11A-006 roof truss-ENGJob
14061444J
Truss
T01
Truss Type
COMMON
Qty
4
Ply
1 41 Chestnut Ave. Leeds, MA
Job Reference (optional)
0001
7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Jul 10 15:56:16 2014 Page 1 Universal Forest Products ID:sL5TyhTKcRXdI13zNKIrolz56VH-ctaRDvMmX4nOubgNS?dRuaDZbCt?vvUbDdzYsZyzRAT
Scale = 1:51.5
T1 T1
B1
W4
W3W3W1W2 W1W2
B1
1
2
3
4
5
6 7
10 9 8
11 12
4x4
4x4 5x8
4x4 4x4
3x4
4x4
3x4
8-6-08-6-0 17-0-08-6-0
-1-0-0
1-0-0
4-6-0
4-6-0
8-6-0
4-0-0
12-6-0
4-0-0
17-0-0
4-6-0
18-0-0
1-0-0
1-4-08-5-01-4-010.00 12
Plate Offsets (X,Y): [2:0-2-0,0-1-4], [6:0-2-0,0-1-4], [9:0-4-0,0-3-0]
LOADING (psf)TCLL(Roof Snow=40.0)TCDL
BCLLBCDL
40.0
17.0
0.0 *10.0
SPACINGPlates IncreaseLumber IncreaseRep Stress IncrCode
2-0-01.151.15YESIRC2009/TPI2007
CSITCBCWB(Matrix)
0.400.580.76
DEFLVert(LL)Vert(TL)Horz(TL)Wind(LL)
in-0.10-0.250.020.01
(loc)9-109-1089
l/defl>999>803n/a>999
L/d240180n/a360
PLATESMT20
Weight: 86 lb FT = 4%
GRIP197/144
LUMBERTOP CHORD 2x4 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 or 2x4 SPF Stud *Except* W4: 2x4 SPF No.2
BRACINGTOP CHORD Structural wood sheathing directly applied or 5-10-1 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size)10=1250/0-5-8 (min. 0-1-15), 8=1250/0-5-8 (min. 0-1-15)Max Horz 10=-158(LC 6)Max Uplift10=-52(LC 8), 8=-52(LC 9)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-337/144, 3-11=-940/188, 4-11=-777/211, 4-12=-777/211, 5-12=-940/188, 5-6=-337/144, 2-10=-489/188, 6-8=-489/188BOT CHORD 9-10=-61/766, 8-9=-17/766WEBS4-9=-160/569, 5-9=-312/170, 3-9=-312/170, 3-10=-929/46, 5-8=-929/46
NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.5) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes toaccount for these factors.6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 10, 8.9) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.10) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S)Standard
7/10/14
JOHN M.PRESLEYCIVILNo. 43029
TER E DSIGER
A
FO
LOISSEF
O
RP
E N G INEERHTLAEWNOMMOC MASS
AC
HUSETTSN
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
Job
14061444J
Truss
T01GE
Truss Type
GABLE
Qty
1
Ply
1 41 Chestnut Ave. Leeds, MA
Job Reference (optional)
0002
7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Jul 10 15:56:17 2014 Page 1 Universal Forest Products ID:sL5TyhTKcRXdI13zNKIrolz56VH-438pQFNOIOvFWlFZ0j8gRnmmVbLzeS0kRHj6O?yzRAS
Scale = 1:52.0
T1 T1
B1
W1 W1
B1
ST4
ST3
ST2
ST1
ST3
ST2
ST1
1
2
3
4
5
6
7
8
9
1011
20 19 18 17 16 15 14 13 12
21 22
4x4
3x4
5x6
17-0-017-0-0
-1-0-0
1-0-0
8-6-0
8-6-0
17-0-0
8-6-0
18-0-0
1-0-0
1-4-08-5-01-4-010.00 12
Plate Offsets (X,Y): [10:0-2-0,0-0-12], [16:0-3-0,0-3-0]
LOADING (psf)TCLL(Roof Snow=40.0)TCDL
BCLLBCDL
40.0
17.0
0.0 *10.0
SPACINGPlates IncreaseLumber IncreaseRep Stress IncrCode
2-0-01.151.15YESIRC2009/TPI2007
CSITCBCWB(Matrix)
0.260.080.36
DEFLVert(LL)Vert(TL)Horz(TL)
in-0.02-0.030.00
(loc)111112
l/defln/rn/rn/a
L/d18080n/a
PLATESMT20
Weight: 90 lb FT = 4%
GRIP197/144
LUMBERTOP CHORD 2x4 SPF No.2BOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 or 2x4 SPF StudOTHERS2x4 SPF No.2 or 2x4 SPF Stud *Except* ST4: 2x4 SPF No.2
BRACINGTOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS All bearings 17-0-0.(lb) - Max Horz 20=-158(LC 6)Max Uplift All uplift 100 lb or less at joint(s) 12, 17, 18, 15, 14 except 20=-105(LC 6), 19=-113(LC 7), 13=-107(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 16 except 20=303(LC 2), 12=303(LC 3), 17=364(LC 2), 18=270(LC 2), 19=285(LC 1), 15=364(LC 3), 14=270(LC 3), 13=285(LC 1)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 5-6=-114/297, 6-7=-114/297, 2-20=-281/116, 10-12=-281/116WEBS6-16=-313/0, 5-17=-324/92, 7-15=-324/92
NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members andforces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualifiedbuilding designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.6) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes toaccount for these factors.7) All plates are 2x4 MT20 unless otherwise indicated.8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).10) Gable studs spaced at 2-0-0 oc.
11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 12, 17, 18, 15, 14 except (jt=lb) 20=105, 19=113, 13=107.14) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
15) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S)Standard
7/10/14
JOHN M.PRESLEYCIVILNo. 43029
TER E DSIGER
A
FO
LOISSEF
O
RP
E N G INEERHTLAEWNOMMOC MASS
AC
HUSETTSN
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
Job
14061444J
Truss
T02
Truss Type
COMMON
Qty
10
Ply
1 41 Chestnut Ave. Leeds, MA
Job Reference (optional)
0003
7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Jul 10 15:56:20 2014 Page 1 Universal Forest Products ID:sL5TyhTKcRXdI13zNKIrolz56VH-Uepx2HPGbJIpNC_8hriN2QOA4pBlrmGB8Fxm?KyzRAP
Scale = 1:68.2
T2 T2
B1
W4
W3
W4
W3
W1
W2
W1
W2
B2
1 2
3 4
5
6 7
89
13 12 11 10
14 15
16 17 18 19 20 21
3x6
4x6
3x6
5x8
4x4
3x4
4x4
3x6
3x10 MT20H 3x10 MT20H
3x6
8-0-08-0-0 16-0-08-0-0 24-0-08-0-0
-1-0-0
1-0-0
5-10-0
5-10-0
12-0-0
6-2-0
18-2-1
6-2-0
24-0-0
5-10-0
25-0-0
1-0-0
1-4-011-4-01-4-010.00 12
Plate Offsets (X,Y): [2:0-3-0,0-1-4], [5:0-3-0,0-1-12], [8:0-3-0,0-1-4], [11:0-4-0,0-3-0]
LOADING (psf)TCLL(Roof Snow=40.0)TCDL
BCLLBCDL
40.0
17.0
0.0 *10.0
SPACINGPlates IncreaseLumber IncreaseRep Stress IncrCode
2-0-01.151.15YESIRC2009/TPI2007
CSITCBCWB(Matrix-M)
0.750.780.52
DEFLVert(LL)Vert(TL)Horz(TL)Wind(LL)
in-0.20-0.310.060.02
(loc)11-1211-121011-12
l/defl>999>932n/a>999
L/d240180n/a360
PLATESMT20MT20H
Weight: 126 lb FT = 4%
GRIP197/144148/108
LUMBERTOP CHORD 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 *Except* W3,W1: 2x4 SPF No.2 or 2x4 SPF Stud
BRACINGTOP CHORD Structural wood sheathing directly applied or 3-9-12 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.WEBS 1 Row at midpt 3-13, 7-10
REACTIONS (lb/size)13=1914/0-5-8 (min. 0-3-0), 10=1914/0-5-8 (min. 0-3-0)Max Horz 13=225(LC 7)Max Uplift13=-60(LC 8), 10=-60(LC 9)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-487/193, 3-4=-1875/345, 4-14=-1698/356, 5-14=-1629/381, 5-15=-1629/381, 6-15=-1698/356, 6-7=-1875/345, 7-8=-486/192, 2-13=-614/225, 8-10=-614/225BOT CHORD 13-16=-88/1399, 16-17=-88/1399, 12-17=-88/1399, 12-18=0/995, 18-19=0/995, 11-19=0/995, 11-20=-56/1399, 20-21=-56/1399, 10-21=-56/1399WEBS5-11=-166/829, 7-11=-473/259, 5-12=-167/829, 3-12=-473/260, 3-13=-1683/70, 7-10=-1683/70
NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members and forces & MWFRS for reactions shown; LumberDOL=1.60 plate grip DOL=1.602) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.13) Unbalanced snow loads have been considered for this design. 4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.5) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes toaccount for these factors.6) All plates are MT20 plates unless otherwise indicated. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL = 10.0psf.9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 10.10) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.11) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S)Standard
7/10/14
JOHN M.PRESLEYCIVILNo. 43029
TER E DSIGER
A
FO
LOISSEF
O
RP
E N G INEERHTLAEWNOMMOC MASS
AC
HUSETTSN
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
Job
14061444J
Truss
T02GE
Truss Type
GABLE
Qty
1
Ply
1 41 Chestnut Ave. Leeds, MA
Job Reference (optional)
0004
7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Jul 10 15:56:21 2014 Page 1 Universal Forest Products ID:sL5TyhTKcRXdI13zNKIrolz56VH-yrNKGdQuMcQg?MYLFZDcbdxTHDiXaH5KMvhJXmyzRAO
Scale = 1:69.7
T2 T2
B1
W1 W1
T1 T1
B2
ST6
ST5
ST4
ST3
ST2
ST1
ST5
ST4
ST3
ST2
ST112
3
4
5 6
7
8
9
10
11
12 13
14
15
16
17
30 29 28 27 26 25 24 23 22 21 20 19 18
3x4
4x4
3x4
3x4 3x4
5x6
24-0-024-0-0
-1-0-0
1-0-0
12-0-0
12-0-0
24-0-0
12-0-0
25-0-0
1-0-0
1-4-011-4-01-4-010.00 12
Plate Offsets (X,Y): [22:0-3-0,0-3-0]
LOADING (psf)TCLL(Roof Snow=40.0)TCDL
BCLLBCDL
40.0
17.0
0.0 *10.0
SPACINGPlates IncreaseLumber IncreaseRep Stress IncrCode
2-0-01.151.15YESIRC2009/TPI2007
CSITCBCWB(Matrix)
0.210.110.29
DEFLVert(LL)Vert(TL)Horz(TL)
in-0.02-0.020.00
(loc)171718
l/defln/rn/rn/a
L/d18080n/a
PLATESMT20
Weight: 147 lb FT = 4%
GRIP197/144
LUMBERTOP CHORD 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 or 2x4 SPF StudOTHERS2x4 SPF No.2 or 2x4 SPF Stud *Except* ST6,ST5,ST4: 2x4 SPF No.2
BRACINGTOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.WEBS 1 Row at midpt 9-24, 8-25, 10-23
REACTIONS All bearings 24-0-0.(lb) - Max Horz 30=225(LC 7)Max Uplift All uplift 100 lb or less at joint(s) 25, 26, 27, 28, 23, 22, 21, 20 except 30=-171(LC 6), 18=-145(LC 7), 29=-158(LC 7), 19=-143(LC 6)
Max Grav All reactions 250 lb or less at joint(s) 29, 19 except 30=291(LC 12), 18=291(LC 12), 24=285(LC 9), 25=395(LC 2), 26=319(LC 2), 27=265(LC 1), 28=278(LC 2),23=395(LC 3), 22=319(LC 3), 21=265(LC 1), 20=278(LC 3)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 7-8=-104/332, 8-9=-120/393, 9-10=-120/393, 10-11=-104/332, 2-30=-275/143, 16-18=-275/123WEBS9-24=-423/0, 8-25=-355/74, 7-26=-279/115, 10-23=-355/74, 11-22=-279/115
NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members andforces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualifiedbuilding designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.6) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes toaccount for these factors.7) All plates are 2x4 MT20 unless otherwise indicated.8) Gable requires continuous bottom chord bearing. 9) Truss to be fully sheathed from one face or securely braced against lateral movement (i.e. diagonal web).10) Gable studs spaced at 2-0-0 oc.
11) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.12) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.13) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 25, 26, 27, 28, 23, 22, 21, 20 except (jt=lb) 30=171, 18=145, 29=158,19=143.
14) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.15) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S)Standard
7/10/14
JOHN M.PRESLEYCIVILNo. 43029
TER E DSIGER
A
FO
LOISSEF
O
RP
E N G INEERHTLAEWNOMMOC MASS
AC
HUSETTSN
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.
Job
14061444J
Truss
T02SGE
Truss Type
GABLE
Qty
1
Ply
1 41 Chestnut Ave. Leeds, MA
Job Reference (optional)
0005
7.430 s Jul 25 2013 MiTek Industries, Inc. Thu Jul 10 15:56:22 2014 Page 1 Universal Forest Products ID:sL5TyhTKcRXdI13zNKIrolz56VH-R1xiTzRX7wYXcW7XoGkr8rTWactDJgmTbZQt3CyzRAN
Scale = 1:74.5
T2 T2
B1
W4
W3
W4
W3
W1
W2
W1
W2
B2
ST3
ST1
ST2
ST1
ST2
ST4 ST5
ST6 ST7
12
3 4
5
6 7
8 9
13 12 11 10
28 29
30 31 32 33 34 35
3x6
4x6
3x4
3x6
5x8
3x6
4x4
3x4
4x4
3x6
3x10 MT20H 3x10 MT20H
3x6
8-0-08-0-0 16-0-08-0-0 24-0-08-0-0
-1-0-0
1-0-0
5-10-0
5-10-0
12-0-0
6-2-0
18-2-1
6-2-0
24-0-0
5-10-0
25-0-0
1-0-0
1-4-011-4-01-4-010.00 12
Plate Offsets (X,Y): [2:0-3-0,0-1-4], [5:0-1-12,0-1-8], [5:0-3-0,0-1-12], [8:0-3-0,0-1-4], [11:0-4-0,0-3-0], [11:0-2-0,0-1-8]
LOADING (psf)TCLL(Roof Snow=40.0)TCDL
BCLLBCDL
40.0
17.0
0.0 *10.0
SPACINGPlates IncreaseLumber IncreaseRep Stress IncrCode
2-0-01.151.15YESIRC2009/TPI2007
CSITCBCWB(Matrix-M)
0.750.780.52
DEFLVert(LL)Vert(TL)Horz(TL)Wind(LL)
in-0.20-0.310.060.02
(loc)11-1211-121011-12
l/defl>999>932n/a>999
L/d240180n/a360
PLATESMT20MT20H
Weight: 178 lb FT = 4%
GRIP197/144148/108
LUMBERTOP CHORD 2x4 SPF 2100F 1.8EBOT CHORD 2x4 SPF No.2WEBS2x4 SPF No.2 *Except* W3,W1: 2x4 SPF No.2 or 2x4 SPF StudOTHERS2x4 SPF No.2 or 2x4 SPF Stud *Except*
ST3,ST4: 2x4 SPF No.2
BRACINGTOP CHORD Structural wood sheathing directly applied or 3-9-12 oc purlins, except end verticals.BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.WEBS 1 Row at midpt 3-13, 7-10
REACTIONS (lb/size)13=1914/0-5-8 (min. 0-3-0), 10=1914/0-5-8 (min. 0-3-0)Max Horz 13=225(LC 7)
Max Uplift13=-60(LC 8), 10=-60(LC 9)
FORCES (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.TOP CHORD 2-3=-487/193, 3-4=-1875/345, 4-28=-1698/356, 5-28=-1629/381, 5-29=-1629/381, 6-29=-1698/356, 6-7=-1875/345, 7-8=-486/192, 2-13=-614/225, 8-10=-614/225
BOT CHORD 13-30=-88/1399, 30-31=-88/1399, 12-31=-88/1399, 12-32=0/995, 32-33=0/995, 11-33=0/995, 11-34=-56/1399, 34-35=-56/1399, 10-35=-56/1399WEBS5-11=-166/829, 7-11=-473/259, 5-12=-167/829, 3-12=-473/260, 3-13=-1683/70, 7-10=-1683/70
NOTES1) Wind: ASCE 7-05; 100mph; TCDL=5.0psf; BCDL=5.0psf; h=24ft; Cat. II; Exp B; enclosed; MWFRS (low-rise) and C-C Exterior(2) zone; cantilever left and right exposed ;C-C for members andforces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.602) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualifiedbuilding designer as per ANSI/TPI 1.3) TCLL: ASCE 7-05; Pf=40.0 psf (flat roof snow); Category II; Exp B; Partially Exp.; Ct=1.14) Unbalanced snow loads have been considered for this design. 5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 40.0 psf on overhangs non-concurrent with other live loads.6) As requested, plates have not been designed to provide for placement tolerances or rough handling and erection conditions. It is the responsibility of the fabricator to increase plate sizes toaccount for these factors.7) All plates are MT20 plates unless otherwise indicated. 8) All plates are 2x4 MT20 unless otherwise indicated.9) Gable studs spaced at 2-0-0 oc.10) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
11) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members,with BCDL = 10.0psf.12) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 13, 10.13) This truss is designed in accordance with the 2009 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
14) "Semi-rigid pitchbreaks including heels" Member end fixity model was used in the analysis and design of this truss.
LOAD CASE(S)Standard
7/10/14
JOHN M.PRESLEYCIVILNo. 43029
TER E DSIGER
A
FO
LOISSEF
O
RP
E N G INEERHTLAEWNOMMOC MASS
AC
HUSETTSN
This truss is to be fabricated per ANSI/TPI quality requirements. Plates shall be of size and type shown and centered at joints unless otherwise noted. This design is based upon parameters shown, and is for an individual
building component to be installed and loaded vertically. Applicability of design parameters and proper incorporation of component is responsibility of the Building Designer. Building Designer shall verify all design
information on this sheet for conformance with conditions and requirements of the specific building and governing codes and ordinances. Building Designer accepts responsibility for the correctness or accuracy of the design
information as it may relate to a specific building. Certification is valid only when truss is fabricated by a UFP company. Bracing shown is for lateral support of truss members only and does not replace erection and
permanent bracing. Refer to Building Component Safety Information (BCSI) for general guidance regarding storage, delivery, erection and bracing available from SBCA and Truss Plate Institute.