31A-088 1st floor header CalcsCS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlper041415 - Level 8 5-21-15
10:59am
1 of 3
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcB1 Member Type: Beam Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 8.4 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 6' 3.00" 564 275 Snow
1 2
6 3 0
6 3 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 2606# --
2 6' 3.000" Wall N/A N/A 1.500" 2606# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Snow Dead
1 1734# 872#
2 1734# 872#
Design spans
6' 1.750"
Product: Spruce-Pine-Fir #2 2 x 10 3 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 4004.# 6807.# 58% 3.12' Total Load D+S
Shear 1953.# 4308.# 45% 0.06' Total Load D+S
LL Deflection 0.0436" 0.2049" L/999+ 3.12' Total Load S
TL Deflection 0.0655" 0.3073" L/999+ 3.12' Total Load D+S
Control: Positive Moment
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 15 %
This member has been designed in accordance with NDS 2005
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlper041415 - Level 8 5-21-15
10:59am
2 of 3
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcB2 Member Type: Beam Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 26.6 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 6' 10.25" 455 0 Snow
Replacement Uniform (PLF) Top 0' 0.00" 6' 10.25" 439 422 Live
Replacement Uniform (PLF) Top 6' 10.25" 8' 9.50" 700 0 Snow
Replacement Uniform (PLF) Top 6' 10.25" 8' 9.50" 439 541 Live
Replacement Uniform (PLF) Top 8' 9.50" 18' 3.00" 700 0 Snow
Replacement Uniform (PLF) Top 8' 9.50" 18' 3.00" 360 541 Live
1 2
18 3 0
18 3 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 2.815" 11083# --
2 18' 3.000" Wall N/A N/A 3.073" 12101# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 3792# 4997# 4492#
2 3433# 6039# 4998#
Design spans
18' 1.750"
Product: 1-3/4x18 VERSA-LAM 2.0 3100 SP 3 ply PASSES DESIGN CHECKS
Minimum 2.81" bearing required at bearing # 1
Minimum 3.07" bearing required at bearing # 2
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 53712.# 83733.# 64% 9.12' Total Load D+0.75(L+S)
Shear 10057.# 20648.# 48% 17.29' Total Load D+0.75(L+S)
TL Deflection 0.6205" 0.9073" L/350 9.12' Total Load D+0.75(L+S)
LL Deflection 0.3666" 0.6049" L/594 9.12' Total Load 0.75(L+S)
Control: TL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Design assumes a repetitive member use increase in bending stress: 4 %
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives
CS Structure™ 2.10.1 [Build 1]
kmBeamEngine 4.13.4.1
Materials Database 1527
AlperGlenAlper041415 - Level 8 5-21-15
10:59am
3 of 3
All product names are trademarks of their respective owners
Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The
design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications.
Doug Hodgins
rk Miles Inc.
21 West St.
West Hatfield Ma.
Member Data
Description: CalcB3 Member Type: Beam Application: Floor
Comments:Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total
Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF
Filename: Q:\AlperGlen
Other Loads
Type
(Description) Side Begin End
Trib.
Width
Other
Start End
Dead
Start End Category
Replacement Uniform (PLF) Top 0' 0.00" 1' 8.50" 28 54 Snow
Replacement Uniform (PLF) Top 7' 10.50" 9' 7.00" 28 54 Snow
Point (LBS) Top 1' 8.50" 5 776 Live
Point (LBS) Top 1' 8.50" 1919 0 Snow
Point (LBS) Top 7' 10.50" 5 776 Live
Point (LBS) Top 7' 10.50" 1919 0 Snow
1 2
9 7 0
9 7 0
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall N/A N/A 1.500" 2876# --
2 9' 7.000" Wall N/A N/A 1.500" 2876# --
Maximum Load Case Reactions
Used for applying point loads (or line loads) to carrying members
Live Snow Dead
1 5# 1966# 911#
2 5# 1966# 911#
Design spans
9' 5.750"
Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 4682.# 16051.# 29% 4.79' Total Load D+S
Shear 2803.# 7265.# 38% 0.06' Total Load D+S
TL Deflection 0.1739" 0.4740" L/654 4.79' Total Load D+S
LL Deflection 0.1198" 0.3160" L/949 4.79' Total Load S
Control: Shear
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives