ROOF PLAN 1/4" = 1'-0" 1 WOOD DECK BELOW ROOF FRAMING PLAN 1/4" = 1'-0" 2 WOOD DECK BELOW WOOD DECK BELOW WOOD TRUSSES, 24" ON CENTER WOOD TRUSSES, 24" ON CENTER 20'-11" 1'-0"6 1/2"
6 1/2" 6 1/2" ROOF EXTENDS ONTO EXISTING ROOF STICK FRAME ONTO EXISTING ROOF: 2 X 6, 16" O.C. ASPHALT SHINGLES TO MATCH EXISTING HOUSE ASPHALT SHINGLES TO MATCH EXISTING HOUSE RIDGE
VENT RIDGE VENT ALUMINUM GUTTER AND DOWNSPOUT 1'-0" 1'-0" 1'-0" 1'-0" 1'-0" ALUMINUM GUTTER AND DOWNSPOUT ALUMINUM GUTTER AND DOWNSPOUT ALUMINUM GUTTER AND DOWNSPOUT HEADER: (2) 2 X
8 HEADER: (2) 2 X 8 HEADER: (2) 2 X 8 HEADER: (2) 2 X 8 HEADER: (2) 2 X 8 1'-0" FIELD-ADDED OVERHANG 'LADDER' HEADER: (2) 2 X 8 2 X 6 BEARING WALL BELOW 2 X 6 BEARING WALL BELOW 2 X
6 BEARING WALL BELOW 1 A-5 1 A-5 SECOND FLOOR WINDOW MAY REQUIRE NEW, SHORTER UNIT: TO BE DETERMINED AFTER NEW ROOF IS IN PLACE 11'-8"6 1/2"1'-0" 6-26-18FOR REVIEW ml CONSTRUCT ASSOCIATES,
INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 ROOF PLANS A-4 1/4" = 1'-0" RENOVATIONS FOR: ART AND SHERRY HYMAN RESIDENCE 22 ARLINGTON STREET NORTHAMPTON,
MA 01060 B A B A 123 CC Drawn By DateIssue 123 7-18-18FOR REVIEW 8-7-18FOR REVIEW
Hyman A-5.pdf Hyman.vwx
B A B A 123 CC Drawn By DateIssue 123 ml CONSTRUCT ASSOCIATES, INC. 36 SERVICE CENTER NORTHAMPTON, MA 01060 tel: 584-1224 fax: 584-7504 A-5 1'-2" 12 9 12 9 8'-0" FINISH 6'-8" FINISH
TRUSS DETAILS BY MANUFACTURER 6'-8" FINISH HELICAL FOOTING PIER: LENGTH AND SIZE TO BE ENGINEERED BY PROVIDER/INSTALLER 6 x 6 PT POST POST CONNECTOR PROVIDED BY PIER INSTALLER CARPET
ON 3/4" T & G PLYWOOD UNDERLAYMENT ON 2 X 10 @ 16" CENTERS FLOOR JOISTS 1'-0" 1/2" GWB SIDING TO MATCH EXISTING HOUSE ON HOUSE- WRAP, ON 1/2" PLY-WOOD SHEATHING ON 2 X 6 WOOD STUDS
WITH VAPOR BARRIER AND 1/2" GWB ASPHALT SHINGLES TO MATCH EXISTING HOUSE ON 60# FELT AND 5/8" PLYWOOD SHEATHING ON TRUSS ROOF SYSTEM 21'-5" 10'-8 1/2"10'-8 1/2" SOLID BRIDGING (3) 2
X 10 BEAM SOLID BRIDGING (2) 2 X 8 HEADER 1 X 8 WATERTABLE METAL STRAP TIEDOWN SPRAY FOAM INSULATION: R-30 MINIMUM INSULATION: R-21 MINIMUM, TYPE TO BE DETERMINED INSULATION: R-50 MINIMUM,
TYPE TO BE DETERMINED 8'-0 3/4" WALL HEIGHT 1CROSS SECTION 1/2" = 1'-0" (3) 2 X 10 BEAM (3) 2 X 10 BEAM UNINSULATED SHEAR WALL INFILL AT ALL PERIMETER POSTS: 2 X 4 WOOD STUDS WITH
HARDIPANEL SHEATHING AND PVC BATTENS. (NOT SHOWN) SIMPSON POST CONNECTOR, TYPICAL SECTION 1/2" = 1'-0" RENOVATIONS FOR: ART AND SHERRY HYMAN RESIDENCE 22 ARLINGTON STREET NORTHAMPTON,
MA 01060 7-6-18FOR REVIEW 7-18-18FOR REVIEW