Member Data
Description: CalcG3 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 2' 2.00" 1 86 Live
Replacement Uniform (PLF) Top 0' 0.00" 2' 2.00" 260 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 0 17 Live
Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 46 0 Snow
Replacement Uniform (PLF) Top 2' 2.00" 8' 10.00" 1 86 Live
Replacement Uniform (PLF) Top 2' 2.00" 8' 10.00" 260 0 Snow
Replacement Uniform (PLF) Top 8' 10.00" 11' 0.00" 1 86 Live
Replacement Uniform (PLF) Top 8' 10.00" 11' 0.00" 260 0 Snow
1 2
11 0 0
11 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 2153# --
2 11' 0.000" Girder N/A N/A N/A 2153# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 5# 1568# 585#
2 5# 1568# 585#
Design spans
10' 3.000"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 5518.'# 24466.'# 22% 5.5' Total Load D+S
Shear 1738.# 9081.# 19% 0.38' Total Load D+S
TL Deflection 0.1068" 0.5125" L/999+ 5.5' Total Load D+S
LL Deflection 0.0778" 0.3417" L/999+ 5.5' Total Load S
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
2 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG6 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 2' 2.00" 1 85 Live
Replacement Uniform (PLF) Top 0' 0.00" 2' 2.00" 259 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 0 17 Live
Replacement Uniform (PLF) Top 0' 0.00" 11' 0.00" 46 0 Snow
Replacement Uniform (PLF) Top 2' 2.00" 8' 10.00" 1 85 Live
Replacement Uniform (PLF) Top 2' 2.00" 8' 10.00" 259 0 Snow
Replacement Uniform (PLF) Top 8' 10.00" 11' 0.00" 1 85 Live
Replacement Uniform (PLF) Top 8' 10.00" 11' 0.00" 259 0 Snow
1 2
11 0 0
11 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 2147# --
2 11' 0.000" Girder N/A N/A N/A 2147# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 5# 1564# 583#
2 5# 1564# 583#
Design spans
10' 3.000"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 5501.'# 24466.'# 22% 5.5' Total Load D+S
Shear 1732.# 9081.# 19% 0.38' Total Load D+S
TL Deflection 0.1065" 0.5125" L/999+ 5.5' Total Load D+S
LL Deflection 0.0776" 0.3417" L/999+ 5.5' Total Load S
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
3 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG7 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 6.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 16.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 21 7 Snow
Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 63 20 Snow
Replacement Uniform (PLF) Top 18' 9.38" 21' 10.50" 21 7 Snow
Replacement Uniform (PLF) Top 18' 9.38" 21' 10.50" 21 7 Snow
Point (LBS) Top 2' 0.00" 0 0 Live
Point (LBS) Top 2' 0.00" 0 0 Snow
Point (LBS) Top 2' 0.00" 31 10 Snow
Point (LBS) Top 18' 11.63" 5 641 Live
Point (LBS) Top 18' 11.63" 1683 0 Snow
1 2
2 2 12 19 7 12
21 10 8 10 11 4Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 2' 2.750" Wall N/A N/A 1.500" 2021# -329#
2 21' 10.500" Wall N/A N/A 1.500" 3328# -256#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 1# 1341# 680#
2 5# 2307# 1021#
Design spans
2' 0.750" (left cant) 21' 6.375"
Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 329lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 257lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 10355.'# 34462.'# 30% 13.79' Total Load D+S
Negative Moment 1823.'# 34462.'# 5% 11.86' Total Load D+S
Shear 2915.# 12905.# 22% 21.28' Total Load D+S
TL Deflection 0.7066" 1.4356" L/365 11.86' Total Load D+S
LL Deflection 0.4796" 1.0767" L/538 11.86' Total Load S
TL Defl., Lt. -0.2045" 0.2749" 2L/241 0' Total Load D+S
LL Defl., Lt. -0.1384" 0.2061" 2L/357 0' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
4 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: TL Defl., Lt.
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
5 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG8 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: -6.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 16.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 1.13" 21 7 Snow
Replacement Uniform (PLF) Top 0' 0.00" 3' 1.13" 21 7 Snow
Replacement Uniform (PLF) Top 3' 1.13" 19' 10.50" -21 -7 Snow
Replacement Uniform (PLF) Top 3' 1.13" 19' 10.50" -21 -7 Snow
Replacement Uniform (PLF) Top 3' 1.13" 19' 10.50" 21 7 Snow
Replacement Uniform (PLF) Top 3' 1.13" 19' 10.50" 21 7 Snow
Replacement Uniform (PLF) Top 3' 1.13" 19' 10.50" 63 20 Snow
Replacement Uniform (PLF) Top 19' 10.50" 21' 10.50" 21 7 Snow
Replacement Uniform (PLF) Top 19' 10.50" 21' 10.50" 21 7 Snow
Point (LBS) Top 2' 10.88" 5 641 Live
Point (LBS) Top 2' 10.88" 1683 0 Snow
Point (LBS) Top 19' 10.50" 0 0 Live
Point (LBS) Top 19' 10.50" 0 0 Snow
Point (LBS) Top 19' 10.50" 31 10 Snow
1 2
19 7 12 2 2 12
21 10 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3328# -256#
2 19' 7.750" Wall N/A N/A 1.500" 2021# -329#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 5# 2307# 1021#
2 1# 1341# 680#
Design spans
21' 6.375" 2' 0.750" (right cant)
Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 257lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 329lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 10355.'# 34462.'# 30% 8.09' Total Load D+S
Negative Moment 1823.'# 34462.'# 5% 10.02' Total Load D+S
Shear 2915.# 12905.# 22% 0.39' Total Load D+S
TL Deflection 0.7066" 1.4356" L/365 10.02' Total Load D+S
LL Deflection 0.4796" 1.0767" L/538 10.02' Total Load S
TL Defl., Rt. -0.2045" 0.2749" 2L/241 21.88' Total Load D+S
LL Defl., Rt. -0.1384" 0.2061" 2L/357 21.88' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
6 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: TL Defl., Rt.
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
7 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG9 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: -6.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 16.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 2' 10.38" 21 7 Snow
Replacement Uniform (PLF) Top 0' 0.00" 2' 10.38" 21 7 Snow
Replacement Uniform (PLF) Top 2' 10.38" 19' 7.75" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 10.38" 19' 7.75" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 10.38" 19' 7.75" 21 7 Snow
Replacement Uniform (PLF) Top 2' 10.38" 19' 7.75" 21 7 Snow
Replacement Uniform (PLF) Top 2' 10.38" 19' 7.75" 63 20 Snow
Replacement Uniform (PLF) Top 19' 7.75" 21' 7.75" 21 7 Snow
Replacement Uniform (PLF) Top 19' 7.75" 21' 7.75" 21 7 Snow
Point (LBS) Top 2' 8.13" 5 638 Live
Point (LBS) Top 2' 8.13" 1678 0 Snow
Point (LBS) Top 19' 7.75" 0 0 Live
Point (LBS) Top 19' 7.75" 0 0 Snow
Point (LBS) Top 19' 7.75" 31 10 Snow
1 2
19 5 0 2 2 12
21 7 12
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3345# -263#
2 19' 5.000" Wall N/A N/A 1.500" 1980# -326#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 5# 2321# 1023#
2 1# 1313# 667#
Design spans
21' 3.312" 2' 0.750" (right cant)
Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 263lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 326lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 9889.'# 34462.'# 28% 8' Total Load D+S
Negative Moment 1794.'# 34462.'# 5% 9.9' Total Load D+S
Shear 2930.# 12905.# 22% 0.39' Total Load D+S
TL Deflection 0.6601" 1.4185" L/386 9.9' Total Load D+S
LL Deflection 0.4475" 1.0639" L/570 9.9' Total Load S
TL Defl., Rt. -0.1937" 0.2749" 2L/255 21.65' Total Load D+S
LL Defl., Rt. -0.1310" 0.2061" 2L/377 21.65' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
8 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: TL Defl., Rt.
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
9 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG10 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 6.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/240 live, L/180 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 16.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 21 7 Snow
Replacement Uniform (PLF) Top 0' 0.00" 2' 0.00" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" -21 -7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 21 7 Snow
Replacement Uniform (PLF) Top 2' 0.00" 18' 9.38" 63 20 Snow
Replacement Uniform (PLF) Top 18' 9.38" 21' 7.75" 21 7 Snow
Replacement Uniform (PLF) Top 18' 9.38" 21' 7.75" 21 7 Snow
Point (LBS) Top 2' 0.00" 0 0 Live
Point (LBS) Top 2' 0.00" 0 0 Snow
Point (LBS) Top 2' 0.00" 31 10 Snow
Point (LBS) Top 18' 11.63" 5 638 Live
Point (LBS) Top 18' 11.63" 1678 0 Snow
1 2
2 2 12 19 5 0
21 7 12 10 9 14Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 2' 2.750" Wall N/A N/A 1.500" 1980# -326#
2 21' 7.750" Wall N/A N/A 1.500" 3345# -263#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 1# 1313# 667#
2 5# 2321# 1023#
Design spans
2' 0.750" (left cant) 21' 3.312"
Product: 1-3/4x11-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 326lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 263lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 9889.'# 34462.'# 28% 13.65' Total Load D+S
Negative Moment 1794.'# 34462.'# 5% 11.74' Total Load D+S
Shear 2930.# 12905.# 22% 21.06' Total Load D+S
TL Deflection 0.6602" 1.4185" L/386 11.74' Total Load D+S
LL Deflection 0.4475" 1.0639" L/570 11.74' Total Load S
TL Defl., Lt. -0.1937" 0.2749" 2L/255 0' Total Load D+S
LL Defl., Lt. -0.1310" 0.2061" 2L/377 0' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
10 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: TL Defl., Lt.
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
11 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG11 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 3.25" 0 32 Live
Replacement Uniform (PLF) Top 0' 0.00" 0' 3.25" 89 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 9' 11.25" -21 -7 Snow
Replacement Uniform (PLF) Top 0' 3.25" 1' 3.25" 0 35 Live
Replacement Uniform (PLF) Top 0' 3.25" 1' 3.25" 96 0 Snow
Replacement Uniform (PLF) Top 1' 3.25" 1' 4.00" 1 84 Live
Replacement Uniform (PLF) Top 1' 3.25" 1' 4.00" 231 0 Snow
Replacement Uniform (PLF) Top 1' 4.00" 1' 9.75" 1 84 Live
Replacement Uniform (PLF) Top 1' 4.00" 1' 9.75" 231 0 Snow
Replacement Uniform (PLF) Top 1' 9.75" 2' 9.75" 1 84 Live
Replacement Uniform (PLF) Top 1' 9.75" 2' 9.75" 231 0 Snow
Replacement Uniform (PLF) Top 2' 9.75" 9' 9.75" 1 84 Live
Replacement Uniform (PLF) Top 2' 9.75" 9' 9.75" 231 0 Snow
Replacement Uniform (PLF) Top 9' 9.75" 24' 10.00" 1 72 Live
Replacement Uniform (PLF) Top 9' 9.75" 24' 10.00" 200 0 Snow
Point (LBS) Top 1' 4.00" 1 251 Live
Point (LBS) Top 1' 4.00" 333 0 Snow
1 2 3
17 9 12 7 0 4
24 10 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 2648# -68#
2 17' 9.750" Wall N/A N/A 1.500" 5535# --
3 24' 10.000" Wall N/A N/A 1.500" 45# -379#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 6# 1781# 867#
2 12# 3857# 1678#
3 0# -262# -116#
Design spans
17' 7.625" 6' 10.125"
Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 380lbs at bearing 3 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 8361.'# 25040.'# 33% 7.23' Total Load D+S
Negative Moment 9301.'# 25040.'# 37% 17.81' Total Load D+S
Shear 2970.# 10898.# 27% 17.58' Total Load D+S
TL Deflection 0.5198" 0.8818" L/407 8.11' Total Load D+S
LL Deflection 0.3613" 0.5878" L/585 8.11' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
12 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
13 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG14 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.25" 1 72 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.25" 200 0 Snow
Replacement Uniform (PLF) Top 14' 10.75" 24' 10.00" -21 -7 Snow
Replacement Uniform (PLF) Top 15' 0.25" 22' 0.25" 1 84 Live
Replacement Uniform (PLF) Top 15' 0.25" 22' 0.25" 231 0 Snow
Replacement Uniform (PLF) Top 22' 0.25" 23' 0.25" 1 84 Live
Replacement Uniform (PLF) Top 22' 0.25" 23' 0.25" 231 0 Snow
Replacement Uniform (PLF) Top 23' 0.25" 23' 6.00" 1 84 Live
Replacement Uniform (PLF) Top 23' 0.25" 23' 6.00" 231 0 Snow
Replacement Uniform (PLF) Top 23' 6.00" 23' 6.75" 1 84 Live
Replacement Uniform (PLF) Top 23' 6.00" 23' 6.75" 231 0 Snow
Replacement Uniform (PLF) Top 23' 6.75" 24' 8.88" 0 35 Live
Replacement Uniform (PLF) Top 23' 6.75" 24' 8.88" 96 0 Snow
Replacement Uniform (PLF) Top 24' 8.88" 24' 10.00" 0 32 Live
Replacement Uniform (PLF) Top 24' 8.88" 24' 10.00" 89 0 Snow
Point (LBS) Top 23' 6.00" 1 251 Live
Point (LBS) Top 23' 6.00" 333 0 Snow
1 2 3
7 0 4 17 9 12
24 10 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 45# -379#
2 7' 0.250" Wall N/A N/A 1.500" 5535# --
3 24' 10.000" Wall N/A N/A 1.500" 2649# -68#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 0# -262# -116#
2 12# 3857# 1678#
3 6# 1782# 868#
Design spans
6' 10.125" 17' 7.625"
Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 380lbs at bearing 1 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 8361.'# 25040.'# 33% 17.6' Total Load D+S
Negative Moment 9301.'# 25040.'# 37% 7.02' Total Load D+S
Shear 2970.# 10898.# 27% 7.03' Total Load D+S
TL Deflection 0.5198" 0.8818" L/407 16.72' Total Load D+S
LL Deflection 0.3613" 0.5878" L/585 16.72' Total Load S
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
10:58am
14 of 14
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives