Loading...
23A-101 Fair St All 2013-08-12City of Northampton, MA: Residential Property Record Card New Search Property Type Classification Code Reference Card 1 of 1 Parcel - Location - Zoning - Assessment Map-Block-Lot:25C-255-001 Location:23 FAIR ST #Living Units:1 Class:R-101 Zoning: Neigborhood:20 Deed Book:0850 Deed Page:001 Assessment: Land: 60,200 Building: 87,500 Total: 147,700 Dwelling Information Building Sketch Style:Conventional Year Built:1900 Story Height:1.5 Attic:None Basement:Full Total Rooms:7 Bedrooms:3 Full Baths:1 Half Baths:0 Exterior Walls:Alum/Vinyl Unfinished Area:0 Ground Floor Area:572 Total Living Area:1238 Finished Basement Living Area:0 X 0 Basement Recreation Area:0 X 0 Woodburning Fireplace Stacks/Openings:0 / 0 Metal Fireplace Stacks/Openings:0 / 0 Heat/Central A/C:Basic Heating System:Warm Air Fuel Type:Gas Quality Grade:C Physical Condition:Average Interior/Exterior:Same Condition/Desirability/Utility:AV Vacant/Dwell/Oby Status:Dwelling Additional Features: Brick Trim:0 X 0 Stone Trim:0 X 0 Remodeling Data: Year Remodeled:0 Kitchen Remodeled (Y/N): Bath Remodeled (Y/N): Addition Information: Lower 1st Story 2nd Story 3rd Story Area Basement One Story Frame Half Story Frame 572 Basement One Story Frame 192 One Story Frame 45 Open Frame Porch 12 Open Frame Porch 28 Land Data Outbuilding Info Square Foot Type Type SQ Feet Value Prime Site 10,500 60,170 Utilities no information Acreage Type Type Acres Value no information Street/Road no information Type Qty Year Size 1 Size2 Grd Cond RS1 1 1910 1 144 D U RS1 1 1910 1 280 D U Sales Info Permit Info Date Type Price Validity no information Date Permit # Price Purpose no information Northampton, MA Property Detail http://www.northamptonassessor.us/noho/propertydetail.php?map_no=25... 1 of 1 1/22/2013 8:30 AM City of Northampton Massachusetts DEPARTMENT OF BUILDING INSPECTIONS 212 Main Street ● Municipal Building Northampton, MA 01060 INSPECTOR M.E. Builders March 11, 2013 33 Hillside Road Montague, MA 01351 Subject Location: 23 Fair Street, Northampton Map Block: 25C-255 Mr. John, Your building permit application and plans dated 12-04-2012 with TNT engineering dated 12-2012 and RK Miles Floor engineering dated 12-21-12 is approved as drawn and per this memo. All work must meet all applicable codes whether noted or not. Please follow up on the following items: These items will need to be accomplished as the project moves forward and before rough inspections; 1. A plot plan showing the structure with the porches and decks with dimensions to boundaries. 2. A drawing showing the details of any porches and decks before framing begins. 3. A vapor barrier is required over the ground in the crawl space, sealed to the foundation. 4. The main carrying beam will below base flood elevation and has to be rot resistant. (PT) 5. The floor system insulation must be enclosed within an air tight cavity. 6. An initial and final HERS rating is required. 7. Manual J calculations and equipment specification are required. 8. Any modifications to engineered plans require an SK from the engineer responsible. As of August 4th 2011 the 8th Edition MA code is the 2009 IRC with MA amendments. In the following are some generic requirements which seem to be problematic. This is not a substitute for purchasing and reading the MA codes. 1. Structures shall conform to 780 CMR 8th Edition 1 and 2 family building codes with MA amendments. 2. Grading plan for structures being constructed required. 780 CMR R401.3 for drainage requirements. 3. A basement drainage system is required in all basements 780 CMR R405.2.3. except those in group I soils (table R405.1) 4. Foundations that retain earth and enclose interior space require damp proofing 780 CMR R406.1. 5. Ceiling joist are intended to prevent spread, once raised above the wall plate they become rafters ties and may require up sizing of rafters and increased nailing for example with a 4” slope 8-16nd common are required at each connection. 780 CMR R802.3.1. 6. Steel straps over the ridge or 1x4 minimum collar ties are required 4’ OC in the upper 1/3rd 780 CMR R802.3.1 7. Ridge boards must be the full depth of the cut. 780 CMR R802.3. 8. A complete window and header schedule is required. 780 CMR Table R502.5 for header sizing and number of jack studs required. 9. All framing materials which are not code prescriptive must have stamped engineering. a. LVLs b. I-joist and or Floor Truss c. Roof truss 10. A braced wall plan identifying appropriate braced wall areas and braced wall method being used. 780 CMR 602.10. a. Garage corners and large corner window/door layout may require special solutions. b. All corners must be appropriately attached to the foundation. 11. Ceiling heights minimum 7’ for habitable spaces, 6’8” for bathrooms includes tub/shower area if a shower head is used, 6’8” for basements, 6’4” at beams/ducts. 780 CMR R305.1. MA amended 12. Hazardous glazing locations, within 24” of a door, or within 60” of a stair, or across from hot tubs, spas, bathtubs within 60” if not 60” above the walking surface, and other locations. 780 CMR R308.4 13. Windows over 72” above grade with the opening less than 24 above the finished floor shall meet the 4” sphere rule. Order restrictors. 780 CMR R612.2 14. Egress and emergency escape requirements shall be strictly met. a. Basements, habitable attics, and all sleeping rooms require emergency escape. 780 CMR R310 b. Windows within 44” of floor, DH 3.3 sqft min window size, Casement 20”x41” exception 5 sqft at 1st floor. Minimum clear opening 20”x24” or 24”x20”. 780 CMR R310.1.1 c. Two doors remote as possible at the normal level of travel, opening measured from the face of the slab to the stop with door at 90 degrees, one 32” and one 28” minimum 78” high. 780 CMR R311.2 d. Landing at each door 36” out and the width of the door minimum 36”, maximum step 7 ¾” from the top of the threshold and only in-swinging doors. 780 CMR R311.3 15. Stairs have critical standards, make sure you know the floor finishes when planning. Minimum tread 9”, maximum riser 8 ¼”, maximum overall variance for the run is 3/8”, 4” sphere rule on risers except where the total rise is 30” or less 780 CMR R311.7.4.3 Exception, 4 3/8” on balustrade, 6” in the triangle. Graspable rail 1 ¼” minimum and 2” maximum rail, height minimum 34” maximum 38”, required for 4 or more risers. Landing to landing constitutes a new run. Minimum 6’8” ceiling height from nosing. 780 CMR R311.7. 16. Guards 36” minimum height above walking surface, a bench is a walking surface, required for more than 30” above floor or grade within 36”, 4” sphere rule. 780 CMR R312.1. 17. Educate the plumber and electrician about maximum notch and hole sizes, and placement. 780 CMR R502.8 and R602.6. In bearing studs holes not larger than 40% of a stud no closer than 5/8 to the edge, In interior non-bearing studs holes not larger than 60% of a stud no closer than 5/8 to the edge, in bearing walls if more than 50% of a plate is cut or notched a 1 ½” 16ga. strap must extend a minimum of 6” past the cut both directions and be nailed with 8-10d per side, or holes in joist are a maximum 1/3 the depth not closer than 2” from the top or bottom. Notches are different. 18. Dryer duct transition is limited to 8’ of aluminum flex and must be exposed. 780 CMR M1502.4.3 19. Dryer duct maximum equivalent length is 25’ including the transition section or per manufacturer’s specs. 780 CMR M1502.4.4.1, no screwed connections. 20. Concealed dryer ducts are required to have a label within 6’ of the dryer connection stating the equivalent length and risk of fire. See CMR 780 M1502.4.5 21. Markup air is required for any exhaust hood of 400 CFM or more. 780 CMR M1503.4 22. Fireplaces require all combustion air be provided from the exterior and below the firebox, duct work maintaining 1” clearance for 5’ from the duct outlet for all fireplaces 23. Fire and draft stopping shall be completed before rough inspection. 780 CMR R302. 24. Ignition barriers in place before final. 780 CMR R316. 25. Energy aspects shall comply with the stretch energy code. 780 CMR Appendix 115AA or 2009 IECC. a. An initial HERS evaluation is required including insulation levels anticipated. b. A final HERS evaluation confirming code requirements have been met including duct testing. c. Energy information including mechanical equipment posted on the electric panel. d. Remodeling and Additions can be completed in accordance with IECC 2009 with Energy Star Building Option Package. 26. Vapor retarders. Although these are still in the code have exceptions, one must understand that there is a difference between a vapor retarder or barrier and an air barrier. An air barrier is intended to stop air flow (convection) a vapor retarder or barrier is intended to stop molecular moisture transfer (diffusion). A vapor retarder or barrier is effective even if there are some holes or gaps, however an air barrier has to be absolute and complete. If air can leak through an electrical device or through a crack it follows the path of least resistance and carries 99% of the moisture in a structure. This is evident every time one exposes fiberglass insulation and finds black insulation, which is dirt filter out of the air moving through the insulation. 780 CMR R601.2 for vapor retarders and Table N1102.4.2 for air sealing requirements. 27. Unvented attic assemblies. Hot roofs are allowed, but have specific requirements 780 CMR R806.4. 28. Deck ledgers and post must be appropriately attached, bolts or lags. 780 CMR R502.2.2.1 Note: ThruLoks are engineered for post attachment supporting a railing. 29. Smoke and CO detectors as required. 780 CMR R314 and R315. 30. Closets beneath stair which have doors must be drywalled with ½”. 780 CMR R302.7 Relevant items must be submitted to the building department for approvals before inspections and or CO can be signed. Other items are intended to avoid costly issues at inspections. Feel free to call if you have any questions. My telephone number is 587-1240 and office hours are Monday through Friday, 8:30 am to 4:30 pm, excepting we close for walk-ins at 12:00 noon on Wednesdays. My email address is: cmiller@northamptonma.gov Thank you for your cooperation on these matters. Chuck Miller City of Northampton Assistant Commissioner and Zoning Enforcement City of Northampton, MA: Residential Property Record Card New Search Property Type Classification Code Reference Card 1 of 1 Parcel - Location - Zoning - Assessment Map-Block-Lot:25C-255-001 Location:23 FAIR ST #Living Units:1 Class:R-101 Zoning: Neigborhood:20 Deed Book:0850 Deed Page:001 Assessment: Land: 60,200 Building: 91,900 Total: 152,100 Dwelling Information Building Sketch Style:Conventional Year Built:1900 Story Height:1.5 Attic:None Basement:Full Total Rooms:7 Bedrooms:3 Full Baths:1 Half Baths:0 Exterior Walls:Alum/Vinyl Unfinished Area:0 Ground Floor Area:572 Total Living Area:1238 Finished Basement Living Area:0 X 0 Basement Recreation Area:0 X 0 Woodburning Fireplace Stacks/Openings:0 / 0 Metal Fireplace Stacks/Openings:0 / 0 Heat/Central A/C:Basic Heating System:Warm Air Fuel Type:Gas Quality Grade:C Physical Condition:Average Interior/Exterior:Same Condition/Desirability/Utility:AV Vacant/Dwell/Oby Status:Dwelling Additional Features: Brick Trim:0 X 0 Stone Trim:0 X 0 Remodeling Data: Year Remodeled:0 Kitchen Remodeled (Y/N): Bath Remodeled (Y/N): Addition Information: Lower 1st Story 2nd Story 3rd Story Area Basement One Story Frame Half Story Frame 572 Basement One Story Frame 192 One Story Frame 45 Open Frame Porch 12 Open Frame Porch 28 Land Data Outbuilding Info Northampton, MA Property Detail Square Foot Type Type SQ Feet Value Prime Site 10,500 60,170 Utilities no information Acreage Type Type Acres Value no information Street/Road no information Type Qty Year Size 1 Size2 Grd Cond RS1 1 1910 1 144 D U RS1 1 1910 1 280 D U Sales Info Permit Info Date Type Price Validity no information Date Permit # Price Purpose no information Northampton, MA Property Detail File # BP-2013-0645 APPLICANT/CONTACT PERSON OBER JEREMY D ADDRESSIPHONE 8 HOCKANUM RD #14 NORTHAMPTON (413) 658-7583 () PROPERTY LOCATION 23 FAIR ST MAP 25C PARCEL 255 001 ZONE SC(100)! TillS SECTION FOR OFFICIAL USE ONLY: PERMJT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Typeof Construction: DEMOLISH HOUSE, & CONSTRUCT SF MODULAR New Construction Non Structural interior renovations _~A~ddition to Existing ___~~ory Structur~e,,-_________________________ Building Plans Included: Qwner/ Statement or License 97692 3 sets ofPlans / Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON TIllS APPLICATION BASED ON INFORMATION PRESENTED: /I __Approved ~dditional permits required (see below) C C).,...f (...... 0,.-. PLANNING BOARD PERMIT REQUIRED UNDER:§ __~~_______ Intermediate Project:~___Site Plan AND/OR ___ _Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan WNING BOARD PERMIT REQUIRED UNDER: § _________ Finding,_____ Special Permit. _______ Variance*_____ ____~Received & Recorded at Registry ofDeeds Proof Enclosed ______ __Other Permits Required: ___Curb Cut from DPW ___Water Availability ___Sewer Availability ----/eptic Approval Board ofHealth _____Well Water Potability Board of Health _V,,--_F.Permit from Conservation Commission Permit from CB Architecture Committee __-,Permit from Elm Street Commission ____Permit DPW Storm Water Management P-/J-/~ Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards ofMGL 40A. Contact Office of Planning & Development for more information. City ,of Northampton Building Department . • 212 Main Street Room 100 Northampton, MA 01060' / phone 413-587-1240 Fax 413-587-1272 , . '} .. f APPLICATION TO CONSTRUCT, ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING 1.1 Property Address: ~3. ~~v.s."'t· 2.1 Owner of Record: Name (P~)e\"~P .~ O~er Telephone . 2.2 Authorized Agent: Name Current Mailing Address: 1. Building 2. Electrical 3. Plumbing 4. Mechanical (HVAC) Section 4. ZONING t.llt Information MUst Be Completed. Permit Can Be Denied Due To Incomplete Inform~ti.on Existing Proposed Required by Loning J" This column to be filled in by Building Dep~ent ., "'~~-. Lot Size ' i I' ! '1I .L . [ l.2l5 ~~:s ! I, ~(2. ~~ • Frontage ; ill -Setbacks Front [IT] M;i CJ Side L:! I r l R:! \ IT L;i '''l!\ I R{\J.'$i_ I j I . I Rear [IT] .' am I· I Building Height 'c=1 '. ~ CJ Bldg. Square Footage ,C] .~% ~ c:J C],~" -:OpenSpaceFuotage '.-. I:" .......::.%:.:: :~:'':::=~.::-'::'''--..,..:;.-~.I.:'" .-C: .' :--.: . (Lot area minus bldg & paved I I l I I ,i .! parking) . # ofParking Spaces I I rnJ CJ . Fill: i I(volume & Location) , i r­ """'~ " """'. -,------«---­.. .. -.­-~---~ A. Has a Sp'ecial Permit/Variance/Finding ever been issued forlon the site? NO '¢ DONT KNOW 0 YES 0 IF YES, date issUed:1 I IF YES: Was the permit recordedattheRegistry ofDeeds? NO 0 DONT KNOW 0" . 'YESO IF YES; enter Book I I -Pagel I and/or Document #:...1-___---1 '­\ B. Does the site contain a brook, body of water or wetlands? NOfJ·· DONT KNOW 0 YES 0 IF YES,,_ bas .a.penTIit.been. or.need..to be;ob~ined from the Conservation Commission? Needs to be obtained' 0 . Obtained 0 'Date Issued: lr-------. C. Do any signs exist on the .property? YES . 0 NO .. IF YES, 'describe size, type and location: L.:I-:--_________________~.....)I ~-~-=-~=::=:~~_~,..?.~~:,~h~r_e_a_ny_p_r~_o_sed ~_hanges_t.o or additions,ofsjgnsi~;~d;d'f~rthe property? YES 0 NO.lS' IF Y~S, describe size, type and location~ :...1--_____________-,-___--1) E. III th~ construction activity disturb (clearing, grad;n~.avati.on. or filling) oyer 1 acre or;s it part of a common plan Wi. thatwlli distUrb over 1'acre? YES O..' .NO . . . --_._--._-----_.-._--..... -• ¥-••,,---."........----:.-~ ~~---....:--.-.-.:;'".~-.;"" ••- -•• -'-~----_•...;;:...._-'-. :.,....:..._----:-..._-.--", IF YES, then a Northampton Stonn Water Management Pennit from the DPYV is required, ...'--; o Roofing 0 Siding [0] Other [0] . Alteration of existing ·bedroom __'_Yes'$-No' Adding new bedroom Yes L N~ New Signs [0] Decks [0 Attached Narrative . Renovating unfinished basement Yes ___,No Plans Attached Roll -Sheet . Two Family Other ____a. Use ~f building: One Famiiy 'f l-I" Number of BathroomsN.umber of rooms in ea~~ familyunit: '<0 . ~ c. Is there a garage attached? (\0 d.' Proposed Square footage of new construction'_\-I-J..:;b=--o_o_S_·'_f_.~--:-Dimensions :;t{;, )(. '3. \ e. Number of stories? _____"a.._._______ f. Fireplaces or Wooostoves __ Number of eachMethod of heating?' .p,0ftt"e: lfocc.f?J.. c\.\ ( O~··~·_·_ g. Energy:CbA~rvatiori Compliance. -'f-f.-€:!=:'::.:.s=-~____Masscheck Energy Compliance form attached? ..,--_____ h. TypeOf,.COristruction' ~W i. Is construction within 100·ft. of wetlands? ___ Yes L No. Is construCtion within 100 yr. floodplain LYes__No j. Depth of basement or cellar floor below finished grade __=5::::::..,.·_+'_,....;,.._-'-___ k. .Will buiidirl~,conform to the Building and Zoning regulations? ><. Yes No . I. Septic Tank~ City Sewer Private. well_~_ City water Supply ~ .. /, .)e~·P~O~ar " , . as Owner of the subject property (') l\ ,-,. ~ . \ . JI hereby authorize rY' ... eo ,:::.v'\\cle..rs yY\,\ce.. -::So\,\\,,\ '. to act on my behalf, in aU matters relative to work authorized by this building permit application. " ~ )~. .. b I, , as Owner/Authorized Agent ~ereby declare that e statements and information on the foregoing application are true and accurate, to the best of my knowledge and bellet .'. .' . ... Not Applicable 0 GSC\lb~~ B.1 Licensed Construction Supervisor: . ~~~,~~~~~~\~~~-~)~o~~~__~__ '23 .~,\\;~ ~ ~~ Company Name Registration Number , Expiration Date '\I\IArU'~r~' Compensa'tionJrisurance affidavit must be completed and stibmittedwith this application. Failure to provide this affidavit will result ofthe issuance of the The current exemption for "homeowners" was. extended to include Owner-occupied Dwellings ofone (1) or two(2) families and to allow such homeowner to engage an individual for hire who does not possess a license, provided that the owner acts as supervisor. CMR 7S0, Sixth Edition Section 108.3;5.1. , , Definition ofHomeowner: Person (s) who own a parcel ofland on whlchhe/she resides or intends to reside:wn which there is, or is intended to be, a one or two family dwelling, attached or detached structures accessory to such use and/ or farm structures. A person who constructs more than one home in'a two~year period shall not be considered a homeowner. Such "homeowner"-shaIIsubmit"tcr the Building Officia1;on a form acceptable to the Building Official, that he/she shall be 'responsible for all such work performed under the building permit. As acting Construction SuperYisor your presence on the job site will be required from time to time, during and upon completion ofthe work for which this permitis issued. Also be'adVised that With,referencetoChapter.r52~(WcirkerS' Compensation) and Chapter 153 (Liability ofEmployers to Employees for ~juries not resulting in Death) ofthe Massachusetts General Laws Annotated, you may be liable for person( s) you hire to perform: work for yoliundeilliis p-einiit. , The undersigned "homeowner" certifies and assumes responsib~ityJor c:9mPliap,ce with .the State Building Code, City of , Northampton Ordinances, State and Local Zoning Laws and State ofMassachusetts General LaWs Annotatoo. Homeowner Signature _________~_______~________ (fliHClJHt -""" rmlslltlf~1.mt RIGHT I n.., ' """"" i I'HIlSUE;OI"l.!lCRI./I'ft UlLtfli Ullt-""'" [I) t_~j! II ! 1+ ::ru::: tt Y------Jii:11 '"'-'/4WM..""'tn,,, III ELEVATION '\...:!':.;.:~"II ~ 1m g LEFT ELEVATION REAR ELEVATION ENERGY STAR !lllIE; DUE TO MOtsroRE CONYEr« Of WOOO, SOME SHRINKAGt MAY OCCUR IN rHE FACt MOTH OF THE lUMBER OUE TO /tAJUAA, tuijBER 5~INC PROCESS AND WAY EmCT me TH1S IlRAWING IS THE PRQP£,fm' Of' S'Nfit.E)( AND IS ~£t) UPON COHOOlON: TIiAT If IS NOT TO B£ REPROOUCEO OR COPIED IN WHOLE: OR IN PART, OR USEO FOR f'URMSHINGOOERlOR FINISH A?PtJCA1!ON. EXI'ERlOR F1«l5H lNSl'iUfR SHOUlD CONSULT THt: EXfERlOR flWSH t.lAlERW" J.IANIJFACTIJRER FOR RECOOUENom INSI'AI.I.JiIlOK TO ACCOIJNT FOR INfOFWAilON TO OTHERS, OR fOR ~OtHER PURf'O'SE IlETRII.IEHTAl TO THE tnrEREsr Of 'SNfIUX N'lO WILL SE RETURNEO UPON REOum TO $Jt.IPLEX INIIDSTRIES, INC. BELMONT IIMODi::L:BUILDi::R: M E JOHN BUILDERS CUSTOMER: OBER 26'-0" )( 31'-0" fng H: 12-1104 Seriol i; Oate: 12-4-12 Checki):d~: Pags: '\ Rev. Pote: BUILDING ELEVATIONS POSSI3l£ WOOD SHRfN!<ACE, 11'-11/" ,'·3 a/ll' DINING ROOM BEDROOM #1 1ff4 SiZ£fJUf. LIVING ROOM BEDROOM H2 Qfpl t'_l' PRELIMINARY FOR INFORMATION ONLY NOT FOR CONSTRUCTION ENERGY STAR 11'-101/t:' J'-.I/t' Jj'-¢ ---'l. GENERAL NOTES: S'.(J" CEILING HEIGHT PEl( WATER LINES UI'-1 1 ....~ M TOTAL REQUIRED HOUSE 6TUH'li: T6D BUILDER INFORMATION: 1. IT IS THE BUIlDER'S RESI'ONSIBIUTY TO INFORM SlMl'LEX INDUSTRIES, lNC. OF ANY LOCAL COOE Issues OR SITE RELATED REQUIREMENTS THAT MAY AFFECT THE STRUCTURAL INTEGRITY OF THE MODULES TO BE I:RECTEO ON THE SITE. 2. FLOOR PLAN CHANGES MAY BE REQUIRED PE:N01NG FURTHER STRUOTURAL AND CODe REVIEW. 3. (IOOITIONAl. E:NGINEERING FEES NOT INCLUDro IN THE ORIGINAL QUOTE MAY BE REQUIRED TO BE CHARGED FOR PENDING FURTHER STRUCTURAL AND CODE REVIEW. ADDITIONAL ENGINEDfNG FEES NOT INCLUDED IN 'fHEORJG1NA\. QUOTE MAY BE REQUIRED TO BE CHARGED FOR PENDING FUR.THER STRUCTUIW..AHD CODE. 1itEVJ!W 31'-1)' (*) "" GENERAL NOTes. 1, I'1'I:US N01'tD MoTH A 51H$lE AS1'iRISK (') $KW.. iE fllUl'vlOED 8'r SINP'IJ!lt. SMIPPSD ~Me tflfALI.fO CIJRli.Ia THt strr BY W car¥t AT THE: Jpasrre;.PER l.OCAL.coocs:. (**) ~:m~:r~.~%~~.JSHW. f$TAU.£O f1( THt SUll,..l)ER JiJ THt ..lOS SITE. PDt loe.. COO<S. (***) ~=o:~w,:.~~~*tr5K'U. 1HE JOB SfIt. PER LOCAl. COOES. (****)~~~~~Kec;;.\~aE JOe SI1£. P£R I.OCIL CODES. !. tw?TiOHS J\S SHOWN HR loW( WRi' AHO/OA S£ ~Of CONSTR!JCfJON QHLY. IH ALL eASES mEA RI HOUSE: ORO'£A Am) f1.OOR P!.Ni(S} F'OR AC'IlJ"," QUANmY NiO L.OCA1iOII1 OF' IlOOA{s) AAIO WlHDOWS. me IoCTUAl. WlI1iH AHD lO4GTH Of' HOWE. ml!IlWE: TO MOI'ST\JRt CONTENl' OF waco, $OUE SHRiNKAGE W\Y OCCUR IN ruE FiI.C£ WIDTH OF TilE LUt.I$EA DUE TO NATURAL LUMBER SEASOK~ PROCESS AM MAV EFfECT TIt THIS O~WlNG lS THE PR(IPERl"f of S1I.IPI.EX ANI) IS ~EU t1P()N CONOITlON THAT IT IS NOT Tt) 9E REPRODUCED OR COPIED IN vrHOt£ OR iN FiW, OR USED FOR fURNISHING EXTERIOR FINlSH APPUCATlON. EXlIRiOR FlNlSH INSTM.!.ER SHOULD CON5IJlT ruE EXTERIOR FINISH iJATERW,. UAHUFACiURER FOR R£COt,IMEtIDfD INSTAUAflON TO AttoVNT fOR JNFOIWAnON TO oniEllS, OR FOR ANY OTHER PIffiPQS£ OCTRIIJOOIL TO 00: INTER£Sf OF SlUPlEX AND WIlL BE ROURNED tJfION REOU(ST TO 9.JPi..EX INOUSTRlES, INC, 1 POSSlBlE WOOD SHRINKAC'E. M E JOHN BUILDERS CUSTOME:R: OBER8U1LDE:R: Moca: BELMONT II 26'-0" X 3i'-O~ Orown By: JCH Scale: 1/4":= 1'-0"1ST FLOOR PLAN Dote~ 12-4-12 IChecked By! Poge; 2 IRey, Cote: I Jll)lE; iH£ MOPERN or SIMPLEX ANOOUI:: 1'0 j(OlSTURE CQNT£NT O'F' 'WOOD, SOME SHRINKAGE WtY OCCUR IN THE rACE WIDTH OF mE LUUE£R 00£ TO IiAIURAL WMeER SEASONING pROC£SS AND NAY EmCT THE TO OlliER$. OR FOR AHY OTHER POSSIBlE woon ~E. EXTERtOR FINISH AFPUCAnoN. 0J'i:Rl0ft FINISH INSTNlER SHOUUl CONSULT THE EXTERIOR flHrs» lW'ERW. \WM'AC1\1R£R fOR RECOIDJENDro w.lSTAU.AIlOO TO ACCOUNT FCfl CUSTOMER:BUILDER: M E JOHN BUILDERS Scole: 1/4" 1'-0" Date: 12-4-i2SUGGESTED FOUNDATION PLAN Poge: 1~ I.,J"IIIII'IW yrVl'l \",,/I'U,IIIVI'< 1I''l/0l1 II 1:;:0 I'!VI t:!Imrli"ll:e I'V:nHutruTA. Tf\ TLI .. ''''''''C=''' ..... OBER Drown By: JCH BELMONT II 26'-0" X JI'-O~ l!llli:: 8ASE"ENT sr~R OPa<ING IS DEsiGNED TO CATER TO A a 1/4· x 9" STAlR. PRELIMINARY FOR INFORMATION ONLY NOT FOR CONSTRUCTION tm.ItI M:~TKliDESlI:N.~BASEDON,l,S$UWmsoo.~ CAPlIOrt iIlO IS' ~l' SUGCE!tli!) AND SHAU. NOr BE l.lS£il fOR Em:VIIOIi KRlUf«)IJlOH:OESlIli sw.u..m 8Ewm~ sm:SP£C1FlC SOII.~ATm£l!ICAnoNSll£,.TH£~SlW..L9E O£SIGlitO sY A lJ('l)jSED ENGlttm! OR AACIoIrm:T T ft(QUlRm liT RI:1itJlMIONS or M PN'lnQPAM:: SfAlE 1M WHICH 1)1£ I'ltlk.DING IS ~roaELOCAT£O. JI'-.(I' ~fOQl'fC$I1UImttJl:t'HtlFaD ~ ~ ~=-rJ:~~NIII s PERiCIO~("'l~m>. ~ ~-111t' ;a~I'fl«Al_~S R!V SIJUlm g;D£5 \"") ~ nI"" ,.~, Itt <4 M6-~~~ U!CII.woou:mlMlOOUlNl <.COeS.{4~1'I'mt 5·~2· ..•ft't\1lllN ./!N$ffCll91l'ltPN,"_ (CPL) OE'!IOIESACOI.tIIII~~ 5tlWO!iT" CRlnCAl,. PQM'ctl..UNIfS \lAY Hor II~ ~til.rnDI!fNNI.W!IIEl1, Flood Volume Calc 23 Fair St 26 Height below BFE 10" wall Proposed Foundation existing house Main addition total below BFE volume below bfe Existing Structure Proposed Structure Change If 31 2 114 If 4 456 sf area 0.833 cf per sf 379.848 14.06844 Cu yds foundation 572 sf 192 sf 764 sf 4 113.1852 cu yds 113 cu yds 14 cu yds -99 cu yds File # MP-2013-0067 APPLICANT/CONTACT PERSON OBER JEREMY D ADDRESSIPHONE 8 HOCKANUM RD #14 (413) 658-7583 () PROPERTY LOCATION 23 FAIR ST MAP 25C PARCEL 255 001 ZONE SC(lOO)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Building Pennit Filled out ;:r;;Jo ifp=t Fee Paid T:meofConstruction: ZPA -DEMO HOUSE New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/ Statement or License 3 sets of Plans / Plot Plan THE FOLLOWlNG:tECON HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFORMATION P ENTED: __Approved Additional permits required (see below) PLANNING BOARD PERMIT REQUIRED UNDER: § ________ Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: s__________ Finding,____ Special Permit _____ Variance* -----­ ___"Received & Recorded at Registry ofDeeds ProofEnclosed'--____ ___Other Permits Required: ___CUrb Cut from DPW ___Water Availability ____Sewer Availability ___Septic Approval Board ofHealth ____Well Water Potability Board of Health ___Permit from Conservation Commission Pennit from CB Architecture Committee --Yermit from E~Street Commission Permit DPW Storm Water Management ~. Hlsro(l...\<:j\ 0 ~ J I Signature ofBuilding Official· _ COMAlHS8(d JJ A 4?­ ...... - 'DtAM Date D€d,.Jt1 I/Y/r3 I I Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health, Conservation Commission, Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards ofMGL 40A. Contact the Office of Planning & Development for more information. 'jO ~--~0I3.- .Jl?P-/3-t:,7 NORTHAMPtoN. APPLICATION(§10.2 Please type or print all information and return this form to the Building Inspector's Office with the $ls.filingfee (check or money order)payable to the City ofNorthampton 1. Name of Applicant: -::S-ere..~~ D. 0 b lLr Address: ~S £C\.\{" ~\ TeLephone: ':\ \ 3:. -(0 S ~-,S 8..3 2. Owner of Property: SClVV\.~ Address: "6 l\-a::,~\I\v"'" Lot ~. \Y tvoc\-~~-.pTelephone:101\ 4 \ 3. ... "S~-"J.SC 3. Status of Applicant: Owner '6 Contract Purchaser Lessee Other (expLain)_____ 4. Job Location: #'3, ~r Sot I\rO("+Mvv--p1Or) (V'..-Ct Parcelld: Zoning Map# ~S C Parcell AS.) District(s):_.l..QO.JJlttl,...J\~____ In Elm Street District In Central Business District, ____ '0 BE FILLED IN BY THE BUILDING DEPARTMENT) 5. Existing Use of Structure/Property: Re $'\o..e."'(f I q bC\.....J.orJ I 6. Description of Proposed Use/Work/Project/Occupation: (Use additionaL sheets if necessary): o -€-vv---e\'):10V\ at ~"l(Sl)¥\~ hous.e 7. Attached Plans: Sketch Plan Site Plan Engineered/Surveyed Plans ~~ 8. Has a Special PermitlVariance/Finding ever been issued for/on the site? NO_4---_ DONT KNOW ____ YES ____ IF YES, date issued: ________ IF YES: Was the permit recorded at the Registry of Deeds? NO DONT KNOW ____ YES ___ 1<­ IF YES: enter Book _____ Page and/or Document # _______ 9.Does the site contain a brook, body of water or wetlands? NO Y. DONT KNOW ___ YES __ If' YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained _____ Obtained , date ,;);)u""u. __________ (Form Continues On Other Side) 8/4/2004W:\J)ocuments\FORMS\origina\\Butlding-Inspecto!\Zoning-Permit-App\icljiipn-passive,doc y:.10. Do any signs exist on the property? YES ____ NO IF YES, describe size, type and location:___________________________ Are there any proposed changes to or additions of signs intended for the property? YES NO~ IF YES, describe size, type and location:___________________________ 11. Will the construction activity disturb (clearing, grading, excavation, or filling) 0;t1 acre or is it part of a common plan of development that will disturb over 1 acre? YES__ NO IF YES, then a Northampton Storm Water Management Permit from the DPW is required. 12. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION This column reserved for use by the Building -y_.......".._........ EXISTING PROPOSED REQUIRED BY ZONING Lot Size lo,50 () JO 1)0 b Frontage bO' roo r Setbacks Front Side Rear L: , r\S R: '7 II'" f , IIIL: \ S R: , \ L," L: R: Building Height SO{ 3~1 Building Square Footage ')J-3<G \1 &,00 % Open Space: (lot area minus building &. paved parking 90% 90% # of Parking Spaces l-{ ~ # of Loading Docks 0 0 Fill: . (volume &. location) a -0 13. Certification: I hereby certify that the information contained herein is true and accurate to the best of my knowledge. Date: \ J~JI ') Applicant's Signature ~w =:J D·~ NOTE: Issuance ofa zoning permit does not relieve aft applicant's burden to comply with all zoning requirements and obtain all required permits from the Board ofHealth, Conservation Commission, Historic and Architectural Boards, Department ofPublic Works and other applicable permitgranting authorities. 8/4/2004W:\Documents\FORMS\original\Building-Inspector\Zoning-Perrnit-Application-passive.doc