Loading...
32A-201 garage headers(1)CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12- 5-14 7:41am 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB13 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 2.50" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 10.50" 1 105 Live Replacement Uniform (PLF) Top 0' 0.00" 4' 10.50" 325 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 27 13 Live Replacement Uniform (PLF) Top 0' 2.50" 8' 3.00" 27 7 Live Replacement Uniform (PLF) Top 4' 10.50" 8' 3.00" 1 99 Live Replacement Uniform (PLF) Top 4' 10.50" 8' 3.00" 316 0 Snow 1 2 8 3 0 8 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1884# -222# 2 8' 3.000" Wall N/A N/A 1.500" 1856# -222# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 258# 1317# 567# 2 258# 1299# 556# Design spans 8' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3817.'# 24466.'# 15% 4.13' Total Load D+S Negative Moment 454.'# 21275.'# 2% 4.13' Total Load D+L Shear 1424.# 9081.# 15% 0.06' Total Load D+S TL Deflection 0.0466" 0.4073" L/999+ 4.13' Total Load D+S LL Deflection 0.0326" 0.2715" L/999+ 4.13' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12- 5-14 7:41am 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB14 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 3' 1.56" 1 99 Live Replacement Uniform (PLF) Top 0' 0.00" 3' 1.56" 316 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 27 13 Live Replacement Uniform (PLF) Top 3' 1.56" 8' 3.00" 1 105 Live Replacement Uniform (PLF) Top 3' 1.56" 8' 3.00" 325 0 Snow 1 2 8 3 0 8 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1858# -222# 2 8' 3.000" Wall N/A N/A 1.500" 1886# -222# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 258# 1301# 557# 2 258# 1318# 568# Design spans 8' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 3823.'# 24466.'# 15% 4.13' Total Load D+S Negative Moment 454.'# 21275.'# 2% 4.13' Total Load D+L Shear 1425.# 9081.# 15% 7.38' Total Load D+S TL Deflection 0.0467" 0.4073" L/999+ 4.13' Total Load D+S LL Deflection 0.0327" 0.2715" L/999+ 4.13' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12- 5-14 7:41am 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB15 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 10.38" 1 99 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 10.38" 316 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 6' 6.38" 27 7 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 0 1 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 3.00" 27 13 Live Replacement Uniform (PLF) Top 1' 10.38" 12' 10.38" 1 105 Live Replacement Uniform (PLF) Top 1' 10.38" 12' 10.38" 325 0 Snow Replacement Uniform (PLF) Top 6' 6.38" 14' 3.00" 27 7 Live Replacement Uniform (PLF) Top 12' 10.38" 14' 3.00" 1 99 Live Replacement Uniform (PLF) Top 12' 10.38" 14' 3.00" 316 0 Snow 1 2 14 3 0 14 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 3264# -386# 2 14' 3.000" Wall N/A N/A 1.500" 3269# -386# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 449# 2282# 982# 2 449# 2285# 984# Design spans 14' 1.750" Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 387lbs at bearing 1 and ensure that the structure can resist appropriately. Review gravity uplift reaction force of 387lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11614.'# 24466.'# 47% 7.13' Total Load D+S Negative Moment 1370.'# 21275.'# 6% 7.13' Total Load D+L Shear 2823.# 9081.# 31% 13.49' Total Load D+S TL Deflection 0.4281" 0.7073" L/396 7.13' Total Load D+S LL Deflection 0.2991" 0.4715" L/567 7.13' Total Load S Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives