23A-070 70 Main Sprinkler Alarm NarrativeWAREHOUSE MECHANICAL CONTRACTORS, INC .. A certified Service Disabled Veteran Owned Small Business Sprinkler Contractors and Designers Established 1980 Fire Sprinkler portion of Narrative Report Northampton Health Center 70 Main Street Florence, MA. By Installing Contractor Warehouse Mechanical Contractors, Inc. MA. Sprinkler Contractors License SC 2254 Expires 11/2312013 413-536-9222 Phone 413-535-2486 Fax June 12, 2013 342 Britton Street -Chicopee, MA. 01020 Tel. (413) 536-9222 FAX (413) 535-2486 MA.Lic.2254 &R1. 329 FIRE PROTECTION SYSTEMS NARATIVE REPORT BASIS (METHODOLOGY) OF DESIGN Section 1 -Building Description a. Building "Use Group: The Building use is Business (B) b. Type(s) of occupancies (hazards within the building): Medical Offices c. One story above grade high point of building roof is 14'-0" +/­ d. Zero stories below grade e. The existing building is 13,540 SF, the new addition is 4,780 SF for a total of 18,320 sf f. Storage: In accordance with NFPA-13 for miscellaneous storage under 12'-0" in height The highest sprinkler flow requirement is .10 GPM over the most remote 900 square feet which will require approximately 121 GPM @ 41.9 PSI at the base of the riser and 221 GPM@43 PSI at the connection to the city main Water flow test is 66 PSI Static, 57 PSI Residual with 520 GPM flowing Section 2 -Applicable Laws, Regulations and Standards a. 780 CMR code sections "Fire Protection System Requirements" 903.2.0 Fire Suppression Systems 903.4.2 Requires audio visual alarm devices 903.4.1 Monitoring b. NFP A Standards and Editions used for the design of each specific fire protection system, NFPA 13, 2007; NFPA 72,2007; NFPA 24,2007 Section 3 -Design Responsibility for the Fire Protection Systems Warehouse Mechanical Contractors, Inc. develops a full system layout, design criteria and calculations and certifies the system installation for code compliance at completion. Section 4 -Fire Protection Systems to be installed a. Water supply will be taken from the existing 4" water service that is connected to the city main in South Street b. Sprinkler systems and components c. Fire alarm systems and components-audio and visual appliances installed throughout in accordance with NFP A 72. d. Manual suppression systems are not required e. Seismic provided in accordance with NFPA 13 f. Stortz fire department connection provided in accordance with the Northampton Fire Department All of the above items are required by regulations (780 CMR) all systems are new 901.2.1(1.a.ii) Sequence of Operation Section 1 Wet sprinkler system: System operates automatically upon the fusing of a single fire sprinkler. Operational Sequence: a. Wet system operates automatically on water flow from a single sprinkler. Closed contacts on the flow switch will provide alarm contact for the fire control panel and activate the local audible visual panels. 901.2.1(1.a.iii) Testing Criteria Section 1-Testing Criteria in accordance with NFPA 13 System piping: 1. Hydrostatically test wet system piping at a pressure of 200 psi for two hours without a loss of pressure 2. Conduct a full forward flow test of the backflow preventer at a rate of 121 GPM thru the 2" main drain 3. A 2" main drain test shall be conducted. Record static and residual pressures on the test certificates 4. Conduct system operational and alarm test on the system from the inspector's test connection in accordance with NFPA 13 5. Central station must receive the alarm and trouble signals Warehouse Mechanical is in charge of setting up and conducting the testing. Warehouse Mechanical will provide test certificates Section 2-Equipment and Tools a. Manufacturer's instructions b. Approved narrative report, sequence of operations section c. Flow measuring devices-pitot tube for backflow preventer full forward flow test d. Gauges-main riser for 2" drain and hydrostatic testing e. Fire hose is required to direct backflow flushing Section 3-Approval Requirements a. Certification from Warehouse Mechanical Contractors, Inc. stating that the fire protection,sprinkler system has been installed in accordance with the approved fire protection construction documents and that he has reviewed the as-built drawings for conformance to 780 CMR 901.7.4 and has identified deviations if any, from the approved fire protection construction documents. b. Confirmation by the building owner/developer or authorized representative that they have received the as-built sprinkler system shop drawings from the installing contractor c. Material Test, Performance and Completion Certificates, properly executed by the installing contractor in accordance with the applicable NFPA Standards. d. Satisfactory functional test of all fire protection systems witnessed by the Building official and the head of the fire department or their designees. Industrial Residential Security, LLC 73 GunnRoad Southampton, MA 01073 413-527-3353 Fire Alarm Narrative: 6-17-2013 Location: Valley Medical 70 Main Street Florence MA 01062 Building: Usage Group: B commercial Installing Company: Industrial Residential Security, LLC 73 GunnRoad Southampton, MA 01073 Fire Alarm System: The Fire Alarm System is a Silent Knight addressable control. The SLC Loop is class A. The Notification Loop is a SLC class A or class B. (Key in Knox box to enable -operation). The procedure to reset and or silence the alarm, is to push the silence and or reset button then push in the code (1111). Fire Alarm Monitoring: The Fire Alarm System will be monitored at C.O.P.S. Monitoring in NJ. Irsco shall program all alarms, troubles and supervisory. It shall dial thru the built in digital dialer to the central station. Proper notifications to the Fire Dept. and responsible parties shall be made upon receiving the signals. Fire System: 1 Silent Knight 5808 addressable control with transformer, batteries 1 SK 5860 LCD annuciator 1 Outdoor red Beacon 11 Outdoor Knox Box 1 SK 500AIM module sprinkler water flow 3 SK 500 AIM modules sprinkler tampers 3 SK SD 505 DCTR duct smokes with remotes plates 7 SK SD 500 PSDA dual pull stations 1 SK SD 505 APS photo smoke above control 8 SK SD 505 APS photo smokes 10 System Sensor Strobes SR in bathrooms and Xray room 14 System Sensor P2r Hom strobes through out