Loading...
32A-201 2ND FLOOR HEADERSCS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12-11-14 10:59am 1 of 4 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 11.00" 1 105 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 11.00" 319 0 Snow 1 2 6 11 0 6 11 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1464# -- 2 6' 11.000" Wall N/A N/A 1.500" 1464# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4# 1087# 377# 2 4# 1087# 377# Design spans 6' 9.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2493.'# 3946.'# 63% 3.46' Total Load D+S Shear 1132.# 2872.# 39% 6.18' Total Load D+S LL Deflection 0.0558" 0.2271" L/999+ 3.46' Total Load S TL Deflection 0.0752" 0.3406" L/999+ 3.46' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12-11-14 10:59am 2 of 4 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB2 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 0' 6.25" 0 31 Live Replacement Uniform (PLF) Top 0' 0.00" 0' 6.25" 86 0 Snow Replacement Uniform (PLF) Top 0' 6.25" 1' 6.25" 0 35 Live Replacement Uniform (PLF) Top 0' 6.25" 1' 6.25" 96 0 Snow Replacement Uniform (PLF) Top 1' 6.25" 5' 4.75" 0 38 Live Replacement Uniform (PLF) Top 1' 6.25" 5' 4.75" 105 0 Snow Replacement Uniform (PLF) Top 5' 4.75" 6' 1.50" 0 36 Live Replacement Uniform (PLF) Top 5' 4.75" 6' 1.50" 98 0 Snow Replacement Uniform (PLF) Top 6' 1.50" 7' 3.00" 0 31 Live Replacement Uniform (PLF) Top 6' 1.50" 7' 3.00" 85 0 Snow 1 2 7 3 0 7 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 504# -- 2 7' 3.000" Wall N/A N/A 1.500" 496# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 355# 149# 2 1# 349# 147# Design spans 7' 1.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 926.'# 3946.'# 23% 3.62' Total Load D+S Shear 406.# 2872.# 14% 0.06' Total Load D+S LL Deflection 0.0216" 0.2382" L/999+ 3.62' Total Load S TL Deflection 0.0306" 0.3573" L/999+ 3.62' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12-11-14 10:59am 3 of 4 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB4 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 6' 11.00" 1 105 Live Replacement Uniform (PLF) Top 0' 0.00" 6' 11.00" 321 0 Snow 1 2 6 11 0 6 11 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1471# -- 2 6' 11.000" Wall N/A N/A 1.500" 1471# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 4# 1093# 378# 2 4# 1093# 378# Design spans 6' 9.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 2505.'# 3946.'# 63% 3.46' Total Load D+S Shear 1138.# 2872.# 39% 0.06' Total Load D+S LL Deflection 0.0561" 0.2271" L/999+ 3.46' Total Load S TL Deflection 0.0755" 0.3406" L/999+ 3.46' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005 CS Structure™ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 DennoRich51PhillipsPlace - Lev 12-11-14 10:59am 4 of 4 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB5 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.6 PLF Filename: Q:\DennoRich Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 1.50" 0 31 Live Replacement Uniform (PLF) Top 0' 0.00" 1' 1.50" 85 0 Snow Replacement Uniform (PLF) Top 1' 1.50" 1' 10.25" 0 36 Live Replacement Uniform (PLF) Top 1' 1.50" 1' 10.25" 98 0 Snow Replacement Uniform (PLF) Top 1' 10.25" 5' 8.75" 0 38 Live Replacement Uniform (PLF) Top 1' 10.25" 5' 8.75" 105 0 Snow Replacement Uniform (PLF) Top 5' 8.75" 6' 8.75" 0 35 Live Replacement Uniform (PLF) Top 5' 8.75" 6' 8.75" 96 0 Snow Replacement Uniform (PLF) Top 6' 8.75" 7' 3.00" 0 31 Live Replacement Uniform (PLF) Top 6' 8.75" 7' 3.00" 86 0 Snow 1 2 7 3 0 7 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 496# -- 2 7' 3.000" Wall N/A N/A 1.500" 504# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 1# 349# 147# 2 1# 355# 149# Design spans 7' 1.750" Product: Spruce-Pine-Fir #2 2 x 10 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 926.'# 3946.'# 23% 3.62' Total Load D+S Shear 406.# 2872.# 14% 6.48' Total Load D+S LL Deflection 0.0216" 0.2382" L/999+ 3.62' Total Load S TL Deflection 0.0306" 0.3573" L/999+ 3.62' Total Load D+S Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005