duct Shaft 4.2 Piping Shaft/Penetrations 4.3 Flue Shaft • • • • EZ 0^ • 5: • • 5. Attic/ Ceiling Interface Requirements: ^—"-^ • All attic penetrations and dropped ceilings include a full interior air barrier aligned with insulation with any gaps fully sealed with caulk, foam or tape « fVlovable insulation fits snugly in opening and air barrier is fully gasketed 5 1 Attic Access Panel (fully gasketed and insulated) 5.2 Attic Drop-down Stair (fully gasketed and insulated) 5.3 Dropped Ceiling/Soffit (full sir barrier aligned with insulation) 5.4 Recessed Lighting Fixtures (ICAT labeled and sealed to drywall) 5.5 Whole-house Fan (insulated cover gasketed to the opening) • • • • • • • • • • • • • • Common Walls Between Dwelling Units Requirements: Gap between dr/v/all shaft wall (i.e., common wall) and the structural framing between units is fully sealed at all exterior boundary conditions 6.1 Common Wall Between Dwelling Units • • • Home Energy Rating Provider: Home Energy Rater Compa Home Energy Rater Signature Rater Inspection Date: ^0/ ny Name: foiiifrjLf^ (}v^Jni^^ Company Nan ire: 6J:^\_ ^ i Builder Inspection D,ate: Builder Employee Signature: