Loading...
22B-015 56 Meadow St truss profilesOVERHANG INFO HEEL HEIGHT GABLE STUDS 00-04-03 24 IN. OC END CUT RETURN PLUMB NO REQ. ENGINEERING JOBSITE REQ. LAYOUTS JOBSITE 2 1 QUOTE LAYOUT CUTTING BT1 BT1 DATEBY SHIP TO 24 West St Hatfield, MA 01038 R.K. Miles-HatfieldSOLD TO (413) 247-8314 SALES REP ORDER DATE REQ. QUOTE DATE DELIVERY DATE / / / / / /ORDER # QUOTE # TERMS SALES AREA CUSTOMER PO # CUSTOMER ACCT # INVOICE # LMCWRKMI ORDERED BY SUPERINTENDENT JOBSITE PHONE # DATE OF INVOICE 14042587B Brian Tetreault Massachusetts / / / Mike Greaney (413) 247-8314 PAGE 1 SPECIAL INSTRUCTIONS: DELIVERY INSTRUCTIONS: JOB NAME: MODEL: TAG: Meadow St. BUILDING DEPARTMENT Roof Trusses JOB CATEGORY: Residential LOT # SUBDIV: DATE04/17/14 56 Meadow St. Florence, MA Mike Greaney 04/17/14 04/17/14 / / 155 Bay Road, PO Box 945, Belchertown, MA. 01007 Phone: 413-323-7247 Fax: 413-323-5257 UFP Belchertown, LLC QTY TYPE SPAN LUMBER TOP BOT OVERHANG LEFT RIGHT CANTILEVER LEFT RIGHT PITCH TOP BOTID TOTALPRICEPRICEUNITPROFILE ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 65.0,10.0,0.0,10.0 STRESS INCR. 1.15INFORMATION ROOF TRUSS SPACING:24.0 IN. O.C. (TYP.)ROOF TRUSSES LOADING TCLL-TCDL-BCLL-BCDL 65.0,10.0,0.0,10.0 STRESS INCR. INFORMATION PLY LEFT RIGHT STUBO/ABASE SPAN PB0114.00 0.00 08-11-12 2 X 4 2 X 4 GABLE 18 08-11-12 PB01GE14.00 0.00 08-11-12 2 X 4 2 X 4 GABLE 2 08-11-12 S0114.00 14.00 26-00-00 01-06-00 01-06-002 X 4 2 X 4 PIGGYBACK 18 26-00-00 S01SGE14.00 14.00 26-00-00 01-06-00 01-06-002 X 4 2 X 4 GABLE 2 26-00-00 ROOF SUB-TOTAL: ACCEPTED BY BUYER PURCHASER: BY: TITLE: ADDRESS: PHONE: DATE: ACCEPTED BY SELLER BY: TITLE: DATE OF ACCEPTANCE: SUB-TOTAL GRAND TOTAL S01SGES01SGEPB01GEPB01GES01(18)PB01(18)26' 0" 38' 0"2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0" 2' 0"2' 0"Roof Area 62.8Overhang Lines 82Raked Lines 89.12Ridge Lines 41Hip Lines 0Valley Lines 0THIS IS A TRUSS PLACEMENT DIAGRAM ONLY. These trusses are designed as individual building components to beincorporated into the building design at the specificationof the building designer. See individual design sheets for eachtruss design identified on the placement drawing. The building designer is responsible for temporary and permanent bracingof the roof and floor system and for the overall structure. The design of the truss support structure including headers, beams,walls, and columns is the responsibility of the building designer. For general guidance regarding bracing, consult "Bracing ofwood trusses" available from the Truss Plate Institute, 583D'Onifrio Drive; Madison, WI 53179. It is the responsiblility of theGeneral Contractor/Superintendent to verify that the provided truss layout shall match the final intended construction plans,loading conditions, and use. If they do not, it is the responsiblility of the General Contractor/Superintendent to provideprints/plans containing the latest specifications and designs. Universal Forest Products will not be responsible forprint/planchanges by others after final approval ofshop drawings, norwill they be responsible for errors or modifications made on-siteduring construction. DO NOT CUT, NOTCH, DRILL, OR OTHERWISE"REPAIR" MANUFACTURED TRUSSES IN ANY WAYWITHOUT PRIOR WRITTEN AUTHORIZATION BY A LICENSED PROFESSIONAL DESIGNATED BY UFP. UFP WILL NOTBE HELD RESPONSIBLE FOR ANY MODIFICATIONS OR "CHARGE BACKS"DONE WITHOUT PRIOR WRITTENAUTHORIZATION FROM UFPMeadow St.56 Meadow St. Florence, MA4/17/14For Approval14042587BThe following information is anapproximate and NOT guaranteed Job 14042587B Truss S01 Truss Type PIGGYBACK BASE Qty 18 Ply 1 Meadow St. Job Reference (optional)7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Apr 17 12:17:48 2014 Page 1 Universal Forest Products ID:bwvT8WK5_kU0YHNGPdgP6FzPqmm-qRUHjgzbACjw?b_XSuqrLCesWvH4QBcLBgk9QazPqRH Scale = 1:67.6 T1 T2 T1 B1 B2 B1 W3 W4 W5 W6 W6 W5 W4 W3 W1 W1 B3 1 2 3 4 5 6 7 8 9 16 15 14 13 12 11 10 17 18 19 4x6 4x6 8x8 3x4 8x8 5x10 3x8 3x8 3x4 3x8 3x8 5x10 3x8 3x8 0-3-04-6-016-11-7 0-8-0 0-8-0 4-6-5 3-10-5 8-0-0 3-5-11 18-0-0 10-0-0 21-5-11 3-5-11 25-4-0 3-10-5 26-0-0 0-8-0 -1-6-01-6-0 0-8-0 0-8-0 4-6-53-10-5 8-0-03-5-11 13-0-05-0-0 18-0-05-0-0 21-5-113-5-11 25-4-03-10-5 26-0-00-8-0 27-6-0 1-6-0 1-6-010-10-011-6-61-6-00-3-04-6-06-4-014.00 12 14.00 12 Plate Offsets (X,Y): [2:0-4-4,0-2-0], [3:0-2-4,0-1-8], [4:0-3-2,0-2-0], [6:0-3-0,0-1-12], [7:0-2-8,0-1-8], [8:0-4-4,0-2-4], [10:0-1-8,0-1-0], [15:0-4-8,Edge], [16:0-1-8,0-1-0] LOADING (psf)TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACINGPlates Increase Lumber Increase Rep Stress Incr Code 2-0-01.15 1.15 YES IRC2009/TPI2007 CSITC BC WB (Matrix) 0.90 0.63 0.96 DEFLVert(LL) Vert(TL) Horz(TL) Wind(LL) in-0.45 -0.84 1.02 0.10 (loc)12-14 12-14 10 14-15 l/defl>680 >364 n/a >999 L/d240 180 n/a 360 PLATESMT20 Weight: 146 lb FT = 4% GRIP197/144 LUMBERTOP CHORD 2x4 SPF No.2 BOT CHORD 2x4 SPF No.2 *Except* B2,B3: 2x4 SPF 2100F 1.8E WEBS 2x4 SPF No.2 or 2x4 SPF Stud *Except* W2: 2x4 SPF No.2, W1: 2x8 SP No.1 BRACINGTOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins, except end verticals, and 2-0-0 oc purlins (4-2-6 max.): 4-6. BOT CHORD Rigid ceiling directly applied or 9-3-8 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS (lb/size)16=1770/0-3-8 (min. 0-2-14), 10=1770/0-3-8 (min. 0-2-14) Max Horz 16=-270(LC 6)Max Uplift16=-59(LC 8), 10=-59(LC 9)Max Grav16=1830(LC 2), 10=1816(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=0/282, 2-17=-4909/635, 3-17=-4782/651, 3-4=-2613/227, 4-5=-1630/180, 5-6=-1551/137, 6-7=-2454/137, 7-8=-4713/10, 2-16=-1863/306, 8-10=-1837/215BOT CHORD 15-16=-407/472, 14-15=-527/2979, 14-18=-171/1801, 18-19=-171/1801, 13-19=-171/1801,12-13=-171/1801, 11-12=0/2790WEBS2-15=-365/3762, 3-15=-477/2222, 3-14=-1612/396, 4-14=-99/1336, 5-14=-346/190, 5-12=-402/185, 6-12=-24/1367, 7-12=-1484/9, 7-11=0/2088, 8-11=-31/3499 NOTES 1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate gripDOL=1.60 2) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.1, Lu left =14-6-0, Lu right =14-6-0 3) Unbalanced snow loads have been considered for this design. 4) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors.5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.6) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members, with BCDL = 10.0psf. 7) Bearing at joint(s) 16, 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 59 lb uplift at joint 16 and 59 lb uplift atjoint 10.9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1. 10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 11) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 12) The loading on this truss has been modified to reflect the roof profile, the ridgeline is located 5-0-0 from joint 1 and has a slope of14.000 on the left and -14.000 on the right. LOAD CASE(S)Standard Job 14042587B Truss PB01 Truss Type GABLE Qty 18 Ply 1 56 Meadow St. Florence, MA Job Reference (optional)7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Apr 17 12:00:31 2014 Page 1 Universal Forest Products ID:bwvT8WK5_kU0YHNGPdgP6FzPqmm-hxKF45Q6Nb335DCDCckgpXCoJtSeyO0ijq1nXAzPqhU Scale = 1:39.0 T1 T1 B1 ST1 2 3 4 6 1 7 8 5 3x4 3x6 3x4 1.5x3 0-5-14 0-5-14 9-5-11 8-11-12 9-11-9 0-5-14 4-11-13 4-11-13 9-11-9 4-11-13 5-10-00-1-40-1-814.00 12 Plate Offsets (X,Y): [4:0-3-10,Edge] LOADING (psf)TCLL (Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACINGPlates Increase Lumber Increase Rep Stress Incr Code 2-0-01.15 1.15 YES IRC2009/TPI2007 CSITC BC WB (Matrix) 0.32 0.17 0.12 DEFLVert(LL) Vert(TL) Horz(TL) inn/a n/a 0.00 (loc)- - 5 l/defln/a n/a n/a L/d999 999 n/a PLATESMT20 Weight: 33 lb FT = 4% GRIP197/144 LUMBERTOP CHORD 2x4 SPF 2100F 1.8E BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 or 2x4 SPF Stud BRACINGTOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide. REACTIONS All bearings 10-0-0. (lb) - Max Horz 1=-134(LC 6) Max Uplift All uplift 100 lb or less at joint(s) except 1=-782(LC 2), 5=-782(LC 3), 2=-495(LC 8), 4=-457(LC 9)Max Grav All reactions 250 lb or less at joint(s) except 1=458(LC 8), 5=412(LC 9), 2=1198(LC 2), 4=1198(LC 3), 6=307(LC 1) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-466/530, 2-7=-309/70, 4-8=-309/70, 4-5=-466/530 NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 4-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members.10) Bearing at joint(s) 1, 5, 2, 4 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 782 lb uplift at joint 1, 782 lb uplift at joint 5, 495 lb uplift at joint 2 and 457 lb uplift at joint 4.12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 14) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S)Standard Job 14042587B Truss PB01GE Truss Type GABLE Qty 2 Ply 1 56 Meadow St. Florence, MA Job Reference (optional)7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Apr 17 12:00:43 2014 Page 1 Universal Forest Products ID:bwvT8WK5_kU0YHNGPdgP6FzPqmm-LF2obBZeYHaMX37Xv7xUI3iuXjbUmpfTUixPyUzPqhI Scale = 1:39.3 T1 T1 B1 ST2 ST1 ST1 2 3 4 5 6 10 9 8 1 11 12 7 3x4 2x4 2x4 1.5x3 1.5x3 1.5x3 1.5x3 1.5x3 0-5-14 0-5-14 9-5-11 8-11-12 9-11-9 0-5-14 4-11-13 4-11-13 9-11-9 4-11-13 5-10-00-1-40-1-814.00 12 LOADING (psf)TCLL(Roof Snow=40.0) TCDL BCLL BCDL 40.0 10.0 0.0 * 10.0 SPACINGPlates IncreaseLumber Increase Rep Stress Incr Code 2-0-01.151.15 YES IRC2009/TPI2007 CSITCBC WB (Matrix) 0.110.04 0.07 DEFLVert(LL)Vert(TL) Horz(TL) inn/an/a 0.00 (loc)- - 6 l/defln/an/a n/a L/d999999 n/a PLATESMT20 Weight: 40 lb FT = 4% GRIP197/144 LUMBERTOP CHORD 2x4 SPF No.2BOT CHORD 2x4 SPF No.2 OTHERS 2x4 SPF No.2 or 2x4 SPF Stud BRACINGTOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracingbe installed during truss erection, in accordance with StabilizerInstallation guide.REACTIONS All bearings 10-0-0. (lb) - Max Horz 1=-134(LC 6) Max Uplift All uplift 100 lb or less at joint(s) 6 except 1=-139(LC 1), 7=-139(LC 1), 2=-102(LC 7), 10=-107(LC 8), 8=-106(LC 9)Max Grav All reactions 250 lb or less at joint(s) 1, 7, 9 except 2=354(LC 1), 6=354(LC 1), 10=318(LC 2), 8=318(LC 3) FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 3-10=-264/234, 5-8=-264/234 NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2)zone; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes to account for these factors. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.9) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 widewill fit between the bottom chord and any other members.10) Bearing at joint(s) 1, 7, 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 11) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 6 except (jt=lb) 1=139, 7=139, 2=102, 10=107, 8=106.12) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 andreferenced standard ANSI/TPI 1.13) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss. 14) See Standard Industry Piggyback Truss Connection Detail for Connection to base truss as applicable, or consult qualified building designer. LOAD CASE(S)Standard