Loading...
31A-142 (3) 36 FORBES AVE BP-2019-0824 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block: 3 1 A- 142 CITY OF NORTHAMPTON Lot: -001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0824 Project# JS-2019-001359 Est.Cost: $28221.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Groin VALLEY SOLAR LLC 077279 Lot Size(sq. ft.): 6926.04 Owner. BRADY CARYN Zoning-:URB(100)/ Applicant: VALLEY SOLAR LLC AT. 36 FORBES AVE Applicant Address: Phone: Insurance: PO BOX 60627 (413) 584-8844 WC FLORENCEMA01062 ISSUED ON:1/31/2019 0:00:00 TO PERFORM THE FOLLOWING WORK: 26 PANEL SOLAR ROOF ARRAY, 8.71 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupant Sianature: FeeType: Date Paid: Amount: Building 1/31/2019 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner cf Department use only City of Northampto JAN 1 St tus of Pe mit: Building Departme t ct 9t%t/Dr ewaPermit 212 Main Street Sewer/Septi Avai ability Room 100 DFPT of r:UILDini vaila ility a ,r Northampton, MA 01 rvo9T"AtiarTo $'&ts'of Struc ural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONCE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION �� 1.1 Property Address: This section to be completed by office � L 36 Forbes Ave, Northampton, MA 01060 Map Lot _Unit Zone Overlay District Elm St.District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: Matthew Czaplinski and Caryn Brady 36 Forbes Ave, Northampton, MA 01060 Name(Print) Current Mailing Address: 617-718-7080 Telephone Signature 2.2 Authorized Aaent: Valley Solar LLC PO Box 60627, Florence, MA 01062 Name(Print) ICurrent Mailing Address: 413-584-8844 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building (a)Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) 5. Fire Protection 6. Total=0 +2+3+4+5) $28,221 Check Number This Section For Official Use Only Building Permit Number: Date Issued: j Signature: (L2911 Building Commissioner/Inspector of Buildings Date I a.gov nfo(dWalleysolar.solar. EMAIL ADDRESS (REQUIRED; NiONTRACTOR) Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Size Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg. Square Footage % Open Space Footage % (Lot area minus bldg&paved parking) #of Parking Spaces Fill: (volume&Location A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES O IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO O DONT KNOW O YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation,or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO Q IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition Replacement windows Alteration(s) Roofing Or Doors ❑ Accessory Bldg. ❑ Demolition ❑ New Signs [p] Decks [Q Siding[o] Other[X Solar Brief Description of Proposed Work: Installation of a 26 Panel Solar roof array. System size 8.71 kW DC Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet sa.if New house and or addition to existing housing, complete the following: a. Use of building : One Family Two Family Other b. Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, Matthew Czaplinski and Caryn Brady as Owner of the subject property hereby authorize Valley Solar LLC to act on my behalf,in all matters relative to work authorized by this building permit application. 7nazet,.,e.ur 01/18/2019 Signature of Owner Date I Valley Solar LLC as Qmxw/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name it kid i Signature of Owner/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable ❑ Name of License Holder License Number Steven Silverman CS-077279 Address Expiration Date 268 Fomer Road. Southarngton, MA 01073 6/21/2020 Signatu lephone fX' 413-584-8844 9.Registered Home Improvement Contractor: Not Applicable ❑ Company Name Registration Number Valley Solar LLC 186338 Address Expiration Date PO Box 60627, Florence, MA 01062 Telephone 413-584-8844 p 117 � SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes.......V No...... City of Northampton Massachusetts z �A ' DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street •Municipal Building ' Northampton, MA 01060 Debris Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. The debris from construction work being performed at: 36 Forbes Ave (Please print house number and street name) Is to be disposed of at: Valley Recycling. (235 Easthampton Rd, MA 01060) (Please print name and location of facility) Or will be disposed of in a dumpster onsite rented or leased from: Valley Solar. (POB 60627, MA 01062) (Company Name and Address) 4�� _ I1 Signature of Permit pp er Date If, for any reason, the debris will not be disposed of as indicated, the Applicant or Owner shall notify the Building Department as to the location where the debris will be disposed. The Cotnnionwealth of'Massachusetts - - Department of Inclustrial Accidents 7 Congress Street, Suite 100 Boston, MA 02114-2017 wwminass.gov/dia Wrarkers'Compensation Insurance.affidavit:Builders/Contractors/Electricians/Plumbers. TO BE FILED WITH THE PERMITTING AUTHORITY. Applicant Information Please Print Legibly Name (Business/Organization/Individual):Valley Solar LLC Address:340 Riverside Dr., PO Box 60627 City/State/Zip:Florence, MA 01062 Phone#:413-584-8844 Are you an employer'. Check the appropriate box: Type of project(required): I.0 1 am it employer with 6 employees(full and/or part-time).* 7. ❑New construction 2.[:]I ant a sole proprietor or partnership and havc no employees working fa'ntc in b. Remodeling any capacity.(No workers'comp.insurance required.] y. ❑Demolition 3711 am it homeowner doing all work myself[No workers'comp.insurance required.]' l0 Q Building addition 4.❑1 am a homeowner and%will be hiring contractors to conduct all work on my property. I will ensure that all contractors either hive workers'compensation insurance or are sole l I.Q Electrical repairs or additions proprietors with no employees. 12.❑Plumbing repairs or additions 5 I am a general contactor and I have hired the sub-contractors listed nn the attached sheet. ` 13.❑Roof repairs These Sub-contractors have employees and have workers'comp.insurance.- 14.[]OtherSolar 6.❑We are a corporation and its otlicers have exercised their richt of cxentptiun pct)dCiL c. 152.§](4),and we have no employees.[No workers'comp.insurance required.] 'Any applicant that checks box R I trust also till our the section below showing nccir workers'compensation policy information. Homeowners who submit this affidavit Indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. aC'ontncto-s that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. It the sub-contractors have employees.they must provide their workers'comp.policy number. I arts an employer that is providing workers'compensation insurance for try employees. Below is the policy acrd job site information. Insurance Company Name:Berkley Insurance Policy#or Self-ins. Lic.#:MAARP301229 Expiration Date. 2/1/2019 Job Site Address. 36 Forbes Ave City/State/Zip:Northampton, MA 01060 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under_MGL c. 152, `25A is a criminal violation punishable by a fine up to SL500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator.A copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. 7 do hereby certify under41aq wins and penalties ol'perj the information provided above is true and corn'Cr. Signature: 4 Date: Phone#:413-584- 844 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: 152 S. Broad St. FUSION Lansdale, PA 19446 (215)361-8040 January 18, 2019 Valley Solar 340 Riverside Dr Northampton, MA O1062 RE: Czaplinski Residence 36 Forbes Ave, Northampton, MA 01060 Client Project#:36CZAP PFE Project#: 191 195 On behalf of Valley Solar, Penn Fusion Engineering LLC (PFE) performed a structural analysis of the roof at the above referenced location.The purpose of our analysis was to determine if the existing roof system is structurally sufficient to support the new photovoltaic moudles in addition to the code required design loads.Our analysis is based on the information provided by Valley Solar and is isolated only to the areas where the modules are intended to be placed. System Specifications: Total System Size: 8.71 kW/DC Panel Specs: (26) LG Solar- LG335N1 C-A5 Inverter Specs: (26)Enphase- IQ7+ Racking System: SnapNRack-Series 100 UL The modules are to be located on the following roof plane: Mounting Rafter Rafter Horizontal Collar Collar Tie Shingle Number of Ceiling Plane Size Spacing Span Ties Spacing Sheathing Type Shingle Layers Profile 1 2x6 24" 14ft. Oin. N/A 0" CDX 1/2" Shingles 1 Flat The roof design has been analyzed in accordance with the 2015 International Residential Code and Massachusettes Amendments 9th Edition with design loads as follows: Ground Snow(Pg): 40 psf Wind Speed (V): 117 mph Mounting Plane 1 The calculations for these structural members are attached. It has been determined by this office that the rafters, as specified above, exceed the allowable span for the total design loading.Attached are repair details that,when installed,will render the roof design structurally adequate to support the new PV modules in addition to the code required design loading. Attach the module rail brackets to the roof with 5/16" lag bolts at 48 on center maximum. Provide a minimum of 2" of penetration into the wood members. This office has determined that the installation of the PV System as specified above will meet the structural requirements of the 2015 International Residential Code with Massachusettes Amendments 9th Edition and ASCE7-10 when installed in accordance with the manufacture's instructions. If you have any questions regarding this analysis, please feel free to contact us. Of Best Regards, Penn Fusion Engineering LLC o UAE Andrew D. Leone, P.E. �/, 'I � Principal S��NAL EtY FUSION 152 S. Broad Lansdale, PA 1944646 (267)640-2758 Client Name: Valley Solar PFE Project Number: 191195 Client Project Number: 36CZAP Project: Czaplinski Residence Address: 36 Forbes Ave Northampton, MA 01060 Description: Mounting Plane 1 Calculations By: ADL Date:January 18, 2019 Roof Construction 2x6 Rafters at 24"on center A= 8.25 int Ix= 20.8 in Sx= 7.56 in3 Wood Species= Doug-Fir Larch#2 Fb= 900 psi Fv= 180 psi E= 1600000 psi Roof Slope= 45 ° Rafter Span= 13.98 ft Ceiling Attached to Rafters?: No Desian Criteria Ground Snow(P9): 40 psf Design Wind Speed: 117 mph Live Load: 20 psf Dead Load: 5.26 psf PV Modules. 4.24 psf Wind Calculations Directionality Factor(Kd): 0.85 Topographic Factor(K,t): 1 Velocity Pressure Exposure 0 7 Coefficient(KZ): Importance Factor(1): 1 Velocity Pressure (q,): 20.85 psf Tributary Square Footage on 10.83 ftz Component: Component Roof Pressures: 22.45 / -28.63 psf Snow Load Calculations Exposure Factor(Ce): 1 Thermal Factor(C): 1 Importance Factor(1): 1 Flat Roof Snow Loads (Pf): 35 psf Roof Slope Factor(CS): 0.625 Sloped Snow Loads (P): 21.9 psf Unbalanced Snow Load: 40 psf Member Calculations Bending Md: 2416.91 in*Ib fb: 3835.1 psi Load Duration Factor(Cd): 1.15 Stability Factor(CO: I Wet Service Factor(Cm): I Temperature Factor(CT): I Size Factor(CF): 1.3 Flat Use Factor(Cf.): I Incising Factor(C): I Repetitive Member Factor(C,): 1.15 Fb: 900 psi F'b! 1547.33 psi 3835.1>1547.33 No Good in Bending Shear Vd: 691.76 lb fV: 125.77 psi Load Duration Factor(Cd): 1.1S Wet Service Factor(Cm): 1 Temperature Factor(CT): I Size Factor(CO: 1.3 Flat Use Factor(Cfu): 1 Incising Factor(Cl): I Fv: 180 psi F'v): 207 psi 125.77<=207 OK in Shear Deflection Live Load Deflection (AL): 2.06 in L/81 No Good in Live Load Deflection Total Load Deflection (AT): 2.55 in L/66 Load o Good in Total LDeflection Uplift Calculation Tributary Square Footage on Component: 10.83 ftp Uplift Pressure: -28.63 psf Uplift per Lag: -310.15 lbs Lag Screw Diameter: 5/16 in Allowable Withdrawal per Inch: 490.99 lbs/in Minimal Screw Penetration: 0.63 in Install 5/16"diameter lag screws P 48 on center with minimum penetration of 2"into rafter. 152 S. Broad St. FUSION Lansdale, PA 19446 (267)640-2758 Client Name: Valley Solar PFE Project Number: 1 91 195 Client Project Number: 36CZAP Project: Czaplinski Residence Address: 36 Forbes Ave Northampton, MA 01060 Description: Mounting Plane 1 Calculations By: ADL Date:January 18, 2019 New Sistered Rafter Size: 2x10x8'Doug-Fir Larch#2 or better* Nailing Requirements: (2) l Od Nails @ 12"on center with (3) additional 1 Od Nails at each end I Od = .12"shank diameter x 3"long minimum Note:Apply repair to each rafter under PV system *Suitable Alternate Species: -Spruce-Pine-Fir#2 or#1 -Southern-Yel low-Pi ne#2 or#1 Utility Client: a U Caryn Brady N a MASOM 36 Forbes Ave, m : Northampton,MA 01060 AIN AC o J FORBES AVE Sc s >. m U Q 4 £ 0.c) O E Y L d C O 2Z a W IV Q � � {� PLAN LEGEND >Q m a i (26)LG335N1C-A5 PV PANELS Z e ss SNAPNRACK SERIES 100 RACKING g P£ (26)ENPHASEIQ7PLUS MICR04NVERTERS s HOUSE INTERIOR E MAIN MAIN PANEL(E) z? m €a _3 �o SC SOLAR PV COMBINER BOX(N) m # HOUSE EXTERIOR a UTILITY METER(E) £m AC DISCONNECT(N) 'y �P MASG M MA SMART GEN METER(N) lel.,pen is McPropnefery wM ProMrcr of VeNey Hama lmpronTBnl 1-(VHI).tt;.,dw'irsreC br Me limileJ erM exdnrw Pn orsrppo/tlng Me carxrecl Oid o/VHI,eM arslWrw/egMS Maj MB efem�N,ol Mis pen.WeN not es rep�raraeea orprea.nreein eny brm lar Me Purpose of eneElin9 or SUPWMn9 Me woMW cximetlng project contreclors wow pre pemYssion of YM co-*-ebm peM/b.vN,. f l0 I VT A CT to A w.1 A W Q G CJ rt w D0 _ AOA , C C1 d r� Y fl .lar LLC 1340 Riverside Dave SITE NAME M.Czaplinski and C.Brady 9 ESEE VIEW SHEET NUMBER Valley Soalley PO Box 60627 i Northampton PLOT LINES SITE ADDRESS 36 Forbes Ave ppTE,a,9 s lar MAO 10621413584 W Northampton,MA01060 .VatleySolar.Solar SYSTEM SIZE 8.71 kWDC 7.54 kWAC DRAW&LRRLW WWW AS 2 r� PVt PV> PV: PV, 1 s 7 w i�l ------ 6 T From 9 7 •• � R I Utility s I II I07+ it „ • q I II NVERTERS 1 SII I l T !'I�I 4 f ) g CMZ�H �—� I ✓; 1,.....' .. f..• 2 1 Y iw mco T� �.71 s°. a � 4 w � II i III _ y _.Ie _y - la � --.If• '' I I g. I chi c �a� W—fl- PVI PV2 PV PV1, i a li I07+ 1 1 ( �; �'I I I _M to j m (j was IH INDH ! _ i 'y+ .. _ I ccOex[x ea ,iwwmx a II Mx Ro 1 � i �. a LL c .__ fay ,lu• -- I I 2' „-— 5ASE—NT .� m E 3 • • U L� I I W w N--------------------- -- -- �� r PV1 PV, —1 I I I II � ~T = I nl l ( OCPD Calculations: w ••' 05 N N I I IQ7 � - - - �=I I 1.21A x 26=31.46A x 1.25=39.325A CIRCUIT�v MICRO � l,, __ 1 \' y ;T ' L ! ,�--•-.: � l ��; 1 33 I( IRCUR I I =- Q s I w Ian � Iu I ui I I I ——_— Inverter Trip Settinas: I —————— ——————————————————— I Inverter TRIP settings are set in the inverter per the ISO NE U L— — RooF ARRAY— SRD and ESB 756 section 7.6.11. — DEVICE DEFAULT DEFAULT Pickups and F- c PICKUP CLEARING TIME Clearing Times LI Labeling ScheduleEauipment Schedule SETTING (seconds) Adhere to t j 1:1 0 (simplified Required I. 1. 2 SOLAR PV MODULE(LG335N1C-A5 26x LG335W AC WARNING!PHOTOVOLTAIC POWER SOURCE 1 PV ARRAY(Series 100)Snap N Rack Roof Mount System defaults from Defaults(Yes/ m .SOLAR PV AC COMBINER BOX section 7.s.t1) No): 2 > _ o ` €� 3.PV SYSTEM AC CIRCUIT panels.Max output 41.OV/10.49A Under Frequency 56.5 Hz 0.16 s?� 4.UTILITY GENERATION METER 3.DC/AC MICROINVERTER(IQ7-72-2-US)26x Enphase (81U) $@'i 5.PV SYSTEM AC DISCONNECT Rated AC Output Current: IQ7.Max output 240VA/1.OA Under Frequency 58.5 Hz 300 g a 31.46AAC Nominal Operating Voltage:240V AC 4 J-BOX( F Over Freq a oiadeck)Soladeck Pass-through enclosure ( req �' 6.RAPID SHUTDOWN SWITCH FOR SOLAR PV SYSTEM 5.AC COMBINER(X-IQ-AM1-240-2 M)Enphase IQ Envoy uency 61.2 Hz 300 — S g 7.WARNING!ELECTRICAL SHOCK HAZARD TERMINALS Gateway production RGM,Max 80A.3x AC 15A Breaker/ (sto) g ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED branch.5A breaker to feed Envoy.Production CTs. Over Frequency 62.0 Hz 0.16 N° t IN THE OPEN POSITION f,MA SMART GENERATION METER(utility owned)Socket (810) 1; 8.WARNING BUSBAR IS ENERGIZED FROM 2 SOURCES installed for Utilitys SMART Generation meter Under Voltage 50%of Nominal 1.1 15 UTILITY GRID AND PHOTOVOLTAIC SYSTEM 7 AC DISCONNECT(DG222URB)60A 240VAC(adjacent to (27) > Under Voltage 88%of Nominal 2 I 9.WARNING!INVERTER OUTPUT CONNECTION DO NOT utility meter) 9 C� (27) RELOCATE THIS OVERCURRENT DEVICE 5.SERVICE PANEL 200A MAIN,200A BUS,40A Inverter y Over Voltage(59) 110%of Nominal 2 �+ 10.SOLAR PV OCPD r• aV 11.WARNING!UTILITY METER ENERGIZED BY 2 SOURCES 2..UTILITY METER(#80498502)120/24OV, 1 PH,3W Over Voltage(59)120%of Nominal 0.16 E 2 THIS ELECTRICAL DRAWING IS A PROPOSED DESIGN.THE ELECTRICIAN IS AT LIBERTY TOADJUST DURING THE BUILD AND AMENDMENTS WILL BE REFLECTED IN THE AS-BUILT DIAGRAM. WLG Innovation for Lif<._ (lack, a Better Life Lo"' r LG',4 n ev rTli;iluif',I_u Net)k1' L,aCialpt5 Lz--Iro ter h 1rhn3p: s e0o technology wpliaces 3 t ush z Jnr }h 1 th vires 60cell c nh3r pe ger rttpilt Enc+rll1�� 11ty uC�P( C�R� '� i1ECE : d o sr 1te I G eff ort lo in( e .u t I IIor ti t 111 f� eyory efficlez r y it features enh mced U a.tanty,d rahihty, I itertti< OerFr,,„iarxe undo real onvirrinmoot,iin 9 ,c!hctii rl sian suitatae fm f oof5 Enhanced Performance Warranty •� High Power Output L=_, ��,_v ?'h_:a„er sn.:e,u�E �.r�nancl �r1�_.•tu_ — - ;r..Gi _..,rf ,1r_. 1tlr,s,tr _ ._, �;” Thr jr1 ual at-aradation ha fade n From-0 E,c dr E.r-n Jter. _ year; h r mo r ut. ion rhs>p o/1 u N IT odoiI- Aesthetic Roof ; Outstanding Durability .. L(=,NiP „v`,��as been lc� tlnr,ti rnrith aeslh v ;�,��r ,rx1, �Ivit? ,�Nair,r-neorrz�1 rn e tr errrr 11+x:1 r , IIj tl. pirira, allblark<ztadislu��ce. Gti(dl�AI` . 1-1li [Jr)C,,,.--lily ;r,lp rjj tn. ,alue of �E 1)1 n desIgr c a' o'I 1,, Better Performance on a Sunny Day VL Double-Sided Cell Structure l-G Nt l,,w.,; I1Ovj nerfo T1, lJP;Ir r o.l 3i1,^n�.;J,' 'nrn L to r5,n il,ro,.. 1+elrtpelar 1t>oethr'Fncy. �� ?I "i,jus lr.< <`,e f u t '1tr lint an�� f About LG Electromc.:> LG eON 2 Mechanical Properties Electrical Properties(STC*) Cells x 10 Module 1-633SNIC-AS Cel!Vendor `- Maximum Power(Pmax) Cell Type -- l_io �) ryto J; " MPP Voltage(Vmpp)__- _ u Coil Dimensions 1 x MPP Current(Ins ) a of Bushar- 12(m..i Open Circuit Voltage Dimensions(L x x H) 1 eRa x' ,u. Short Circuit Current(Iso} 56 38 r Vex' Module Efficiency Front Load OAU d OperatM,Temperature - - - Rear Load - 5400Pa Maximum System Voltage ilJeight o k'; Maximum Series Fuse Rating Conner or Type P4C. PowerToteran€e Junction Box PS n,rh,E3yaas_ Cables - 0,00 n x ea Glass High T rni: me Fra R. _ �___ __._._�_ ------- ---------- Electrical Properties(NOCT*) Certifications and Warranty __—"-- _ —•-_-_.-- __.�___ _ __�_______.___.___ Module LG335N'I C-AS Certifitatnn, Iii. , _ `.-.. -. -._. Maximum Power(Pmax) MPP Voltage(Vmpp} 5. MPP Current(Impp) 3 Open!;circuit Voltage(Voc) J;j i Short Circuit Current(Iso) c + Module Fire Performance(USA) yl)`_ Fire Rating(CANADA) Product Warranty Output Warranty of Pmax n,fit.- _ - _�___."���_ Dimensions(mm/in) Temperature Characteristics NOCT ....,. PIPPI) - - - n., , Iso u _ Characteristic Curves I000 -- 600W 40OW 200W I MR :: : L2 LG l i Innovation for a Better Life The high-powered Srn8[tgM rzz,�� andEnp��us` �� 7� ��x��o= �� d�m��l�S|mp|�t� ins�U�i� pm�� whi� achieving the highest system efficiency. �� �� ��� v ' ~ ��° Part ofthe EnphaSe |OSystem,the |Q7and |O7+ K4iCn}inVerterSintegrate with the EDph8oe |DEDVoy=. Enph@Se IQ8attS,y=, and theEnph@se Enlighten" monitoring and analysis software. IQ Series MiC[0|nve[tersextend the reliability standards set forth hyprevious generations and undergo over 8million hours Ofpower-on testing, 8nGb|ingEDph8Se tOprovide 8nindUStry-leading warranty ofUptO25years. Easy toInstall ' Lightweight and simple ' Fac/crinstallation wfhimproved,lighter two-vote cabling ' Built-in,apidshv/downcumn|mm(NEC z0w:zO|7) Productive and Reliable ' Optimized for high powered a0-reUand 72-cex°,nndu|es ' More than amUUnnxvurvnrtesting ' Class odouble-insulated eno|nnurr ' UL listed Smart Grid Ready ' Complies with advanced grid ovvoo,tvoltage and frequency xde-thmuuhmvu/,;ments ' nemmdvupdates tnrespond lo changing o'm,evo.,emn^tn ' CnnSgvrabbhxvarymgg,dpm�|os ' Meets CARule 21 (U! I 741'SA) ~meif)r~m.p".xte« "oumwnj)o^x2 oy/wmux-. =��� !�D ENPHASE Enphase IQ 7 and IQ 7+ Micrcinverters INPUT DATA(DC) IQ7-60-2-US/IQ7-60-B-US IQ7PLUS-72-2-US/IQ7P1_US-72-B-US Commonly used inoduie pairings' 235'Vi-'350 W 235 VV-440 Vv+ Module compatibility 60-cell PV rnodutes only 60-cell and 7,'--cell PV modl.11es Maximum input DC voltage 43 V 60 V Peak power tracking voltage 27 V-37 V 2%V-45 V Operating range 16 V-48 Vi6 V-60 V Min;Max start voltage 22 V. •18 V 22 V, 60 V Max DC short circuit current(module Isc) 15 A 15 A Overvoltarge class DC port it If DC port backfeed current 0 A. 0 A PV array configuration 1 x 1 ungrounded array;No additional DC side protection recruited, AC side protection requires max 20A per blanch circuit OUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter Peak Output power 250 VA 205 VA Maximum e ontir,uolus Output power 2.40 VA 290 VA Nominal f?.-L)voltage/range' 240 V/ 208 V 1 240 V/ Z08 V i 211-264 V 183-229.' 211-264 V 183-229 V Maximum continuous output current i.0 A(24f3 V) 1 15 A(20&V) 1 21 A f240'✓) l 39 A(208 V) Nominal frequency 60 Hz 60 H, Extended frequency range 47-68 Hz 47-68 Hz AC short circuit fault current over 3 cycles 5.3 Arms 5.8 Awns Maximum units per 20 A(L-L)branch circuit' -,6(240 VACj 13(208 VAC 13(240 VAC) 11 (208`.'A(',) Over voltage class AC port iff ill AC port backfeed current 0 A 0 A Power facto!setting 1.0 1.0 Power factor(adjustable) 0.7leading _0:'lagging 0,7leading_.G., lagging EFFICIENCY 0240 V @208 V @240 V @208 V Peak CEC efficiency 47 6`<, 97.6 97 5 97 3 CtC weighted efficiency ()7,0 900 MECHANICAL DATA Ambient temperature range -40°C to+65°C Relative humidity range 4`,to 107'%(condensing) Connector t pe(lQ7 b0 <.J�&iQ,PLUS;'Z L USi b�H(cr Alnphenof 114 UTX vwrth additional Q uGC 5 adapter; Connector type(IQ7-60-13-US&lQ71-ILUS-72-13-US) Friends PV2(MC4 intermateable). Adaptors for modules with MC4 or ill X connectors: PV2 to MC4 order ECA-S-20-S2? PV2 to UTX.order ECA-'120-S25 Dimensions(WxHxll) 212 ruin x 175 min x 30,2 mm(~,v`ithout bracket) Weight 1.08 kg(2.38 lbs) Cooling Natural convection-No fans Approved for wet locations yes Pollution degree PD3 Enclosure Class If double-insulated,corrosion resistant polymeric enclosure Environmental category!UV exposure rating NEMA Type 6/outdoor FEATURES Cc,mmunir,ation Power Line Communication(I'll-C) Monitoring Enlighten Manager and MyEnlighten monitoring options, Both options require installation of an Enphase IG Envoy. Disconnecting means The AC and DC connectors have been exiaivated and approved by UL for use as the ioad-bl s2k disconnect required by NEC 690. Compliance CA Rule 21 (UL 1741-)A) UL 62109-1,UL1/4'1/ILL t 154/,;'"C Fart 15 Class E, ICES 0003 Class Ll, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Papfd Shut Down Equipment and conforms with NEC-2014 aad N EC-2017 section 690-12 and C22,11-20111 Rule 64-218 Rapid Sh"it down of P's Systerfl s.fol" and DC conductors,when installed according manufacturer's instructions No e"ifo,l_�d L ..,,:alio ,er.the compatibility ealr,ril Itor at'h!"11" �.Nrin nal aoltn, ar.gU :.an.he extended 6ei:.nd rwm jai if regwre d ilv th Irl{ I 1m t5 may vary Rater to lorai r2G"11 n eh(s To urf.ite the uurtke, 'mice., I.ei rei,--,,petLI anc w torte arca_ To learn more about Enphase offerings,visit enphase.com EN P H A S E v� il, SNAPNRACK SERIES 100 RACKING SYSTEM TYPICAL ROOF LAYOUT REVISION: NOTES: - --- -- - -STANDARD LAG BOLT SPEC ASSUMES - — 5/16" LAG BOLTS WITH 2.5" — EMBEDMENT IN ROOF STRUCTURAL MEMBERS/RAFTERS -TORQUE ALL A" HARDWARE TO THE FOLLOWING: r ROOF RAFTERS OR -SILVER S.S. 10-16 FT-LBS % STRUCTURAL MEMBERS - BLACK S.S. 7-9 FT-LBS RAIL CAN MOUNT TO EITHER SIDE OF i POST(UPSLOPE vs. DOWNSLOPE) - FOR UNEVEN ROOF SURFACES, USE r SNAPNRACK MODULE UP TO TWO LEVELING SPACERS PER L - _ MID CLAMPS MODULE OVERHANG FOOT OR STANDOFF. SEE DRAWING \� (NOT TO EXCEED 30% "STANDARD RAIL LEVELING" FOR p OR MANUFACTURER'S DETAILS AND LIMITATIONS i, �� RECOMMENDATIONS) MODULE OVERHANG-� i STANDOFFS ARE BOLTED INTO ROOF RAFTERS OR STRUCTURAL MEMBER "RAIL SPAN" DISTANCE BETWEEN ROOF ATTACHMENTS "RAIL END OVERHANG' (NOT TO EKCEED�� 340/o OF ACCEPTABLE RAIL SPAN) DESIGNER: G McPheeters_ — DATES 12D0113 PART $1OONUMBER: D05 DESCRIPTION: SERIES 1OO TYPICAL LAY©UT j REV MAINSTREAM ENERGY CORP A '( IIYAIOOI�QM�IQO\FIJI —�Ittl/11� p ., APPROVED BY Ryan - -- - — -- ------