Loading...
573 Certificate of Compliance 2013 Commonwealth of Massachusetts f '--r- f City/Town of Northampton _;Ff_ Certificate of Compliance Form 3 DEP has provided this form for use by local Boards of Health. Other forms may be used, but the information must be substantially the same as that provided here. Before using this form, check with the local Board of Health to determine the form they use. This is to Certify that the following work on an On-Site Sewage Disposal System Important:When FILE COPY po act ® Construction of a new system on the computer. El Repair or replacement of an existing system use only the tab ❑ Repair or replacement of an existing system component key to move your cursor-do not use the return Has been done in accordance with Title 5 and the Disposal System Construction Permit(DSCP): key. 2016 DSCP Number DSCP 5/15/13 DSCP DSCP Date Scott Keiter Facility Owner O 573 Sylvester Road (Lot 4) Street Address or Lot# Northampton City/Town State Zip Code Designer Information: Greg Newman Newman Environmental Engineering Name Name of Company —Cti 74/ la Signature Date Installer Information: Todd Alexander Westhampton, MA Name Name of Company -6,4i 741/4 Signature Date Use of this system is conditioned on compliance with the provisions set forth below: tuL The issuance of this certificate shall not be construed as a guarantee that the system will function as designed. Northam•ton Health De•artment Approving Authority I� 11/3/2017 Signature - Date t5fonn3.dac•06/03 Certificate of Compliance•Page 1 of 1 NEWMAN ENVIRONMENTAL ENGINEERING October 29, 2017 Scott Keiter FILE COP Y do Keiter Builders Inc. 35 Main Street Florence,MA 01062 Engineer's Certificate of Compliance THIS IS TO CERTIFY, That the On-Site Sewage disposal System installed®or repaired/ replaced❑ on Mar-2016 —Mar-2017,final inspection Oct-2017 by Todd Alexander,Westhampton,MA for Scott Keiter at Lot on Sylvester Road,Northampton,MA has been constructed in accordance with the provisions of TITLE 5 of the State Environmental Code as described in the plan entitled: SEWAGE DISPOSAL SYSTEM AT LOT ON SYLVESTER ROAD,NORTHAMPTON,MA Dated 5/15/13 Prepared by:Newman Environmental Engineering Drawing No.Z1305-1 With the following exceptions noted: 1. Minor changes to the location of the new septic system facilities as noted on the enclosed "AS- BUILT"site plan. 2. Final grading(loam & seeding) around house site not complete at time of final inspection. 3. D-box/leach field inspected October 15,2017 did not find sign of high flow to leach field. Vegetative cover over leach field requires maintenance to establish consistent grass cover to prevent growth of deep rooted plants (that will plug leach field). Recommend re-seeding and maintaining leach field area by monthly mowing(as a minimum)during growing season. 4. System not in use as of October 15,2017(house still under construction). Owner shall prevent paints,drywall dust, plaster and other construction materials from entering the septic system. 5. In spring,Owner shall inspect sewer near Access Box(east of D-box)to ensure that installed trench barriers are sufficient to prevent spring groundwater from following trench to leach field. Use of this system is conditioned on compliance with the following provisions: 1. The area over the leaching facilities shall be maintained (by monthly mowing during growing season)to prevent cover erosion and/or root intrusions from trees and shrubs; see above comments. 2. Final grades shall be constructed and maintained as shown on as-built plan,attached; including drainage swales. 3. Owner shall conduct spring inspection of sewer route down hillside to ensure that runoff is not running to leachfield; see above comments. DATE: iU/-2 eyh a'O j / ENGINEER: aV, y Newman, o.34017, Sanitary CC: Board of Health Contractor