(SIGNED)CornerHouse_Legacy_20161102-FP-1SEE SYSTEM NOTE 3.4
THIRD FLOORSCALE 18" = 1'-0"114" x 9'-1" CPVC DNTO 2ND FLOORSTAIRS TO BEHEATED BY OTHERSSEE SYSTEM NOTE 3.4
STAIR RAILING
STAIR RAILINGSTAIR RAILINGSECOND FLOORSCALE 18" = 1'-0"STAIRS TO BEHEATED BY OTHERSRUN IN JOIST SPACERUN IN JOIST SPACE114" x 9'-1" CPVC UP
TO 3RD FLOORSTAIR RAILINGFIRST FLOORSCALE 18" = 1'-0"STAIRS TO BEHEATED BY OTHERSRUN IN JOIST SPACERUN IN JOIST SPACE114" x 10'-0" CPVC UP
TO 2ND FLOOR
STAIRS COVERED FROM ABOVE
STAIR RAILINGCONCEALED SPACE
NOT USED FOR
STORAGE ²BASEMENTSCALE 18" = 1'-0"STAIRS TO BEHEATED BY OTHERS114" x 10'-4" CPVC UP
TO 1ST FLOOR VISUAL BEACON BY OTHERSSTAIR RAILINGFDC & ELECTRIC BELLBY FP CONTRACTORNEW - GENERALVALUEGENERAL NOTES:1.SYSTEM INSTALLATION SHALL CONFORM TO NFPA-13R 2013 EDITION FOR UNITS 1-6 ANDNFPA-13 2013 EDITION FOR THE BASEMENT.2.OWNER IS REQUIRED TO PROVIDE HEAT THROUGHOUT THE ENTIRE BUILDING TO MAINTAINA MINIMUM TEMPERATURE OF 40 DEGREES FAHRENHEIT FOR ALL AREAS PROTECTED WITHA WET PIPE SPRINKLER SYSTEM. THE SYSTEM IS TO BE MAINTAINED BY THE OWNER ASREQUIRED BY NFPA-25.3.BASEMENT PIPING:3.1.PIPE 114" & LARGER TO BE SCHEDULE 10 BLACK STEEL WITH WELDED OUTLETS ANDGROOVED ENDS & FITTINGS3.2.PIPE 1" IN DIAMETER TO BE SCHEDULE 40 BLACK STEEL WITH THREADED ENDS &FITTINGS4.FLOORS 1 THROUGH 3 PIPING:4.1.PIPE TO BE CPVC WITH CPVC FITTINGS AND APPROVED SOLVENT CEMENT.5.PIPE SHALL BE SUPPORTED AS REQUIRED BY NFPA-13. HANGERS ARE TO BE FIELD LOCATEDTO BEST SUPPORT THE PIPE.6.STRUCTURAL LOAD BEARING ANALYSIS OF THE FIRE SPRINKLER SYSTEM AND IT'S RELATEDCOMPONENTS HAS NOT BEEN INCLUDED AS PART OF THIS CONTRACT.7.WORK IS LIMITED TO THE SPRINKLER SCOPE INDICATED ON THIS DRAWING.8.SPRINKLER SCOPE TO START AT A FLANGED CONNECTION 2'-0" ABOVE F.F. INSIDE THEBUILDING.9.UPRIGHT DEFLECTOR DISTANCE 1"-6" MAX BELOW STRUCTURAL MEMBERS IN BASEMENT.9.1.ALL UPRIGHT HEADS SHALL HAVE HEAD GUARDS10.SIDEWALL DEFLECTOR DISTANCE 4"-6" MAXIMUM BELOW CEILING.10.1.MAXIMUM COVERAGE AREA OF 324ft²10.2.MAXIMUM WIDTH X LENGTH = 18'-0" X 18'-0"10.3.MAXIMUM DISTANCE OF WALL = 9'-0"11.OWNER TO MAINTAIN 18" OF CLEARANCE FROM SPRINKLER DEFLECTOR TO TOP OFPENDENT LIGHT FIXTURES & STORAGE.12. DENOTES HYDRAULIC REFERENCE POINT.SYSTEM NOTES:1.CONSTRUCTION IS COMBUSTIBLE.2.OCCUPANCY: RESIDENTIAL UNITS WITH A BASEMENT USED FOR TENANT STORAGE2.1.RESIDENTIAL UNITS DENSITY: RESIDENTIAL, 0.05 GPM OVER FOUR HEADS WITH 100 GPMHOSE STREAM PER NFPA-13R & MFG. REQUIREMENTS.2.2.BASEMENT DENSITY: ORDINARY HAZARD GROUP I, 0.15 GPM OVER 989ft² WITH 250 GPMHOSE STREAM2.3.AREA OF OPERATION WAS REDUCED BY 40% PER NFPA-13 SECTION 11.2.3.2.33.SPRINKLER OMISSIONS PER NFPA-13R SECTION 6.6 FOR APARTMENT UNITS:3.1.BATHROOMS ≤ 55ft²3.2.CLOSETS ≤ 24ft² w/ THE LEAST DIMENSION ≤ 3ft3.3.ATTICS, CRAWL SPACES, FLOOR/CEILING SPACES, AND OTHER CONCEALED SPACESTHAT ARE NOT USED OR INTENDED FOR LIVING PURPOSES OR STORAGE AND DO NOTCONTAIN FUEL-FIRED EQUIPMENT.180.11 GPM at 96.927 PSIDemand at Base of Riser80.11 GPM at 88.451 PSIHYDRUALIC REMOTE AREA #14 Sprinklers OperatingDensity 0.05 GPM Over 4 Heads100 GPM for hose streamTotal Demand at City MainSYSTEM SAFETY FACTOR: 22.50 PSI 476.74 GPM at 98.472 PSIDemand at Base of Riser226.74 GPM at 50.340 PSIHYDRUALIC REMOTE AREA #211 Sprinklers OperatingDensity 0.15 GPM Over 989ft²250 GPM for Hose StreamTotal Demand at City MainSYSTEM SAFETY FACTOR: 18.06 PSIWATER FLOW TEST INFORMATIONSTATIC:120 PSIRESIDUAL: 103 PSIFLOW: 1126 GPMHYDRANT COEF: 0.9HYDRANT OUTLET SIZE: 212"PITOT: 45 PSITIME: 08:00 A.MDATE OF TEST: 18 OCT 2016FLOW TEST PERFORMED BY:NORTHAMPTON WATER DEPT, &LEGACY FIRE PROTECTIONELEVATION: GAUGE HYDRANT IS5'-0" HIGHER THAN THE BASEMENTFINISH FLOOR.FLOW HYDRANTNEW 2" UG FIRE
SERVICE (100')GAUGE HYDRANTBRIDGE STREETSITE PLANSCALE 1"=20'-0"CORNER HOUSESHAW HOTEL9,100 FT²NEW 2" SERVICE BYOTHERS PER NFPA-13 & 24NEW 2" GATE VALVEBY OTHERSEXISTING 12" LOOPEDTOWN WATER MAINNEW 212" STORZ& ELECTRIC BELL BYFP CONTRACTOR;VISUAL BEACONPROVIDED BY OTHERSTOP OF SECOND FLOOR: 18'-3.5"TOP OF FIRST FLOOR: 7'-11.5"TOP OF THIRD FLOOR: 28'-3.5TOP OF BASEMENT SLAB: 0'-0"GROUND: 5'-0"ELEVATION VIEWNOT TO SCALETSTSFS128934567RISER DIAGRAMNO SCALE2.5"2"2"2"2"1011STYLECOLORHEADK =NPTORIF.ESCUT.WRENCHCNTSYMSPRINKLER SYMBOLSMFG.C-PLATETEMP(SIN) #TEMPMODEL#7RELIABLEF3Res44SIDEWALLWHITE155°N/A4.41"1/2"F2; 24" LENGTHMODEL F3RA523119VICTAULICV27UPRIGHTBRASS155°N/A5.61/2"1/2"V27 GUARDMODEL V27V270448RELIABLEF1Res44SIDEWALLWHITE155°N/A4.41/2"3/8"F2MODEL GRF2RA3331NOTE: SPRINKLER HEADS WITHIN 2'-6" OF ALL DIFFUSERS SHALL BE INTERMEDIATE TEMPERATURE.6RELIABLEF1Res44SIDEWALLWHITE175°N/A4.41/2"3/8"F2MODEL GRF2RA3331POSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 1 ft.1 ft to less than 1 ft 6 in1 ft 6 in to less than 2 ft2 ft to less than 2 ft 6 in2 ft 6 in to less than 3 ft3 ft to less than 3 ft 6 in3 ft 6 in to less than 4 ft4 ft to less than 4 ft 6 in4 ft 6 in to less than 5 ft5 ft to less than 5 ft 6 in5 ft 6 in to less than 6 ft6 ft to less than 6 ft 6 in6 ft 6 in to less than 7 ft7 ft to less than 7 ft 6 inMaximum Allowable Distanceof Deflector Above Bottom02 1/23 1/25 1/27 1/29 1/2121416 1/21820243035of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE (SSU/SSP)POSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 1 ft.1 ft to less than 1 ft 6 in1 ft 6 in to less than 2 ft2 ft to less than 2 ft 6 in2 ft 6 in to less than 3 ft3 ft to less than 3 ft 6 in3 ft 6 in to less than 4 ft4 ft to less than 4 ft 6 in4 ft 6 in to less than 5 ft5 ft to less than 5 ft 6 in5 ft 6 in to less than 6 ft6 ft to less than 6 ft 6 in6 ft 6 in to less than 7 ft7 ft to less than 7 ft 6 inMaximum Allowable Distanceof Deflector Above Bottom0011133577791114of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE(Residential Upright/Pendents)POSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 4 ft.4 ft to less than 5 ft5 ft to less than 5 ft 6 in5 ft 6 in to less than 6 ft6 ft to less than 6 ft 6 in6 ft 6 in to less than 7 ft7 ft to less than 7 ft 6 in7 ft 6 in to less than 8 ft8 ft to less than 8 ft 6 in8 ft 6 or greaterMaximum Allowable Distanceof Deflector Above BottomNot Allowed12346791114of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE(Standard Sidewall Sprinklers)POSITIONING OF SPRINKLERS TO AVOIDDistance from Sprinklers toside of ObstructionsLess than 8 ft.8 ft to less than 10 ft10 ft to less than 11 ft11 ft to less than 12 ft12 ft to less than 13 ft13 ft to less than 14 ft14 ft to less than 15 ft15 ft to less than 16 ft16 ft to less than 17 ft17 ft or greaterMaximum Allowable Distanceof Deflector Above BottomNot Allowed12346791114of Obstruction (in.)OBSTRUCTIONS TO DISCHARGE(Residential Sidewall Sprinklers)MAX AREA: 130ft²MAX DIMS: 15'-0" X 15'-0"MAX AREA: 324ft²MAX DIMS: 18'-0" X 18'-0"MAX AREA: 288ft²MAX DIMS: 16'-0" X 18'-0"WET SYSTEM SPRINKLER MAINSOFFITS MUST STAY UNDER 8" INWIDTH PER NFPA-13 SECTION 8.7.4.1.3SIDEWALL SPRINKLER HEAD DEFLECTORSHALL BE 4"-6" MAXIMUM BELOW CEILING1" X 1/2" REDUCEREXISTING STUD WALLCEILINGNEW SOFFIT BYGENERAL CONTRACTORCORRIDORROOM SIDEWALL SPRINKLER HEADTYPICAL SIDEWALL SPRINKLER HEAD INSTALLATIONNOT TO SCALEHEAD COVERAGE GUIDESSCALE 14" = 1'-0"AT FLOOR PENETRATIONOR AT 10 FOOT INTERVALS, WHICHEVER IS LESS.VERTICAL PIPING SHALL BE SUPPORTED AT EACH FLOOR LEVELFLOORSNUG BUT NOT TIGHTRISER CLAMPPIPECOLLAR ADHERED TOPLASTIC COUPLING OR& TRANSITION TO STEEL BELOW FLOOR2-HOLE STANDOFF HANGERABOVE INSULATION.PIPE BELOW FLOOR &TRANSITION TO STEELVERTICAL SUPPORT OF BLAZEMASTER PIPEFLOOR JOIST(OR ABOVE FLOOR IFNO INSULATION.)CPVC SUPPORT DETAILSCALE: NTSNOTE :The Blazemaster CPVC fire sprinkler product is a Life Safety Assembly and must be treated carefully. Please readthe following before any activity which could contact this system:Read and follow the CPVC manufacturer's Installation Instructions. Training by an authorized representative isavailable and is recommended. Proof of training may be required by local authorities.CPVC piping components may be damaged by certain substances used in construction and building maintenance.ONLY system compatible materials including, but not limited to solvent cements, caulks, sealants, cutting oils andthread pastes as noted by the manufacturer's installation instructions should be used in contact with this system.DO NOT expose CPVC products to incompatible substances, such as cutting oils, non-water based paints, packingoils, traditional pipe thread paste and dope, fungicides, termiticides, insecticides, detergents, building caulks,adhesive tape, solder flux, flexible wire/cable (with special consideration for communications cabling), andnon-approved spray foam insulation materials.DO NOT expose CPVC products to edible oils, solvents, or glycol-based anti-freeze fluids.When combining metallic pipe and fittings with CPVC products in a system, the cutting oil should be removedprior to assembly.DO NOT store CPVC products in containers with metal products where it may become damaged or contaminatedwith packing oils.DO NOT handle CPVC products with gloves contaminated with oils (hydrocarbons) or other incompatiblematerials.Failure to follow the manufacturer's installation instructions and this notice may cause cracks or fractures todevelop in CPVC products, resulting in property damage due to leaks or flooding. The presence of any visiblecracks may require partial or full system replacement. Please contact the manufacturer for additional information.NEW 2" COPPER DEDICATED FIRE SERVICE2 1/2" x 2" GROOVED CONCENTRIC REDUCER2" GROOVED ELBOW2" GROOVED CHECK VALVE TO FDC2 1/2" STORZ FDC 2'-0" ABOVE GROUND12" VICTAULIC 747M RISER MANIFOLD WITH FLOW SWITCH, INSPECTORSTEST/DRAIN, RELIEF VALVE, & GAUGE2" GROOVED ELBOW TO SYSTEM RISER DETAIL LEGENDQUANTITY11111111111123456892 1/2" ZURN-WILKINS 350AST DOUBLE CHECK VALVE BACKFLOWWITH GROOVED BUTTERFLY VALVES & TAMPER SWITCHES2 1/2" x 2" GROOVED CONCENTRIC REDUCER2 1/2" x 2" GROOVED CONCENTRIC REDUCER1710RISER STAND11RELIABLE K4.4 DRY RESIDENTIAL SPRINKLERRA5231RELIABLE K4.4 WET RESIDENTIAL SPRINKLER187.95 GPM at 94.581 PSIDemand at Base of Riser87.95 GPM at 84.828 PSIHYDRUALIC REMOTE AREA #34 Sprinklers OperatingDensity 0.05 GPM Over 4 Heads100 GPM for hose streamTotal Demand at City MainSYSTEM SAFETY FACTOR: 24.80 PSI