Loading...
23A-070 mech Bathroom-shower EXH FAN-MARC C. - SubmittalSound Power by Octave Band Sound Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones Inlet 68 74 69 61 60 57 52 46 66 55 7.4 Reference assembly view drawings for actual dimensions with mounted accessories *Overall height may be greater depending on motor * 17 21.75 4 14.63 1.75 Model: G-080-D Direct Drive Centrifugal Roof Exhaust Fan Dimensional Quantity 1 Weight w/o Acc's (lb)17 Weight w/ Acc's (lb)36 Optional Damper (in.)10 x 10 Roof Opening (in.)12.5 x 12.5 Performance Requested Volume (CFM)300 Actual Volume (CFM)306 External SP (in. wg)0.375 Total SP (in. wg)0.389 Fan RPM 1550 Operating Power (hp)0.06 Elevation (ft)180 Airstream Temp.(F)70 Air Density (ft3)0.075 Tip Speed (ft/min)4,413 Static Eff. (%)34 Motor Motor Mounted Yes Size (hp)1/20 V/C/P 115/60/1 Enclosure ODP Motor RPM 1550 Windings 1 NEC FLA* (Amps)NA External SP 0.375 in. wg Direct Drive RPM Adjustment 0.014 in. wg Total SP 0.389 in. wg Notes: All dimensions shown are in units of in.. *FLA - based on tables 150 or 148 of National Electrical Code 2002. Actual motor FLA may vary, for sizing thermal overload, consult factory. LwA - A weighted sound power level, based on ANSI S1.4dBA - A weighed sound pressure level, based on 11.5 dB attenuation per Octave band at 5.0 ft - dBA levels are not licensed by AMCA International Sones - calculated using AMCA 301 at 5.0 ft 10/3/2013Printed Date: REPLACEMENT FAN-MARC C.Job: Mark 1Mark: CAPS 4.12.1250 R:\Job Files\Greenheck CAPS\2013\Bob Yeterian\REPLACEMENT FAN-MARC C..gfcj Page 1 of 4 Model: G-080-D Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: - Aluminum housing - Backward inclined wheel - Aluminum curb cap with prepunched mounting holes - Birdscreen - Ball bearing motors (sizes 100-180), sleeve bearing motors (sizes 60-95) - Motor isolated on shock mounts - Corrosion resistant fasteners. Options & Accessories: UL/cUL 705 Listed - "Power Ventilators" Switch, NEMA-1, Toggle, Ship With Unit, Field Mounted Roof Curb, GPI-17-G12, Under Sized 1 in. Total Damper, WD-100-PB-10X10, Gravity Operated (Loose), Not Coated 10/3/2013Printed Date: REPLACEMENT FAN-MARC C.Job: Mark 1Mark: CAPS 4.12.1250 R:\Job Files\Greenheck CAPS\2013\Bob Yeterian\REPLACEMENT FAN-MARC C..gfcj Page 2 of 4 DAMPER TYP. SECTION VIEW 1010 2.5 6.6 Standard Construction Features: - Model WD-100 is a horizontal mount exhaust damper (air flow up) and is constructed of 18 ga galvanized steel with pre- punched mounting holes - Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge, and spring assisted for ease of opening - Steel axles are 0.188 in. diameter zinc plated mounted in acetal bushings - Synthetic axle bearings Damper Configuration: Actuator Type:Gravity End Switch:No Notes: All dimensions shown are in units of in. Width And height furnished approximately 0.125 in. undersize Horizontal Mount Exhaust Damper Model:WD-100 10/3/2013Printed Date: REPLACEMENT FAN-MARC C.Job: Mark 1Mark: CAPS 4.12.1250 R:\Job Files\Greenheck CAPS\2013\Bob Yeterian\REPLACEMENT FAN-MARC C..gfcj Page 3 of 4 Actual L Actual W 1.75 Height Flange W Flange L GPI Roof Curb STANDARD CONSTRUCTION FEATURES • Welded Aluminum (0.064 in.) or galvanized (18 ga) construction • Straight sided • 2 in. roof mounting flange • 1 in. 3# density insulation • Wood nailer. Roof Opening - The Maximum roof opening dimension should not be greater than the "Actual" top outside dimension minus 2 in.. With dampers, the Minimum roof opening dimension should be at least 2.5 in. more than the damper dimension. NOTES: * The Roof Opening Dimension may NOT be the Structural Opening Dimension. * Maximum single piece shipping length is 76". * Security Bars are optional and must be specified. Frames and gridwork are all 10 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. To prevent corrosion, they are coated with Greenheck's high performance Permatector coating. NOTES: All dimensions shown are in units of inches Mark Qty.Cap W x L Actual W x L Flange W x L Height Damper Tray W x L Mark 1 1 17 x 17 16 x 16 20 x 20 12 10/3/2013Printed Date: REPLACEMENT FAN-MARC C.Job: CAPS 4.12.1250 R:\Job Files\Greenheck CAPS\2013\Bob Yeterian\REPLACEMENT FAN-MARC C..gfcj Page 4 of 4