Member Data
Description: CalcG1 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 0.63" 192 48 Live
Replacement Uniform (PLF) Top 3' 0.63" 3' 9.50" -63 0 Snow
Replacement Uniform (PLF) Top 3' 0.63" 3' 9.50" 147 -12 Live
1 2
3 9 8
3 9 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 392# --
2 3' 9.500" Girder N/A N/A N/A 352# -16#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 307# -1# 85#
2 290# -25# 62#
Design spans
3' 2.500"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 312.'# 10637.'# 2% 1.9' Total Load D+L
Negative Moment 2.'# 12233.'# 0% 3.18' Total Load D+S
Shear 155.# 3948.# 3% 2.54' Total Load D+L
TL Deflection 0.0012" 0.1604" L/999+ 1.9' Total Load D+L
LL Deflection 0.0010" 0.1069" L/999+ 1.9' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
2 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG2 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 10.63" 47 12 Live
Replacement Uniform (PLF) Top 3' 10.63" 3' 11.50" 47 12 Live
Replacement Uniform (PLF) Top 3' 10.63" 3' 11.50" 126 13 Live
1 2
3 11 8
3 11 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 105# --
2 3' 11.500" Wall N/A N/A 1.500" 105# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 77# 29#
2 77# 29#
Design spans
3' 3.375"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 86.'# 10637.'# 0% 1.93' Total Load D+L
Shear 42.# 3948.# 1% 2.59' Total Load D+L
TL Deflection 0.0010" 0.1641" L/999+ 1.93' Total Load D+L
LL Deflection 0.0010" 0.1094" L/999+ 1.93' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
3 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG3 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 10.75" 0 26 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 6 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 40 13 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 85 85 Snow
Replacement Uniform (PLF) Top 0' 10.75" 7' 0.75" 0 35 Live
Replacement Uniform (PLF) Top 7' 0.75" 7' 10.94" 0 27 Live
1 2
7 10 15
7 10 15
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 945# -215#
2 7' 10.938" Wall N/A N/A 1.500" 946# -215#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 260# 303# 523#
2 260# 303# 524#
Design spans
7' 1.688"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1695.'# 12233.'# 13% 3.96' Total Load D+0.75(L+S)
Negative Moment 386.'# 10637.'# 3% 3.96' Total Load D+L
Shear 687.# 4541.# 15% 0.4' Total Load D+0.75(L+S)
TL Deflection 0.0318" 0.3571" L/999+ 3.96' Total Load D+0.75(L+S)
LL Deflection 0.0142" 0.2380" L/999+ 3.96' Total Load 0.75(L+S)
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
4 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG4 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 10' 9.75" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 9.75" 27 7 Live
Replacement Uniform (PLF) Top 4' 5.75" 6' 7.75" 319 0 Snow
Replacement Uniform (PLF) Top 4' 5.75" 9' 5.75" 1 186 Live
Replacement Uniform (PLF) Top 6' 7.75" 10' 9.75" 319 45 Snow
Replacement Uniform (PLF) Top 9' 5.75" 10' 9.75" 1 262 Live
Point (LBS) Top 0' 4.63" 0 5 Live
Point (LBS) Top 0' 4.63" 248 80 Snow
Point (LBS) Top 4' 8.00" 1 456 Live
Point (LBS) Top 4' 8.00" 856 0 Snow
1 2
10 9 12
10 9 12
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 2137# --
2 10' 9.750" Wall N/A N/A 1.500" 3008# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 270# 1302# 836#
2 272# 1701# 1306#
Design spans
10' 0.500"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 7554.'# 24466.'# 30% 5.41' Total Load D+S
Shear 2366.# 9081.# 26% 9.47' Total Load D+S
TL Deflection 0.1333" 0.5021" L/903 5.41' Total Load D+S
LL Deflection 0.0792" 0.3347" L/999+ 5.41' Total Load S
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
5 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG5 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 1' 5.00" 1 72 Live
Replacement Uniform (PLF) Top 0' 0.00" 1' 5.00" 200 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 40 13 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 0 81 Live
Replacement Uniform (PLF) Top 1' 5.00" 10' 5.75" 1 84 Live
Replacement Uniform (PLF) Top 1' 5.00" 10' 5.75" 231 0 Snow
Replacement Uniform (PLF) Top 1' 9.75" 15' 0.00" -21 -7 Snow
Replacement Uniform (PLF) Top 10' 5.75" 13' 9.25" 0 30 Live
Replacement Uniform (PLF) Top 10' 5.75" 15' 0.00" 78 6 Snow
Point (LBS) Top 0' 4.63" -587 0 Snow
Point (LBS) Top 0' 4.63" -2 -120 Live
Point (LBS) Top 10' 5.00" 1 250 Live
Point (LBS) Top 10' 5.00" 330 0 Snow
Point (LBS) Top 14' 7.38" 0 6 Live
Point (LBS) Top 14' 7.38" 1 70 Live
Point (LBS) Top 14' 7.38" 91 10 Snow
Point (LBS) Top 14' 7.38" 0 109 Live
Point (LBS) Top 14' 7.38" 191 0 Snow
1 2
15 0 0
15 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3240# -385#
2 15' 0.000" Wall N/A N/A 1.500" 3380# -198#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 667# 1032# 1403#
2 669# 1616# 1667#
Design spans
14' 2.750"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 386lbs at bearing 1 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 11811.'# 38167.'# 30% 7.5' Total Load D+0.75(L+S)
Negative Moment 1402.'# 33189.'# 4% 7.5' Total Load D+L
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
6 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Actual Allowable Capacity Location Loading
Shear 2826.# 13622.# 20% 0.4' Total Load D+0.75(L+S)
TL Deflection 0.2930" 0.7115" L/582 7.5' Total Load D+0.75(L+S)
LL Deflection 0.1532" 0.4743" L/999+ 7.5' Total Load 0.75(L+S)
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
7 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG6 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 4' 5.75" 1 105 Live
Replacement Uniform (PLF) Top 0' 0.00" 4' 5.75" 292 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 0 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 6 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 27 7 Live
Replacement Uniform (PLF) Top 4' 5.75" 8' 0.25" 0 25 Live
Replacement Uniform (PLF) Top 4' 5.75" 8' 0.25" 70 0 Snow
Point (LBS) Top 0' 4.63" 0 3 Live
Point (LBS) Top 0' 4.63" 142 46 Snow
1 2
8 0 4
8 0 4
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 1477# --
2 8' 0.250" Wall N/A N/A 1.500" 749# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 121# 1047# 430#
2 119# 509# 239#
Design spans
7' 3.000"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2004.'# 12233.'# 16% 3.65' Total Load D+S
Shear 879.# 4541.# 19% 0.4' Total Load D+S
TL Deflection 0.0372" 0.3624" L/999+ 4.01' Total Load D+S
LL Deflection 0.0259" 0.2416" L/999+ 4.01' Total Load S
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
8 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG9 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 8.88" -63 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 0' 8.88" 148 -12 Live
Replacement Uniform (PLF) Top 0' 8.88" 3' 9.50" 192 48 Live
1 2
3 9 8
3 9 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 352# -16#
2 3' 9.500" Girder N/A N/A N/A 392# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 290# -25# 62#
2 307# -1# 85#
Design spans
3' 2.500"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 312.'# 10637.'# 2% 1.9' Total Load D+L
Negative Moment 2.'# 12233.'# 0% 0.61' Total Load D+S
Shear 155.# 3948.# 3% 0.3' Total Load D+L
TL Deflection 0.0012" 0.1604" L/999+ 1.9' Total Load D+L
LL Deflection 0.0010" 0.1069" L/999+ 1.9' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
9 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG10 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 47 12 Live
Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 126 13 Live
Replacement Uniform (PLF) Top 0' 5.50" 3' 11.50" 47 12 Live
1 2
3 11 8
3 11 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 115# --
2 3' 11.500" Girder N/A N/A N/A 105# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 86# 30#
2 77# 29#
Design spans
3' 3.375"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 87.'# 10637.'# 0% 2.03' Total Load D+L
Shear 42.# 3948.# 1% 2.68' Total Load D+L
TL Deflection 0.0010" 0.1641" L/999+ 2.03' Total Load D+L
LL Deflection 0.0010" 0.1094" L/999+ 2.03' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
10 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG11 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 10.25" 0 27 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 6 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 40 13 Live
Replacement Uniform (PLF) Top 0' 0.00" 7' 10.94" 85 85 Snow
Replacement Uniform (PLF) Top 0' 10.25" 7' 0.25" 0 35 Live
Replacement Uniform (PLF) Top 7' 0.25" 7' 10.94" 0 26 Live
1 2
7 10 15
7 10 15
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 946# -215#
2 7' 10.938" Wall N/A N/A 1.500" 945# -215#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 260# 303# 524#
2 260# 303# 523#
Design spans
7' 1.688"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1695.'# 12233.'# 13% 3.96' Total Load D+0.75(L+S)
Negative Moment 386.'# 10637.'# 3% 3.96' Total Load D+L
Shear 687.# 4541.# 15% 6.81' Total Load D+0.75(L+S)
TL Deflection 0.0318" 0.3571" L/999+ 3.96' Total Load D+0.75(L+S)
LL Deflection 0.0142" 0.2380" L/999+ 3.96' Total Load 0.75(L+S)
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
11 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG12 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 1' 4.00" 1 262 Live
Replacement Uniform (PLF) Top 0' 0.00" 4' 2.00" 321 46 Snow
Replacement Uniform (PLF) Top 0' 0.00" 10' 9.75" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 9.75" 27 7 Live
Replacement Uniform (PLF) Top 1' 4.00" 6' 4.00" 1 186 Live
Replacement Uniform (PLF) Top 4' 2.00" 6' 4.00" 321 0 Snow
Point (LBS) Top 6' 1.75" 1 456 Live
Point (LBS) Top 6' 1.75" 856 0 Snow
Point (LBS) Top 10' 5.13" 0 5 Live
Point (LBS) Top 10' 5.13" 248 80 Snow
1 2
10 9 12
10 9 12
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3017# --
2 10' 9.750" Wall N/A N/A 1.500" 2140# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 272# 1708# 1309#
2 270# 1304# 836#
Design spans
10' 0.500"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 7571.'# 24466.'# 30% 5.41' Total Load D+S
Shear 2373.# 9081.# 26% 0.4' Total Load D+S
TL Deflection 0.1336" 0.5021" L/901 5.41' Total Load D+S
LL Deflection 0.0794" 0.3347" L/999+ 5.41' Total Load S
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
12 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG13 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 4' 6.25" 78 6 Snow
Replacement Uniform (PLF) Top 0' 0.00" 13' 2.25" -21 -7 Snow
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 40 13 Live
Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 0 81 Live
Replacement Uniform (PLF) Top 1' 2.75" 4' 6.25" 0 30 Live
Replacement Uniform (PLF) Top 4' 6.25" 13' 7.00" 1 84 Live
Replacement Uniform (PLF) Top 4' 6.25" 13' 7.00" 231 0 Snow
Replacement Uniform (PLF) Top 13' 7.00" 15' 0.00" 1 72 Live
Replacement Uniform (PLF) Top 13' 7.00" 15' 0.00" 200 0 Snow
Point (LBS) Top 0' 4.63" 0 6 Live
Point (LBS) Top 0' 4.63" 1 70 Live
Point (LBS) Top 0' 4.63" 91 10 Snow
Point (LBS) Top 0' 4.63" 0 109 Live
Point (LBS) Top 0' 4.63" 191 0 Snow
Point (LBS) Top 4' 7.00" 1 250 Live
Point (LBS) Top 4' 7.00" 330 0 Snow
Point (LBS) Top 14' 7.38" -587 0 Snow
Point (LBS) Top 14' 7.38" -2 -120 Live
1 2
15 0 0
15 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3380# -198#
2 15' 0.000" Wall N/A N/A 1.500" 3240# -385#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 669# 1616# 1667#
2 667# 1032# 1403#
Design spans
14' 2.750"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 386lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 11811.'# 38167.'# 30% 7.5' Total Load D+0.75(L+S)
Negative Moment 1402.'# 33189.'# 4% 7.5' Total Load D+L
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
13 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Actual Allowable Capacity Location Loading
Shear 2826.# 13622.# 20% 13.9' Total Load D+0.75(L+S)
TL Deflection 0.2930" 0.7115" L/582 7.5' Total Load D+0.75(L+S)
LL Deflection 0.1532" 0.4743" L/999+ 7.5' Total Load 0.75(L+S)
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
14 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG14 Member Type: Girder Application: Roof
Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 6.50" 0 25 Live
Replacement Uniform (PLF) Top 0' 0.00" 3' 6.50" 70 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 0 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 6 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 8' 0.25" 27 7 Live
Replacement Uniform (PLF) Top 3' 6.50" 8' 0.25" 1 105 Live
Replacement Uniform (PLF) Top 3' 6.50" 8' 0.25" 292 0 Snow
Point (LBS) Top 7' 7.63" 0 3 Live
Point (LBS) Top 7' 7.63" 142 46 Snow
1 2
8 0 4
8 0 4
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 749# --
2 8' 0.250" Wall N/A N/A 1.500" 1477# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 119# 509# 239#
2 121# 1047# 430#
Design spans
7' 3.000"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2004.'# 12233.'# 16% 4.37' Total Load D+S
Shear 879.# 4541.# 19% 6.91' Total Load D+S
TL Deflection 0.0372" 0.3624" L/999+ 4.01' Total Load D+S
LL Deflection 0.0259" 0.2416" L/999+ 4.01' Total Load S
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
15 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG17 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 3.50" 13 3 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 40 13 Live
Replacement Uniform (PLF) Top 3' 3.50" 12' 11.00" 27 7 Live
Point (LBS) Top 0' 4.63" 12 1669 Live
Point (LBS) Top 0' 4.63" 3841 0 Snow
Point (LBS) Top 3' 5.25" -2 0 Snow
Point (LBS) Top 3' 5.25" 307 98 Live
Point (LBS) Top 12' 6.38" 0 162 Live
Point (LBS) Top 12' 6.38" 2 168 Live
Point (LBS) Top 12' 6.38" 463 0 Snow
1 2
12 11 0
12 11 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 5774# --
2 12' 11.000" Wall N/A N/A 1.500" 1380# -36#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 774# 3840# 1932#
2 641# 462# 552#
Design spans
12' 1.750"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2940.'# 10637.'# 27% 5.85' Total Load D+L
Negative Moment 1119.'# 10637.'# 10% 6.46' Total Load D+L
Shear 917.# 3948.# 23% 0.4' Total Load D+L
TL Deflection 0.1610" 0.6073" L/905 6.46' Total Load D+L
LL Deflection 0.1198" 0.4049" L/999+ 6.46' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
16 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG18 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 7' 4.50" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 20' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 7' 4.50" 17' 4.50" 13 3 Live
Replacement Uniform (PLF) Top 17' 4.50" 20' 0.00" 27 7 Live
Point (LBS) Top 7' 2.75" -26 0 Snow
Point (LBS) Top 7' 2.75" 290 75 Live
Point (LBS) Top 17' 6.25" 89 47 Live
1 2 3
15 8 12 4 3 4
20 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 608# --
2 15' 8.750" Wall N/A N/A 1.500" 1633# --
3 20' 0.000" Girder N/A N/A N/A 24# -529#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 429# -10# 179#
2 1131# -29# 502#
3 -420# 14# -108#
Design spans
15' 4.125" 3' 11.750"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 530lbs at bearing 3 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2327.'# 21275.'# 10% 7.23' Odd Spans D+L
Negative Moment 2421.'# 21275.'# 11% 15.73' Total Load D+L
Shear 756.# 7897.# 9% 15.74' Total Load D+L
TL Deflection 0.0746" 0.7672" L/999+ 7.22' Odd Spans D+L
LL Deflection 0.0535" 0.5115" L/999+ 7.22' Odd Spans L
Control: Negative Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
17 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG19 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 5.9 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 12' 11.00" 40 13 Live
Point (LBS) Top 0' 4.63" 0 162 Live
Point (LBS) Top 0' 4.63" 2 168 Live
Point (LBS) Top 0' 4.63" 463 0 Snow
Point (LBS) Top 9' 5.75" -2 0 Snow
Point (LBS) Top 9' 5.75" 307 98 Live
Point (LBS) Top 12' 6.38" 12 1669 Live
Point (LBS) Top 12' 6.38" 3841 0 Snow
1 2
12 11 0
12 11 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 1384# -36#
2 12' 11.000" Wall N/A N/A 1.500" 5782# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 646# 462# 553#
2 809# 3840# 1941#
Design spans
12' 1.750"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 1 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2981.'# 10637.'# 28% 7.07' Total Load D+L
Negative Moment 1119.'# 10637.'# 10% 6.46' Total Load D+L
Shear 944.# 3948.# 23% 11.92' Total Load D+L
TL Deflection 0.1633" 0.6073" L/892 6.46' Total Load D+L
LL Deflection 0.1216" 0.4049" L/999+ 6.46' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
18 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG20 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 20' 0.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 20' 0.00" 27 7 Live
Point (LBS) Top 2' 5.75" 89 47 Live
Point (LBS) Top 12' 9.25" -26 0 Snow
Point (LBS) Top 12' 9.25" 290 75 Live
1 2 3
4 3 4 15 8 12
20 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 16# -592#
2 4' 3.250" Wall N/A N/A 1.500" 1843# --
3 20' 0.000" Wall N/A N/A 1.500" 631# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 -471# 14# -120#
2 1299# -29# 544#
3 447# -10# 184#
Design spans
3' 11.750" 15' 4.125"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 593lbs at bearing 1 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2484.'# 21275.'# 11% 12.77' Even Spans D+L
Negative Moment 2679.'# 21275.'# 12% 4.27' Total Load D+L
Shear 861.# 7897.# 10% 4.28' Total Load D+L
TL Deflection 0.0806" 0.7672" L/999+ 12.78' Even Spans D+L
LL Deflection 0.0583" 0.5115" L/999+ 12.78' Even Spans L
Control: Negative Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
19 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG21 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 9.50" -248 -7 Live
Replacement Uniform (PLF) Top 0' 0.00" 3' 9.50" 47 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 4' 2.88" 212 53 Live
Replacement Uniform (PLF) Top 3' 9.50" 7' 4.63" 47 12 Live
Replacement Uniform (PLF) Top 4' 2.88" 7' 5.50" 212 53 Live
Replacement Uniform (PLF) Top 7' 4.63" 7' 5.50" 47 12 Live
Point (LBS) Top 3' 7.75" -166 -84 Live
Point (LBS) Top 3' 7.75" 15 0 Snow
1 2
7 5 8
7 5 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 971# -735#
2 7' 5.500" Wall N/A N/A 1.500" 1068# -302#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 745# 127# 226#
2 823# 48# 245#
Design spans
6' 8.250"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 736lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 303lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1705.'# 21275.'# 8% 3.8' Total Load D+L
Negative Moment 1113.'# 21275.'# 5% 3.39' Total Load D+L
Shear 737.# 7897.# 9% 6.4' Total Load D+L
TL Deflection 0.0140" 0.3344" L/999+ 3.78' Total Load D+L
LL Deflection 0.0108" 0.2229" L/999+ 3.78' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
CS Structure™ 2.06.13[Build 1]
kmBeamEngine 4.6.1.0
Materials Database 1492
DennoRich51PhillipsPlace - Lev 12-11-14
11:02am
20 of 20
All product names are trademarks of their respective owners
Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG22 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\DennoRich
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 0' 5.50" 47 12 Live
Replacement Uniform (PLF) Top 0' 0.00" 3' 2.63" 212 53 Live
Replacement Uniform (PLF) Top 0' 5.50" 3' 8.00" 47 12 Live
Replacement Uniform (PLF) Top 3' 2.63" 7' 5.50" 212 53 Live
Replacement Uniform (PLF) Top 3' 8.00" 7' 5.50" -248 -7 Live
Replacement Uniform (PLF) Top 3' 8.00" 7' 5.50" 47 0 Snow
Point (LBS) Top 3' 9.75" -166 -84 Live
Point (LBS) Top 3' 9.75" 15 0 Snow
1 2
7 5 8
7 5 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 1068# -302#
2 7' 5.500" Wall N/A N/A 1.500" 971# -735#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 823# 48# 245#
2 745# 127# 226#
Design spans
6' 8.250"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 303lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 736lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1705.'# 21275.'# 8% 3.66' Total Load D+L
Negative Moment 1113.'# 21275.'# 5% 4.06' Total Load D+L
Shear 737.# 7897.# 9% 0.4' Total Load D+L
TL Deflection 0.0140" 0.3344" L/999+ 3.68' Total Load D+L
LL Deflection 0.0108" 0.2229" L/999+ 3.68' Total Load L
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives