Loading...
Hyman A-5BABA123CCDrawn ByDate Issue 123mlCONSTRUCTASSOCIATES, INC.36 SERVICE CENTERNORTHAMPTON, MA 01060tel: 584-1224 fax: 584-7504A-51'-2"1291298'-0" FINISH6'-8" FINISHTRUSS DETAILSBY MANUFACTURER6'-8" FINISHHELICAL FOOTING PIER: LENGTHAND SIZE TO BE ENGINEERED BYPROVIDER/INSTALLER6 x 6 PT POSTPOST CONNECTOR PROVIDEDBY PIER INSTALLERCARPET ON 3/4" T & G PLYWOOD UNDERLAYMENTON 2 X 10 @ 16" CENTERSFLOOR JOISTS1'-0"1/2" GWBSIDING TO MATCH EXISTING HOUSE ON HOUSE- WRAP, ON 1/2" PLY-WOOD SHEATHINGON 2 X 6 WOOD STUDS WITH VAPOR BARRIERAND 1/2" GWBASPHALT SHINGLES TO MATCH EXISTING HOUSE ON 60# FELT AND 5/8" PLYWOOD SHEATHINGON TRUSS ROOF SYSTEM21'-5"10'-8 1/2"10'-8 1/2"SOLID BRIDGING(3) 2 X 10BEAMSOLID BRIDGING(2) 2 X 8 HEADER1 X 8 WATERTABLEMETAL STRAP TIEDOWNSPRAY FOAM INSULATION:R-30 MINIMUMINSULATION: R-21 MINIMUM,TYPE TO BE DETERMINEDINSULATION: R-50 MINIMUM,TYPE TO BE DETERMINED8'-0 3/4" WALL HEIGHT1CROSS SECTION1/2" = 1'-0"(3) 2 X 10BEAM(3) 2 X 10BEAMUNINSULATED SHEAR WALLINFILL AT ALL PERIMETER POSTS: 2 X 4 WOOD STUDS WITH HARDIPANEL SHEATHING AND PVC BATTENS. (NOT SHOWN)SIMPSON POST CONNECTOR,TYPICALSECTION1/2" = 1'-0"RENOVATIONS FOR:ART AND SHERRYHYMAN RESIDENCE 22 ARLINGTON STREETNORTHAMPTON, MA 010607-6-18FOR REVIEW7-18-18FOR REVIEW