31A-088 2nd floor Girde CalcsCS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
1 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG2 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.1 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 3' 7.50" 45 22 Live
1 2
3 7 8
3 7 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Girder N/A N/A N/A 114# --
2 3' 7.500" Wall N/A N/A 1.500" 114# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 69# 44#
2 69# 44#
Design spans
3' 1.375"
Product: Hem-Fir (N) #2 2 x 10 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 88.# 3922.# 2% 1.85' Total Load D+L
Shear 57.# 2682.# 2% 2.78' Total Load D+L
LL Deflection 0.0010" 0.1038" L/999+ 1.85' Total Load L
TL Deflection 0.0010" 0.1557" L/999+ 1.85' Total Load D+L
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
This member has been designed in accordance with NDS 2005
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
2 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG3 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 13.7 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 10' 8.00" 49 16 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 8.00" 157 52 Live
Replacement Uniform (PLF) Top 10' 8.00" 12' 9.75" 157 52 Live
1 2
12 9 12
12 9 12
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 1757# --
2 12' 9.750" Wall N/A N/A 1.500" 1651# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 1255# 502#
2 1175# 475#
Design spans
12' 2.500"
Product: 1-3/4x9-1/4 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 5333.# 20704.# 25% 6.49' Total Load D+L
Shear 1534.# 9227.# 16% 0.4' Total Load D+L
TL Deflection 0.2062" 0.6104" L/710 6.49' Total Load D+L
LL Deflection 0.1472" 0.4069" L/995 6.49' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
3 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG4 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.0 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 10' 5.25" 143 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 5.25" 320 80 Live
Replacement Uniform (PLF) Top 10' 5.25" 12' 3.00" 143 7 Live
Replacement Uniform (PLF) Top 10' 5.25" 12' 3.00" 320 80 Live
1 2
12 3 0
12 3 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3295# --
2 12' 3.000" Wall N/A N/A 1.500" 3295# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 2705# 591#
2 2705# 591#
Design spans
11' 8.250"
Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 9628.# 21774.# 44% 6.02' Total Load D+L
Shear 2849.# 9476.# 30% 0.19' Total Load D+L
TL Deflection 0.3156" 0.5844" L/444 6.02' Total Load D+L
LL Deflection 0.2590" 0.3896" L/541 6.02' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
4 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG6 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 11.7 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 6' 3.00" 47 101 Snow
Replacement Uniform (PLF) Top 0' 0.00" 6' 3.00" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 16' 3.00" 9 2 Live
Replacement Uniform (PLF) Top 5' 7.00" 16' 3.00" 49 16 Live
Replacement Uniform (PLF) Top 6' 3.00" 16' 3.00" 27 7 Live
Replacement Uniform (PLF) Top 10' 2.94" 16' 3.00" 47 101 Snow
Point (LBS) Top 6' 3.00" 5 687 Live
Point (LBS) Top 6' 3.00" 1669 0 Snow
Point (LBS) Top 10' 2.94" 5 691 Live
Point (LBS) Top 10' 2.94" 1677 0 Snow
Point (LBS) Top 15' 10.38" 0 99 Live
Point (LBS) Top 15' 10.38" -7 433 Live
Point (LBS) Top 15' 10.38" 896 0 Snow
1 2
16 3 0
16 3 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 3378# --
2 16' 3.000" Wall N/A N/A 1.500" 4987# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 449# 1899# 1479#
2 617# 2888# 2098#
Design spans
15' 8.250"
Product: 1-3/4x11-7/8 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 17418.# 24466.# 71% 6.25' Total Load D+S
Shear 3377.# 9081.# 37% 15.08' Total Load D+S
TL Deflection 0.7815" 0.7844" L/240 8.02' Total Load D+S
LL Deflection 0.4726" 0.5229" L/398 8.02' Total Load S
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
5 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG8 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.1 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 6' 2.25" 6 1 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 7.75" -53 -13 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 7.75" 27 7 Live
Replacement Uniform (PLF) Top 0' 0.00" 10' 7.75" 40 13 Live
Replacement Uniform (PLF) Top 6' 2.25" 10' 7.75" -53 -13 Live
Replacement Uniform (PLF) Top 6' 2.25" 10' 7.75" 27 7 Live
Replacement Uniform (PLF) Top 6' 2.25" 10' 7.75" 27 13 Live
Point (LBS) Top 6' 4.00" 74 60 Live
1 2
10 7 12
10 7 12
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 606# -355#
2 10' 7.750" Girder N/A N/A N/A 795# -515#
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Dead
1 429# 177#
2 560# 235#
Design spans
9' 11.875"
Product: Hem-Fir (N) #2 2 x 10 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Review gravity uplift reaction force of 355lbs at bearing 1 and ensure that the structure can resist appropriately.
Review gravity uplift reaction force of 516lbs at bearing 2 and ensure that the structure can resist appropriately.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1833.# 3922.# 46% 6.21' Total Load D+L
Negative Moment 1047.# 3922.# 26% 6.18' Total Load D+L
Shear 667.# 2682.# 24% 9.71' Total Load D+L
LL Deflection 0.0708" 0.3330" L/999+ 5.21' Total Load L
TL Deflection 0.1013" 0.4995" L/999+ 5.21' Total Load D+L
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
This member has been designed in accordance with NDS 2005
Minimum bearing length requirements at hangared connections depend on the connection style and are not included in this design.
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlperRevised051615 -7- 1-15
11:06am
6 of 6
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcG9 Member Type: Girder Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 14.7 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 10' 8.00" 157 52 Live
Replacement Uniform (PLF) Top 10' 8.00" 12' 8.00" 157 52 Live
Replacement Uniform (PLF) Top 12' 8.00" 16' 0.00" 45 22 Live
Point (LBS) Top 12' 6.25" 44 109 Live
Point (LBS) Top 15' 7.38" -23 -6 Snow
Point (LBS) Top 15' 7.38" 0 45 Live
Point (LBS) Top 15' 7.38" 0 60 Live
Point (LBS) Top 15' 7.38" 172 0 Snow
1 2
16 0 0
16 0 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 1701# --
2 16' 0.000" Wall N/A N/A 1.500" 1557# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 1176# 0# 525#
2 934# 149# 616#
Design spans
15' 2.750"
Product: Douglas Fir-Larch (N) #1 6 x 12 1 ply PASSES DESIGN CHECKS
NOTE: Pass-thru framing is required at point loads over bearings.
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 6440.# 13133.# 49% 8' Total Load D+L
Shear 1486.# 7168.# 20% 0.4' Total Load D+L
LL Deflection 0.1630" 0.5076" L/999+ 8' Total Load L
TL Deflection 0.2403" 0.7615" L/760 8' Total Load D+L
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
This member has been designed in accordance with NDS 2005
Point loads over bearings are NOT included in the Design calculations, but ARE included in the Reaction table