Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
24C-091 wick heating calcs 2011
Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2011-Feb-28 11:07:50Uponor System Design Software 8.0.06 RSU07192 Page 1C:\Users\jim patterson\Documents\Uponor\wick der.rup Calc = MJ8 Front Door faces: N Job:Load Short Form Date:Entire House By: Orchard Valley Heating and Cooling 29 Rattle Hill, Southampton, MA 01073 Phone: 413-527-5812 Fax: 413-527-5922 Email: jimp@orchardvalleyhc.com Web: www.orchardvalleyhc.com Project Information wick derFor: massasoit st, northampton, ma Design Information InfiltrationClgHtg SimplifiedMethod90-2Outside db (°F) TightConstruction quality7572Inside db (°F) 0Fireplaces1574Design TD (°F) M-Daily range 5050Inside humidity (%) 2056Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make n/a Make n/a Trade n/a Trade n/a Model n/a Cond n/a GAMA ID n/a Coil n/a ARI ref no.n/a Efficiency n/a Efficiency n/a Heating input Sensible cooling Btuh0 Heating output Btuh0 Latent cooling Btuh0 Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0 Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0 Static pressure in H2O0 Static pressure in H2O0 Space thermostat n/a Load sensible heat ratio 0 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) AH1 4625 34702 22211 1006 1006 Entire House 4625 34702 22211 1006 1124 Other equip loads 1154 234 Equip. @ 0.95 RSM 21323 Latent cooling 939 TOTALS 4625 35856 22262 1006 1124 Bold/italic values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 2011-Feb-28 11:07:50Uponor System Design Software 8.0.06 RSU07192 Page 1C:\Users\jim patterson\Documents\Uponor\wick der.rup Calc = MJ8 Front Door faces: N Job:Project Summary Date:Entire House By: Orchard Valley Heating and Cooling 29 Rattle Hill, Southampton, MA 01073 Phone: 413-527-5812 Fax: 413-527-5922 Email: jimp@orchardvalleyhc.com Web: www.orchardvalleyhc.com Project Information wick derFor:massasoit st, northampton, ma Notes: Design Information Greenfield, MA, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-2 Outside db °F90Inside db °F72 Inside db °F75Design TD °F74 Design TD °F15Daily range MRelative humidity %50Moisture difference gr/lb20 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh34702 Structure Btuh22211DuctsBtuh0DuctsBtuh0Central vent (48 cfm)1154 Btuh Central vent (48 cfm)Btuh234HumidificationBtuh0BlowerBtuh0PipingBtuh0 Equipment load Btuh35856 Use manufacturer's data nRate/swing multiplier 0.95InfiltrationEquipment sensible load Btuh21323 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Tight0Fireplaces Structure Btuh939DuctsBtuh0CoolingHeatingCentral vent (48 cfm)Btuh19125402540Area (ft²)Equipment latent load Btuh9392041520415Volume (ft³)Air changes/hour 0.210.21 Equipment total load Btuh22262Equiv. AVF (cfm)7171 Req. total capacity at 0.70 SHR ton2.5 Heating Equipment Summary Cooling Equipment Summary Make n/a Make n/a Trade n/a Trade n/aModeln/a Cond n/aGAMA ID n/a Coil n/aARI ref no.n/aEfficiencyn/a Efficiency n/aHeating input Sensible cooling Btuh0Heating output Btuh0 Latent cooling Btuh0Temperature rise °F0 Total cooling Btuh0 Actual air flow cfm0 Actual air flow cfm0Air flow factor cfm/Btuh0 Air flow factor cfm/Btuh0Static pressure in H2O0 Static pressure in H2O0Space thermostat n/a Load sensible heat ratio 0 Job #: Performed for: wick der massasoit st northampton, ma Orchard Valley Heating and Cooling 29 Rattle Hill Southampton, MA 01073 Phone: 413-527-5812 Fax: 413-527-5922 www.orchardvalleyhc.com jimp@orchardvalleyhc.... Scale: 1 : 106 Page 1 Uponor System Design Software 8.0.06 RSU07192 2011-Feb-28 11:12:08 ...on\Documents\Uponor\wick der.rup N 1st floor Room1 Room2 Room3 Job #: Performed for: wick der massasoit st northampton, ma Orchard Valley Heating and Cooling 29 Rattle Hill Southampton, MA 01073 Phone: 413-527-5812 Fax: 413-527-5922 www.orchardvalleyhc.com jimp@orchardvalleyhc.... Scale: 1 : 106 Page 2 Uponor System Design Software 8.0.06 RSU07192 2011-Feb-28 11:12:08 ...on\Documents\Uponor\wick der.rup N 2nd floor Room5 Room6 Room8 Room9 Room10 Room11 Room12 Room4 78 cfm 70 cfm 101 cfm 111 cfm 79 cfm 162 cfm 130 cfm 130 cfm 189 cfm 182 cfm 221 cfm 292 cfm 293 cfm Job #: Performed for: wick der massasoit st northampton, ma Orchard Valley Heating and Cooling 29 Rattle Hill Southampton, MA 01073 Phone: 413-527-5812 Fax: 413-527-5922 www.orchardvalleyhc.com jimp@orchardvalleyhc.... Scale: 1 : 106 Page 3 Uponor System Design Software 8.0.06 RSU07192 2011-Feb-28 11:12:08 ...on\Documents\Uponor\wick der.rup N 3rd flr Room15 Room16 Room17 Room18 Room19Room20 Room21 72 cfm 72 cfm 49 cfm 43 cfm 6 cfm 191 cfm 191 cfm 6 cfm 49 cfm 144 cfm 43 cfm