Loading...
23A-215 Alderman 36 Beacon St LVLs calcsCS Structure™ 2016.5.1 [Build 2]kmBeamEngine 2016.5.0.2Materials Database 1555 Alderman 36 Beacon St - Level 9- 1-16 12:48pm 1 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: CalcG2 Member Type: Girder Application: Floor Comments: Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.4 PLF Filename: C:\Users\Mik Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End CategoryReplacement Uniform (PLF) Top 0' 0.00" 1' 3.00" 224 112 Snow Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" -53 -13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 0 -7 LiveReplacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 0 3 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 13 13 Live Replacement Uniform (PLF) Top 0' 0.00" 14' 5.75" 27 7 LiveReplacement Uniform (PLF) Top 1' 3.00" 2' 3.00" 204 102 Snow Replacement Uniform (PLF) Top 2' 3.00" 3' 3.00" 184 92 Snow Replacement Uniform (PLF) Top 2' 3.00" 12' 3.00" 0 7 Snow Replacement Uniform (PLF) Top 2' 3.00" 12' 3.00" 27 7 Snow Replacement Uniform (PLF) Top 3' 3.00" 4' 3.00" 164 82 SnowReplacement Uniform (PLF) Top 4' 3.00" 5' 3.00" 144 72 Snow Replacement Uniform (PLF) Top 5' 3.00" 6' 3.00" 124 62 Snow Replacement Uniform (PLF) Top 6' 3.00" 7' 3.00" 104 52 SnowReplacement Uniform (PLF) Top 7' 3.00" 8' 3.00" 84 42 Snow Replacement Uniform (PLF) Top 8' 3.00" 9' 3.00" 64 32 Snow Replacement Uniform (PLF) Top 9' 3.00" 10' 3.00" 44 22 SnowReplacement Uniform (PLF) Top 10' 3.00" 11' 3.00" 24 12 Snow Replacement Uniform (PLF) Top 11' 3.00" 12' 0.25" 6 3 Snow Point (LBS) Top 12' 3.00" 1162 779 Snow 1 2 14 5 12 14 5 12 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift1 0' 0.000" Wall N/A N/A 1.500" 2187# -406# 2 14' 5.750" Girder N/A N/A N/A 2747# -406# Maximum Load Case ReactionsUsed for applying point loads (or line loads) to carrying members Live Snow Dead 1 -368# 1267# 921#2 -368# 1542# 1205# Design spans 13' 10.125" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Review gravity uplift reaction force of 406lbs at bearing 1 and ensure that the structure can resist appropriately.Review gravity uplift reaction force of 406lbs at bearing 2 and ensure that the structure can resist appropriately. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 7004.'# 25040.'# 27% 7.1' Total Load D+S Negative Moment 1407.'# 21774.'# 6% 7.1' Total Load D+L Shear 2717.# 10898.# 24% 13.33' Total Load D+S CS Structure™ 2016.5.1 [Build 2]kmBeamEngine 2016.5.0.2Materials Database 1555 Alderman 36 Beacon St - Level 9- 1-16 12:48pm 2 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Actual Allowable Capacity Location Loading TL Deflection 0.3354" 0.6922" L/495 7.24' Total Load D+S LL Deflection 0.1895" 0.4615" L/876 7.1' Total Load S Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternativesMinimum bearing length requirements at hangared connections depend on the connection style and are not included in this design. CS Structure™ 2016.5.1 [Build 2]kmBeamEngine 2016.5.0.2Materials Database 1555 Alderman 36 Beacon St - Level 9- 1-16 12:48pm 3 of 3 All product names are trademarks of their respective owners Copyright (C) 2016 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: CalcG4 Member Type: Girder Application: Floor Comments: Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 7.3 PLF Filename: C:\Users\Mik Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End CategoryReplacement Uniform (PLF) Top 0' 0.00" 10' 2.75" 100 99 Live Point (LBS) Top 10' 2.75" 1377 956 Snow 1 2 12 5 8 12 5 8 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 1346# -- 2 12' 5.500" Wall N/A N/A 1.500" 2437# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 569# 217# 756# 2 414# 1159# 1257# Design spans11' 8.250" Product: 1-3/4x7-1/4 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 5003.'# 9634.'# 51% 7.98' Total Load D+0.75(L+S)Shear 2433.# 5544.# 43% 11.49' Total Load D+0.75(L+S) TL Deflection 0.5580" 0.5844" L/251 6.81' Total Load D+0.75(L+S) LL Deflection 0.2559" 0.3896" L/547 6.81' Total Load 0.75(L+S) Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives