Loading...
31A-143 CS Beam Calc 3rd floor beamCS Structureâ„¢ 2.06.13[Build 1] kmBeamEngine 4.6.1.0 Materials Database 1492 TurkTed37ForbesAve - Level 10 7-21-14 10:22am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Job Information Job Name: 37 Forbes Av Customer Address: Site Address: Ted Tirk/37 Forbes 37 Forbes Ave Member Data Description: CalcB1 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: (See Below) Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF Filename: Q:\TurkTed37 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 30' 8.50" 148 57 Live Replacement Uniform (PLF) Top 0' 0.00" 30' 8.50" 181 67 Live 1 2 3 4 11 0 8 7 2 0 12 6 0 30 8 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2211# -- 2 11' 0.500" Wall N/A N/A 1.500" 5091# -- 3 18' 2.500" Wall N/A N/A 1.500" 5812# -- 4 30' 8.500" Wall N/A N/A 1.500" 2440# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 1580# 631# 2 3816# 1276# 3 4261# 1551# 4 1737# 702# Design spans 10' 9.875" 7' 2.000" 12' 3.375" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. No lateral bracing required along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 6351.'# 21774.'# 29% 24.96' Odd Spans D+L Negative Moment 6459.'# 21774.'# 29% 18.21' Adjacent 2 D+L Negative Unbrcd 6459.'# 21774.'# 29% 18.21' Adjacent 2 D+L Shear 3024.# 9476.# 31% 18.22' Adjacent 2 D+L TL Deflection 0.2056" 0.6141" L/716 24.96' Odd Spans D+L LL Deflection 0.1491" 0.4094" L/988 24.96' Odd Spans L Control: LL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives