Loading...
31A-143 CS Beam CalcCS Structureâ„¢ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 TurkTed37ForbesAve - Level 8 7-21-14 10:19am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Job Information Job Name: 37 Forbes Av Customer Address: Site Address: Ted Tirk/37 Forbes 37 Forbes Ave Member Data Description: CalcB3 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 20.7 PLF Filename: Q:\TurkTed37 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 30' 8.50" 185 62 Live Replacement Uniform (PLF) Top 0' 0.00" 30' 8.50" 185 62 Live Point (LBS) Top 11' 0.50" 3566 1273 Live Point (LBS) Top 18' 2.50" 3980 1529 Live 1 2 3 12 3 8 18 5 0 30 8 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2575# -1106# 2 12' 3.500" Wall N/A N/A 5.061" 19929# -- 3 30' 8.500" Wall N/A N/A 1.500" 5073# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 2257# 319# 2 14439# 5491# 3 3717# 1355# Design spans 12' 0.875" 18' 2.375" Product: 1-3/4x14 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design limits maximum unbraced length to 4.00' on the bottom chord Review gravity uplift reaction force of 1107lbs at bearing 1 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 25006.'# 45294.'# 55% 20.48' Even Spans D+L Negative Moment 29665.'# 45294.'# 65% 12.29' Total Load D+L Negative Unbrcd 29665.'# 34762.'# 85% 12.29' Total Load D+L Shear 9429.# 13965.# 67% 12.3' Total Load D+L TL Deflection 0.5665" 0.9099" L/385 21.39' Even Spans D+L LL Deflection 0.4254" 0.6066" L/513 21.39' Even Spans L Control: Negative Unbrcd DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives