32A-201 ESR-1864A Subsidiary of  0      000                     Most Widely Accepted and Trusted  ICC‐ES Report ESR‐1864 Reissued 02/2015 This report is subject to renewal 02/2016. ICC‐ES | (800) 423‐6587 | (562) 699‐0543 | www.icc‐es.org ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2015 “2014 Recipient of Prestigious Western States Seismic Policy Council  (WSSPC) Award in Excellence”  Look for the trusted marks of Conformity!   DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION  SECTION: 07 21 00—THERMAL INSULATION  REPORT HOLDER:   RMAX® OPERATING, LLC     13524 WELCH ROAD  DALLAS, TEXAS 75244  EVALUATION SUBJECT:    RMAX® THERMASHEATH®‐3, TSX‐8500 AND TSX‐8510 INSULATION BOARDS  ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright © 2015 Page 1 of 4 1000 ICC-ES Evaluation Report ESR-1864* Reissued February 2015 This report is subject to renewal February 2016. www.icc-es.org | (800) 423-6587 | (562) 699-0543 A Subsidiary of the International Code Council ® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: RMAX® OPERATING, LLC 13524 WELCH ROAD DALLAS, TEXAS 75244-5291 (972) 387-4500 www.rmax.com EVALUATION SUBJECT: RMAX® THERMASHEATH®-3, TSX-8500 AND TSX 8510 INSULATION BOARDS 1.0 EVALUATION SCOPE Compliance with the following codes:  2012, 2009 and 2006 International Building Code® (IBC)  2012. 2009 and 2006 International Residential Code® (IRC)  2012, 2009 and 2006 International Energy Conservation Code® (IECC) Properties evaluated:  Physical properties  Surface-burning characteristics  Thermal resistance  Attic and crawl space installation  Water vapor transmission  Exterior walls in Types I through IV construction 2.0 USES 2.1 Thermasheath®-3: Rmax® Thermasheath®-3 insulation boards are used as nonstructural, thermal insulating materials in types I, II, III, IV and V construction (IBC) and dwellings under the IRC. Thermasheath®-3 insulation boards, when covered by an approved 15-minute thermal barrier, may be used within or on interior walls, roof assemblies, floor assemblies, ceiling assemblies and wall cavities in any construction type. The insulation boards can be used at the perimeter or under flat concrete slab on grade construction, or on the exterior or interior of basement foundation walls in any construction type. They also can be used on the outside faces of exterior walls of Type V-B (IBC) construction or dwellings under the IRC. Thermasheath®-3 insulation boards may be used in attics and crawl spaces without a 15-minute thermal barrier or an ignition barrier required by the code, when installed in accordance with Section 4.2.1. 2.2 TSX-8500 and TSX-8510: Rmax® TSX-8500 and TSX-8510 insulation boards are used as nonstructural, thermal insulating materials in Types I, II, III, IV and V construction (IBC) and dwellings under the IRC. The insulation boards may be used without a thermal barrier within or on interior walls, the inside face of exterior walls, roof assemblies, floor assemblies, ceiling assemblies and wall cavities in any construction type. The insulation boards may also be used at the perimeter or under flat concrete slab on grade construction and on the exterior or interior of basement foundation walls in any construction type. They also may be used on the outside faces of exterior walls of any type construction or dwellings under the IRC. When used in exterior walls in Types I, II, III and IV construction, construction must be in accordance with Section 4.4. TSX-8500 and TSX-8510 insulation boards may be used in attics and crawl spaces without a 15-minute thermal barrier or an ignition barrier required by the code, when installed in accordance with Section 4.3.2. 3.0 DESCRIPTION 3.1 Materials: 3.1.1 General: Rmax® insulation boards are nonstructural, closed-cell, rigid polyisocyanurate, foam plastic insulation boards that are faced on both sides. The foam plastic core has a nominal density of 2 pcf (32 kg/m3). The boards are available in various lengths and widths. 3.1.2 Thermasheath®-3: Thermasheath®-3 insulation boards consist of a polyisocyanurate foam core described in Section 3.1.1, faced on both sides with aluminum foil bonded to kraft paper. The boards have square edges and are available in thicknesses of 1/2 inch to 41/2 inches (12.7 mm to 114 mm). Thermasheath®-3 insulation boards are Type I, Class 1, materials in accordance with ASTM C1289. 3.1.3 TSX-8500: TSX-8500 insulation boards consist of the polyisocyanurate foam core described in Section 3.1.1, with a silver facer consisting of aluminum-foil bonded to *Revised March 2015 ESR-1864 | Most Widely Accepted and Trusted Page 2 of 4 glass-fiber mat on one side. The other side is faced with either aluminum-foil bonded to glass-fiber mat or a sheet consisting of aluminum foil bonded to kraft paper. The boards have square edges and are available in thicknesses of 1/2-inch to 41/2 inches (12.7 mm to 114 mm). TSX-8500 insulation boards are Type I, Class 1, materials in accordance with ASTM C1289. 3.1.4 TSX-8510: TSX-8510 is the same as TSX-8500 except that the silver facer is replaced with a white facer made of the same material. 3.2 Surface-burning characteristics: The Thermasheath®-3 insulation boards have a flame- spread index of 75 or less and a smoke-developed index of 450 or less at a maximum thickness of 41/2 inches (114 mm), when tested in accordance with ASTM E84. The TSX-8500 and TSX-8510 insulation boards have a flame-spread index of 25 or less and a smoke-developed index of 450 or less at a maximum thickness of 41/2 inches (114 mm), when tested in accordance with ASTM E84. 3.3 Thermal Resistance: The insulation boards have thermal resistances, R-values, at a mean temperature of 75°F (24°C), as shown in Table 1. 3.4 Vapor Permeability: At a minimum thickness of 1/2 inch (12.7 mm), the insulation boards have vapor permeance of less than 0.1 perm [5.7x1012 kg/(Pa-s-m2)] when tested in accordance with ASTM E96 (desiccant method) (Procedure A), and qualify as a Class I vapor retarder. 4.0 INSTALLATION 4.1 General: The insulation boards must be installed in accordance with the Rmax® published installation instructions, the applicable code and this report. The manufacturer’s published installation instructions must be available on the jobsite at all times during installation. The insulating boards may be installed on any or all surfaces up to a thickness of 12 inches (305 mm) based on room corner fire testing in accordance with UL 1715, when covered with a minimum ½-inch-thick (12.7 mm) gypsum board complying with the applicable code. Exceptions to the requirement of a thermal or ignition barrier covering are detailed in Section 4.2.1 for Thermasheath-3 or Sections 4.3.1 and 4.3.2 for TSX-8500 and TSX-8510. The insulation boards may be installed in either single or multiple layers up to the maximum thickness. When installed against wood or steel framing, the fasteners must be of sufficient length to penetrate into wood framing a minimum of 3/4 inch (19 mm) or through the steel framing a minimum 29/64 inch (11.4 mm). For cementitious exterior wall coating applications, fasteners for insulations boards thicker than 11/2 inches (38 mm) must take into account for lateral resistance to provide support for the exterior wall coatings. Exterior wall assemblies, exterior finishes or wall covering assemblies must be structurally adequate to resist transverse loads. All walls must be braced in accordance with IBC Sections 2308.9.3 and 2308.12.4 or IRC Section R602.10.3, as applicable. 4.2 Thermasheath®-3 — Installation without a Prescriptive Ignition Barrier: 4.2.1 Attics and Crawl Spaces: Thermasheath®-3 insulation boards, at a maximum thickness of 1 inch (25.4 mm), may be used on walls of attics or crawl spaces with no covering applied to the attic or crawl space side of the foam plastic when installation is in accordance with all of the following conditions: a. Entry to attic or crawl space is only to service utilities, and no storage is permitted. b. There are no interconnecting attic or crawl space areas. c. Air in the attic or crawl space is not circulated to other parts of the building. d. Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, as applicable, except unvented attics are permitted under the conditions prescribed in 2012 IRC Section R806.5 (2009 or 2006 IRC Section R806.4). e. Under-floor (crawl space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. f. Combustion air is provided in accordance with International Mechanical Code® (IMC) Section 701. 4.3 TSX-8500 and TSX-8510: 4.3.1 Installation without a Prescriptive Thermal Barrier: TSX-8500 and TSX-8510 insulation boards may be installed without an approved thermal barrier when the boards are installed on walls only or ceilings only based on room corner fire testing in accordance with UL 1715 (NFPA 286). Without a thermal barrier, the insulation boards may be installed up to a maximum thickness of 41/2 inches (114 mm) on walls only or 12 inches (305 mm) on ceilings only. Insulation boards may be installed in either single or multiple layers up to the maximum thickness. 4.3.2 Installation without a Prescriptive Ignition Barrier - Attics and Crawl Spaces: TSX-8500 and TSX-8510 insulation boards at a maximum thickness of 12 inches ((305 mm) on ceilings only or 4½ inches (114 mm) on walls only with no covering applied to the attic or crawl space side of the foam plastic when installation is in accordance with all of the following conditions: a. Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, as applicable except unvented attics are permitted under the conditions prescribed in 2012 IRC Section R806.5 (2009 or 2006 IRC Section R806.4). b. Under-floor (crawl space) ventilation is provided when required by IBC Section 1203.3 or IRC Section R408.1, as applicable. c. Combustion air is provided in accordance with IMC Section 701. 4.4 Exterior Walls in Types I, II, III, and IV Construction: When TSX-8500 and TSX-8510 are used on exterior walls of Type I, II, III and IV construction, the assembly must comply with 2012 IBC Sections 1403.5 and 2603.5 (2009 and 2006 IBC Section 2603.5) and this section, and the insulation boards must be installed at a maximum thickness of 3 inches (76 mm). The potential heat of the TSX-8500 and TSX-8510 insulation board is 1847 BTU/ft2 (21 MJ/m2) per inch of thickness when tested in accordance with NFPA 259. Wall assemblies complying with this section are described in Table 2. ESR-1864 | Most Widely Accepted and Trusted Page 3 of 4 5.0 CONDITIONS OF USE The Rmax® foam plastic insulation boards described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report and the manufacturer’s published instructions. In the event of a conflict between this report and the manufacturer’s published installation instructions, this report governs. 5.2 The insulation boards must be covered with an approved exterior wall covering, including a water- resistive barrier complying with the IBC Section 1404.2 or IRC Section R703.2, as applicable. 5.3 The wall covering placed over the foam plastic boards must be structurally adequate to resist transverse loads. All walls must be braced in accordance with IBC Sections 2308.9.3 and 2308.12.4 or IRC Section R602.10, as applicable. 5.4 The insulation boards must not be used as a nailing base for exterior siding materials. All nailing must be into the wall framing as required by the siding manufacturer’s instructions or the applicable code. 5.5 Except as described in Sections 4.2.1, 4.3.1 and 4.3.2 the insulation boards must be separated from the interior of the building by an approved thermal barrier of 1/2 inch-thick (12.7 mm) gypsum board or equivalent 15-minute thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC Section R316.4, as applicable.. 5.6 Use of the insulation board in areas where the probability of termite infestation is “very heavy” must be in accordance with 2012 IBC Section 2603.9 (2009 and 2006 IBC Section 2603.8) and 2012 and 2009 IRC Section R318.4 (2006 IRC Section R320.5), as applicable. 5.7 Jobsite certification and labeling of the insulation must comply with 2012 IRC Section N1101.12 (2009 and 2006 IRC Section N1101.4) or 2012 IECC Section C303.1.1 or R303.1 (2009 IECC Section 303.1 and 2006 IECC Section 102.1.1), as applicable. 5.8 The insulation boards are produced by Rmax® in Dallas, Texas; Fernley, Nevada and Greer, South Carolina, under a quality control program with inspection by ICC ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Foam Plastic Insulation (AC12), dated June 2012 (editorially revised August 2013), including testing in accordance with Appendix B. 6.2 Reports of room corner tests in accordance with UL 1715 and NFPA 286. 6.3 Report of potential heat test in accordance with NFPA 259. 6.4 Reports of fire propagation characteristics testing in accordance with NFPA 285. 7.0 IDENTIFICATION The boards are packaged in bundles that bear a label including the name and address of RMAX Operating, LLC, the date of manufacture, the ASTM C1289 type, the surface burning characteristics and the evaluation report number (ESR-1864). TABLE 1—THERMAL RESISTANCE (R-VALUES) FOR THERMASHEATH®-3, TSX-8500 AND TSX-8510 THICKNESS (inches) R-VALUE [(°F ∙ ft.2 ∙ hr.)/Btu] AT 75°F MEAN TEMPERATURE 1 6.0 4.5 32 12 84 For SI: 1 inch = 25.4 mm, 1°F·ft2·hr/Btu = 0.176 m2·K/W, 1°F = 1.8°C+32. ESR-1864 | Most Widely Accepted and Trusted Page 4 of 4 TABLE 2—NFPA 285 COMPLYING EXTERIOR WALL ASSEMBLIES WALL COMPONENT MATERIALS Base Wall System Select option 1, 2 or 3 1. Concrete wall 2. Concrete masonry wall 3. 1 layer – 5/8"-thick Type X gypsum wallboard on interior, installed over steel studs: minimum 3⅝" depth, minimum 20 gauge at a maximum of 24" o.c. with lateral bracing every 4' vertically Floorline Firestopping 4 lb./cu ft. mineral wool in each stud cavity at each floorline – attached with Z-clips. Cavity Insulation Select option 1, 2 or 3 1. None 2. Any noncombustible insulation per ASTM E136 3. Any Fiberglass batt insulation (faced or unfaced) Exterior Sheathing Select option 1 or 2 1. None 2. Minimum 1/2"-thick exterior gypsum board sheathing complying with ASTM C1396. 2Water-Resistive Barrier Applied to Exterior Sheathing Select option 1 or 2 1. None 2. Any water-resistive barrier that has been tested in accordance with NFPA 285. Exterior Insulation Rmax® TSX-8500 and TSX-8510 Rigid Insulation – 3" max. total thickness (single or multiple layers) Exterior Veneer Select option 1, 2, 3, 4, 5 or 6 1. Brick – Nominal 4" clay brick or veneer with maximum 2” air gap behind the brick. Brick ties/anchors 24" o.c. (max) 2. Stucco – Minimum ¾"-thick exterior cement plaster and lath with an optional secondary water- resistive barrier between the exterior insulation and the lath. The secondary WRB shall not be full-coverage asphalt or butyl-based self-adhered membranes. 3. Limestone – Minimum 2"-thick. Any standard installation technique can be used. 4. Natural Stone – Minimum 2"-thick. Any standard installation technique can be used. 5. Terracotta cladding1 – Minimum 11/4"-thick. Any standard installation technique can be used. 6. Metal Composite Material (MCM) Mitsubishi Plastic Composites America, Inc., Alpolic/fr wall panels (see ICC-ES ESR-2653) or Alcoa Architectural Products Reynobond FR 6-mm panels (see ICC-ES ESR-3435) where there is no exterior insulation in the cavity behind the panels. For SI: 1 inch = 25.4 mm 1Fasteners used for securing the terracotta must penetrate through the foam plastic into wood or steel framing and the system must be designed to handle cladding load and wind load per applicable code. 2Water-resistive barriers must comply with the requirements of IBC Section 1404.2.