Loading...
37-041 FortierGirderCalcCS Structure™ 2.6.24[Build 1]kmBeamEngine 4.11.19.1Materials Database 1507 Jayne & rodger - Level 6 9-23-14 4:23pm 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Member Data Description: CalcG1 Member Type: Girder Application: Floor Comments: Fortier Cantilever Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 17.6 PLF Filename: C:\Users\Mik Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End CategoryReplacement Uniform (PLF) Top 0' 0.00" 1' 1.50" 24 0 Snow Replacement Uniform (PLF) Top 0' 0.00" 1' 1.50" 50 137 Live Replacement Uniform (PLF) Top 0' 0.00" 15' 0.00" 0 91 LiveReplacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 9 2 Live Replacement Uniform (PLF) Top 0' 0.00" 18' 0.00" 27 7 Live Replacement Uniform (PLF) Top 1' 1.50" 2' 3.00" 52 0 SnowReplacement Uniform (PLF) Top 1' 1.50" 2' 3.00" 50 143 Live Replacement Uniform (PLF) Top 2' 3.00" 3' 4.50" 70 0 Snow Replacement Uniform (PLF) Top 2' 3.00" 3' 4.50" 50 148 Live Replacement Uniform (PLF) Top 3' 4.50" 4' 6.00" 89 0 Snow Replacement Uniform (PLF) Top 3' 4.50" 4' 6.00" 50 153 LiveReplacement Uniform (PLF) Top 4' 6.00" 5' 7.50" 108 0 Snow Replacement Uniform (PLF) Top 4' 6.00" 5' 7.50" 50 157 Live Replacement Uniform (PLF) Top 5' 7.50" 6' 9.00" 126 0 SnowReplacement Uniform (PLF) Top 5' 7.50" 6' 9.00" 50 162 Live Replacement Uniform (PLF) Top 6' 9.00" 7' 10.50" 145 0 Snow Replacement Uniform (PLF) Top 6' 9.00" 7' 10.50" 50 166 LiveReplacement Uniform (PLF) Top 7' 10.50" 9' 0.00" 163 0 Snow Replacement Uniform (PLF) Top 7' 10.50" 9' 0.00" 50 171 Live Replacement Uniform (PLF) Top 9' 0.00" 10' 1.50" 182 0 Snow Replacement Uniform (PLF) Top 9' 0.00" 10' 1.50" 50 176 Live Replacement Uniform (PLF) Top 10' 1.50" 11' 3.00" 209 0 Snow Replacement Uniform (PLF) Top 10' 1.50" 11' 3.00" 50 182 Live Replacement Uniform (PLF) Top 11' 3.00" 15' 0.00" 50 191 Live Replacement Uniform (PLF) Top 11' 3.00" 15' 0.00" 242 0 SnowReplacement Uniform (PLF) Top 15' 0.00" 18' 0.00" 242 0 Snow Replacement Uniform (PLF) Top 15' 0.00" 18' 0.00" 50 282 Live Point (LBS) Top 0' 4.63" 0 6 LivePoint (LBS) Top 0' 4.63" 12 3 Snow Point (LBS) Top 0' 4.63" 24 0 Snow Point (LBS) Top 0' 4.63" 44 235 LivePoint (LBS) Top 0' 4.63" 3 374 Live Point (LBS) Top 0' 4.63" 1003 0 Snow Point (LBS) Top 12' 3.00" -236 0 Snow Point (LBS) Top 12' 3.00" -1 -17 Live 1 2 15 0 0 3 0 0 18 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 4429# -- 2 15' 0.000" Wall N/A N/A 1.500" 5518# -16# Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 674# 1849# 2537# 2 914# 2203# 3180# Design spans 14' 7.375" 3' 0.000" (right cant) CS Structure™ 2.6.24[Build 1]kmBeamEngine 4.11.19.1Materials Database 1507 Jayne & rodger - Level 6 9-23-14 4:23pm 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS NOTE: Pass-thru framing is required at point loads over bearings. Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 11734.# 38167.# 30% 7.86' Odd Spans D+0.75(L+S) Negative Moment 2495.# 38167.# 6% 15' Total Load D+0.75(L+S) Shear 3306.# 13622.# 24% 14.27' Total Load D+0.75(L+S) TL Deflection 0.3043" 0.7307" L/576 7.69' Odd Spans D+0.75(L+S) LL Deflection 0.1258" 0.4872" L/999+ 7.86' Odd Spans 0.75(L+S) TL Defl., Rt. -0.1905" 0.3000" 2L/377 18' Odd Spans D+0.75(L+S)LL Defl., Rt. -0.0855" 0.2000" 2L/842 18' Odd Spans 0.75(L+S) Control: TL Defl., Rt. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 % Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table