Loading...
38B-216 1st floor girder calcs(4)CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 1 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.8 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 7' 9.50" 92 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 7' 9.50" 117 139 Live Replacement Uniform (PLF) Top 7' 9.50" 16' 1.50" 125 0 Snow Replacement Uniform (PLF) Top 7' 9.50" 16' 1.50" 138 179 Live Point (LBS) Top 15' 6.38" 35 17 Snow 1 2 3 7 5 8 8 8 0 16 1 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 836# -- 2 7' 5.500" Wall N/A N/A 1.936" 3282# -- 3 16' 1.500" Wall N/A N/A 1.500" 1336# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 364# 288# 346# 2 1211# 1036# 1597# 3 483# 472# 620# Design spans 7' 0.875" 8' 0.875" Product: SYP (PT) #1 2 x 12 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2168.'# 7581.'# 28% 12.3' Even Spans D+0.75(L+S) Negative Moment 2558.'# 7581.'# 33% 7.46' Total Load D+0.75(L+S) Shear 1510.# 4528.# 33% 7.47' Total Load D+0.75(L+S) LL Deflection 0.0212" 0.2691" L/999+ 11.9' Even Spans 0.75(L+S) TL Deflection 0.0366" 0.4036" L/999+ 11.9' Even Spans D+0.75(L+S) Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 2 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG2 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 3.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 23' 7.00" 6 1 Live Replacement Uniform (PLF) Top 1' 3.00" 23' 7.00" 27 7 Live 1 2 3 2 3 0 10 0 0 11 4 0 23 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 3.000" Wall N/A N/A 1.500" 297# -- 2 12' 3.000" Wall N/A N/A 1.500" 596# -- 3 23' 7.000" Wall N/A N/A 1.500" 210# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 216# 81# 2 422# 174# 3 153# 57# Design spans 2' 0.000" (left cant) 10' 0.000" 10' 8.875" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 478.'# 3431.'# 13% 18.69' Odd Spans D+L Negative Moment 617.'# 3431.'# 17% 12.25' Adjacent 2 D+L Shear 270.# 2498.# 10% 12.26' Adjacent 2 D+L LL Deflection 0.0249" 0.3580" L/999+ 18.16' Odd Spans L TL Deflection 0.0319" 0.5370" L/999+ 18.16' Odd Spans D+L LL Defl., Lt. -0.0128" 0.2000" 2L/999+ 0' Even Spans L TL Defl., Lt. -0.0149" 0.2000" 2L/999+ 0' Even Spans D+L Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 3 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG3 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 22' 9.50" 6 1 Live Replacement Uniform (PLF) Top 0' 0.00" 22' 9.50" 27 7 Live 1 2 3 11 4 0 11 5 8 22 9 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 208# -- 2 11' 4.000" Wall N/A N/A 1.500" 630# -- 3 22' 9.500" Wall N/A N/A 1.500" 215# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 153# 55# 2 443# 187# 3 157# 58# Design spans 10' 8.875" 11' 0.875" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 497.'# 3431.'# 14% 17.98' Even Spans D+L Negative Moment 688.'# 3431.'# 20% 11.33' Total Load D+L Shear 282.# 2498.# 11% 11.34' Total Load D+L LL Deflection 0.0276" 0.3691" L/999+ 17.42' Even Spans L TL Deflection 0.0349" 0.5536" L/999+ 17.42' Even Spans D+L Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 4 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 22' 8.00" 220 55 Live 1 2 3 4 7 8 0 7 4 0 7 8 0 22 8 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 872# -- 2 7' 8.000" Wall N/A N/A 1.864" 2376# -- 3 15' 0.000" Wall N/A N/A 1.864" 2376# -- 4 22' 8.000" Wall N/A N/A 1.500" 872# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 702# 170# 2 1895# 481# 3 1895# 481# 4 702# 170# Design spans 7' 0.875" 7' 4.000" 7' 0.875" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1354.'# 3431.'# 39% 18.89' Odd Spans D+L Negative Moment 1636.'# 3431.'# 47% 15' Adjacent 2 D+L Shear 1007.# 2498.# 40% 15.01' Adjacent 2 D+L LL Deflection 0.0342" 0.2358" L/999+ 18.54' Odd Spans L TL Deflection 0.0405" 0.3536" L/999+ 18.89' Odd Spans D+L Control: Negative Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 5 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG5 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 4.4 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 2' 8.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 8.00" 27 7 Live Replacement Uniform (PLF) Top 2' 8.00" 6' 8.00" 3 1 Live 1 2 3 2 6 4 4 1 12 6 8 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 68# 0# 2 2' 6.250" Wall N/A N/A 1.500" 207# -- 3 6' 8.000" Wall N/A N/A 1.500" 64# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 56# 13# 2 152# 55# 3 46# 17# Design spans 2' 3.625" 3' 9.125" Product: Spruce-Pine-Fir #2 2 x 8 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 50.'# 2300.'# 2% 4.78' Even Spans D+L Negative Moment 63.'# 2300.'# 2% 2.52' Total Load D+L Shear 69.# 1958.# 3% 2.53' Total Load D+L LL Deflection 0.0010" 0.1253" L/999+ 4.59' Even Spans L TL Deflection 0.0010" 0.1880" L/999+ 4.59' Even Spans D+L Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 BranchKristenFortSt - Level 6 12-11-14 2:31pm 6 of 6 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcG6 Member Type: Girder Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.8 PLF Filename: Q:\BranchKri Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 0 3 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 5 1 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.50" 31 96 Snow Replacement Uniform (PLF) Top 3' 4.00" 8' 3.50" 240 60 Live Point (LBS) Top 0' 7.13" 0 91 Live Point (LBS) Top 0' 7.13" 141 68 Snow 1 2 8 3 8 8 3 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1208# -- 2 8' 3.500" Wall N/A N/A 1.500" 1486# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 459# 255# 672# 2 870# 115# 616# Design spans 7' 3.750" Product: SYP (PT) #1 2 x 12 2 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2461.'# 6592.'# 37% 4.62' Total Load D+L Shear 1065.# 3938.# 27% 7.18' Total Load D+L LL Deflection 0.0211" 0.2438" L/999+ 4.25' Total Load L TL Deflection 0.0379" 0.3656" L/999+ 4.25' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table