Loading...
R IECCUA15 0073-0182 Matt C 87 Bridge St. Nhton RIGHT side rt2015 IECC Building UA Compliance Property Matthew Campagnari 87 Bridge Street - Righr SIDE Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duples Right HERS_0073_0182_Matt C 87 Bridge St. Nhton RIGHT side Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0182 Rater ID:8776762 DRAFT REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. Elements Insulation Levels 2015 IECC As Designed Shell UA Check Ceilings:29.2 28.5 Above-Grade Walls:92.8 89.2 Windows and Doors:52.2 45.9 Slab Floor, Heated:5.4 2.9 Floors Over Garage:9.7 8.5 Overall UA (Design must be equal or lower):189.3 174.9 Mandatory Requirements Shell UA Check PASSES Duct Insulation R-Value Check (per Section 403.3.1)PASSES Window U-Value and SHGC Check (per Section 402.5)PASSES Home Infiltration (Section 402.4.1.2)PASSES Duct Testing (Section 403.3.3)PASSES Mechanical Ventilation (Section 403.6)PASSES Mechanical Ventilation Fan Efficacy (Section 403.6.1)PASSES Mandatory Requirements Check Box (2015 IECC)PASSES This home MEETS the overall thermal performance requirements and verifications of the International Energy Conservation Code based on a climate zone of 5A. (Section 402, International Energy Conservation Code, 2015 edition.) In fact, this home surpasses the requirements by 7.6%. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 22 March 2017 2015 IECC Energy Cost Compliance Property Matthew Campagnari 87 Bridge Street - Righr SIDE Northampton, MA 01077 Weather:Chicopee, MA Bridge Street Duples Right HERS_0073_0182_Matt C 87 Organization Noonan Energy Corp 413-427-2423 Paul J. DellaTorre Builder Matthew Campagnari HERS ProjectedWorstCase 2017-03-22 Rating No:0073_0182 Rater ID:8776762 REM/Rate - Residential Energy Analysis and Rating Software v15.3 This information does not constitute any warranty of energy cost or savings. © 1985-2016 Noresco, Boulder, Colorado. DRAFT Annual Energy Cost $/yr 2015 IECC As Designed Heating 526 564 Cooling 67 53 Water Heating 193 193 SubTotal - Used to Determine Compliance 786 810 Lights & Appliances 872 797 Photovoltaics -0 -0 Service Charge 192 192 Total 1850 1800 Mandatory Requirements The following Mandatory Requirements Fail: Annual Energy Cost Check Design must be equal or lower 786 810 This home DOES NOT meet the annual energy cost requirements of Section 405 of the 2015 International Energy Conservation Code based on a climate zone of 5A. Name Paul J. DellaTorre Signature Organization Noonan Energy Corp Date 22 March 2017 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2015 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards.