Loading...
38B-239 (5) 26 OLIVE ST BP-2019-0881 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:38B-239 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0881 Proiect# JS-2019-001468 Est.Cost: $23222.00 Fee:$75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VALLEY SOLAR LLC 077279 Lot Size(sa.ft.): 11935.44 Owner: SCHLICHTING KERRY Zoning: URB(100)/ Applicant: VALLEY SOLAR LLC AT. 26 OLIVE ST Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON:2/14/2019 0:00:00 TO PERFORM THE FOLLOWING WORK:23 PANEL SOLAR ROOF ARRAY - 7.36 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 2/14/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner V(� L La " \ J Department use only City of Nort -� — tus of Permit: y Building DeCu b Cu Driveway Permit 212 Main1 2019 Se er/S ptic Availability Room Wa er/W II Availability Northampton, Sets of Structural Plans hone 413-587-1240 ' INSPF N"p 1 ,PAA O1(_ ot�Site-j Other Specify APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 1.1 Property Address: QThis section to be completed by office 1 Ir\� C r Map O Lot � 3'? Unit N�p(jYID Zone Overlay District Elm 5t.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: , `�� ( 1�`'1 'l� �, Ci L i V r �t> N o I`t�'ICIIYr�1"Ol�.t�119Q('D Nam int Current Mailing Addres n _ Telephone Signature 2.2 Authorized Agent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) Current Mailing Address: 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a) Building Permit Fee 2. Electdcal (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical (HVAC) 5. Fire Protection 6. Total= (1 + 2+ 3+4+ 5) Check Number This Section For Official Use Only Date Building Permit Number: Issued: Signature: Building Commissioner/Inspector of Buildings Date Ihasbrouck @ northamptonma.gov info(C�valleysolar.solar EMAIL ADDRESS (REQUIRED; CONTRACTOR) I Section 4. ZONING All Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DON'T KNOW Q YES IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO Q DON'T KNOW Q YES 0 IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO 0 DON'T KNOW 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist on the property? YES Q NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES Q NO 0 IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES ® NO Q IF YES,then a Northampton Storm Water Management Permit from the DPW is required. i SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [Q Siding [0] Other[X Solar Brief Description of,Pro ose Work: u 1 r Lb �"LA.)-pG Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a. If New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No . I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT Ryan Hoskin as Owner of the subject property hereby authorize Valley Solar LLC to act onrte , in all matters relative to work authorized by this building permit application. J 11/29/2018 Signature of Owner Date Valley Solar LLC as ewRw/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. 1-4 Print Name Signature of Owner/Agent Date i I SECTION 8-CONSTRUCTION SERVICES 7 8.1 Licensed Construction Supervisor: Not rApplicable ;❑ Name of License Holder: .�—Uq l a11,1 License Number i 1369:0 Addres !� Expiration Date Signature Telephone 413-584-8844 9. Registered Home Improvement Contractor: Not Applicable ❑ 13b&39 Company Name Registration Number Valley Solar LLC Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 I 2,-6 SECTION 10-WORKERS' COMPENSATION INSURANCE AFFIDAVIT(M.G.L. c. 152, § 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes.......V No...... ❑ yl. City of Northampton �Z1.�L�ir1 i Massachusetts ` DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street *Municipal Building h"^"^ Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: � L 011ve 5k- NoWh4M—?1W -bil,3D (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) Signature f it Applicant or Owner Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. A ® DATE(MM/ Y) CERTIFICATE OF LIABILITY INSURANCE 0„30,20,92019 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND,EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S),AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder is an ADDITIONAL INSURED,the policy(ies)must have ADDITIONAL INSURED provisions or be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s). PRODUCER CONTACT Barbara Grynkiewicz NAME: Webber&Grinnell PHONE (413)586-0111 FAX (413)586-6481 AIC No Ext): A/C,No): 8 North King Street E-MAIL bgrynkiewicz@webberandgrinnell.com ADDRESS: INSURER(S)AFFORDING COVERAGE NAIC# Northampton MA 01060 INSURER A: Arbella Protection 41360 INSURED INSURER B: WCAR-Liberty Mutual Valley Solar,LLC. INSURER C: Attn:Steven Silverman INSURER D: P O BOX 60627 INSURER E: Florence MA 01062 INSURER F: COVERAGES CERTIFICATE NUMBER: Exp 2/1/20 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR AIJUL bUtSK POLICY EFF POLICY EXP LTR TYPE OF INSURANCE INSD WVD POLICY NUMBER MMIDDIYYYY MM/DD/YYYY LIMITS X COMMERCIAL GENERAL LIABILITY EACH OCCURRENCE $ 1,000,000 CLAIMS-MADE �OCCUR PREMISES Ea occurrence $ 100,000 MED EXP(Any one person) $ 5,000 A 8500063755 02/01/2019 02/01/2020 PERSONAL&ADV INJURY $ 1,000,000 GEN'L AGGREGATE LIMIT APPLIES PER: GENERAL AGGREGATE $ 2,000,000 POLICY ❑X ECT ❑LOC PRODUCTS-COMPIOPAGG $ 2,000,000 OTHER: $ AUTOMOBILE LIABILITY COMBINED SINGLE LIMIT $ 1,000,000 Ea accident ANY AUTO BODILY INJURY(Per person) $ AOWNED IX SCHEDULED 1020037691 02/01/2019 02/01/2020 BODILY INJURY(Per accident) $ AUTOS ONLY AUTOS XHIRED NON-OWNED PROPERTY DAMAGE $ AUTOS ONLY AUTOS ONLY Per accident Uninsured motorist BI $ 100,000 X UMBRELLA LIAB 1 X OCCUR EACH OCCURRENCE $ 5,000,000 A EXCESS UAB CLAIMS-MADE 4600063756 02/01/2019 02/01/2020 AGGREGATE $ 5,000,000 DED I X RETENTION$ 10,000 $ WORKERS COMPENSATIONX PER OTH- AND EMPLOYERS'LIABILITY STATUTE E v/N R 500,000 B ANY PROPRIETOR/PARTNER/EXECUTIVE NIA WC531S620647019 02/01/2019 02/01/2020 E.L.EACH ACCIDENT $ OFFICER/MEMBER EXCLUDED? 500,000 (Mandatory in NH) E.L.DISEASE-EA EMPLOYEE $ If yes,describe under 500,000 DESCRIPTION OF OPERATIONS below E.L.DISEASE-POLICY LIMIT $ DESCRIPTION OF OPERATIONS/LOCATIONS I VEHICLES (ACORD 101,Additional Remarks Schedule,may be attached If more space Is required) CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF,NOTICE WILL BE DELIVERED IN ***Insurance Information Only*** ACCORDANCE WITH THE POLICY PROVISIONS. AUTHORIZED REPRESENTATIVE ©1988.2015 ACORD CORPORATION. All rights reserved. ACORD 25(2016/03) The ACORD name and logo are registered marks of ACORD i i i The Commonwealth of Massachusetts I Department of Industrial Accidents Office of Investigations 600 Washington Street *' Boston, MA 02111 www.massgov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name(Business/Organization/Individual):Valle;_Solar__ Address: 340 Riverside Drive PO BOX 60627 City/State/Zip: Florence, MA 01062 Phone #: 413-584-8844 Are you an employer?Check the appropriate box: Type of project(required): I.V I am a employer with 6 4. ❑ I am a general contractor and I employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.❑ I am a sole proprietor or partner- listed on the attached sheet. 7. ❑ Remodeling ship and have no employees These sub-contractors have g. ❑ Demolition workingfor me in an capacity. employees and have workers' y p ty• ' 9. ❑ Building addition [No workers' comp. insurance comp. insurance.* required.] 5. ❑ We are a corporation and its 10.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑ Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.❑ Roof repairs insurance required.] t c. 152, §1(4), and we have no employees. [No workers' 13.❑ Other comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy information. t Homeowners who submit this affidavit indicating they are doing all work and then hire outside contractors must submit a new affidavit indicating such. +Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. 1 am an employer that is provirdinl; workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: Liberty Mutual Policy#or Self-ins. Lic. #: WC531 S620647019 Expiration Date: 2/01/2018 Job Site Address: 26 Olive St City/State/Zip:Northampton. MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a tine up to$1,500.00 and/or one-year imprisonment. as well as civil penalties in the form of a STOP WORK ORDER and a tine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify er the pains a d penalti o� rjury that the information provided above is true and correct. S i mature: `' `'l/` Date: 2` t Rhone ; Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1. Board of Health 2. Building Department 3.City/Town Clerk 4. Electrical Inspector S. Plumbing Inspector 6.Other Contact Person: Phone#: i I Vreeland Design Associates An integrative approach to design engineering and site planning Date: February 5, 2019 To: Patrick Rondeau Valley Solar 340 Riverside Drive Northampton, MA 01062 From: David Vreeland, P.E. Vreeland Design Associates Re: Ryan Hoskin and Kerry Schlichting, 26 Olive St,Northampton, MA: Structural assessment of existing carriage garage/studio hip roof to support proposed solar arrays. I have investigated the existing roof framing in the area of the proposed PV solar panel installations. The 1-story detached, 28'x42' carriage garage/studio was constructed/renovated around 1990. The hip style roof is framed with 2x6 rafters, installed at 191/2"�E on-center, spanning 13', with a roof pitch of 7/12. 2x8 ceiling joists are installed at 39"+-on-center and are attached to the rafters preventing the roof from spreading. The hip rafters are 2x 12. 18 solar panels are proposed on the long southwest facing roof and 6 solar panels on the southeast facing hip roof. The rafters longer than 11'-3"along the slope and the hip rafters supporting the solar panels need to be reinforced. Reinforce the rafters by sistering 2x8x10' centered along the length of the existing rafters. Attach the new 2x8 with 2— IOd common nails (3-IOd nailgun nails)at 12"on- center, or 2—TimberLok screws at 24"on-center. Reinforce the hip rafter by installing a 3 —2x4 post approximately 5'-6" from the ridge. The center 2x4 is directly under the hip rafter and the outer 2x4s extend up along the sides of the hip rafter. The post is supported on the existing 2x8 joist, reinforced with 2—new 2x8s sistered to the side of the existing joist,which is located directly above a bearing wall below. I have reviewed the mounting details for the proposed array. Based on a PV panel unit weight of 38f lbs,with the attachment points of the array placed at a maximum of 40"on center and staggered to minimize the load to any one rafter,the reinforced roof framing, as outlined above, is adequate to support the proposed PV solar arrays and the snow and wind load requirements of the current MA State Building Code. Please contact me if you have any questions or need additional information. Sincerely, ����k�OF At4S. DAVID A. yG {4� / VR ,? EELAND jl,��,,,�� CIVIL No.46317 David Vreeland, PE X90 9FQ18TSP�o Vreeland Design Associates s�ONAL 116 River Road, Leyden, MA 01337 Phone: (413) 62.4-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 I 4 I LG325N1 K-A5 LG320N1 K-A5 LIS 315N1 K-A5 325W 320W 315W The LG NeON®2 is LG's best-selling solar module.The NeON°2 received the acclaimed 2015 Intersolar AWARD for featuring LG's Cello Technology, which increases power output and reliability and makes the NeON®2 one of the most powerful and versatile modules on the market. SIV. CE » s ,. Intertek Feature Enhanced Performance Warranty High Power Output LG NeONO'2 has an enhanced performance Compared with previous models,the LG NeONI'2 warranty.The annual degradation has fallen from Black has been designed to significantly enhance its -0.6%/yr to-0.5%/yr.Even after 25 years,the output efficiency,thereby making it efficient even in cell guarantees 2.4%more output than the limited space. previous LG NeON®2 modules. Roof Aesthetics Outstanding Durability LG NeONO 2 Black has been designed with With its newly reinforced frame design,LG has aesthetics in mind,using thinner wires that appear extended the warranty of the NeMe 2 from all black at a distance. 15 years to 25 years,including labor.In addition, LG NeON©2 can endure a front load up to 6000 Pa,and a rear load up to 5400 Pa. Improved Performance on Sunny Days Near Zero LID(Light Induced Degradation) �- LG NeON°2 Black now performs better on ---' The n-type cells used in LG NeON°2 have sunny days,thanks to its improved almost no boron.This leads to less LID(Light temperature coefficient. Induced Degradation)right after installation. LG Ne O N' 2 Buck LG325N1K-A5 LG320NlK-A5 LG315N1K-A5 Mechanical Properties Electrical Properties(STC*) - _-_- ----_---- _...___ Cells 6x10 Model LG325N1K-A5 LG320N1K-A5 LG315N1K-A5 Cell Vendor LG Maximum Power(Pmax) [W] 325 320 315 Cell Type Monocrystalline!N-type MPP Voltage(Vmpp) [V] 33.7 333 32.9 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) (A) 9.65 9.62 9.58 a of Busbar 12(Multi Wire Busbar) Open Circuit Voltage(Voc) [V] 40.9 40.8 40.7 Dimensions(L x W x H) 1,686 x 1,016 x 40 mm Short Circuit Current(Isc) [A] 10.23 10.19 10.15 66.38 x 40 x 1.57 in Module Efficiency [%] 19.0 18.7 18.4 Front Load 6,OOOPa/125 psf* Operating Temperature Rear Load 5,400Pa/113 psf* Maximum System Voltage [V] 1000(UL/IEC) - - Weight 18 kg/39.68 Ib Maximum Series Fuse Rating [A] 20 Connector Type MC4(MC),PV-JM601A(JMTHY) - - ___. -.. Power Tolerance. [%) 0-+3 Junction Box IP68 with 3 Bypass Diodes °C- _.__.. `5TC(StandardTestCondition).Irradiance cet000W/m',celltemperature25 ,AMtS Cables 1,000 mm x 2 ea/39.37 in x 2 ea The nameplate power output is measured and determined by LG Electronics at its sole and absolute Glass Tempered Glass with AR Coating discretion. Frame Anodized Aluminium --- - - -- - - Electrical Pro erties NOCT* 'Please refer to the installation manual for the details. ---------�-------- ----- Model LG325NIK-AS LG320N1K A5 LG31SN1K-AS Certifications and Warranty _ Maximum Power(Pmax) [VJ] 240 236 232 IEC 61215,IEC 61 730-1/-2MPPVoIta Voltage Vm( pp) [V] 31.2 30.8 30.4 UL 1703 MPP Current(Impp) [A) 7.69 7.67 7.63 Certifications IEC 61701(Salt mist corrosion test) Oen Circuit Voltage Voc P 9 ( ) lvj 38.1 38.0 37.9 IEC 62716(Ammonia corrosion test) _ Short Circuit Current(Isc) ! [A] 8.23 8.20 8.17 ISO 9001 •NOCT(Nominal Operating Cell Temperature):Irradiance 800 W/m',ambient temperature Module Fire Performance Type 2(UL 1703) 20•C,wind speed 1 m/s Fire Rating Class C(ULC/ORD C 1703,IEC 61730) Dimensions(mm/inch) Product Warranty 2S Years Output Warranty of Pmax Linear Warranty' '1)1st year 98%,2)After 1st year.0.5%p annual degradation,3)86%for 25 years Temperature Characteristics NOCT [ *C 1 45 t 3 Pmax [%/•C] - -0.37 Voc [%/•C] -0.27 - - 89/\1 Isc [%/`C] 0.03 9)6/384 Characteristic Curves eu/e� 1-194 cc+e66wxekl�e,9\ •LLS Alo,nth,g IwN,�M)-� trek kng,� F x _ 5 i � € S€ B F - � 5 Pmax I =x; *The distance between the center of the mounting/grounding holes. Enphase The high-powered smart grid-ready Enphase IQ 7 Micro'N and Enphase IQ 7+ Micro'M IQ 7 and IQ + dramatically simplify the installation process while achieving the highest system efficiency. Microinverters Part of the Enphase IQ System,the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy", Enphase IQ Battery", and the Enphase Enlighten" monitoring and analysis software. IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years. Easy to Install Lightweight and simple • Faster installation with improved,lighter two-wire cabling iu�iY I� Built-in rapid shutdown compliant(NEC 2014&2017) Productive and Reliable • Optimized for high powered 60-cell and 72-cell*modules • More than a million hours of testing Class II double-insulated enclosure • UL listed eENPHASE Smart Grid Ready a • Complies with advanced grid support,voltage and frequency ride-through requirements Remotely updates to respond to changing grid requirements • Configurable for varying grid profiles Meets CA Rule 21 (UL 1741-SA) UL *The IQ 7+Micro is required to support 72-cell modules. To learn more about Enphase offerings,visit enphase.com v EN PHAS E Enphase IQ 7 and IQ 7+ Microinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US Commonly used module pairings' 235W-350W+ 235W-440W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules Maximum input DC voltage 48V 60 V Peak power tracking voltage 27V-37V 27 V-45 V Operating range 16V-48V 16 V-60 V Min/Max start voltage 22V/48V 22 V/60 V Max DC short circuit current(module Isc) 15A 15A Overvoltage class DC port II 11 DC port backfeed current 0 A 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; AC side protection requires max 20A per branch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak output power 250 VA 295 VA Maximum continuous output power 240 VA 290 VA Nominal(L-L)voltage/rangez 240 V/ 208V/ 240 V/ 208V/ 211-264 V 183-229 V 211-264 V 183-229 V Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Nominal frequency 60 Hz 60 Hz Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms Maximum units per 20 A(L-L)branch circuit3 16(240 VAC) 13(208 VAC) 13(240 VAC) 11 (208 VAC) Overvoltage class AC port III III AC port backfeed current 0 A 0 A Power factor setting 1.0 1.0 Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 97.6% 97.6% 97.5% 97.3% CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% MECHANICAL DATA Ambient temperature range 40°C to+65°C Relative humidity range 4%to 100%(condensing) Connector type(IQ7-60-2-US&IQ7PLUS 72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC-5 adapter) Connector type(IQ7-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or UTX connectors: PV2 to MC4:order ECA-S20-S22 PV2 to UTX:order ECA-S20-S25 Dimensions(WxHxD) 212 mm x 175 mm x 30.2 mm(without bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations Yes Pollution degree PD3 Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor FEATURES Communication Power Line Communication(PLC) Monitoring Enlighten Manager and MyEnlighten monitoring options. Both options require installation of an Enphase IQ Envoy. Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-SA) UL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO.107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. 1.No enforced DC/AC ratio.See the compatibility calculator at hStpsJlenpita�e c4Cnlet_.�sLSSlpR4[3LrzloSluleS�ppaSility. 2.Nominal voltage range can be extended beyond nominal if required by the utility. 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. To learn more about Enphase offerings,visit enphase.com v E N P H A S E. ,;'2018 Enphase Energy All rights reserved.All trademarks or brands used are the property of Enphase Energy,Inc. 2018 05 24 REVISION: SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT _ NOTES: —_ -STANDARD LAG BOLT SPEC ASSUMES — 5/16" LAG BOLTS WITH 2.5" _ EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL A' HARDWARE TO THE FOLLOWING: ROOF RAFTERS OR -SILVER S.S. 10-16 FT-LBS STRUCTURAL MEMBERS - BLACK S.S. 7-9 FT-LBS / RAIL CAN MOUNT TO EITHER SIDE OF POST(UPSLOPE vs. DOWNSLOPE) SNAPNRACK MODULE - FOR UNEVEN ROOF SURFACES, USE UP TO TWO LEVELING SPACERS PER L1 MID CLAMPS r MODULE OVERHANG FOOT OR STANDOFF. SEE DRAWING / �� _ / (NOT TO EXCEED 30% "STANDARD RAIL LEVELING" FOR ///// T I OR MANUFACTURER'S DETAILS AND LIMITATIONS RECOMMENDATIONS) / 1 / e MODULE OVERHANG A/, STANDOFFS ARE BOLTED Ly!/ INTO ROOF RAFTERS OR STRUCTURAL MEMBER / "RAIL SPAN" DISTANCE BETWEEN ROOF ATTACHMENTS LL "RAIL END OVERHANG" (NOT TO EXCEED 34%OF ACCEPTABLE RAIL SPAN) nMAINSTREAM ENERGY CORP DESIGNER: G McPheeters SCALE: DNS PART NUMBER: DESCRIPTION: REV DRAFTER: D Ryan S100 D05 SERIES 100 TYPICAL LAYOUT F PM DATE: G�noufflima oyefomTm ate. a m. APPROVED BY: 120113 PLAN LEGEND cf Utility tient: t (23)LG320N1K-A5 SOLAR PANELS Kerry Schlichting a SNAPNRACK SERIES 100 RACKING 26 Olive St, i Northampton,MA 01060 a a GARAGE °w (23)ENPHASEIQ7PLUS MICRO-INVERTERS m U E L fn O t HOUSE INTERIOR s MAIN MAIN PANEL(E) =N SCsc SOLAR PV COMBINER BOX(N) s o N 9 g HOUSE EXTERIOR Df N N N g ACI AC DISCONNECT(N) UTILITY METER(E) MASGM MA SMART GEN METER(N) a ps ' HOUSE �E$N —6 S7- MAI An = SC M ASG :~ �o a� r/ea penia IM propmt wwe A-dV ylin"•Imwowmenl,Inc.(mo It arri ereoa.meIimfeOeM exnwiw WrPea•ds„ppomrp Me rod/ende orVNI,alM nitlwwr agrwa mat pie alenreMsdpYS pen eltW nota r ,iM.MI•C Orpnseded in eny lawn for me puryoae d enabling w auppoMlry me wnm dcanpeen9 plo/ec1 mneecrors whom me penpssion o/,an0 netper�utlan peie ro,VHI. m <i • j 67 m _ m y � ao 3 � o x 0 ro n o r_ m i �7 �r e� u a IS, rn f72 Cn p ' o 00 Opp n J 1J ll 01 11 m U `t1 �rrl t• Zi 131 II td, Ifi 13 '° l w "' n%• rn 'rt _3 int Valley Solar LLC 1340 Riverside Drive SITE NAME Ryan Hoskin&Kerry Schlichting S"LE:SEE w1 SHEET NUMBER kV, alley PO Box 60627 1 Northampton PLOT LINES SITE ADDRESS 26 Olive St DATE:12/12/18 S lar MA 010621413.584.6844 Northampton.MA 01 —.ValeySolar.Solar SYSTEM SIZE tAb KVP61;6.bf KWAL, onAwN.lws ELEC:RDM/B 14JI I 1 i Inverter Trip Settinas: Eauipment ScheduleO Labelina Schedule Inverter TRIP settings are set in the inverter per the ISO NE �_ M L— SRD and ESB 756 section 7.6.11. 1 PV ARRAY(Series 100)Snap N Rack Roof Mount 1 CAUTION!AC VOLTAGE DEVICE DEFAULT DEFAULT Pickups and System 2 WARNING!PHOTOVOLTAIC POWER SOURCE PICKUP CLEARING TIME clearing Times a 2 SOLAR PV MODULE(LG320N 1 K-A5)(23)LG320W 3 SOLAR PV AC COMBINER BOX SETTING (seconds) Adhere to s 3 e panels. 4 SOLAR PV AC CIRCUIT (simplified defaults Required < 3 Defaults(Yes/ from section 7.6.71) y w 2 DC/AC MICROINVERTER(IQ7+-72-2-US)(23) 5 UTILITY GENERATION METER � o � Enphase IQ7+Max output 1.21 A @240V 6 PV SYSTEM AC DISCONNECT Rated AC Output Current: No). 4!-BOX(0760-41 AD)Soladeck AC/DC Rated Combiner 27.83A AC Nominal Operating Voltage:240V AC Under Frequency 56.5 Nz 0.16 1 s Box flashed on roof 7 RAPID SHUTDOWN SHUTDOWN SWITCH FOR SOLAR (91u) IS 6 AC COMBINER(sub-panel)2x 20A Breaker/branch. SYSTEM(reflective) Under 81 U;uency 56.5 Hz 30o N o 1 x 5A breaker for Envoy 8 WARNING!ELECTRICAL SHOCK HAZARD TERMINALS z n b 6 ENPHASE ENVOY(ENV-IQ-AM1-240 M)IQ Envoy ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED Over Frequency 61.2 Hz 300 (81 O) Y Gateway production RGM in pass thru enclosure. IN THE OPEN POSITION .60 7 MA SMART GEN METER(utility owned)Socket 9 WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES Over Frequency 62.0 Hz 0.16 =N c installed for Utility's SMART Generation meter UTILITY GRID AND PHOTOVOLTAIC SYSTEM (910) = L $AC DISCONNECT(DU222RB)60A 240VAC(adjacent 10 WARNING!INVERTER OUTPUT CONNECTION DO NOT Under voltage 50%of Nominal 1.1 r . to utility meter) RELOCATE THIS OVERCURRENT DEVICE (27) yz UnderVofta9 a 88%of Nominal 2 9 MAIN SERVICE PANEL 200A MAIN,200A BUS.35A 11 SOLAR PV (27) s o Inverter OCPD 12 WARNING!UTILITY METER ENERGIZED BY 2 a du 'a Over Voltage(59) 110%of Nominal 2 w w m 10 UTILITY METER(#95068216)120/240V, 1PH,3W SOURCES t=t: > g Over Voltage(59)120%of Nominal 0.16 L y o rn s OCPD Calculations: Q NEC 210.19(A)(1)(a)) a e Inverter Enphase IQ7+Max Output= 8$ 1.21 A x 23=27.83A x 1.25=34.7875A 6 To/From Q j Utility (.J F- 8 PVS Lu PV; PV„ s UnkWh I v 100kWh -J 12 r _ - I � INIR NT i t CIRCUIT _ L z v 9! PV 1 11I W. __ _� ' �•,5 li t_ 7 i - _ .. • m NVEmERS ..,c � i ■• i � v b p 1 '11 ISI ISI 11 -