22D-057 Hamlen PERMIT-LayoutPOSSIBLE
CLOSET
CLOSET CLOSETNEW DBL CASEMENT WINDOWTO MEET EGRESS - 57" W x 44" H36" MIN.
CLEAR
NEW DBL CASEMENT WINDOW
TO MEET EGRESS - 57" W x 44" H
BEDROOM
NEW TRANSOM WINDOW
12"H x 48"W, TYP.
EA BEDROOM
CARPET
STAIR
DOWN
MASTER
BEDROOM
BEDROOM
HALL
BATH
CARPET
NO CHANGE
NEW CARPET
NEW CARPET
NEW CARPET
NEW CARPET
NEW FRAME FOR
STAINED GLASS
PIECE BY OWNER,
SIZE TBD.
ADD 6'-0" OF NEW ELECTRIC
BASEBOARD HEAT THIS ROOM,
LOCATION TBD.
PAINTED BEADBOARD
WAINSCOTING ON
ALL HALLWAY WALLS.
NEW
CARPET
ON
STAIRS NEW DBL CASEMENT WINDOWTO MEET EGRESS - 57" W x 44" H266826685046
2668
CO/SD
CO/Smoke Detector
SD
Smoke Detector
SD
Smoke Detector
SD
Smoke Detector
4'-2 15/16"7'-11"7'-3"9'-5"2'-2"8'-9 1/2"13'-1"10'-7 1/16"13'-3 1/2"26'-11"
2'-5"
CHIMNEY REMOVE
WINDOW
CLOSET CLOSET
REMOVE
WINDOW
REMOVE
WINDOW
REMOVE ALL
CARPET EXCEPT
LARGE CLOSETS
CARPET TO REMAIN
STAIR
DOWN
MASTER
BEDROOM
REMOVE STAIR
RAILING AS NEEDED
BATH
CARPET TO REMAIN
TILE
RELOCATE THIS
LIGHT TO NEW
HALLWAY
DORMER WALL, TYP.
CARPET
WINDOW TO REMAIN
CHIMNEY
NEW WORK:
SECOND FLOOR PLAN -
EXISTING CONDITIONS
SCALE - 1/4" = 1'-0"DADMUNSECOND FLOOR PLAN - PROPOSED
SCALE - 1/4" = 1'-0"
OVERVIEW PERSPECTIVE
SCALE - NONE
DOUBLE HUNG WINDOWS TO BE REMOVED
AND REPLACED WITH DOUBLE CASEMENT
UNITS TO MEET EGRESS CODE.
EXISTING CONDITIONS
NEW DOUBLE CASEMENT
UNITS TO MEET EGRESS CODE.
1
EXISTING
&
PROPOSED
PLANS17 FLORENCE RD.FLORENCE, MA 01062Design + ConstructionHAMLEN RESIDENCE -2ND FLOOR REMODELCLIENT INFO:PROJECT:DRAWING TYPE:Design . Build . RemodelSHEET:
SCALE: AS STATED
ALL DRAWINGS, PLANS, & DESIGNS ARE PROPERTY OF THE TUCKER GROUP, LLC60 SCHOOL STREET, HATFIELD, CT 01038DRAWN BY: T. DADMUNDATE: 04/21/2015PERMITDRAWING PHASE:- DIVIDE THE 2ND FLOOR SPACE TO CREATE THREE BEDROOMS,
EACH MEETING THE 70SF MINIMUM AND CEILING HEIGHT
REQUIREMENTS. FRAME NEW WALLS AS PER PLAN.
- INSTALL THREE NEW, 30" x 80" ENTRY DOORS TO THE BEDROOMS.
- REMOVE THE DOUBLE HUNG WINDOWS IN THE NEW BEDROOMS
AND REPLACE WITH NEW DBL CASEMENTS TO MEET EGRESS CODE,
INTEGRITY MODEL # ICA 57" W x 44" H.
- PROVIDE NEW SMOKE DETECTORS IN EACH OF THE THREE BEDROOMS,
ONE COMBINATION SMOKE / CO DETECTOR ON EACH OF THE HOME'S
LEVELS, BASEMENT, FIRST AND SECOND, AND INSTALL NEW ELECTRICAL
OUTLETS AND SWITCHING TO CODE.
- MODIFY STAIR RAILINGS TO MEET CODE.
- INSTALL SOUND ATTENUATION BLANKETS IN NEW BEDROOM WALLS.
- INSTALL NEW CARPET FLOORING INCLUDING THE STAIRS.