Loading...
24C-159 22 Beam 1 - 4p1178CS Beam 4.11.25.1 kmBeamEngine 4.11.25.1 Materials Database 1512 VHI / Hyman 22 Arlington St Northampton, MA 12-22-14 11:11am 1 of 1 All product names are trademarks of their respective owners Copyright (C) 2013 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED. **Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. John P. O'Leary Seven D Wholesale Rocky Hill, CT Member Data Description: Beam 1 Member Type: Beam Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 15 PLF Deck Connection: Nailed Member Weight: 20.8 PLF Filename: Beam2 Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PSF) Top 0' 0.00" 3' 6.00" 3' 0.00" 20 10 Live Additional Uniform (PSF) Top 0' 0.00" 3' 6.00" 3' 0.00" 45 20 Snow Additional Uniform (PLF) Top 0' 0.00" 3' 6.00" 0 80 Live Additional Uniform (PSF) Top 0' 0.00" 3' 6.00" 7' 0.00" 20 10 Live Additional Uniform (PSF) Top 0' 0.00" 3' 6.00" 7' 0.00" 40 20 Snow Additional Uniform (PSF) Top 3' 6.00" 16' 2.00" 8' 9.00" 40 15 Live Point (LBS) Top 3' 6.00" 438 110 Live concentrated load from perpendicular floor beam 1 2 16 2 0 16 2 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall Steel N/A 1.500" 5371# -- 2 16' 2.000" Wall Steel N/A 1.500" 4681# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 2918# 1320# 2192# 2 3203# 162# 1478# Design spans 16' 3.750" Product: 2.0 RigidLam LVL 1-3/4 x 11-7/8 4 ply PASSES DESIGN CHECKS Connect members with 2 rows of 1/2" diameter bolts at 24.0" oc Minimum 1.50" bearing required at bearing # 1 Minimum 1.50" bearing required at bearing # 2 Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 19647.# 44258.# 44% 8.08' Total Load D+L Shear 4516.# 16071.# 28% -0.06' Total Load D+L TL Deflection 0.4852" 0.8156" L/403 8.08' Total Load D+L LL Deflection 0.3223" 0.5437" L/607 8.08' Total Load L Control: TL Deflection DOLs: Live=100% Snow=115% Roof=125% Wind=160% Design assumes a repetitive member use increase in bending stress: 4 %