Loading...
32A-124 130822-A2Z For Construction Set-2013-09-2322 August 2013 FOR CONSTRUCTION LIST OF DRAWINGS SITE L1 SITE PLAN STRUCTURAL S0 STRUCTURAL GENERAL NOTES & DETAILS S1 FRAMING PLANS ARCHITECTURAL A1.1 LOWER & UPPER LEVEL FLOOR PLANS A1.2 ROOF PLAN A2.1 REFLECTED CEILING PLANS A3.1 ELEVATIONS A3.2 ELEVATION & BUILDNG SECTION A4.1 BUILDING SECTIONS A5.1 WALL SECTIONS A5.2 WALL SECTIONS & EXTERIOR DETAILS A5.3 AIR SEALING SCHEMATIC & DETAILS (to follow) A7.1 INTERIOR ELEVATIONS, DETAILS & FINISH SCHEDULE A9.1 WINDOW & DOOR SCHEDULE & DETAILS MECHANICAL MV1 MECHANICAL & VENTILATION PLANS ELECTRICAL & LIGHTING E1 POWER PLAN E2.1 LIGHTING PLAN & LIGHTING SCHEDULE FIRE PROTECTION FP1 FIRE PROTECTION PLANS FP2 FIRE PROTECTION SECTION Client Area: Username: atwoz (lower case) Password: addition (lower case) CONSTRUCTION MANAGEMENT Cody Construction Belchertown, MA 413-345-0201 Project Manager: Dave Cody OWNERS Jack & Priscilla Finn 57 King Street Northampton, MA 01060 OWNER'S CONSULTANT Tina La Londe Interior Design Amherst, MA 01002 413.253.3854 ARCHITECT Coldham&Hartman Architects 49 South Pleasant St, Suite 301 Amherst, MA 01002 413.549.3616 Project Architect: Bruce Coldham, FAIA Project Manager: Samantha Wood A2Z ADDITION 57 KING STREET, NORTHAMPTON, MA ARCHITECT'S CONSULTANTS Ryan S. Helwig, PE Structural Engineering Northampton, MA 01060 413.584.4594 Rybak Engineering, Inc. Fire Protection Engineering Warren, MA 01083 413.436.5500 Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 SITE PLAN L1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n PROPOSED ADDITION ELEV. = 1 3 3. 3 1 FINISH E D F L O O R ELEV. = 131.81FINISHE D FL O O R ELEV. = 131.80FINIS H E D FL O O R ELEV. = 1 3 2. 2 9 FINISH E D FLOOR ELEV. = 1 3 1. 7 5 FINISH E D F L O O R THE NORTHAMPTON CO-OPERATIVE BANK BOOK 1294, PAGE 149 PLAN BOOK 33, PAGE 54 DENIS PERLMAN BOOK 4451, PAGE 292 N/F BOSTON & MAINE CORPORATION N/F HAMPSHIRE COUNTY BOOK 1664, PAGE 336 PLAN BOOK 83, PAGE 95 THE INHABITANTS OF 131.69132.23 132.63 133.29 132.53 132.21 132.10130.57131.4 8 132.24 131.67 132.53 132.18 132.06 131.68131.61131.88130.86131.71131.23129.11129.4 3 129.13 131.18 131.11131.58132.3 9 131.18131.27130.89130.36132.91 132.68 132.60132.61132.41132.47132.0313 2 13 1 132 1 3 3 132 132 132131 1301 3 1 133132 1301 3 1 135138KING STREETA 1987 ALTERAT ION ~ VAR IABLE W IDTH EXIST.PLANTBEDEXIST.PLANT BED STORE E N T R A N C E CENTERLINE OF EXIST. ENT.129.675678910123456789131.63130.72132.08133 .094.34 'S 34 °48 '01 " E S 53°5 3' 1 7 " W 1 5 2. 9 0'26.62 'S 34 °49 '39 " E37.58'S44°28'59" W S 40°24'20" W 159.78'S 30 °28 '47 " E 61 .12 ' N 43°00'40" E 201.67' N 43°33'10" E N 53°2 5' 1 0" E 1 2 6. 5 1'N 35 °50 '22 " W 91 . 15 '27.50'SEE PLAN BOOK 147 , PAGE 42PARCEL AREA = 26,781 S.F.±SCALE: 1" = 20'1 SITE PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 STRUCTURAL GENERAL NOTES & DETAILS S0 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 8"1'-2"4"6"4"9"9" (3) #4 BARS TOP & BOTTOM ELEVATOR PIT 2013%07%30'' ' S Structural Dwg Notes.docx' ' {Note: When PDF’ing - use custom paper size 5”x36”}' ' ' ' GENERAL NOTES 1. Dimensions are to face of framing unless noted otherwise. ' WALL STUDS ' 3-5/8” x 1-5/8” x 16 Ga @ 16” o/c' ' HEADER SCHEDULE (2) 3-5/8” x 1-5/8” x 16 Ga for Openings 4 ft and under. (2) 6” x 1-5/8” x 16 Ga for Openings over 4 ft. Headers to be placed back-to-back, or in a box configuration. Box headers deeper than 4” to have web stiffeners. Provide 3-5/8” x 1-5/8” x 16 Ga Ganged Studs @ Ends of Headers as follows: For Openings 4 ft and under provide two studs – 1 King + 1 Jack For Openings over 4 ft provide three studs – 1 King + 2 Jacks ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' ' STRUCTURAL DESIGN CRITERIA Floor Live Load: 40 psf Residential Snow: Ground Snow Load = 55 psf Temperature Factor Ct= 1.1 Roof Snow Load: 42 psf Width of Upper Roof Wbu = 25 ft. Drift Height Hdu = 2 ft. Drift Load = 40 psf Maximum REINFORCED CONCRETE 1. Reinforcing bars shall conform to ASTM A615, Grade 60, new billet steel. 2. Welded Wire Reinforcement(WWR) shall conform to ASTM A185. 3. Horizontal reinforcing shall be continuous in walls; lap bars 48 diameters; provide 90 degree corner bars. CONCRETE CLASS f'C W/C SLUMP ENTRAINED AIR Foundations 3000 0.5 4 inches 6% maximum Slabs 4000 0.45 4 inches none STRUCTURAL STEEL 1. Hollow Structural Sections (HSS): ASTM A500, Grade B. 2. Hooked Anchor rods: ASTM F1554 Grade 36. 3. Standard bolts: ASTM A307 4. Provide shop primer and field paint on all areas of steel which are to be embedded in concrete. COLD-FORMED METAL FRAMING 1. Steel framing material: ASTM A1003, with G90 zinc coating, of grade as follows: 50 ksi for of 16 gauge and heavier, 33 ksi for 18 gauge and lighter 2. Studs shall have pre-punched web knockouts and 1-⅝" minimum width flanges having ½" minimum return lips. Provide bracing and bridging per manufacturer’s instructions. 3. Steel track shall be manufacturer’s standard U-shaped track, with unpunched webs, unstiffened flanges, a minimum thickness matching wall studs and a minimum flange width of 2 inches. Studs shall be fully seated in track. 4. Header members shall have 1-⅝" minimum width flanges having ½" minimum return lips, and shall not have pre- punched web knockouts within 12 inches of supports. DIMENSION LUMBER 1. Dimension Lumber of 2 inch nominal thickness shall be Spruce-Pine-Fir #1/#2 per The National Lumber Grades Authority (NLGA) 2. Dimension Lumber for exposed framing shall be Southern Pine #1 or better per The Southern Pine Inspection Bureau - SPIB 3. All lumber exposed to weather or in contact with the ground, concrete or masonry shall be preservatively pressure- treated to the requirements of the American Wood Preservers Association (AWPA). 4. All anchor bolts, expansion anchors, joist hangers, seismic holdowns and hurricane anchors shall be galvanized. ENGINEERED LUMBER 1. LVL (Laminated Veneer Lumber) for Beams shall be manufactured with the following minimum design values: E = 2,000,000 psi & Fb = 3100 psi 2. LVL (Laminated Veneer Lumber) for Columns shall be manufactured with the following minimum design values: E = 1,700,000 psi & Fc = 3000 psi 3. PSL (Parallel Strand Lumber) shall be manufactured with the following minimum design values: E = 1,800,000 psi & Fc = 2500 psi 4. Wood I-joists shall have solid webs and 2 inch minimum width flanges, and shall be installed with web-stiffeners at all bearing locations. SCALE: 1" = 1'-0"1 HAUNCHED SLAB DETAIL Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 FRAMING PLANS S1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n UP1 A4.1 1 A4.1 2 A4.1 2 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 2 A3.2 2 A3.2 POST, SEE ABOVE PROVIDE BLOCKING FOR WALL MOUNTED AIR SOURCE HEAT PUMP COMPRESSOR/ CONDENSER UNIT POST, SEE ABOVE POST, SEE ABOVEPOST, SEE ABOVE WINDOW HEADER DOOR HEADER HEADER DOOR HEADER WINDOW HEADER 2X8 SPF ROOF RAFTER UNDER ROOF MEMBRANE, @ 24" O.C., SLOPE 3/4:12 (2) 2X6 DROPPED BEAM POST, SEE ABOVEPOST, SEE ABOVE DN1 A4.1 1 A4.1 2 A4.1 2 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 2 A3.2 2 A3.2 LOAD BEARING WALL INSIDE EXTERIOR WALL BELOW LOAD BEARING WALL INSIDE EXTERIOR WALL BELOWLOAD BEARING WALL INSIDE EXTERIOR WALL BELOW EXTERIOR OF GARAGE WALL FRAMING BELOW 4X4 POSTS4X4 POSTS NOTE: DOUBLE JOISTS EITHER SIDE OF RAILING POST LOCATIONS THEN SPACE TWO SINGLE JOISTS EQUALLY BETWEEN DOUBLE JOISTS, SEE DETAIL 3/A3.1 FOR MORE INFO 4X6 PSL/LVL HSS 4X4X1/4 TUBE STEEL GALV. STL. POSTGALV. STL. POST GALV. STL. POST (2) 2X4 ONE KING & ONE JACK POST HSS 4X4X1/4 TUBE STEEL DECK JOISTS SUPPORTED BY LEDGER, SEE DETAIL 2/A5.1 HEADER HEADER (2) 2X8 DROPPED BEAM 4(1.75" X 24") LVL DROPPED BEAM 9 1/2" ENGINEERED I-JOISTS, @ 16" O.C.2X10 PT DECK JOISTS OVER ROOF MEMBRANE, @ 16" O.C. 9 1/2" ENGINEERED I-JOISTS, @ 16" O.C. (3) 2X10 DROPPED BEAM (3) 2X4 ONE KING & ONE JACK EACH SIDE (3) 2X4 ONE KING & ONE JACK EACH SIDE 1.75"X9.5" LVL 1.75"X9.5" LVL36'-0" 103/4"23'-0"6'-10"5'-63/8"23'-75/8"1'-23/4"103/4"8'-31/4"8"1'-23/4"3'-0"103/4"1'-13/8"4'-8"3'-0"6'-93/4"4'-7"1'-5"3'-4"7'-1"2'-2"11/4" 1'-11"10'-103/4"2'-6"1'-2"2'-6"-0'-4" -0'-3"-0'-3" -0'-0" 0'-8" -0'-0" -0'-0" -0'-3" 0'-8" 0'-8" 1 S0 3SK-0I 1 A5.2 8" FOUNDATION WALL UNDER SHEAR WALL, ANCHOR BOLTS @ 48" O.C. HELD UP 6 " TO ALLOW 4" SLAB TO BE OVERLAID 36"X36"X12" CONCRETE PAD HAUNCHED SLAB AROUND ELEVATOR PIT & UNDER (3) POSTS ELEVATOR PIT, 8" DEPTH DROP FOR SLAB THROUGH DOOR OPENINGS HAUNCH FOR POST SUPPORT DROP FOR SLAB THROUGH DOOR OPENINGS DROP FOR SLAB THROUGH DOOR OPENING FOOTING BELOW, TYP. 4" CONCRETE SLAB, MATCH LEVEL OF EXISTING WAREHOUSE SLAB 4" CONCRETE SLAB, MATCH LEVEL OF EXISTING WAREHOUSE SLAB TOW NON- SLOPING SLAB THIS SIDE OF DASHED LINE TOWTOW TOW TOW TOS TOS TOS TOW SLOPE 1/8:12TOW 1 A4.1 1 A4.1 2 A4.1 2 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 2 A3.2 2 A3.2 EXTERIOR OF WALL BELOW EXTERIOR OF WALL BELOW ENTRY ROOF BELOW EXTERIOR WALL BELOW (2) 2X4 + 1/2" PLYWOOD WITH SIMPSON STRONG-TIE ACE4 & SOLID BLOCKING IN WALL NEW ROOF AT SAME PLANE AS EXISTING, MATCH SLOPE OF EXISTING ROOFEXISTING ROOF EXISTING ROOF 11 7/8" ENGINEERED JOISTS, @ 24" O.C. 11 7/8" ENGINEERED JOISTS, @ 24" O.C. 2X10 SPF @ 16" O.C. (2) 2X10 DROPPED BEAM HEADER HEADER (2) 1.75"X11.875" LVL BEAM SCALE: 1/4" = 1'-0"2 LOWER LEVEL FRAMING PLAN SCALE: 1/4" = 1'-0"3 UPPER LEVEL FRAMING PLAN SCALE: 1/4" = 1'-0"1 FOUNDATION PLAN SCALE: 1/4" = 1'-0"4 ROOF FRAMING PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 LOWER & UPPER LEVEL FLOOR PLANS A1.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o nASILL 8'-9"2'-6" 2'-6" A SILL 8'-9"2'-6"2'-6"A SILL 8'-9"2'-6"2'-6"01 8'-0"8'-0"02 8'-0"8'-0"04 6'-8"3'-0"126'-8" 3'-0" 13 2'-6"6'-0"13 6'-0"2'-6"UP35'-83/4"22'-51/2"28'-71/2"4'-6"31/2"3'-9"31/2"4'-51/2"31/2"4'-8"31/2"2'-107/8"31/2"3'-23/4"31/2"4'-7"31/2" 4'-8"31/2"8'-9"11'-51/2"10'-9"6'-5" 3'-8" 1'-8"2'-4"91/2" 3'-31/4"2'-1"3 A4.1 3 A4.1 4 A4.1 4 A4.1 SOUTH NORTH EAST 1 1/2" OVERHANG OF EXISTING WALL ABOVE SHEAR WALL: SHEATH WITH 1/2" OSB ONE SIDE, EXTEND TO ROOF PLANE LOW WALL: SLOPING CAP 30" ABOVE STAIR NOSE, TYP.BEAM ABOVE, SEE STRUCTURAL INTERIOR LOAD BEARING STUD FRAME WALL INDEPENDENT OF EXTERIOR WALL, TYP. NEW SLAB BOLLARD, SEE DETAIL X/A5.2BOLLARD, SEE DETAIL X/A5.2 PREFERRED ELEVATOR MACHINE ROOM LOCATION ALTERNATE ELEVATOR MACHINE ROOM LOCATION EXISTING CONSTRUCTIONTO REMAINSHELVES DOUBLE CAR GARAGE 02 ELEV. 03 ENTRY 01 2 A3.2 2 A3.2 03 6'-8"3'-0"3'-0"2'-0"1 A4.1 1 A4.1 2 A4.1 2 A4.1 1 A5.2DSILL 3'-0"3'-0" 6'-0" B Sill 3'-3 3/4"3'-6"2'-6"B Sill 3'-3 3/4"3'-6"2'-6"C SILL 3'-0"6'-0"6'-0"C SILL 3'-0"6'-0"6'-0"082'-8" 6'-8" 10 6'-8"2'-6"07 6'-8"3'-0"062'-6" 6'-8"092'-8" 6'-8"116'-8" 3'-0"DN3 A4.1 3 A4.1 4 A4.1 4 A4.1 SOUTH NORTH EAST12'-9" +/- CLEAR35'-71/2"13'-7"4'-10"8'-9"2'-0"2'-0"EQ.EQ.EQ.5'-3"23'-41/2"8'-101/2"12'-8"5'-6" 3'-8" 2 A3.2 2 A3.2 4 3 2 1 A7.1 8 7 6 5 A7.1 10 11 12 9 A7.1 ROOF ABOVE ROOF BELOW 36" WALL WITH CAP REMOVE EXISTING DOOR, PROVIDE CASED OPENING BENCH WITH BOOT CUBBIES BELOW EXTERIOR OF GARAGE WALL FRAMING BELOW (5) FIXED COMBINATION 36"X80" SCREEN/STORM DOOR PANELS WITH 'CABLE-RAIL' S.S. WIRE GUARD RAILING ON SOUTH SIDE, SEE X/A5.2 FIXED T.P. GLASS PANEL, SEE X/A5.2 OPERABLE SCREEN DOOR HVAC MODULE, SEE SHEET MV-1 GAS FIREPLACE APPLIANCE - LOCATION TO BE CONFIRMED RECYC. BINS EXISTING CONSTRUCTION TO REMAINCLOSET HALL 11 ELEV. 03 AWAY ROOM 13 DECK 15 ROOM TOILET 12 PORCH SCREENED 14 1 A4.1 1 A4.1 2 A4.1 2 A4.1053'-0" 6'-8" 23'-1" +/- CLEAR 31/2"4'-7"31/2"1'-6"31/2"8'-6"31/2"2'-6"31/2"SCALE: 1/4" = 1'-0"1 LOWER LEVEL PLAN SCALE: 1/4" = 1'-0"2 UPPER LEVEL PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 ROOF PLAN A1.2 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n E 2'-8"10'-8"6 A5.1 EXTERIOR OF WALL BELOW EXTERIOR OF WALL BELOW ENTRY ROOF BELOW NEW INSULATED WALL OVERLAYS EXISTING ROOF AND IS AIR SEALED TO ROOF SHEATHING NEW ROOF AT SAME PLANE AS EXISTING, MATCH SHINGLES AND SLOPE OF EXISTING ROOFEXISTING ROOF EXISTING ROOF NEW ROOF, MATCH SHINGLES AND SLOPE OF EXISTING ROOFSLOPESLOPESLOPE SLOPESLOPE EXISTING ROOF SLOPE4:12SCALE: 1/4" = 1'-0"1 ROOF PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 REFLECTED CEILING PLANS A2.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n DOUBLE CAR GARAGE 02 ELEV. 03 ENTRY 01 NOTE: LOCATIONS OF SPRINKLER HEADS YET TO BE DETERMINED HALL 11 ELEV. 03 AWAY ROOM 13 DECK 15 ROOM TOILET 12 PORCH SCREENED 14 2013%07%16(( ( A2 RCP Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( GENERAL NOTES 1. Dimensions on this Drawing are from face of finish surfaces and center lines of installed devices. 2. See Fire Sprinkler drawings for routing of piping and location of sprinkler heads. Report conflicts to Architect ( 3. See Mechanical Plans, Ventilation Plans and Power Plans for additional ceiling construction information. Report conflicts to Architect. 4. See Lighting Plans for lighting layout. Report conflicts to Architect. ( SCALE: 1/4" = 1'-0"1 LOWER LEVEL REFLECTED CEILING PLAN SCALE: 1/4" = 1'-0"2 UPPER LEVEL REFLECTED CEILING PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 ELEVATIONS A3.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 0'-0" 14'-7" EXISTING GRADE 17" DROP AT 10'-0" AWAY FROM EAST SIDE OF BUILDING BOLLARDSBOLLARDS 01 02 B C A A B E 03 12 12 12 EXISTING METAL PANELS (BLUE) EXISTING METAL PANELS (RED) EXISTING PAINTED CMU PROPOSED NEW ADDTIONEXISTING EXISTING ASPHALT SHINGLES FIRST FLOOR SECOND FLOOR 3 A3.1 6'-0" CLEAR PRESERVATIVE FINISHED T&G VERTICAL CEDAR BOARDS (1X4) (DECK ENCLOSING WALLS ONLY) FACTORY FINISHED PAINTED STEEL PANELS - VERTICAL ORIENTED TO MATCH EXISITNG PAINTED METAL INSULATED GARAGE DOORS PAINTED WOOD FIBER CEMENT FASCIA TO MATCH EXISTING, TYP. ASPHALT F.G. SHINGLES TO MATCH EXISITNG FACTORY FINISHED PAINTED STEEL PANELS - VERTICAL ORIENTED TO MATCH EXISITNG PAINTED FIBER CEMENT PANEL - ACCENT COLOR (OR VERTICAL CEDAR BOARDS) PAINTED FIBER CEMENT PANEL - ACCENT COLOR (OR VERTICAL CEDAR BOARDS) LIGHT FIXTURE @ 11' AFL LIGHT FIXTURE @ 11' AFL ERV EXHAUST VENT ERV EXHAUST VENT FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 A D 12 12 11 EXISTING PAINTED CMU EXISTING METAL PANELS (RED) PROPOSED NEW ADDTIONEXISTING FACTORY FINISHED PAINTED STEEL PANELS - VERTICAL ORIENTED TO MATCH EXISITNG FLUE FOR GAS FIRED APPLIANCE, MAINTAIN REQUIRED CLEARANCE TO WINDOW AIR SOURCE HEAT PUMP COMPRESSOR/CONDENSER UNIT - WALL MOUNTED, PRECISE LOCATION TBD 'MODINE' VENT, MAINTAIN REQUIRED CLEARANCE TO WINDOW 51/2"21/2"11/4" 21/2"11/4" 21/2"31/2"3"3'-0"1'-4"5"1'-4" 2X6 CAP - BEVELED TOP 2X3 TOP RAIL 2X3 BOTTOM RAIL 5/4 VERTICAL BALUSTRADE ELEMENTS, PATTERN: 5 1/2" - 1 1/4" - 1 1/4"... 5/4 VERTICAL BALUSTRADE ELEMENTS, PATTERN: 5 1/2" - 1 1/4" - 1 1/4"... DECORATIVE PROFILE CUT BY ARCHITECT INTO BOARDS PROVIDED BY CONTRACTOR 4X4 POST SPACE DECKING 1X WOOD FASCIA 2X10 DECK JOIST BEYOND, SEE STRUCTURAL PLANS FOR MORE INFO DOUBLE 2X10 DECK JOIST BEYOND ON EACH SIDE OF POST, SEE STRUCTURAL PLANS FOR MORE INFO DOUBLE 2X10 DECK JOIST BEYOND ON EACH SIDE OF POST, SEE STRUCTURAL PLANS FOR MORE INFO ALL CEDAR ELEMENTS: PORT ORFORD CEDAR, CLEAR PRESERVATIVE OIL FINISH 2013%07%16((( A3 Elevs Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( GENERAL NOTES 1. Verify existing floor elevations in the field and notify architect of discrepancies. 2. Remove existing metal siding panels for re-use — especially if there is difficulty in purchasing matching colors or profiles. ( SCALE: 1/4" = 1'-0"1 SOUTH ELEVATION SCALE: 1/4" = 1'-0"2 EAST ELEVATION SCALE: 1 1/2"= 1'-0"3 DECK BALUSTRADE - DETAILED ELEVATION Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 ELEVATION & BUILDING SECTION A3.2 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n ASPHALT F.G. SHINGLES TO MATCH EXISITNG PROPOSED NEW ADDTION EXISTING EXISTING ASPHALT SHINGLES EXISTING METAL PANELS (RED) EXISTING PAINTED CMUFACTORY FINISHED PAINTED STEEL PANELS - VERTICAL ORIENTED TO MATCH EXISITNG 0'-0" 14'-6" SHEAR WALL SHEAR WALL CC FIRST FLOOR DECK 3 A9.1 CLEAR PRESERVATIVE FINISHED VERTICAL CEDAR BOARDS (1X4) (DECK ENCLOSING WALLS ONLY) LIGHT FIXTURE @ 11' AFL LIGHT FIXTURE @ 11' AFL CLEAR PRESERVATIVE FINISHED VERTICAL CEDAR BOARDS (1X4) (DECK ENCLOSING WALLS ONLY) 2013%07%16(( ( A3 Elevs Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( GENERAL NOTES 1. Verify existing floor elevations in the field and notify architect of discrepancies. 2. Remove existing metal siding panels for re-use — especially if there is difficulty in purchasing matching colors or profiles. ( SCALE: 1/4" = 1'-0"1 NORTH ELEVATION SCALE: 1/4" = 1'-0"2 LONGITUDINAL SECTION Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 BUILDING SECTIONS A4.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 5 A5.1 9'-0"8'-0"0'-0" 14'-7" 7'-11" +/- WOOD CAP WOOD CAP CONCRETE SLAB 1/2" BELOW INTERIOR F.F.E. 2X4 FRAMED ROOF WITH 2X4 FRAMED CEILING & 2X6 BEAM 2X6 FRAMED CEILING 2X4 FRAMED CEILING WOOD BASE FIRST FLOOR SECOND FLOOR OPEN TO HALL & KITCHEN TOP PLATE 7'-0" +/-5'-0"6'-8" MIN.2'-8"VALANCE LIGHT FIXTURE 1/2" OSB TO PROTECT INSULATION NETTING 9'-0" +/-9'-0"7'-6"0'-0" 14'-7" 7'-11" +/- ELEVATOR PIT (DEPTH TO SUIT PRODUCT) 2X4 INTERIOR STUD LOAD BEARING WALL, TYP. WOOD CAP WOOD CAP 1X12 PAINTED SHELVING, 6 TIERS, TBD BY OWNER 2X4 FRAMED CEILING 1/2" OSB TO PROTECT INSULATION NETTING 2X4 FRAMED CEILING WOOD BASE ELEVATOR SHAFT OPEN TO KITCHEN OPEN UNDER STAIR LANDING FIRST FLOOR SECOND FLOOR TOP PLATE 4 A5.1 1 S0 VALANCE LIGHT FIXTURE #DrgID #LayID 0'-0" 14'-7" 7'-11" +/- FIXED T.P. GLASS PANEL, SEE X/A5.2 FIRST FLOOR SECOND FLOOR OPEN UNDER STAIR LANDING TOP PLATE 10'-0"CLEAR PRESERVATIVE FINISHED VERTICAL T&G CEDAR BOARDS (1X4) (DECK ENCLOSING WALLS ONLY) MEMBRANE ROOFING SYSTEM 1/2" OSB TO PROTECT INSULATION NETTING 2X6 CEILING FRAMING 2 A5.1 0'-0" 14'-7" 7'-11" +/- FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 FIXED 6 MIL. PLATE GLASS, SEE DETAIL X/A5.2 FIRST FLOOR SECOND FLOOR OPEN UNDER STAIR LANDING TOP PLATE 1 A5.1 3 A5.1 1/2" OSB TO PROTECT INSULATION NETTING 2X6 CEILING FRAMING SCALE: 1/4" = 1'-0"1 SECTION 1 SCALE: 1/4" = 1'-0"2 SECTION 2 SCALE: 1/4" = 1'-0"3 SECTION 3 SCALE: 1/4" = 1'-0"4 SECTION 4 Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 WALL SECTIONS A5.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n TO MATCH EXISTING 6" MIN.0'-0" +0'-8" MATCH EXISTING MATCH EXISTING ASPHALT SHINGLE ROOFING TO MATCH EXISTING 3/4" PLYWOOD 5/8" GWB LSL RIM JOIST TYPE 3B CONSTRUCTED EXTERIOR WALL: 3 5/8" STEEL L.B. FRAMING WITH (2) LAYERS 5/8" TYPE 'X' GWB EACH SIDE, CELLULOSE FILLED CAVITY 2" POLYISO (PAPER FACED, R6+/INCH) WRAP DRAINAGE PLANE - TYVEK OR EQUIV. 1X4 SPF WOOD FURRING FASTENED THROUGH TO METAL FRAMING METAL PANEL SIDING TO MATCH EXISTING, FASTENED TO FURRING 12" CONCRETE WALL GRADE 4" CONCRETE SLAB 2" EPS TYPE 1X2" EPS TYPE 1X 3/4" FRT PLYWOOD, PAINT COMPACTED FILL 3 5/8" STEEL FRAMED LOAD BEARING WALL 5/8" GWB TYPE 'X' LSL BAND JOIST 9 1/2" ENGINEERED I-JOISTS, WITH DENSE PACK CELLULOSE, PROVIDE WEB STIFFENERS AT ALL BEARING LOCATIONS ACOUSTIC SEALANT 3/4" OSB SUBFLOOR FINISHED FLOOR, TBD WOOD BASE CONTINUOUS BEAD OF CONSTRUCTION ADHESIVE GWB STEEL TRACK WITH FRT 2X4 INFILL PEICES TIMBERLOCK LAG SCREWS @ 8" O.C. TIEING FLOOR STRUCTURE TO WALL AIR BARRIER, SEAL TO POLYISO TOS TOW (EXCEPT AS NOTED ON STRUCTURAL DRAWINGS) 1'-0" PRE-FAB APPLIED EAVE SOFFIT STRUCTURE (2) LAYERS 1 1/2" POLYISO 3/4" PLYWOOD 11 7/8" ENGINEERED I-JOIST RAFTERS @ 16" O.C. WITH DENSE (3+ PCF) CELLULOSE 1"9"CLEAR PRESERVATIVE FINISHED VERTICAL CEDAR BOARDS (1X4) ON 1X4 SPF WOOD FURRING WRAP DRAINAGE PLANE - TYVEK OR EQUIV., LAP OVER MEMBRANE ROOFING EPDM MEMBRANE ROOFING 2X10 PT DECK JOISTS (2) 2X10 PT RIM DECK BOARDS 3/4" PLYWOOD ON 2" POLYISO ON 3/4" PLYWOOD 2X8 SPF ROOF RAFTERS HUNG FROM BEAM 5/8" GWB LVL BEAM, SEE STRUCTURAL DRAWINGS BLOCKING BETWEEN JOISTS1/4" MESH DRAIN SCREEN 2'-0" 01/2"2"3 A3.1 EPDM MEMBRANE ROOFING (3) GALV. STEEL POSTS, SEE STRUCTURAL (3) 2X10 PT BEAM 2X10 PT DECK JOISTS, BOTH SIDES OF EACH POST, THROUGH BOLTED DECK BOARDS ROOF EDGE (PER MANUFACTURER) 2X8 NAILER 2X8 RIM 2X8 BLOCKING 2X4 TOP PLATE SEE TYP. DETAILED WALL SECTION FOR WALL CONSTRUCTION SIMPSON HOLD-DOWN - BOLTED TO POST & SHEAR NAILED LEG ALONG JOIST 2X4 PT BLOCKING (EXCEPT WHERE LIGHT FIXTURE INSTALLED) 4X4 POST BEVEL BOTTOM 1X WOOD FASCIA 2X10 PT BLOCKING LIGHT FIXTURE BEYOND, SEE DETAIL 4/E2.1 4"1/2" PLYWOOD 3 E2.16"DRIP EDGE FASCIA FIBER CEMENT SOFFIT ASPHALT SHINGLE ROOFING 3/4" PLYWOOD SHEATHING METAL SIDING 2" POLYISO (2) LAYERS 5/8" TYPE 'X' GWB LVL HEADER, SEE STRUCTURAL DRAWINGS 2X4 SOFFIT FRAMING GWBWINDOW FLASHING TO MATCH SIDING PANEL COLOR 2X4 EAVE OUT RIGGER ANCHORED IN PLANE OF 3" POLYISO 2X4 BLOCKING (2) LAYERS OF 1 1/2" POLYISO 3/4" PLYWOOD 11 7/8" ENGINEERED I-JOIST RAFTERS @ 16" O.C. WITH DENSE (3+ PCF) CELLULOSE 5 E2.1 RIGID INSULATION INFILL SEE DETAILED WALL SECTION FOR WALL CONSTRUCTION DRILL & BLOW CELLULOSE IN ROOF ASSEMBLY, SEE DETAILED WALL SECTION PORCH ROOF FRAMING BLOCKING BLOWN IN CELLULOSE INSULATION LED ROPE LIGHT 1/2"x6 V-GROOVE PINE CEILING, PAINTED WOOD SIDING SEE DETAILED WALL SECTION FOR EXTERIOR WALL CONSTRUCTION ASPHALT SHINGLE ROOFING (2) 2X6 BEAM 1/2" MDO, PAINTED WRAP WITH 1X WOOD, PAINTED FLASHING SOFFIT TO MATCH EXISTING 3/4" PLYWOOD 2X4 WOOD FRAMING2X4 WOOD FRAMING SCALE: 1 1/2"= 1'-0"1 DETAILED WALL SECTION SCALE: 1 1/2"= 1'-0"2 SECTION @ GARAGE ROOF/WALL SCALE: 1 1/2"= 1'-0"3 SECTION @ GARAGE ROOF/DECK EDGE SCALE: 1 1/2"= 1'-0"4 SECTION @ CLEARSTORY SCALE: 1 1/2"= 1'-0"6 SECTION @ PORCH ROOF SCALE: 1 1/2"= 1'-0"5 ENTRY ROOF DETAIL Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 WALL SECTIONS & EXTERIOR DETAILS A5.2 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 0'-0"-0'-1/2" +0'-8" 4" CONCRETE SLAB 4" CONCRETE SLAB 2" EPS TYPE 1X2" EPS TYPE 1X 3/4" PT PLYWOOD, PAINT 3 5/8" STEEL FRAMED LOAD BEARING WALL (2) LAYERS OF 5/8" GWB FIRST FLOOR TOS TOW 10" BOLLARD 2"3 A5.2 SEE DETAILED WALL SECTION FOR EXTERIOR WALL CONSTRUCTION ASPHALT SHINGLE ROOFING FLASHING 1X6 PINE V-GROOVE LINING BOARDS, PAINTED TOP OF STUD BLOCKING 1X VERTICAL T&G CEDAR SIDING BOARD TWO-PLY 2X10 SPF LEDGER LAG-SCREWED TO WOOD BLOCKING AT EACH STUD LOCATION BLOCKING: TWO- PLY LVL LEDGER WITH JACK STUD EACH END3/4" PLYWOOD 2X10 SPF WOOD FRAMING W WOOD JACK STUD EXTENDS DOWN TO BASE PLATE OF OPENING, HEADER & IS FASTENED TO STEEL STUD & SUPPORTS 2X10 BLOCKING STEEL STUD 2X10 LEDGER LAG-SCREWED TO WOOD BLOCKING WITH 3/4" BOLT @ 8" O.C. STAGGER 3" FROM TOP & BOTTOM 2X10 BLOCKING SCALE: 1 1/2"= 1'-0"1 FOUNDATION @ ENTRY DOOR SCALE: 1" = 1'-0"4 BOLLARD DETAIL SCALE: 1 1/2"= 1'-0"2 SECTION @ PORCH ROOF 2 SCALE: 3" = 1'-0"3 PLAN DETAIL @ BLOCKING Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 INTERIOR ELEVS, DETAILS & FINISH SCHEDULE A7.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 7'-0"STAIR DOWN RECYCLING CLOSET 13 A7.1 VALANCE LIGHT FIXTURE OPEN TO KITCHEN BENCH WITH BOOT CUBBIES BELOW VALENCE LIGHT FIXTURES, SEE DETAIL 3/E2.1 1'-6"WOOD CAP FINISH SCHEDULE ROOM # 01 02 03 11 12 13 14 15 ROOM NAME ENTRY DOUBLE CAR GARAGE ELEV. HALL TOILET ROOM AWAY ROOM SCREENED PORCH DECK FLOOR MATERIAL CONCRETE CONCRETE -- MARMOLEUM MARMOLEUM WOOD (STRIP H.W.) PLASTIC LUMBER PLASTIC LUMBER FINISH POLISH SEALER -- FACTORY FACTORY CLEAR FACTORY FACTORY BASE MATERIAL WOOD N/A -- WOOD WOOD WOOD N/A N/A FINISH PAINT N/A -- PAINT PAINT PAINT N/A N/A WALL MATERIAL GWB GWB -- GWB GWB GWB -- -- FINISH PAINT PAINT -- PAINT PAINT PAINT -- -- CASING MATERIAL WOOD WOOD -- WOOD WOOD WOOD -- -- FINISH PAINT PAINT -- PAINT PAINT PAINT -- -- CEILING MATERIAL GWB GWB -- GWB GWB GWB WOOD (T&G BOARD) N/A FINISH PAINT PAINT -- PAINT PAINT PAINT PAINT N/A NOTES EXCEPT CEILING UNDER DECK - WHICH IS TO BE LEFT OPEN SEE ELEVATOR SPECIFICATIONS DECKING: "TREX ACCENTS", SEE EXTERIOR ELEVATIONS FOR MORE INFORMATION SEE EXTERIOR ELEVATIONS FOR MORE INFORMATION 2013%06%11''' A7 Int Elev Dwg Notes.docx' ' {Note: When PDF’ing - use custom paper size 5”x36”}' ' ' ' GENERAL NOTES 1. Dimensions are to face of finish unless otherwise noted. ' GAS FIRE APPLIANCE, TBD GAS FIRE APPLIANCE, TBD 8'-0"AIR VENT SUPPLY 7'-6"AIR SOURCE HEAT PUMP WALL MOUNTED, CENTERED 12" MIN.7'-0"EXHAUST FAN GFI POWER, LIGHT SWITCH, FAN CONTROL & HEAT PANEL CONTROL LOCATION TOILET TISSUE LIGHT MIRROR SCALE: 3/8" = 1'-0"11 HALL EAST SCALE: 3/8" = 1'-0"10 HALL NORTH SCALE: 3/8" = 1'-0"9 HALL WEST SCALE: 3/8" = 1'-0"12 HALL SOUTH SCALE: 3" = 1'-0"13 WOOD CAP DETAIL SCALE: 3/8" = 1'-0"4 AWAY ROOM NORTH SCALE: 3/8" = 1'-0"3 AWAY ROOM EAST SCALE: 3/8" = 1'-0"2 AWAY ROOM SOUTH SCALE: 3/8" = 1'-0"1 AWAY ROOM WEST SCALE: 3/8" = 1'-0"5 BATH WEST SCALE: 3/8" = 1'-0"8 BATH NORTH SCALE: 3/8" = 1'-0"6 BATH SOUTH SCALE: 3/8" = 1'-0"7 BATH WEST Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 WINDOW & DOOR SCHEDULES & DETAILS A9.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n WINDOW SCHEDULE MARK A B C D E QUANTITY 3 2 2 1 1 9 MANUFACTURER PELLA (DESIGNER SERIES) PELLA (DESIGNER SERIES) PELLA (DESIGNER SERIES) PELLA (DESIGNER SERIES) PELLA (DESIGNER SERIES) MODEL FG CA DH DH FG SIZE ( WIDTH X HEIGHT) 2'-6"x2'-6" 2'-6"x3'-6" 6'-0"x6'-0" 3'-0"x6'-0" 10'-8"x2'-8" AREA 6.41 8.95 36.38 18.31 28.06 156.26 sq ft TYPE REMARKS TO MATCH EXISTING TO MATCH EXISTING TO MATCH EXISTING TO MATCH EXISTING (4) UNITS MULLED, TO MATCH EXISTING 3D Front View ID A B C D E Wind-125 2013%07%11''' A9.1 Door Dwg Notes.docx' ' {Note: When PDF’ing - use custom paper size 5”x36”}' ' ' ' GENERAL NOTES 1. Door and window width & height dimensions given to window unit (not R.O.) 2. Window sill P.H. (Plate Height) indicated on plans is top of rough opening framing at sill. 3. Fill voids between frames and rough openings with low expansion spray foam insulation or expanding foam gaskets. 4. Provide structural fill as required to provide solid anchoring for door jamb. 5. See Wall Types and/or Detailed Wall Sections for wall construction and widths. 6. Provide shims as necessary, and ensure that shims do NOT obstruct a continuous air sealing around the door/window frame. 7. Refer to Window Installation Sequence for complete window installation information. ' ' ' ' ' DOOR SPECIFICATION NOTES TYPE B: Pella Door – Designer Series 750 (to match existing) Doors and frames to be delivered as set-up units including: • Threshold • Three hinge mounting • No jamb extensions • R-value — • Weather seals • Glazing – Triple glazed using “advanced low-e insulating glass” • Screen type & color – match existing • Integral shades — (Owner to advise) • Exterior Finish – match existing • Interior Finish - Interior wood to be primed, ready to receive paint • Door Hardware – Pella standard; color matched to existing ' ' WINDOW SPECIFICATION NOTES Use Pella Windows – Designer Series (to match those in existing apartment) Window Characteristics: • Window Construction – Aluminum clad wood frame and sash with aluminum Brickmould w/ nailing flange - color match to exterior window frame. • Exterior Color – match existing • Interior Color – match existing • Insect Screens – to be provided on operable sashes • No divided lites • No jamb extensions • Glazing - Double 3mm with third removable “Energy” panel • Glazing Cavity – Argon filled • U value - 0.25 NFRC • SHGC - highest available • Integral operable shades • Hardware – Pella standard • Hardware Color – matching interior frame color ' ' 2013%07%11'''A9.1 Door Dwg Notes.docx''{Note: When PDF’ing - use custom paper size 5”x36”}''''GENERAL NOTES 1. Door and window width & height dimensions given to window unit (not R.O.) 2. Window sill P.H. (Plate Height) indicated on plans is top of rough opening framing at sill. 3. Fill voids between frames and rough openings with low expansion spray foam insulation or expanding foam gaskets. 4. Provide structural fill as required to provide solid anchoring for door jamb. 5. See Wall Types and/or Detailed Wall Sections for wall construction and widths. 6. Provide shims as necessary, and ensure that shims do NOT obstruct a continuous air sealing around the door/window frame. 7. Refer to Window Installation Sequence for complete window installation information. '''''DOOR SPECIFICATION NOTES TYPE B: Pella Door – Designer Series 750 (to match existing) Doors and frames to be delivered as set-up units including: • Threshold • Three hinge mounting • No jamb extensions • R-value — • Weather seals • Glazing – Triple glazed using “advanced low-e insulating glass” • Screen type & color – match existing • Integral shades — (Owner to advise) • Exterior Finish – match existing • Interior Finish - Interior wood to be primed, ready to receive paint • Door Hardware – Pella standard; color matched to existing ' ' WINDOW SPECIFICATION NOTES Use Pella Windows – Designer Series (to match those in existing apartment) Window Characteristics: • Window Construction – Aluminum clad wood frame and sash with aluminum Brickmould w/ nailing flange - color match to exterior window frame. • Exterior Color – match existing • Interior Color – match existing • Insect Screens – to be provided on operable sashes • No divided lites • No jamb extensions • Glazing - Double 3mm with third removable “Energy” panel • Glazing Cavity – Argon filled • U value - 0.25 NFRC • SHGC - highest available • Integral operable shades • Hardware – Pella standard • Hardware Color – matching interior frame color ' ' WINDOW WATER BARRIER MEMBRANE, TAPE TO WINDOW NAILING FIN 'J' CHANNEL P-JC10 (McILROY) 1/4 FURRING AIR BARRIER CONTINUITY: TAPE POLYISO TO WINDOW JAMB BOX AIR BARRIER CONTINUITY: SPRAY SEALANT WINDOW JAMB BOX TO WINDOW FRAME GWB RETURN WINDOW HEADER, SEE STRUCTURAL DRAWINGS 3/4" PLYWOOD WINDOW JAMB BOX CAULK METAL SIDING PANEL POLYISO WINDOW AIR BARRIER CONTINUITY: SPRAY SEALANT OR GASKET AIR SEAL WINDOW FRAME TO WINDOW JAMB BOX SELF ADHESIVE FLASHING TAPE SILL PAN OVER CLAPBOARD - TO ACHIEVE SLOPE 'J' CHANNEL P-JC10 (McILROY) 1/4 FURRING WATER BARRIER MEMBRANE METAL SIDING PANEL 3/4" PLYWOOD WINDOW JAMB BOX HARDWOOD SILL (TO MATCH EXISTING) AIR BARRIER CONTINUITY: TAPE POLYISO TO WINDOW JAMB BOX APRON (TO MATCH EXISTING) DOOR SCHEDULE NO. 01 02 03 04 05 06 07 08 09 10 11 12 LOCATION GARAGE GARAGE ENTRY ELEVATOR STAIR CLOSET ELEVATOR AWAY ROOM DECK TOILET ROOM PORCH SCREEN DOOR WIDTH 8'-0" 8'-0" 3'-0" 3'-0" 3'-0" 2'-6" 3'-0" 2'-8" 2'-8" 2'-6" 3'-0" 3'-0" HEIGHT 8'-0" 8'-0" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" 6'-8" TYPE C C E A B D A A B A F DOOR CONST. INSULATED INSULATED IM SC SC SC SC SC CW SC WF (PINE) SC THK. 0'-11/4" 0'-11/4" 0'-13/4" 0'-13/4" 0'-13/8" 0'-13/8" 0'-13/4" 0'-13/8" 0'-13/4" 0'-13/8" 0'-13/8" 0'-13/8" FINISH PAINT CLEAR CLEAR CLEAR CLEAR CLEAR FACTORY CLEAR CLEAR GLASS ITP ITP - ITP TP FRAME MAT. METAL WOOD WOOD WOOD CLAD WOOD WOOD PORCH POSTS WOOD FIRE RATING NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE NONE HDWR. SET AREA 59.55 59.55 18.87 21.38 21.03 17.66 21.38 18.79 19.13 17.66 20.13 21.03 REMARKS INTERLOCK HARDWARE POCKET DOOR INTERLOCK HARDWARE 3/4" UNDERCUT PELLA (TO MATCH EXISTING) 3/4" UNDERCUT HINGED OPERABLE 3/4" UNDERCUT 10"10"REMOVABLE/ INTERCHANGEABLE STORM PANEL & SCREEN PANEL A B C FG FG FG FG D E FG F1"2X10 PT DECK FRAMING DECK BOARDS DOOR (OUTSWING) FINISHED FLOOR EPDM MEMBRANE ROOFING AIR BARRIER CONTINUITY: SPRAY SEALANT DOOR JAMB BOX TO DOOR FRAME 3/4" PLYWOOD DOOR JAMB BOX CAULK GWB RETURN 1/4 FURRING AIR BARRIER CONTINUITY: TAPE POLYISO TO DOOR JAMB BOX DOOR HEADER, SEE STRUCTURAL DRAWINGS CEDAR SIDING RETURNS CEDAR SIDING WATER BARRIER MEMBRANE EXTENSION THRESHOLD Optional Fold-outInstallation Fin SCALE: 3" = 1'-0"2 WINDOW HEAD (TO MATCH EXISTING IN APPEARANCE) SCALE: 3" = 1'-0"1 WINDOW SILL (TO MATCH EXISTING IN APPEARANCE) SCALE: 3" = 1'-0"3 DOOR HEAD & THRESHOLD WINDOW TYPES FG FG FG FG FG DOOR TYPESABBREVIATIONS IM INSULATED METAL SC SOLID CORE CW CLAD WOOD FG FIXED GLAZING WF WOOD FRAME ITP INSULATED TEMPERED TP TEMPERED Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 MECHANICAL & VENTILATION PLANS MV1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n AIR SOURCE HEAT PUMP COMPRESSOR/CONDENSER UNIT - WALL MOUNTED (PRECISE LOCATION TBD) ALT. #1: ASHP WALL MOUNTED CASSETTE GAS FIRED 'MODINE' HEATER, CEILING MOUNTED (PRECISE LOCATION TBD) DOUBLE CAR GARAGE 02 ELEV. 03 ENTRY 01 ASHP INTERIOR CASSETTE WALL MOUNTED, BOTTOM @ 7'-6" GAS FIRED APPLIANCE, FLU THROUGH EAST WALL PANASONIC THROUGH WALL EXHAUST FAN FAN CONTROL HEAT RECOVERY UNIT, FANTECH SH704, IN SPACE ABOVE SHELVING INSULATE & AIR SEAL DUCTS, TYP. ELECTRIC RADIANT HEATING PANEL, CEILING MOUNTED SUPPLYEXHAUST INTAKEEXHAUST HALL 11 ELEV. 03 AWAY ROOM 13 DECK 15 TOILET PORCH SCREENED 14 2013%07%16((( M1 Mech Plans Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( MECHANICAL GENERAL NOTES 1. The system shall comprise (Manufacturer and model TBD) X-ton ductless split-system air sourced heat pump. 2. Compressor outdoor unit to be mounted on the east wall. 3. Indoor ductless wall-mounted or ducted concealed cassettes as follows: W1: Wall-mounted cassette, Away Room west wall at 7’ 6” AFL; size TBD (NOTE: The Hall space will be sufficiently conditioned from the adjacent conditioned spaces on either side. ALTERNATE (in place of Modine Unit) W2: Wall-mounted cassette, Lower stair west wall at 10’ 0” AFL; size TBD 4. Install refrigerant piping without any joints in concealed locations. 5. Controls: Manufacturer’s standard 6. Condensate lines to be indirectly linked to the waste piping and the locations to be shown on the full system submittal. Provide clean-outs as required by code with required access panel locations to be reviewed by the Architect before installation. 7. Subcontractor is required to prepare a full system submittal, including products, duct layouts, and controls, and provide or confirm heating and cooling load calculations. System is to be installed in full accordance with the manufacturer’s recommendations & requirements by a subcontractor fully trained & certified by the system manufacturer. 8. No backup electric resistance heating capability is required. 9. Sound attenuation: To be provided if sound levels at any register exceed 42 DbA. 10. Operating ranges: Cooling will be 23°F DB to 115°F DB Heating will be -5°F WB to 60°F WB 11. Provide written warranty, signed by the manufacturer for a period of 5 years (parts) and 7 years (compressor) from the date of substantial completion. A diamond installer is required to qualify for the full warranty. 12. Provide a Operations and Maintenance manual in a three-ring binder along with a full demonstration of the system operation at the time of commissioning. Provide a commissioning report confirming the achieved of the air-flows at each register. 13. Seal penetrations through the exterior wall plane using spray sealant foam in an annulus space of at least ½” width. 14. Do not use this system at all during construction and ensure that all equipment is kept clean. 2013%07%16((( V1 Vent Plans Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( VENTILATION GENERAL NOTES 1. Provide a Panasonic Whisper Wall Fan 70 cfm capacity; 8” duct; installed on the west wall of the Toilet Room. Provide a 60-30-20-10 electronic timer control mounted in conjunction to the lighting switches and GFI outlet inside the door. 2. Provide a Fantech SH704 Model Heat Recovery Unit (HRV) to provide fresh air to the Away Room and exhaust from the stair well. 3. Mount the SH704 unit in the attic space over the Recycling Shelves. Provide service access from an access panel above those shelves 4. HRV unit to be mounted on vibration-isolating dampers (or equivalent) to avoid any structure borne vibration. 5. Fresh air intake and exhaust ducts from unit to the exterior to be insulated with 1 ½” fiberglass (equal to Certainteed Standard duct- wrap or circular ductwork and industrial insulation board for rectangular ductwork) and completely air sealed. All joints in ductwork to be tightly air-sealed with mastic or aluminum tape. 6. Supply and exhaust return ducts from the unit to conditioned spaces need not be insulated. 7. Backdraft dampers to be a Cape Backdraft Damper by Tamarack Technologies. 8. Seal duct penetrations through the exterior wall plane using spray sealant foam in an annulus space of at least ½” width. 9. Sound attenuation to be provided if sound levels at any register exceed 42DbA. 10. Duct layouts are schematic. The contractor is responsible for achieving an arrangement that meets airflow and noise requirements. 11. Subcontractor is required to prepare a full system submittal including products, duct layouts and controls. System is to be installed by a fully trained installer and in full accordance with the manufacturer’s recommendations and requirements. 12. Provide a the warranty signed by the manufacturer from the date of substantial completion. 13. Provide an operations and maintenance manual in a three-ring binder along with a full demonstration of the system operation at the time of commissioning. Provide a commissioning report confirming the airflows achieved at each register. SCALE: 1/4" = 1'-0"1 LOWER LEVEL MECH/VENT PLAN SCALE: 1/4" = 1'-0"2 UPPER LEVEL MECH/VENT PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 POWER PLAN E1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n UPPOWER TO GARAGE DOOR OPENERS POWER TO GARAGE DOOR OPENERS POWER TO ASHP COMPRESSOR/ CONDENSER UNIT POWER TO ELEVATOR MACHINE EQUIPMENT (PRECISE LOCATION TBD) ELECTRICAL SUB- PANEL - FROM MAIN SERVICE PANEL IN EXISTING BUILIDNG DOUBLE CAR GARAGE 02 ELEV. 03 ENTRY 01DN GFCI POWER FOR GAS FIRE APPLIANCE, TBD POWER TO WALL MOUNTED ASHP POWER SWITCH TO HRV OUTLET POWER TO HRV UNIT PANASONIC THROUGH WALL EXHAUST FAN, SEE SHEET MV.1 ELECTRIC RADIANT HEATING PANEL, CEILING MOUNTED CONTROLS FOR EXHAUST FAN AND HEATING PANEL HALL 11 ELEV. 03 AWAY ROOM 13 DECK 15 ROOM TOILET 12 PORCH SCREENED 14 2013%07%16(( ( E1 Power Plans Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( GENERAL NOTES 1. Data shown on these plans is intended to be supplemented by a comprehensive walk-through by the Owner, Electrician and General Contractor in which the data shown above is confirmed and additional outlets, as required by the Electrical Code, are determined and located. 2. Electrician is to complete an electrical load / demand computation for the house and connected outbuildings – and to propose / confirm the size of the main service panel. 3. Switched outlets are shown on this drawing. Switch locations are shown on the Lighting Plan E-1. 4. Smoke and CO detectors (if required) to be hard wired to central system. 5. Electric Radiant Heating Panel: install a Solid State Heating ‘Enerjoy’ 2’ x 2’ 22RP-4 panel. 120V; 1.7 Amp (providing up to 682 Btu/Hr) on the ceiling of the Toilet Room. Provide control switch with a 30 minute timer. 6. Emergency Generator: A 7.5Kw gas powered unit is to be provided and installed in a location as directed by the Architect on the roof of the existing commercial building to the west of the apartment. 7. Generator to be coupled to the following circuits/equipment: (Owner to provide circuits to be powered by the generator.) 8. Seal conduit and electrical cable penetrations through the AAC wall plane using spray sealant foam in an annulus space of at least ¼” width. DRILL ONE HOLE FOR EACH CABLE. SCALE: 1/4" = 1'-0"1 LOWER LEVEL POWER PLAN SCALE: 1/4" = 1'-0"2 UPPER LEVEL POWER PLAN Revisions Drawn by: Checked by:BC SW Scale: Project No. 22 August 2013Date: C Coldham & Hartman Architects2013 This drawing is not intended, nor shall be used for, construction, unless the signed seal of a design professional is affixed.A2Z Addition57 King StreetNorthampton, MA13-07 LIGHTING PLAN & LIGHTING SCHEDULE E2.1 File: 13-07 A2Z Addition.pln Print Date: 8/22/1322 Au g ust 2 0 1 3 For Co nstr u cti o n 3UP 8'-0"7'-10"5'-0"5'-0"2'-0"CONNECT TO D-1 FIXTURE & SWITCH AT LANDING SEE DETAIL 4/E2.1SEE DETAIL 4/E2.1 L-4 C-1 C-1 D-1 D-1 D-1 D-1 D-1 D-1 D-1 L-4 L-4 L-4 D-1 D-1 DOUBLE CAR GARAGE 02 ELEV. 03 ENTRY 01 2013%07%16(( ( E2 Lighting Plans Dwg Notes.docx( ( {Note: When PDF’ing - use custom paper size 5”x36”}( ( ( ( GENERAL NOTES 1. Electrical contractor is to prepare a lighting fixtures submittal based on the lighting fixture schedule and present for the Owner’s and Architect’s review prior to ordering any fixtures. 2. Switch locations for switched receptacles shown on this drawing; receptacle locations are shown on Lighting Plan E-1. 3. Switch plate (and receptacle cover) color(s) to be confirmed with Owner from standard range offered. 4. Refer to Reflected Ceiling Plan A2-1 and Interior Elevations A7-1 and Exterior Elevations A3-1 for additional information regarding locations of fixtures. 5. All fixtures to be UL listed. 6. Electrical contractor shall verify ceiling types prior to ordering fixtures. 7. Seal conduit and electrical cable penetrations through the exterior wall plane using spray sealant foam in an annulus space of at least ¼” width. DRILL ONE HOLE FOR EACH CABLE. Gates House Luminaire Schedule 7/16/13 Coldham Hartman, Architects 16500-1 Cut she et Fixture Type Location Description Lamps Control Manufacturer's Catalog Notes X D-1 Various Ceiling-mounted, recessed downlight — 6" diameter fixture (Note: this fixture is suitable for wet areas) 11W of LED @ 50+ Lumens per watt — ; color temp 2,700K Dimmable ECO-SMART LED downlight and integrated trim retrofit kit — to be installed by E.C. into rough can purchased and installed by E.C, CREE product available at Home Depot X D-1 General Ceiling-mounted, recessed downlight — 6" diameter fixture 11W of LED @ 50+ Lumens per watt — ; color temp 2,700K Dimmable ECO-SMART LED downlight and integrated trim retrofit kit — to be installed by E.C. into rough can purchased and installed by E.C, Available at Home Depot D-2 NOT USED Ceiling-mounted, recessed downlight — 4" diameter fixture 10W of LED @ 50+ Lumens per watt — ; color temp 2,700K On-off Cree LR4-15 X C-1 Exterior Surface mounted waterproofed bulkhead fixture.On-off (Electrical contractor to propose) (See Detail 3/E1) L-1 Bathroom Wall-mounted, linear fluorescent fixture with wrap-around diffuser Single 24" T5; color temp 3000K; electronic ballast instant start On-off (Fixture to be provided by Owner for installation by Contractor) Mount above mirror, centrally over basin L-2 Hall An ultra-slimline linear fluorescent mounted on wall behind carpenter fabricated valance Double lamped 4' T5; color temp 3000K; electronic ballast instant start On-off (Electrical contractor to propose)Mount fixture 8' 0" above floor level. (See Detail 4/E1) L-3 Closets An ultra-slimline linear fluorescent mounted on wall immediately over door Single 24" T5; color temp 3500K; electronic ballast instant start industrial fixture On-off (Electrical contractor to propose)Mount fixture above door inside closet X L4 Garage Ceiling surface-mounted linear fluorescent strip lighting fixture with wrap- around polycarbonate lens Double 4' 38W T8; color temp 3500K; electronic ballast instant start industrial fixture On-off (Electrical contractor to propose) Similar to Lithonia SB Fixtures to be mounted so as to allow for storage crates to be hoisted into the garage "loft" space M-1 NOT USED Track-mounted spot light 22W LED; color temp. 2700; Dimmable Amerlux 'Hornet-HP-H' line- X R-1 Screened Porch Narrow profile rope-strip with either constructed or proprietary valance.LED "warm white"Dimmable Bruck Ledra 'Orion Belt' 135401 1.25W per ft.; with 40W power supply remotely located Light strip laid in custom fabricated valance trough (See Detail 5/E-1) S-1 Stair Wall mounted LED On-off (Fixture to be provided by Owner for installation by Contractor)Mounting height TBD S-1 Entry Cubby Area Wall mounted LED On-off (Fixture to be provided by Owner for installation by Contractor)Mounting height TBD X X-1 Deck Wall surface mounted fixture; waterproof LED — 30W (3,000K)On-off Cooper Lumark 'Crosstour'; Color: BROWN Mount at 12' 0" above deck level * Not all information on the product is contained in the manufacturer's catalog number. Please read the luminaire description for additional mounting information, ballasting, accessories, etc. * All fixtures to be UL listed. * Electrical contractor shall verify all voltages with Electrical Engineer prior to ordering fixtures * Electrical contractor shall verify ceiling types prior to ordering fixtures * All T5 and T8 lamps to have a CRI greater than 80, initial lumens of 3,000 or greater, and average rated life shall be 24,000 hours or greater. * All T5 and T8 ballasts are to be electronic programmed rapid start and series circuited, unless otherwise noted. Electronic ballasts to have less than 10% THD, >0.88BF, unless otherwise noted. * Required T5 and T8 linear fluorescent efficacy should equal or be greater than 88 Mean Lumens Per Watt (MLPW) for programmed rapid-start ballasts. * NBF = Normal Ballast Factor (BF=0.87) * LBF = Low Ballast Factor (BF = 0.77) * HBF = High Ballast Factor (BF = 1.19) General Notes DN3D3333DSD 3'-6"3'-6"3'-6"3'-6"3'-0"4'-0"5 E2.1 CONNECT TO D-1 FIXTURES & SWITCH AT FRONT ENTRY TO SWITCHED RECEPTACLE, SEE SHEET E-2 POWER PLAN D-1 D-1 D-1 R-1 L-2L-2 L-3 D-1 X-1 X-1 S-1S-1 S-2 S-2 D-1 D-1 D-1 D-1 CL D-1 HALL 11 ELEV. 03 AWAY ROOM 13 DECK 15PORCH SCREENED 14 WOOD VALANCE (PAINT) LIGHT FIXTURE WALLC-1 LIGHT FIXTURE 2X12 FLAT BLOCKING PEICE DECKING 2X10 DECK JOISTS 2"PORCH ROOF FRAMING (2) 2X BLOCKING LED ROPE LIGHT IN MANUFACTURED CHANNEL PORCH CEILING SIDING (2) 2X BLOCKING SCALE: 1/4" = 1'-0"1 LOWER LEVEL LIGHTING PLAN SCALE: 1/4" = 1'-0"2 UPPER LEVEL LIGHTING PLAN SCALE: 3" = 1'-0"3 LIGHTING DETAIL SCALE: 1 1/2"= 1'-0"4 LIGHTING DETAIL SCALE: 3" = 1'-0"5 ROPE LIGHT DETAIL @ PORCH