Loading...
31A-088 1st floor header CalcCS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 AlperGlenAlperRevised051615 -7- 1-15 11:08am 1 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB1 Member Type: Beam Application: Floor Comments:Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 9.4 PLF Filename: Q:\AlperGlen Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 1' 7.50" 28 54 Snow Replacement Uniform (PLF) Top 7' 9.50" 9' 7.00" 28 54 Snow Point (LBS) Top 1' 7.50" 5 765 Live Point (LBS) Top 1' 7.50" 1891 0 Snow Point (LBS) Top 7' 9.50" 5 765 Live Point (LBS) Top 7' 9.50" 1891 0 Snow 1 2 9 7 0 9 7 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 2880# -- 2 9' 7.000" Wall N/A N/A 1.500" 2795# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Snow Dead 1 5# 1969# 910# 2 5# 1906# 889# Design spans 9' 5.750" Product: 1-3/4x9-1/2 VERSA-LAM 2.0 3100 SP 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 4723.# 16051.# 29% 7.79' Total Load D+S Shear 2807.# 7265.# 38% 0.06' Total Load D+S TL Deflection 0.1714" 0.4740" L/663 4.79' Total Load D+S LL Deflection 0.1180" 0.3160" L/963 4.79' Total Load S Control: Shear DOLs: Live=100% Snow=115% Roof=125% Wind=160% Manufacturer's installation guide MUST be consulted for multi-ply connection details and alternatives CS Structure™ 2.10.1 [Build 1] kmBeamEngine 4.13.4.1 Materials Database 1527 AlperGlenAlperRevised051615 -7- 1-15 11:08am 2 of 2 All product names are trademarks of their respective owners Copyright (C) 2015 by Simpson Strong-Tie Company Inc. ALL RIGHTS RESERVED.**Passing is defined as when the member, floor joist, beam or girder, shown on this drawing meets applicable design criteria for Loads, Loading Conditions, and Spans listed on this sheet. The design must be reviewed by a qualified designer or design professional as required for approval. This design assumes product installation according to the manufacturer`s specifications. Doug Hodgins rk Miles Inc. 21 West St. West Hatfield Ma. Member Data Description: CalcB5 Member Type: Beam Application: Roof Comments:Top Lateral Bracing: Continuous Slope: 0.00 / 12 Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 0 PLF Deflection Criteria: L/360 live, L/240 total Dead Load: 0 PLF Deck Connection: Nailed Member Weight: 6.8 PLF Filename: Q:\AlperGlen Other Loads Type (Description) Side Begin End Trib. Width Other Start End Dead Start End Category Replacement Uniform (PLF) Top 0' 0.00" 8' 3.00" 36 10 Live 1 2 8 3 0 8 3 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall N/A N/A 1.500" 215# -- 2 8' 3.000" Wall N/A N/A 1.500" 215# -- Maximum Load Case Reactions Used for applying point loads (or line loads) to carrying members Live Dead 1 146# 69# 2 146# 69# Design spans 8' 1.750" Product: Spruce-Pine-Fir #2 2 x 12 2 ply PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 438.# 4614.# 9% 4.13' Total Load D+L Shear 166.# 3038.# 5% 7.38' Total Load D+L LL Deflection 0.0071" 0.2715" L/999+ 4.13' Total Load L TL Deflection 0.0105" 0.4073" L/999+ 4.13' Total Load D+L Control: Positive Moment DOLs: Live=100% Snow=115% Roof=125% Wind=160% This member has been designed in accordance with NDS 2005