Loading...
Smith Presidents House - CONSTRUCTION SET 2016-03-100.0 Title Page A-1.0 BASEMENT PLAN A-1.1 1ST FLOOR PLAN A-1.2 2ND AND 3RD FLOOR PLANS A-2.0 NORTH & WEST ELEVATIONS A-2.1 SOUTH & EAST ELEVATIONS A-5.0 WINDOW SCHEDULE A-5.1 WINDOW SCHEDULE & ELEVATIONS A-5.2 DOOR SCHEDULE & ELEVATIONS PRESIDENT'S HOUSE, SMITH COLLEGE WINDOW & DOOR REPLACMENT NORTHAMPTON, MA Smith College 126 West St. Northampton, MA 01063 Morgan Wilson, Project Manager, Capital Projects mtwilson@smith.edu (413) 585-2447 (516) 209-1751 - cell Kraus Fitch Architects, Inc. 110 Pulpit Hill Road Amherst, MA 01002 (413) 549-5799 Laura Fitch, AIA, LEED BD-C 413-687-2727 (cell) lfitch@krausfitch.com KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 Title Page 0.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 Title Page 0.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET ELM STR E E T / RO U T E 9 PARADISE ROADCOLLEGE LANE   FENCED UTILITY COURT  FLAT PATIO AREA STUDENT PERMIT PARKING ALONG PARADISE ROAD GARDEN HEDGESTEEP SLOPE RETAINING WALLGARDEN FENCEFEN C E FEN C E FENCESTE E P HIL L S I D E W/ SH R U B S POSSIBLE STAGING AREA FOR CONTRACTOR STORAGE "BOX" AND PORTA-POTTY PARKING FOR LIFT SITE PLAN NO SCALE 2 0.0 ELM STRE E T / ROU T E 9 PARADISE ROAD COLLEGE LANE   LOCUS MAP NO SCALE 1 0.0 GENERAL CODE SUMMARY: IEBC: Work Area Compliance Method: Level 1 (window and door replacement) Size of Building Footprint with Porches (exterior): 5,239 SF Total Finish Interior Square footage (not including basement): 10,045 SF Uses Use Group R-3 (Residential Single Family) Safety Glazing (IBC 2009) Required in the following locations: - Glazing adjacent to doors (within 24")- in locations as noted in schedule - Low panels (within 18" of floor) - NOT APPLICABLE - Stairways and landings (< 60 inch to sill)- NOT APPLICABLE Window Sill Requirements (IRC 2009) In dwelling units where the opening of an operable window is located more than 72 inches above the finished grade or surface below, the lowest part of the clear opening of the window shall be a minimum of 24 inches above the finished floor of the room in which the window is located. Operable sections of windows shall not permit openings that allow passage of a 4 inch diameter sphere where such openings are located within 24 inches of the finished floor. - NOT APPLICABLE Emergency Window Egress Requirements Not applicable for window replacement. Stretch Energy Code Requirements Residential Requirements - Windows: 0.30 max u-value - 1/2 lites Doors: 0.27 max u-value - Full lite Doors: 0.32 max u-value Commercial Requirements (for energy rebate calucations as building is heated from central plant). - Windows: 0.35 max u-value - 1/2 and full lites Doors: 0.45 max u-value Codes and Other Sources 2009 International Building Code (IBC) 2009 International Residential Code (IRC) 2012 International Energy Conservation Code (IECC) Massachusetts Amendments to the IRC 2009 Massachusetts Stretch Energy Code A-3.0 A-3.0P A-3.1 A-3.1P A-3.2 A-3.2P A-3.3 A-3.4 A-3.5 TYP. EXISTING EXISTING CONDITIONS DOUBLE HUNG EXISTING CONDITIONS SPLAYED DH FIRST AND SECOND FLOOR PROPOSED SPLAYED DH FIRST AND SECOND FLOOR EXISTING CONDITIONS BOWED BAY FIRST FLOOR PROPOSED BOWED BAY FIRST FLOOR NEW DH AT IN-SWING CASEMENTS (EXTG AND PROPOSED) NEW DH AT OUT-SWING CASEMENTS (EXTG AND PROPOSED) PROPOSED TYPICAL SINGLE HUNG: MARVIN & KOLBE A-3.6 A-3.7 A-4.0 A-4.1 A-4.2 A-5.0 A-5.1 A-5.2 ATTIC WINDOWS DOORS: LOGGIA AND STAIR DOORS: SECOND FLOOR ARCHED DOORS: SECOND FLOOR WINDOW SCHEDULE WINDOW SCHEDULE AND WINDOW TYPE ELEVATIONS BAY WINDOW SECOND FLOOR (EXISTING AND PROPOSED) DOOR SCHEDULE AND DOOR ELEVATIONS DOUBLE WINDOW AT 2ND FLOOR (EXISTING AND PROPOSED) A-3.8 A-3.9 NEW DH WINDOWS AT LIBRARY BALCONY DOORS NEW CASEMENT WDWS AT LAUNDRY ROOM DOORS A-3.10 BASEMENT WINDOWS A-3.11 GARAGE WINDOWS A-3.12 GARDENER'S WINDOWS KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 BASEMENT PLAN A-1.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 BASEMENT PLAN A-1.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET GARDENER'S ROOM 003A 002A 004 HOT WATER TANK ROOM 002 UP 005 UP 008 007 STORAGE AREA LAUNDRY ROOM 003 ELEV EXISTING APPROXIMATE AREA OF UTILITY / MAINTENANCE YARD REPLACE EXISTING DOOR WITH NEW WINDOW, PANEL BELOW (INSIDE AND OUTSIDE) BY SITE CONTRACTOR REPLACE EXISTING DOOR WITH NEW WINDOW, PANEL BELOW (INSIDE AND OUTSIDE) BY SITE CONTRACTOR REPLACE EXISTING DOOR WITH NEW WINDOW, PANEL BELOW (INSIDE AND OUTSIDE) BY SITE CONTRACTOR REPLACE EXISTING "Y" WINDOWS WITH MAPES PANELS ADD 1-1 WINE CELLAR HAS INSULATED SOFFIT THAT COVERS WINDOW. REMOVE AND REINSTALL AS NEEDED. ADD 1-1 CUT MAPES PANEL AS NEEDED TO ACCOMMODATE EXISTING PIPE. REPLUMB AS NEEDED. SEAL PENETRATION. ADD 1-1 PROTECT IT EQUIPMENT AND PANELS BELOW AND IN FRONT OF WINDOWS     ADD 2-10 (MODIFIED BY ADD 3-8): UTILIZE EXISTING SCREEN DOOR ADD 3-8 BASEMENT PLAN Scale: 1/8" = 1'-0" 1 A-1.0 KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 1ST FLOOR PLAN A-1.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 1ST FLOOR PLAN A-1.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET BUTLERS PANTRY WASH ROOM GARAGE 106 KITCHEN PORCH RANGE REFRIG 105 GUEST ROOM 110 111 BATH BREAKFAST PORCH DN DN UP UP 104 OFFICE 103 102A 101 ROOM 112 DINING RECEPTION 102 HALL LOGGIA ELEV UP 114 113 ROOM LIVING RADIATOR COVER RADIATOR COVER PREVIOUS REPLACEMENT WDW. - INCLUDED IN CONTRACT FRONT DOOR NIC DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS WOOD AND S.S. BACKSPLASH IN FRONT ON WDW. CORIAN BACKSPLASH IN FRONT ON WDW. CORIAN BACKSPLASH IN FRONT ON WDW. LOWER SASH INTERIOR SHUTTERS SUNROOM DOORS NIC WITH 20" TRANSOM PANEL SUNROOM DOORS NIC APPROXIMATE AREA OF UTILITY/ MAINTENANCE YARD AT BASEMENT LEVEL BELOW REPLACE DOORS AND SCREENS DOORSREPLACE EXISTING FRENCH CASEMENT WINDOWS WITH NEW SINGLE HUNG UNITS KITCHEN DOOR AND SCREEN - NIC FIRST FLOOR PLAN Scale: 1/8" = 1'-0" 1 A-1.1 KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 2ND AND 3RD FLOOR PLANS A-1.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 2ND AND 3RD FLOOR PLANS A-1.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET DN DN UPUP DN OPEN TO BELOW ROOF DECK Washer Dryer LIBRARY 208 SITTING ROOM 207 GUEST BEDROOM 209 Kitchenette/Laundry 212 GUEST BEDROOM 206 PRIVATE STUDY 205 MASTER BEDROOM 201 MASTER BATHROOM 203204 202 ELEV 215HALLWAY 210 211 GUEST BEDROOM 214213 INTEGRAL RADIATOR COVER DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS AND RADIATOR DOUBLE INTERIOR SHUTTERS DOUBLE INTERIOR SHUTTERS INTEGRAL BOOK CASE INTERIOR SHUTTERS AT BOTTOM SASH INTERIOR SHUTTERS AT BOTTOM SASH RADIATOR COVER, BELOW SILL RADIATOR COVER, BELOW SILL 22" DEEP BALCONY EXISTING STORM SCREEN COMBO EXISTING STORM SCREEN COMBO EXISTING STORM SCREEN COMBO EXISTING STORM SCREEN COMBO 32" HIGH RAD. BETWEEN UNITS GUTTER CONFLICT AT THIS WINDOW, (REMOVE GUTTER AND ADJUST AS NEEDED IF FACTORY-APPLIED CASINGS) REPLACE EXISTING DOORS WITH NEW DH WINDOWS, PANEL BELOW (INSIDE AND OUTSIDE) BY SITE CONTRACTOR REPLACE EXISTING FRENCH CASEMENT WINDOWS WITH NEW SINGLE HUNG UNITS REPLACE EXISTING CENTER FRENCH CASEMENT WINDOWS WITH NEW FIXED PICTURE UNITSREVERSE SWING OF NEW DOORS AND ADD NEW SLIDING SCREEN DOORS. RAISE SILL 1". REPAIR FLASHINGS. 2 STEPS UP TO DOOR REMOVE EXISTING NARROW BALCONY, REPAIR STUCCO. ADD 1-2 NEW SWINGING SCREEN DOOR ADD 1-2 TEMPERED GLASS PER SCHEDULE SECOND FLOOR PLAN Scale: 1/8" = 1'-0" 1 A-1.2 303 STORAGE 302 BATHROOM 305 301 3'-4" TYPL DORMER 2'-6"REMOVE EXISTING STORM SCREEN COMBO ALL ATTIC WINDOWS EXISTING SKYLIGHT TO BE REMOVED IN SEPARATE CONTRACT THIRD FLOOR PLAN Scale: 1/8" = 1'-0" 2 A-1.2 KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 NORTH & WEST ELEVATIONS A-2.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 NORTH & WEST ELEVATIONS A-2.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET NIC INTERIOR LINE OF WALK TO FRONT DOOR, IN FRONT OF BUILDINGHALLWAY DASHED LINE OF GARAGE, IN FRONT REPLACE ARCHED DOOR WITH SIMILAR DOOR WITH LARGER LITE. NEW FRAMES WITH MAPES PANELS IN THREE (3) BASEMENT WINDOWS REPLACE INSWING AWNING WITH SLIDING FIBERGLASS UNITS, TYP. REPLACE ALL SHUTTERS. REMOVE ALL EXISTING PLATE PINTELS, HINGES AND S-HOLDBACKS, AND REPLACE WITH NEW PORCH BEHIND GARAGE KITCHEN DOOR N.I.C. NIC NORTH ELEVATION - PROPOSED Scale: 1/8" = 1'-0" 1 A-2.0 DASHED LINE OF GARAGE, IN FRONT REPLACE ARCHED DOOR WITH SIMILAR DOOR WITH LARGER LITE. STONE STUCCO REPLACE DOOR WITH WINDOW AND PANEL NORTH GARAGE ELEVATION - PROPOSED Scale: 1/8" = 1'-0" 2 A-2.0 NIC REPLACE INSWING AWNING WITH SLIDING FIBERGLASS UNITS, TYP. REPLACE ALL SHUTTERS. REMOVE ALL PLATE PINTELS, HINGES AND S-HOLDBACKS, AND REPLACE WITH NEW WEST ELEVATION - PROPOSED Scale: 1/8" = 1'-0" 3 A-2.0 REPLACE FRENCH CASEMENT @ MASTER BEDROOM WITH DH WINDOW REPLACE FRENCH CASEMENT@ GUEST BEDROOM 206 WITH DH WINDOW REPLACE FRENCH CASEMENT @ MASTER BEDROOM WITH DH WINDOW REPLACE FRENCH CASEMENT@ GUEST BEDROOM 206 WITH DH WINDOW REPLACE FRENCH CASEMENT @ MASTER BEDROOM WITH DH WINDOW REPLACE FRENCH CASEMENT@ GUEST BEDROOM 206 WITH DH WINDOW REPLACE FRENCH CASEMENT @ MASTER BEDROOM WITH DH WINDOW REPLACE FRENCH CASEMENT@ GUEST BEDROOM 206 WITH DH WINDOW WEST AND EAST ELEVATIONS INSIDE LOGGIA - PROPOSED Scale: 1/8" = 1'-0" 4 A-2.0 KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 SOUTH & EAST ELEVATIONS A-2.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 SOUTH & EAST ELEVATIONS A-2.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET BREAKFAST PORCH NIC DEMO LIBRARY BALCONY, REPAIR SURFACE AS NEEDED REPLACE FRENCH CASEMENT @ MASTER BEDROOM WITH DH WINDOW REPLACE DOOR & SIDELIGHTS @ LAUNDRY WITH FRENCH CASEMENT AND PANEL BELOW REPLACE FRENCH CASEMENTS @ FIRST FLOOR GUEST ROOM WITH DH WINDOWS REPLACE WINDOWS, TEMPERED GLASSFIELD APPLIED "CAPITALS" AND BASES TO SIMULATE REMOVED CASINGS REPLACE CENTER FRENCH CASEMENT @ MASTER BEDROOM AND GUEST BEDROOM 206 WITH SINGLE FIXED WINDOW, MUNTIN SPACING TO MATCH DH WINDOWS AT SIDES REPLACE DOORS @ LIBRARY WITH DH WINDOWS AND PANELS ADD FLASHINGS AT BASE OF EXTERIOR PANELS, SEE   REPAIR FLASHING AT DOOR THRESHOLD/BALCONY INTERFACE SOUTH ELEVATION - PROPOSED Scale: 1/8" = 1'-0" 1 A-2.1 NIC REPLACE DOOR & SIDELIGHTS @ LAUNDRY WITH FRENCH CASEMENT AND PANEL BELOW STUCCO STONE REMOVE S-HOLDS FROM PREVIOUS SHUTTERS; TOUCH UP STUCCO & FINISH AS NEEDED SOUTH ELEVATION - PROPOSED Scale: 1/8" = 1'-0" 2 A-2.1 SASH POCKET APPROX. 4 1/8" BRICK OR STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING EXISTING FRAME EXISTING JAMB EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) PAINTED WOOD SASH INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED 2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP. SOME WINDOWS HAVE EXISTING STORM/SCREEN COMBINATION UNITS MOUNTED ON EXTERIOR. PROPABLE CONDITIONS AT COUNTER WEIGHTS: SEPARATED BY ZINC METAL STRIP. NOTE: HEADS HAVE SIMILAR VOIDS WITH NO WEIGHTS. LINE OF PLASTER 4 1/2" +/-10 1/2" +/- SILL1'-9" +/- RADIATOR COVER5" +/-3 1/4" +/-1 7/8" +/- INTERIOR SHUTTERS IN SOME LOCATIONS    EXISTING JAMB (HEAD SIMILAR) Scale: 3" = 1'-0" EX-4 A-3.0 TYPICAL EXISTING WINDOW UNIT WITH INTERIOR CASING REMOVED SASH WEIGHT SASH CORD VOID ROUGH OPENING GAP (1/4" - 1/2") SASH SILL     SASH WEIGHT SHEET METAL SEPARATOR ROUGH OPENING GAP 1" THICK JAMB 3/4" FRAME VOID 1" EXTERIOR CASING 1" INTERIOR CASING PARTING STRIP SASH FACE OF BRICK MASONRY SASH STOP JAMB DETAIL: TYPICAL EXISTING WINDOW UNIT    TYPICAL EXISTING CONDITIONS - DOUBLE HUNG UNITS SASH POCKET APPROX. 4 1/8" INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED SLOPED, PAINTED WOOD SILL EXTERIOR CASING & SASH STOP EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) EXISTING PARTING STRIP 3" +/-2 1/2" +/-10 1/2" +/- SILL 1'-9" +/- RADIATOR COVER 1 3/8" +/-EXISTING SILL Scale: 3" = 1'-0" EX-3 A-3.0 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 TYP. EXISTING CONDITIONS DOUBLE HUNG A-3.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 TYP. EXISTING CONDITIONS DOUBLE HUNG A-3.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 KOLBE - ULTRA SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 PROP. TYP. SH KOLBE A-3.0P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 PROP. TYP. SH KOLBE A-3.0P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 TYPICAL SINGLE HUNG WINDOW GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 16. INTERIOR SHUTTERS 3/16" 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 2. PREVIOUS WEIGHT POCKET   9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3"+/- 13. CAULK JOINT 8. PEEL & STICK 17. BLINDS 1/2"1 1/2"2" 15. INSTALL SHUTTERS STRAP HINGES TO BE LOCATED SO THATWINDOW OVERLAPS M.O. AS SHOWN, SHUTTER WILL NOT BE OPERABLE 1/2" OVERLAP @ MASONRY OPENING PROPOSED JAMB (HEAD SIMILAR) Scale: 3" = 1'-0" 2-K A-3.0P 4" +/-    4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL 8. PEEL & STICK PROPOSED SILL Scale: 3" = 1'-0" 1-K A-3.0P 16. INTERIOR SHUTTERS 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 2. PREVIOUS WEIGHT POCKET   9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3/16" 3" +/- 13. CAULK JOINT 8. PEEL & STICK 17. BLINDS 1/2"1 1/2"2" 15. INSTALL SHUTTERS STRAP HINGES TO BE LOCATED SO THATWINDOW OVERLAPS M.O. AS SHOWN, SHUTTER WILL NOT BE OPERABLE 1/2" OVERLAP @ MASONRY OPENING PROPOSED JAMB (HEAD SIMILAR) Scale: 3" = 1'-0" 2-M A-3.0P 4 1/8" +/-    4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL 8. PEEL & STICK PROPOSED SILL Scale: 3" = 1'-0" 1-M A-3.0P MARVIN- NEXT GEN. FULL FRAME SASH POCKET APPROX. 4 1/8" TYPE I - FIRST FLOOR SPLAYED STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING EXISTING FRAME EXISTING JAMB EXISTING STOP: 1/2" X 2" (SCREW ATTACHED) PAINTED WOOD SASH INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED 2 1/4" +/-2 1/4" +/-2" +/-1 1/2" +/-EXTERIOR STOP PROPABLE CONDITIONS AT COUNTER WEIGHTS: SEPARATED BY ZINC METAL STRIP. NOTE: HEADS HAVE SIMILAR VOIDS WITH NO WEIGHTS. LINE OF PLASTER 1 1/4" +/-1'-4 3/4" +/- RECESS / RADIATOR COVER2'-9" +/- STOP TO STOP DIM SECOND FLOOR 3'-1" +/- FIRST FLOOR TO POINT OF TEAR BA 4'-0" +/- FULL SPLAYED OPENING SECOND FLOOR SHUTTER PIN - SOME UNITS 3'-9 1/4" +/- MASONRY OPENING FIRST AND SECOND FLOORS EXISTING CONDITIONS: JAMB Scale: 3" = 1'-0" EX-2 A-3.1 SASH POCKET APPROX. 4 1/8" SPLAYED SIDE WALLS, BEYOND INTERIOR WOOD SILL, PAINTEDSLOPED, PAINTED WOOD SILL EXTERIOR CASING & SASH STOP EXISTING PARTING STRIP FIELD DETERMINE 3" +/-10 1/2" +/- SILL EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) RADIATOR COVER EXISTING CONDITIONS: SILL @ RADIATOR COVER Scale: 3" = 1'-0" EX-1A A-3.17'-2" +/- MASONRY OPENINGFIRST FLOOR2 1/4" +/-2 1/4" +/-6'-8"+/- TRIMMED OPENING FIRST FLOOR1 1/2" +/-5'-4 1/2"+/- TRIMMED OPENING SECOND FLOOR5'-10" ?????? +/- MASONRY OPENINGFIRST FLOOREXISTING CONDITIONS: HEAD Scale: 3" = 1'-0" EX-3 A-3.1 SPLAYED SIDE WALLS, BEYOND INTERIOR WOOD SILL OR STOP, PAINTED10 1/2" +/- SILL PANEL BELOWSASH POCKET APPROX. 4 1/8" EXISTING CONDITIONS: SILL @ PANEL Scale: 3" = 1'-0" EX-1 A-3.1 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 SPLAYED DH FIRST AND SECOND FLOOR A-3.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 SPLAYED DH FIRST AND SECOND FLOOR A-3.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016TYPICAL SPLAYED DOUBLE HUNG WINDOW IN VERY THICK WALLS - 1ST AND SECOND FLOORS SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 PROP. SPLAYED DH FIRST AND SECOND FLOOR A-3.1P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 PROP. SPLAYED DH FIRST AND SECOND FLOOR A-3.1P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 PROPOSED SPLAYED DOUBLE HUNG WINDOW - 1ST AND 2ND FLOORS 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK 2. PREVIOUS WEIGHT POCKET   13. CAULK JOINT 9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3/16" 15. INSTALL SHUTTERS 1/2"1 1/2"2" JAMB Scale: 3" = 1'-0" 4 A-3.1P 9. NEW WINDOW 12. FRAME EXPANDER 7. REFINISH SILL 4. SASH STOP & NEW TRIM 10. SHIM SPACE 6. FOAM CAVITIES 14. EXISTING SILL SILL Scale: 3" = 1'-0" 2 A-3.1P3/16"4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. EXTERIOR CASING: VERIFY DISTANCE TO M.O. IS SIMILAR TO JAMBS AND THAT SAME CASING CAN BE INSTALLED AT 3 SIDES. CUT BACK EXISTING FRAME IF NEEDED TO MAINTAIN UNIFORM CAULK JOINT. 9. NEW WINDOW HEAD Scale: 3" = 1'-0" 3 A-3.1P 14. EXISTING SILL 4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL PANEL BELOW WINDOW SILL Scale: 3" = 1'-0" 1 A-3.1P GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. ADD1-3, ADD2-12 and ADD3-10 14. 15. 16. 17. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. INTERIOR WD. TRIM EXISTING PAINTED SASH STOP 1'-0" +/-2" PAINTED WOOD SASH INTERIOR WOOD TRIM, PAINTED 4" +/ - EXTERIOR WD. TRIM (PILASTER) NOTE: CONDITIONS BEHIND FRAME ARE UNKNOWN NO LONGER OPERABLE HINGED SASH, PAINTED OR SCREWED IN PLACE EXISTING SASHES MAY BE BUTTED, OVERLAPPED, OR COVERED WITH TRIM. INTERIOR WD. TRIM / STOP EXISTING PAINTED STOP PANEL AT SIDES EXISTING CONDITIONS: JAMB AND MULLION Scale: 3" = 1'-0" 1 A-3.2 INTERIOR WOOD SILL, PAINTEDSLOPED, PAINTED WOOD SILL EXTERIOR CASING & SASH STOP 2" +/-1'-5" +/- CURVING RADIATOR COVER / S EXISTING STOP / INTERIOR TRIM RADIATOR COVER +/- WOOD FRAMED WALL UNDER BAY5 1/2" +/- EXISTING CONDITIONS: SILL Scale: 3" = 1'-0" EX-2 A-3.2 INTERIOR WOOD SILL, PAINTED VALANCE FOR CURTAINS 6'-6"+/- TRIMMED OPENING 6'-7" +/- ROUGH OPENINGCEILING EXISTING CONDITIONS: HEAD Scale: 3" = 1'-0" EX-3 A-3.2 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BOWED BAY FIRST FLOOR - EXISTING CONDS. A-3.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BOWED BAY FIRST FLOOR - EXISTING CONDS. A-3.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 EXISTING CONDITIONS (15' TO LEFT FOR COPYING) BRICK SILL BRICK TO GRADE PILASTER BEYOND CURVING WOOD BASE TRIM, PAINTED CURVING WOOD PANEL, PAINTED EXISTING CONDITIONS: PANEL BASE Scale: 3" = 1'-0" EX-1 A-3.2 EXISTING CONDITIONS TYPICAL BOWED BAY - 1ST FLOOR EXISTING CONDITIONS (15' TO LEFT FOR COPYING) CAULK JOINT INSTALL FACETED OR CURVED COPPER FLASHING WITH DRIP EDGE OVER CURVED BRICK SILL COUNTER FLASHING AND INSULATION: - CAREFULLY REMOVE CURVED BASE TRIM AND PANEL STILES. - REMOVE OR CUT PANEL BOARDS BEHIND TO INSTALL COUNTER FLASHING. - WHILE BASE OF WALL IS OPEN, EXAMINE CAVITY AND DETERMINE IF DENSE PACK CELLULOSE CAN BE INSTALLED. - REINSTALL EXISTING PANEL BOARDS. REPLACE ANY ROTTEN PIECES WITH FULLY BACK-PRIMED NEW BOARDS TO MATCH. - SEAL ANY GAPS IN SHEATHING - SCRAPE AND PAINT BASE OF PANEL Scale: 3" = 1'-0" 1 A-3.2P 1'-0" +/-2" 4" +/ - NEW P.T. EXTERIOR STOP WRAP NEW STOP WITH BREAK METAL BACK TO PILASTER, CAULK. 1'-1 0 1/2 " +/- NE W W O O D . CL A D SA S H (N O FR A M E ) APPROXIMATE LINE OF EXISTING CURVED SILL TO BE SCRAPED AND PAINTED. NEW P.T. STUD, CUT TO KEEP NEW BREAK METAL MULL COVER ALIGNED WITH EDGE OF EXTERIOR SILL. SECURE POST WITH PLATE AT SILL AND HEAD. COVER IN PEAL AND STICK. MULL COVER - CONFIRM IF THIS CAN BE CLIPPED INTO SASH NEW P.T. EXTERIOR STOPS WEATHERSEAL EDGE OF SASH WITH SILICONE CAULKING OR NON-EXPANDING FOAM EXISTING TRIM TO REMAIN. REPLACE STOP AT BOTH SIDES. EXISTING TRIM/STOP. CUT AND/OR REPLACE AS NEEDED. REMOVE STOP TO ASSESS CAVITIES BEYOND WRAP EXISTING FRAME WITH PEAL AND STICK EXISTING TRIM/STOP. CUT AND/OR REPLACE AS NEEDED. REMOVE STOP TO ASSESS CAVITIES BEYOND FOAM CAVITIES AS POSSIBLE. FOAM CAVITIES AS POSSIBLE. JAMB AND MULLION Scale: 3" = 1'-0" 4 A-3.2P PEAL AND STICK SMALL TRIM TO BRIDGE BETWEEN EXISTING CASEWORK AND NEW SILL EXISTING WOOD SILL TO BE SCRAPED AND PAINTED FRAME EXPANDER FROM SASH TO SILL NEW SASH INSTALLED JUST ABOVE THE PLANE OF THE SILL P.T. SILL AS NEEDED, CUT TO FIT CURVE OF EXISTING SILL. NEW SASH CAN OVERLAP THE EXISTING INTERIOR SILL (DIFFERENCE BETWEEN NEW STRAIGHT SASH, AND FORMER CURVED SASH) NEW SILICON CAULKING AND NON-EXPANDING FOAM SILL Scale: 3" = 1'-0" 2 A-3.2P PEAL AND STICK SMALL TRIM TO BRIDGE BETWEEN EXISTING CASEWORK AND NEW SILL EXISTING WOOD TRIM TO BE SCRAPED AND PAINTED NEW EXTERIOR STOP WRAPPED IN BREAK METAL NEW SASH INSTALLED JUST UNDER THE PLANE OF THE EXISTING HEAD TRIM NEW SILICON CAULKING AND NON-EXPANDING FOAM P.T. BLOCKING AS NEEDED, CUT TO FIT CURVE OF EXISTING FRAME. NEW SASH CAN OVERLAP THE EXISTING HEAD TRIM (DIFFERENCE BETWEEN NEW STRAIGHT SASH, AND FORMER CURVED SASH) INSTALL NEW HEAD FLASHING HEAD Scale: 3" = 1'-0" 3 A-3.2P SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BOWED BAY FIRST FLOOR - PROPOSED A-3.2P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BOWED BAY FIRST FLOOR - PROPOSED A-3.2P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 TYPICAL BOWED BAY - 1ST FLOOR 6 1/2" +/- INTERIOR WD. TRIM EXTERIOR MULL COVER EXISTING CONDITIONS: JAMB Scale: 3" = 1'-0" EX-3 A-3.3 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DOUBLE WINDOW AT SECOND FLOOR A-3.3 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DOUBLE WINDOW AT SECOND FLOOR A-3.3 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 SASH POCKET APPROX. 4 1/8" BRICK OR STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING EXISTING FRAME EXISTING JAMB EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) PAINTED WOOD SASH INTERIOR WOOD SILL, PAINTED 2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP PROPABLE CONDITIONS AT COUNTER WEIGHTS: SEPARATED BY ZINC METAL STRIP. NOTE: HEADS HAVE SIMILAR VOIDS WITH NO WEIGHTS. LINE OF PLASTERVARIES +/- SILLSHUTTER MOUNTED TO STOP INTERIOR WOOD TRIM, PAINTED 1 7/8" +/-EXISTING CONDITIONS: JAMB Scale: 3" = 1'-0" EX-2 A-3.33/16"3. INTERIOR TRIM 8. PEEL & STICK REMOVE WEIGHTS. CUT OPEN OR DRILL WEIGHT POCKETS FROM EXTERIOR. INSTALL NEW P.T. BLOCKING ONLY IF NEEDED EXTERIOR MULL CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. 3/16" 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 9. NEW WINDOW 16. INTERIOR SHUTTERS JAMB Scale: 3" = 1'-0" 3 A-3.3 14. EXISTING SILL 6. FOAM CAVITIES 4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL 16. INTERIOR SHUTTERS SILL Scale: 3" = 1'-0" 1 A-3.3 3" +/- REMOVE WEIGHTS. CUT OPEN OR DRILL WEIGHT POCKETS FROM EXTERIOR. INSTALL NEW P.T. BLOCKING ONLY IF NEEDED 3/16" 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK 2. PREVIOUS WEIGHT POCKET 6. FOAM CAVITIES 13. CAULK JOINT 9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3" +/- 16. INTERIOR SHUTTERS JAMB Scale: 3" = 1'-0" 2 A-3.3 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BAY WINDOW SECOND FLOOR A-3.4 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BAY WINDOW SECOND FLOOR A-3.4 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 SASH POCKET APPROX. 4 1/8" EXISTING STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING - "PILASTER" EXISTING FRAME EXISTING JAMB EXISTING STOP: 1/2" X 3" (SCREW ATTACHED) PAINTED WOOD SASH INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED 4 1/2" +/- EXTERIOR STOP PROPABLE CONDITIONS AT COUNTER WEIGHTS: SEPARATED BY ZINC METAL STRIP. NOTE: HEADS HAVE SIMILAR VOIDS WITH NO WEIGHTS. LINE OF PLASTER BOOKCASE IN SOME LOCATIONS 5"+/-EXISTING JAMB Scale: 3" = 1'-0" EX-2 A-3.4 EXTERIOR CASING - "PILASTER" 7 3/4" +/-5" +/-INTERIOR WD. TRIM PAINTED WOOD FRENCH OUT-SWING CASEMENT SASH 8" +/-EXTERIOR CASING - "PILASTER" DASHED LINES OF BLINDS AT HEAD CASING EXISTING MULLION Scale: 3" = 1'-0" EX-3 A-3.4 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 2. PREVIOUS WEIGHT POCKET 6. FOAM CAVITIES 13. CAULK JOINT 9. NEW WINDOW 3/16" FIELD-APPLIED DECORATIVE CASINGS (PAINTED, COMPOSITE MATERIAL). SK1A 8. PEEL & STICK PROPOSED JAMB Scale: 3" = 1'-0" 2 A-3.4 14. EXISTING SILL 4. SASH STOP & NEW TRIM 9. NEW WINDOW 8. PEEL & STICK 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL 6. FOAM CAVITIES PROPOSED SILL Scale: 3" = 1'-0" 1 A-3.44. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 9. NEW WINDOW FIELD-APPLIED DECORATIVE CASINGS (PAINTED, COMPOSITE MATERIAL). 17. BLINDS 3/16"3/16" NEW PICTURE UNIT AT LOCATION OF FORMER FRENCH CASEMENT ADD BLOCKING AS NEEDED AND INSULATE ANY CAVITIES CUT EXISTING FRAME AS NEEDED SK-1 PROPOSED MULLION Scale: 3" = 1'-0" 3 A-3.4 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 FIELD APPLIED CASING, INSTALL OVER ALUMINUM EXTENSION JAMBS WINDOW ELEVATION Scale: 1/4" = 1'-0" 4 A-3.4 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DH AT FORMER IN-SWING FRENCH CSMNTS A-3.5 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DH AT FORMER IN-SWING FRENCH CSMNTS A-3.5 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 BRICK OR STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING UNKNOWN CONDITIONS BEHIND FRAME - POSSIBLY FORMER DH WEIGHT POCKETS PAINTED WOOD FRENCH CASEMENT SASH INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED 4 1/4" +/- LINE OF PLASTER 4 1/2" +/-5" +/-5" +/- EXISTING INTERIOR SCREEN DASHED LINE OF BLINDS AT HEAD CASING EXISTING JAMB Scale: 3" = 1'-0" EX-2 A-3.5 INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED SLOPED, PAINTED WOOD SILL 3" +/-EXISTING SILL Scale: 3" = 1'-0" EX-1 A-3.5 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK DETERMINE IF THERE IS A CAVITY. EXISTING CASEMENTS WOULD NOT HAVE WEIGHTS. DRILL FRAME AND FOAM. 13. CAULK JOINT 9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3/16" CUT FRAME AS NEEDED TO ENABLE NEW DOUBLE HUNG WINDOW TO SIT CLOSER TO M.O. THAN PREVIOUS CASMENT UNIT, TO MAINTAIN SAME EXTERIOR CASINGS AS OTHER INSTALLATIONS.     14. EXISTING SILL 4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL CUT FORMER CASEMENT FRAME / SILL AS NEEDED TO ENABLE NEW DOUBLE HUNG WINDOW TO SIT CLOSER SUB SILL, IN SIMILAR RELALTIONSHIP AS OTHER LOCATIONS. 6. FOAM CAVITIES PROPOSED SILL Scale: 3" = 1'-0" 1 A-3.5 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DH AT FORMER OUT SWING FRENCH CSMNTS A-3.6 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DH AT FORMER OUT SWING FRENCH CSMNTS A-3.6 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 BRICK OR STUCCO ON BRICK SLOPED, PAINTED WOOD SILL EXTERIOR CASING UNKNOWN CONDITIONS BEHIND FRAME - POSSIBLY FORMER DH WEIGHT POCKETS PAINTED WOOD FRENCH CASEMENT SASH INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED 2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP LINE OF PLASTER 4 1/2" +/-10 1/2" +/- SILL1'-9" +/- RADIATOR COVER5" +/-3 1/4" +/-5" +/- EXISTING INTERIOR SCREEN LINE OF BLINDS AT HEAD CASING EXISTING JAMB Scale: 3" = 1'-0" EX-2 A-3.6 INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED SLOPED, PAINTED WOOD SILL EXTERIOR CASING & SASH STOP EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) EXISTING PARTING STRIP ??????? +/-3" +/-1'-9" +/- RADIATOR COVER EXISTING SILL Scale: 3" = 1'-0" EX-1 A-3.6 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK DETERMINE IF THERE IS A CAVITY. EXISTING CASEMENTS WOULD NOT HAVE WEIGHTS. DRILL FRAME AND FOAM. 13. CAULK JOINT 9. NEW WINDOW 11. EXTERIOR CASING, 3 SIDES 3/16" 3" +/- CUT FRAME AS NEEDED TO ENABLE NEW DOUBLE HUNG WINDOW TO SIT CLOSER TO M.O. THAN PREVIOUS CASMENT UNIT, TO MAINTAIN SAME EXTERIOR CASINGS AS OTHER INSTALLATIONS.     14. EXISTING SILL 4. SASH STOP & NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 7. REFINISH SILL CUT FORMER CASEMENT FRAME / SILL AS NEEDED TO ENABLE NEW DOUBLE HUNG WINDOW TO SIT CLOSER SUB SILL, IN SIMILAR RELALTIONSHIP AS OTHER LOCATIONS. 6. FOAM CAVITIES     GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 PAINTED WOOD CORNER BOARD SLOPED, PAINTED WOOD SILL EXTERIOR CASING & SASH STOP LINE OF PLASTER AT NARROW DORMER PAINTED WOOD SASH INTERIOR WOOD SILL, PAINTED SASH POCKET APPROX. 3 1/2"; CONFIRM IN FIELD EXISTING FRAME EXISTING JAMB EXISTING STOP: 1/2" X 2.5" (SCREW ATTACHED) PROPABLE CONDITIONS AT COUNTER WEIGHTS: SEPARATED BY ZINC METAL STRIP. NOTE: HEADS HAVE SIMILAR VOIDS WITH NO WEIGHTS. INTERIOR WOOD TRIM, PAINTED EXISTING JAMB - ATTIC Scale: 3" = 1'-0" EX-2 A-3.7 SASH POCKET APPROX. 3 1/2" INTERIOR WOOD TRIM, PAINTED INTERIOR WOOD SILL, PAINTED ALUM. STORM WINDOW TRACK EXTERIOR CASING & SASH STOP EXISTING STOP: 1/2" X 1.75 (SCREW ATTACHED)3" +/-EXISTING PARTING STRIP SLOPED, PAINTED WOOD SILL SLATE ROOF EXISTING SILL Scale: 3" = 1'-0" EX-1 A-3.7 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 ATTIC WINDOW A-3.7 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 ATTIC WINDOW A-3.7 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 3/16" 4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 2. PREVIOUS WEIGHT POCKET 6. FOAM CAVITIES 9. NEW WINDOW 13. CAULK JOINT 8. PEEL & STICK 17. BLINDS REPLACE CASINGS WITH FLAT, PICTURE FRAMED COMPOSITE TRIM     14. EXISTING SILL 4. NEW TRIM 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 1. REMOVE STORMS COVER WOOD SUBSILL WITH ALUM BRAKE METAL. THIS IS PART OF BASE BID FOR ATTIC LEVEL WINDOWS. CLARIFICATION: ALUMINUM BREAK METAL TO BE PROVIDED AND INSTALLED UNDER SECTION 06060. COLOR: WHITE ADD2-13     GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 LIBRARY DOOR TO WINDOW A-3.8 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 LIBRARY DOOR TO WINDOW A-3.8 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 6. FOAM CAVITIES 13. CAULK JOINT 3. INTERIOR TRIM NEW SASH STOP 10. SHIM SPACE NEW INTERIOR WOOD TRIM 3/16" 17. BLINDS EXISTING DOOR FRAME, COVERED IN PLACE 8. PEEL & STICK 11. EXTERIOR CASING, 3 SIDES 9. NEW WINDOW     6. FOAM CAVITIES NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS IN ADJACENT ROOM, PAINT. NEW INSULATED STUD WALL. EXISTING DOOR THRESHOLD, REMOVE OR CUT TO COVER IN PLACE NEW PAN FLASHING 1'-0" AT TYPE W 2'-0" AT TYPE ZCONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT BOTTOM EDGE AND CORNERS.     LIBRARY DOOR TO WINDOW EXISTING DOOR FRAME, COVERED IN PLACE 6. FOAM CAVITIES 13. CAULK JOINT 3. INTERIOR TRIM NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS IN ADJACENT ROOM. MATCH FACTORY CASINGS WITH COMPOSITE MATERIAL, PAINTED CONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT EDGES AND SEAMS. NEW INSULATED STUD WALL.    3/16"4. SASH STOP & NEW TRIM 10. SHIM SPACE 3. INTERIOR TRIM 8. PEEL & STICK INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. 9. NEW WINDOW EXTERIOR CASING. FIELD OR FACTORY APPLIED.     GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 NEW PAINTED WOOD INTERIOR SILL 9. NEW WINDOW W/ TEMPERED LOWER SASH AT TYPE W 12. FRAME EXPANDER 10. SHIM SPACE NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS IN ADJACENT ROOM, PAINT. NEW INSULATED STUD WALL. NEW PAN FLASHING NEW SILL, COMPOSITE MATERIAL, PAINTED 1'-0" AT TYPE W 2'-0" AT TYPE ZCONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT BOTTOM EDGE AND CORNERS. ADD 1-5 ADD 1-5 SEE PHOTOS PROVIDED BY ADD2-14 FOR INTENT OF WOOD PANEL MATCH NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS IN ADJACENT ROOM, PAINT. NEW INSULATED STUD WALL. EXISTING SLOPED CONCRETE DOOR THRESHOLD 2'-0"NEW P.T. BUCKS WITH TWO BEADS OF SEALANT CONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT BOTTOM EDGE AND CORNERS.    SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 LAUNDRY DOOR TO WINDOW A-3.9 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 LAUNDRY DOOR TO WINDOW A-3.9 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 13. CAULK JOINT NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS ON 2ND FLOOR. PAINTED COMPOSITE OR RUBBER CASINGS (MATCH FACTORY CASINGS) CONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT EDGES AND SEAMS. NEW INSULATED STUD WALL. EXTERIOR STUCCO LINE OF INTERIOR STUCCO    BASEMENT DOOR TO BI-PARTING ARCHED CASEMENT WINDOW EXTERIOR STUCCO LINE OF INTERIOR STUCCO 13. CAULK JOINT      10. SHIM SPACE NEW INTERIOR WOOD TRIM 9. NEW ARCHED FRENCH BI-PARTING WINDOW 8. PEEL & STICK 5 1/2"NEW P.T. BUCKS WITH TWO BEADS OF SEALANT PAINTED COMPOSITE OR RUBBER CASINGS - CURVED ABOVE 3 5/8" +/-    GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 LINE OF INTERIOR STUCCO 3 5/8" +/-5 1/2" 4. SASH STOP & NEW TRIM 10. SHIM SPACE 8. PEEL & STICK INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. 9. NEW WINDOW NEW P.T. BUCKS WITH TWO BEADS OF SEALANT VARIESPAINTED COMPOSITE OR RUBBER CASINGS - CURVED ABOVE     NEW PAINTED WOOD INTERIOR SILL 9. NEW FRENCH BI-PARTING, ARCHED WINDOW 12. FRAME EXPANDER 10. SHIM SPACE 6. FOAM CAVITIES NEW INTERIOR WOOD PANELING, MATCH PROPORTIONS TO PANELS IN ADJACENT ROOM, PAINT. NEW INSULATED STUD WALL. EXISTING SLOPED CONCRETE DOOR THRESHOLD NEW SILL, COMPOSITE MATERIAL, PAINTED 2'-0"CONTINOUS AIR BARRIER AT EXTERIOR SIDE OF SHEATHING, PEEL AND STICK TAPED AT BOTTOM EDGE AND CORNERS. SEE PHOTOS PROVIDED BY ADD2-14 FOR INTENT OF WOOD PANEL MATCH SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BASEMENT SLIDING WDW. A-3.10 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 BASEMENT SLIDING WDW. A-3.10 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 NEW PAINTED WOOD INTERIOR SILL 9. NEW WINDOW 12. FRAME EXPANDER 10. SHIM SPACE EXISTING SLOPED CONCRETE WINDOW SILL NEW P.T. BUCKS WITH TWO BEADS OF SEALANT STONE WINDOW WELL, VARIES IN HEIGH TAND LOCATION BASEMENT WINDOW SILL Scale: 3" = 1'-0" 2 A-3.10 LINE OF INTERIOR STUCCO 10. SHIM SPACE 8. PEEL & STICK NEW P.T. BUCKS WITH TWO BEADS OF SEALANT 13. CAULK JOINT 11. EXTERIOR EXTENSION JAMBS, 3 SIDES 9. NEW FIBERGLASS GLIDING WINDOW BASEMENT WINDOW HEAD Scale: 3" = 1'-0" 3 A-3.10 EXTERIOR BRICK LINE OF INTERIOR STUCCO, REPAIR AS NEEDED 13. CAULK JOINT 10. SHIM SPACE NEW INTERIOR EXTENSION JAMB AND FACE TRIM 9. NEW FIBERGLASS GLIDING WINDOW 11. EXTERIOR EXTENSION JAMBS, 3 SIDES 8. PEEL & STICK NEW P.T. BUCKS WITH TWO BEADS OF SEALANT BASEMENT WINDOW JAMB Scale: 3" = 1'-0" 1 A-3.10 STUCCO ON CONCRETE EXTERIOR CASING STEEL SASH CONCRETE, STEPS IN OPENING NOT KNOWN, DETERMINE IN FIELD EXISTING GARAGE JAMB Scale: 3" = 1'-0" EX-2 A-3.11 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 GARAGE WINDOWS A-3.11 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 GARAGE WINDOWS A-3.11 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 EXTERIOR STUCCO 13. CAULK JOINT 10. SHIM SPACE NEW INTERIOR WOOD TRIM 9. NEW CASEMENT WINDOW 8. PEEL & STICK 11. FIELD-APPLIED EXTENSION JAMB AND CASING, 3 SIDES CONCRETE WALL CONDITIONS OF CONCRETE OPENING NOT KNOWN, DETERMINE IN FIELD IF STANDARD CASINGS FIT AS SHOWN,2 3/4" +/-SK-2 PROPOSED GARAGE JAMB Scale: 3" = 1'-0" 2 A-3.11 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 NEW PAINTED WOOD INTERIOR SILL AND ARPON 9. NEW CASEMENT WINDOW 12. FRAME EXPANDER 10. SHIM SPACE NEW SILL, MATCH PROFILE OF EXISTING WITH COMPOSITE MATERIAL, PAINTED NEW P.T. BUCKS WITH TWO BEADS OF SEALANT 6. FOAM CAVITIES CUT CONCRETE AS NEEDED TO PLACE NEW BUCK IN PROPER RELATIONSHIP TO REPLACED WINDOW SILL. PROPOSED GARAGE WINDOW SILL Scale: 3" = 1'-0" 1 A-3.11 CONCRETE, STEPS IN OPENING NOT KNOWN, DETERMINE IN FIELD WOOD SILL EXISTING GARAGE WINDOW SILL Scale: 3" = 1'-0" EX-1 A-3.11 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 GARDENER'S WINDOWS A-3.12 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 GARDENER'S WINDOWS A-3.12 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 GENERAL NOTES FOR WINDOW REPLACEMENT 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN LOCATIONS WHERE THEY OCCUR. 1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS NEEDED TO INSTALL NEW FRAME. REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED. DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE WEIGHTS. IF NOT, CUT FRAME AS NEEDED. INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES. REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM EXTERIOR. IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY OPENING (APOXY ANCHORS) FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL. EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON COMPLETION. EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS NEEDED WITH COMPOSITE MATERIAL (SEE UNIT PRICES). APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL CAVITIES. INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS WITH ANCHORS. INSULATE SHIM SPACE EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING JOINT. SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER, FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR DRAINAGE; DO NOT CAULK. INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES, PANELS, ETC. INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY) INTO MASONRY WALL ACCORDING TO MANUFACTURER'S INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS. EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR REPLACED. EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT. ADD1-3, ADD2-12 and ADD3-10 NEW PAINTED WOOD INTERIOR SILL AND ARPON 9. NEW CASEMENT WINDOW 12. FRAME EXPANDER 10. SHIM SPACE EXISTING STONE SILL NEW P.T. BUCKS WITH TWO BEADS OF SEALANT   CUT CONCRETE AS NEEDED TO PLACE NEW BUCK IN PROPER RELATIONSHIP TO REPLACED WINDOW SILL. 4 1/4" +/- PROPOSED SILL Scale: 3" = 1'-0" 2 A-3.12 STEPS IN MASONRY OPENING NOT KNOWN, DETERMINE IN FIELD. WOOD SILL CONCRETE SUBSILL 4" +/- EXISTING SILL Scale: 3" = 1'-0" EX-2 A-3.12 9. NEW CASEMENT WINDOW SK-3A PROPOSED HEAD Scale: 3" = 1'-0" 3 A-3.12 11. FIELD-APPLIED EXTENSION JAMB AND CASING, 3 SIDES SK-3 13. CAULK JOINT 10. SHIM SPACE NEW INTERIOR WOOD TRIM 9. NEW CASEMENT WINDOW 8. PEEL & STICK CONCRETE WALL CONDITIONS OF MASONRY OPENING NOT KNOWN, DETERMINE IN FIELD IF STANDARD CASINGS FIT AS SHOWN, NEW P.T. BUCKS WITH TWO BEADS OF SEALANT4 1/4" +/-PROPOSED JAMB Scale: 3" = 1'-0" 1 A-3.12 STEEL LINTEL STONE EXISTING HEAD Scale: 3" = 1'-0" EX-3 A-3.12 EXTERIOR CASING STEEL SASH STONE EXISTING JAMB Scale: 3" = 1'-0" EX-1 A-3.12 NEW NARROW STYLE ALUMINUM CLAD DOOR AND FRAME EXISTING WOOD FLOORING, RAPAIR AND TOUCH UP AS NEEDED AT FORMER SILL REMOVAL. SET SILL IN SEALANT EXISTING STONE SILL PAN FLASHING NEW SCREEN DOOR BY DOOR MANUFACTURER SILL Scale: 3" = 1'-0" 2 A-4.0 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DOORS LOGGIA AND STAIR A-4.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DOORS LOGGIA AND STAIR A-4.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 STUCCO ON BRICK DETERMINE IN FIELD IF FACTORY-INSTALLED CASING CAN BE PROVIDED AT THIS OPENING. COMPOSITE EXTERIOR CASING OTHERWISE ACCEPTABLE. INTERIOR WOOD TRIM, PAINTED LINE OF PLASTER 4 1/2" +/- 3/16"NEW SCREEN DOORS BY DOOR MANUFACTURER NEW NARROW STYLE ALUMINUM CLAD DOOR AND FRAME PEEL AND STICK WRAPPED TO M.O. EXISTING BLOCKING OR NEW AS NEEDED INSULATED SHIM SPACE DOOR JAMB - LOGGIA Scale: 3" = 1'-0" 1 A-4.0 EXISTING STUCCO ON BRICK REPLACE COPPER ROOF FLASHING AS NEEDED EXISTING EXTERIOR CASING AND PANEL, PAINTED INTERIOR WOOD TRIM, PAINTED LINE OF PLASTER 3/16" PEEL AND STICK CAULKING SHIM SPACE DOUBLE DOOR JAMB AND MULLION Scale: 3" = 1'-0" 5 A-4.0 STUCCO ON BRICK CLAD OR COMPOSITE CASING EXISITNG INTERIOR WOOD TRIM, PAINTED 10 1/2" +/- TRANSOM3/16"NEW INTERIOR WOOD TRIM, PAINTED REMOVE EXISTING FRAME ENTIRELY NEW TRANSOM UNIT PEEL AND STICK TRANSOM HEAD Scale: 3" = 1'-0" 4 A-4.0 BRICK OR STUCCO ON BRICK EXISTING INTERIOR WOOD TRIM, PAINTED4 1/2" +/-3/16"RETAIN CURVED EXTERIOR CASING AS POSSIBLE BY INSTALLING UNIT FROM INSIDE, OR CAREFULLY REMOVING AND REINSTALLING TRIM. NEW CURVED, INTERIOR WOOD TRIM, PAINTED PEEL AND STICK SHIM SPACE PAINTED INTERIOR MULL BY WINDOW MANUFACTURER NEW CURVED, TRANSOM UNIT ARCHED TRANSOM VARIESTRANSOM HEAD Scale: 3" = 1'-0" 8 A-4.0 OUTSWING DOOR AT STAIR INSWING DOOR AT LOGGIA GENERAL NOTES FOR DOOR REPLACEMENT 1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST) FOR REPAIR AND REINSTALLATION. 2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR, SILL AND DOOR FRAME 3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED 4.FOAM ALL CAVITIES 5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING / BUCKS 6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE DRAINAGE AWAY FROM WALL AND DOOR SILL. 7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O. AT CORNERS. 8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR EXISTING WOOD BUCKS, TURNING ONTO MASONRY AND LAPPING PAN FLASHING. 9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING OR NEW BUCKS. 10.INSULATE SHIM SPACE 11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR CASING, PAINTED 12.INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. 13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. 14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT 15.REINSTALL REPAIRED SCREEN DOORS, REPLACING CLOSERS / HOLD OPENS. CLAD OR COMPOSITE CASING 10 1/2" +/- TRANSOMREMOVE EXISTING FRAME ENTIRELY NEW TRANSOM UNIT NEW NARROW STYLE ALUMINUM CLAD DOOR AND FRAME3"SET SILL IN SEALANT NEW SCREEN DOOR BY DOOR MANUFACTURER MULLION Scale: 3" = 1'-0" 3 A-4.0 BRICK OR STUCCO ON BRICK NEW COPPER PAN FLASHING FULL WIDTH OF DOOR AND CORNERS, EXTENDING MIN. OF 4" OVER EXISTING ROOFING. RETAIN CURVED EXTERIOR CASING AS POSSIBLE BY INSTALLING UNIT FROM INSIDE, OR CAREFULLY REMOVING AND REINSTALLING TRIM. NEW CURVED, INTERIOR WOOD TRIM, PAINTED REMOVE EXISTING FRAME ENTIRELY NEW NARROW STYLE ALUMINUM CLAD DOOR AND FRAME3"CAULKING PAINTED INTERIOR MULL BY WINDOW MANUFACTURER NEW CURVED, TRANSOM UNIT ARCHED TRANSOM VARIESMULLION Scale: 3" = 1'-0" 7 A-4.0 NEW SILL EXTENDS OVER TRIM AND STEP BELOW REMOVE EXISTING SILL AND REPLACE WITH NEW 2x P.T. BLOCKING NEW COPPER PAN FLASHING FULL WIDTH OF DOOR AND CORNERS, EXTENDING MIN. OF 4" OVER EXISTING ROOFING. NEW TRIM REPLACE COPPER ROOFING AS NEEDED SET DOOR SILL ON SEALANT 2 1/8" +/- RETAIN CURVED EXTERIOR CASING AS POSSIBLE BY INSTALLING UNIT FROM INSIDE, OR CAREFULLY REMOVING AND REINSTALLING TRIM. REMOVE EXISTING FRAME ENTIRELY NEW NARROW STYLE ALUMINUM CLAD DOOR AND FRAME3"CAULKING PAINTED INTERIOR MULL BY WINDOW MANUFACTURER SILL Scale: 3" = 1'-0" 6 A-4.0 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DECK DOOR SECOND FLOOR A-4.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 DECK DOOR SECOND FLOOR A-4.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 GENERAL NOTES FOR DOOR REPLACEMENT 1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST) FOR REPAIR AND REINSTALLATION. 2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR, SILL AND DOOR FRAME 3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED 4.FOAM ALL CAVITIES 5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING / BUCKS 6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE DRAINAGE AWAY FROM WALL AND DOOR SILL. 7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O. AT CORNERS. 8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR EXISTING WOOD BUCKS, TURNING ONTO MASONRY AND LAPPING PAN FLASHING. 9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING OR NEW BUCKS. 10.INSULATE SHIM SPACE 11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR CASING, PAINTED 12.INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. 13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. 14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT 15.REINSTALL REPAIRED SCREEN DOORS, REPLACING CLOSERS / HOLD OPENS. SECOND FLOOR DOORS TO DECK WITH WINDOWS TO EITHER SIDE STUCCO ON BRICK INTERIOR WOOD TRIM, PAINTED REMOVE EXISTING SILL AND REPLACE WITH NEW P.T. BLOCKING, RAISING NEW SILL APPROXIMATELY 1". COORDINATE WITH MANUFACTURER'S DOOR HEIGHT. 3 LAYERS OF NEW FLASHING: REMOVE SUFFIENT DECKING AND SLEEPERS TO ACCESS ROOF FLASHINGS. REMOVE AND INSTALL FIRST LAYER OF NEW MEMBRANE FLASHING FROM BELOW NEW SUBSILL EXTENDING 12" OVER ROOF. SECOND LAYER OF MEMBRANE FLASHING TO COVER NEW SUBSILL AND EXTEND 12" OVER LOWER FLASHING. THIRD LAYER TO BE CONTINUOUS COPPER DOOR PLAN FLASHING ACTING AS COUNTER FLASHING AT SILL AND FOLDING UP SIDES OF R.O. FIELD-APPLY NEW DECORATIVE CASINGS (PAINTED, COMPOSITE MATERIAL) INSTALLED ON TOP OF MANUFACTURER-PROVIDE D EXTENSION JAMBS / MULLS. INTERIOR WOOD TRIM, PAINTED REMOVE EXISTING FRAME HEAD CONDITIONS UNKNOWN. DETERMINE IN FIELD. DOOR HEAD Scale: 3" = 1'-0" 3 A-4.1 3/16"REMOVE EXISTING CASINGS TO INSTALL DOOR AND WINDOW. FIELD-APPLY NEW DECORATIVE CASINGS (PAINTED, COMPOSITE MATERIAL) INSTALLED ON TOP OF MANUFACTURER-PROVIDED EXTENSION JAMBS / MULLS. ADD BLOCKING AS NEEDED AND INSULATE ANY CAVITIES NEW TRIM PEEL AND STICK SHIM SPACE 3/16"SCREEN DOOR BY DOOR MANUFACTURER EXISTING INTERIOR WOOD TRIM, PAINTED DOOR JAMB (AT WINDOW MULLION) Scale: 3" = 1'-0" 1 A-4.1 PHOTO OF EXISTING DOOR SILL AT DECK Scale: Actual Size 1 A-4.1 REMOVE EXISTING SILL AND REPLACE WITH NEW P.T. BLOCKING, RAISING NEW SILL APPROXIMATELY 1". COORDINATE WITH MANUFACTURER'S DOOR HEIGHT. 3 LAYERS OF NEW FLASHING: REMOVE SUFFIENT DECKING AND SLEEPERS TO ACCESS ROOF FLASHINGS. REMOVE AND INSTALL FIRST LAYER OF NEW MEMBRANE FLASHING FROM BELOW NEW SUBSILL EXTENDING 12" OVER ROOF. SECOND LAYER OF MEMBRANE FLASHING TO COVER NEW SUBSILL AND EXTEND 12" OVER LOWER FLASHING. THIRD LAYER TO BE CONTINUOUS COPPER DOOR PLAN FLASHING ACTING AS COUNTER FLASHING AT SILL AND FOLDING UP SIDES OF R.O. SET DOOR SILL ON SEALANT FIELD-APPLY NEW DECORATIVE CASINGS (PAINTED, COMPOSITE MATERIAL) INSTALLED ON TOP OF MANUFACTURER-PROVIDE D EXTENSION JAMBS / MULLS. INTERIOR WOOD TRIM, PAINTED REMOVE EXISTING FRAME EXTERIOR DECKING APPROXIMATE LINE OF ROOF BELOW NEW INTERIOR TRIM, NATURAL FINISH. DOOR SILL AT DECK Scale: 3" = 1'-0" 2 A-4.1 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 ARCHED DOORS BASEMENT A-4.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS: DATENUMBER JAN. 19, 2016 ARCHED DOORS BASEMENT A-4.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT AND CONSTRUCTION SET ADD-1 JAN. 22, 2016 ADD-2 FEB. 9, 2016 ADD-3 FEB. 17, 2016 EXISTING SLOPED CONCRETE DOOR THRESHOLD NEW SILL SET IN SEALANT DOOR SILL Scale: 3" = 1'-0" 2 A-4.2 BASEMENT ARCHED DOORS WITH SIDELITES LINE OF INTERIOR STUCCO 2 3/4" +/- INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. NEW P.T. BUCKS WITH TWO BEADS OF SEALANT VARIES5 1/2" PAINTED COMPOSITE OR RUBBER CASINGS - CURVED ABOVE CURVED FRAME AND DOOR HEAD REPAIR AND RE-INSTALL EXISTING ARCHED SCREEN DOOR COMPLETELY REMOVE EXISTING DOOR FRAME DOOR HEAD Scale: 3" = 1'-0" 3 A-4.2 5 1/2"LINE OF INTERIOR STUCCO CAULK JOINT NEW INTERIOR WOOD TRIM 2 3/4" +/-3/16" NEW P.T. BUCKS WITH TWO BEADS OF SEALANT DOOR FRAME, FACTORY MULLED SIDELIGHT SASH COMPLETELY REMOVE EXISTING DOOR FRAME REPAIR AND RE-INSTALL EXISTING ARCHED SCREEN DOOR PEEL AND STICK AND INSULATED SHIM SPACE DETERMINE IN FIELD IF FACTORY-INSTALLED CURVED CASING CAN BE PROVIDED AT THIS OPENING. COMPOSITE EXTERIOR CASING OTHERWISE ACCEPTABLE. DOOR JAMB Scale: 3" = 1'-0" 1 A-4.2 GENERAL NOTES FOR DOOR REPLACEMENT 1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST) FOR REPAIR AND REINSTALLATION. 2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR, SILL AND DOOR FRAME 3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED 4.FOAM ALL CAVITIES 5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED BLOCKING / BUCKS 6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE DRAINAGE AWAY FROM WALL AND DOOR SILL. 7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O. AT CORNERS. 8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR EXISTING WOOD BUCKS, TURNING ONTO MASONRY AND LAPPING PAN FLASHING. 9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING OR NEW BUCKS. 10.INSULATE SHIM SPACE 11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR CASING, PAINTED 12.INSTALL NEW BACKER ROD AND CAULK JOINT, MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2" PREFERRED. 13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. 14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER SEPARATE CONTRACT 15.REINSTALL REPAIRED SCREEN DOORS, REPLACING CLOSERS / HOLD OPENS. KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 WINDOW SCHEDULE A-5.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 WINDOW SCHEDULE A-5.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSED Sash Operation - Muntin PatternGlazingVerify Opening - Masonry Approx. (stop to stop) Approx. Interior Opening Color Material and Exterior Finish: Finish Material and Frame: Interior Finish Material and Interior Sash: Finish Material and Interior Trim: Treatment Existing Window Shutters Exterior Existing Shutters Interior Existing Comments 0 01-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 02-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 03-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 04-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 05-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 06-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 07-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 08-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 09-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 10-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 11-Z Room Gardener's DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR 0 12-Q Room Gardener's CASEMENT FRENCH METAL BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False 0 13-X Room Laundry DOOR W/ PANEL BELOW BI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK 5'-6"x 6'-10" AT TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR 0 14-V Room Laundry DOOR W/ PANEL BELOW BI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK 5'-0" x 6'-7" AT TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR 1 01-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False 1 02-R Guest INSWING FRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED 1 03-R Guest INSWING FRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False 1 05-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 06-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 07-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 08-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False 1 09-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False 1 10-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 11-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 12-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 13-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False 1 14-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZED EXISTING WINDOW IS AN INSERT REPLACEMENT, 1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False 1 16-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False 1 17-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 18-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 19-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 20-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill 1 21-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head 1 22-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 23-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False 1 24-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 1 26-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 27-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 28-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 2 01 -S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 02 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 03 -C Guest 206 INSWING FRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 04 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 05 -D Guest 206 OUTSWING FRENCH CASEMENT DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 06 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 07 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 08 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 09 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 10 -D Master Bdrm OUTSWING FRENCH CASEMENT DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 11 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 12 -C Master Bdrm OUTSWING FRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 13 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 14 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE 2 15 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False 2 16 -H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 17 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 18 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 19 -H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL 2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO 2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO 2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False 2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 30-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 2 31-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True 3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 08 SIM -F Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False ADD 1-8 ADD 1-8 WINDOW TREATMENT KEY: V= VALENCE PS=PULL SHADE D=DRAPES KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 WINDOW SCHEDULE & ELEVATIONS A-5.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 WINDOW SCHEDULE & ELEVATIONS A-5.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSED Sash Operation - Muntin PatternGlazingVerify Opening - Masonry Approx. (stop to stop) Approx. Interior Opening Color Material and Exterior Finish: Finish Material and Frame: Interior Finish Material and Interior Sash: Finish Material and Interior Trim: Treatment Existing Window Shutters Exterior Existing Shutters Interior Existing Comments 0 01-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 02-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 03-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 04-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 05-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 06-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 07-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 08-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 09-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 10-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False 0 11-Z Room Gardener's DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR 0 12-Q Room Gardener's CASEMENT FRENCH METAL BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False 0 13-X Room Laundry DOOR W/ PANEL BELOW BI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK 5'-6"x 6'-10" AT TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR 0 14-V Room Laundry DOOR W/ PANEL BELOW BI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK 5'-0" x 6'-7" AT TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR 1 01-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False 1 02-R Guest INSWING FRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED 1 03-R Guest INSWING FRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False 1 05-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 06-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 07-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False 1 08-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False 1 09-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False 1 10-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 11-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 12-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat 1 13-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False 1 14-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZED EXISTING WINDOW IS AN INSERT REPLACEMENT, 1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False 1 16-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False 1 17-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 18-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 19-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 1 20-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill 1 21-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head 1 22-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 23-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False 1 24-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 1 26-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 27-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 1 28-P Garage CASEMENT FRENCH METAL SINGLE CASEMENT PARTING STRIP OF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False 2 01 -S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 02 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 03 -C Guest 206 INSWING FRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 04 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 05 -D Guest 206 OUTSWING FRENCH CASEMENT DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False 2 06 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 07 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 08 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 09 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True 2 10 -D Master Bdrm OUTSWING FRENCH CASEMENT DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 11 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 12 -C Master Bdrm OUTSWING FRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 13 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False 2 14 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE 2 15 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False 2 16 -H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 17 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 18 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 19 -H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL 2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO 2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO 2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False 2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 30-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 2 31-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True 3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 08 SIM -F Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSEDSash Operation - Muntin PatternGlazingVerifyOpening - Masonry Approx. (stop to stop)Approx. Interior Opening ColorMaterial and Exterior Finish: FinishMaterial and Frame: Interior FinishMaterial and Interior Sash: FinishMaterial and Interior Trim: TreatmentExisting Window ShuttersExterior Existing ShuttersInterior Existing Comments001-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False002-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False003-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False004-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False005-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False006-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False007-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False008-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False009-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False010-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False011-Z RoomGardener's DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR012-Q RoomGardener's CASEMENTFRENCH METAL BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False013-X RoomLaundry DOOR W/ PANEL BELOWBI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK5'-6"x 6'-10" AT TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR014-V RoomLaundry DOOR W/ PANEL BELOWBI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK5'-0" x 6'-7" AT TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR101-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False102-R Guest INSWINGFRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED103-R Guest INSWINGFRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False105-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False106-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False107-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False108-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False109-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False110-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat111-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat112-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat113-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False114-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZEDEXISTING WINDOW IS AN INSERT REPLACEMENT, 1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False116-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False117-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True118-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True119-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True120-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill121-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head122-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False123-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False124-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True126-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False127-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False128-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False201-S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False202-B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False203-C Guest 206 INSWINGFRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False204-B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False205-D Guest 206 OUTSWINGFRENCH CASEMENT DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False206-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True207-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True208-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True209-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True210-D Master Bdrm OUTSWINGFRENCH CASEMENT DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False211-B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False212-C Master Bdrm OUTSWINGFRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False213-B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False214-H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE215-H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False216-H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True217-H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True218-H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True219-H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True 2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL 2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO 2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO 2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO 2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False 2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH TEMPERED CLEAR/INSUL, 39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR 2 30-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 2 31-N STUDY DH 6/6 TEMPERED CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24") SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT 3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True 3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False 3 08 SIM -F Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False ALL WINDOW ELEVATIONS SCALE: 1/4"=1'-0" SIMBADCBA FRENCH CASEMENT CHANGED TO DH (2 TOTAL) COMBINATION WINDOW WITH CENTRAL FRENCH CASEMENT CHANGED TO COMBINATION WINDOW WITH CENTRAL FIXED PICTURE WINDOW(2 TOTAL) (2 TOTAL) DOUBLE DH 2ND FLOOR, LOGGIA SECOND FLOOR, SOUTHSECOND FLOOR, PRIVATE STUDY GEF H (4 TOTAL)(7 TOTAL) (+1 SIMILAR) (5 TOTAL) (9 TOTAL, 4 W/ SPLAYED INTERIOR WALL) SECOND FLOOR, MASTER SUITE KITCHEN/BUTLERS ATTIC 2ND FLOOR, NE (NEW) 1 3.3 3 3.3 2 3.3 2 3.3 1 3.3 2 3.0 1 3.0 1 3.0 (EXISTING)(PROPOSED) 2 3.4 1 3.4 3 3.4 1 3.6 2 3.6 (EXISTING)(PROPOSED) 3 3.1P 2 3.1P 2 3.0 FIELD APPLIED CASINGS, INSTALL OVER ALUMINUM EXTENSION JAMBS 1 3.7 2 3.7 F Q L K P J RGARDENER'S RM EAST (1 TOTAL) BI-PARTING CASEMENTRECEPTION (2 TOTAL) FIRST FLOOR NE (8 TOTAL, 4 WITH SPLAYED INTERIOR WALL) BASEMENT (7 TOTAL TO BE REPLACED WITH SLIDING UNIT) BAY WINDOW BEDROOM 206 (1 TOTAL) GUEST 110 (2 TOTAL, FRENCH CASEMENT TO BE REPLACED BY DH) M GARAGE (3 TOTAL) SINGLE CASEMENT WITH SIMULATED CENTER PARTING STRIP 1 3.1P 1 3.0P 2 3.0P 2 3.1P 4 3.2P 3 3.1P 1 3.5 2 3.5 (EXISTING)(PROPOSED) 3 3.2P N N204-H 2 3.11 2 3.4  3 3.4  2 4.1 TEMPERED GLASS ADJACENT TO DOORS (>24") 2 3.10 1 3.10 3 3.10 2 3.121 3.11 3 3.12 1 3.12 1 3.2P (12 TOTAL, SASHES ONLY, 2 EACH PER PREVIOUS OPENING)2 3.2P ADD 1-9 (2 TOTAL) EXISTING LIBRARY DOORS TO BE TURNED INTO DH WINDOW TYPE "W" WITH PANEL AND TEMPERED LOWER SASH 5'-6" V(1 TOTAL)X W (1 TOTAL) EXISTING GARDENER'S RM DOOR TO BE REPLACED BY FIXED WINDOW OVER WOOD PANEL (2 TOTAL) LIBRARY, TO BE REPLACED BY WINDOWS1'-0"(2 TOTAL) EXISTING LAUNDRY ROOM DOORS TO BE TURNED INTO WINDOWS: 013-X & 014-V (PROPOSED) (PROPOSED)(PROPOSED) (EXISTING)(PROPOSED)6'-7" +/- MO6'-10" +/- MO5'-0"(EXISTING) YBASEMENT (3 TOTAL WINDOWS TO BE REPLACED WITH MAPES PANELS) GARDENER'S RM NORTH Z 3 3.8 2 3.8 1 3.8 4 3.8 3 3.9 2 3.9 4 3.9 1 3.9 3 3.9 2 3.9 4 3.9 1 3.92'-0"2'-0"3.0P 2 3.10 (SIMILAR) 1 3.10 3 3.10 1 3.8 3 3.12 1 3.12 (SIMILAR) (SIMILAR) (SIMILAR) 38.5"73.5" +/- MOADD 1-9 2'-0"ADD 1-9 TEMP S T BEDROOM 206 (1 TOTAL) BATH 111 (1 TOTAL) 2 3.5 1 3.0P 2 3.0P M=MARVIN OPTION K=KOLBE OPTION 1 3.0P 2 3.0P WINDOW TREATMENT KEY: V= VALENCE PS=PULL SHADE D=DRAPES KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 DOOR SCHEDULE & ELEVATIONS A-5.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS: DATENUMBER JAN 19, 2016 DOOR SCHEDULE & ELEVATIONS A-5.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016 ADD-2 FEB. 9, 2016 ADD-2 FEB. 17, 2016 PERMIT AND CONSTRUCTION SET Door Schedule - ALTERNATE NO 2 Nominal Size Openings Door Data Mark Location Approx. WidthApprox. HeightDoor Operation HW SetApprox. RO WidthApprox. RO HeightExisting Window Treatment Comments 0 01-A GARDENER'S ROOM 3'0"6'8"Swing Simple 1 38.5"VARIES - PEAK AT 73.5"NONE 0 02-B FROM MECH. COURT 3'0"6'8"Swing Simple 1 67"VARIES - PEAK AT 82.5"NONE BELOW SCREEN DOOR; SEE NOTE 1, UTILIZE THE EXISTING 0 03-X LAUNDRY 3'0"6'8"Swing Simple 1 VARIES - PEAK AT 78"SEE NOTE 1, BELOW 1 05-D DINING TO LOGGIA 3'0"7'3"Swing Simple 2 39"89"FIXED LACE CURTAIN SEE NOTE 2, BELOW 1 06-E RECEPTION TO LOGGIA 4'0"7'4"Swing Bi-part 3 51"86"VALANCE AND DRAPES SEE NOTE 2, BELOW 1 07-D LIVING TO LOGGIA 3'0"7'3"Swing Simple 2 39.5"90"FIXED LACE CURTAIN SEE NOTE 2, BELOW 2 01-F STAIR TO FRONT BALCONY 4'0"8'0"Swing Bi-part 3 52"ARCHED TRANSOM VARIES TO TOP OF SHEER CURTAIN 2 04-H STUDY TO ROOF DECK 4'0"7'4"Swing Bi-part 3 WINDOWS INCLUDES DETERMINE IN FIELD VALANCE AND PULL SHADES NEW SILL 1". HEIGHT OF DOOR TO RAISE FLASHINGS AT SILL. ADJUST SCREEN DOORS. REPAIR (IN-SWING) AND ADD SLIDING REVERSE SWING OF DOORS 2 05-I PRIVATE STUDY TO BALCONY 4'0"7'3"Swing Bi-part 3 51"DETERMINE IN FIELD NONE AS NEEDED. REPAIR FLASHINGS AT SILL SWINGING SCREEN DOOR. SEE NOTE 2, BELOW FOR ADD 1-10 ADD 2-16 ADD 2-16 107-D 201-F LOGGIA, LR STAIR LANDING 8'-0"46" 105-D 106-E KITCHEN LOGGIA, DR LOGGIA, RECEPTION88" DOOR 4'-0" DOOR 51" MO +/- MO SIMILAR SIMILAR 1 4.0 1 4.0 4 4.0 2 4.0 SIMILAR 1 4.0 4 4.0 2 4.0 SIMILAR 1 4.0 3 4.0 2 4.0 4 4.0 5 4.0 7 4.0 6 4.0 8 4.0 NEW DOUBLE DOORS AND TRANSOM, NEW PAIR OF SWINGING SCREEN DOORS BY DOOR MANUFACTURER.ADD2-16 205-I STUDY 207 PRIVATE STUDY 205 REPLACE EXISTING DOOR, N N204-H 2 3.4  3 3.4  1 4.1 3 4.1 2 4.1 1 4.0 4 4.0 2 4.1 SIMILAR SIMILAR SIMILAR NEW PAIR OF SWINGING SCREEN DOORS BY DOOR MANUFACTURER.ADD2-16 1. EXISTING ARCHED SCREEN DOORS: A. REMOVE FOR REPAIR B. CUT SIDE AND BOTTOM STYLES AS NEED TO FIT INTO NEW DOOR FRAMES. C. PAINT D. REINSTALL WITH NEW CLOSER / HOLD OPEN 2. NEW RECTANGULAR SCREEN DOORS, SEE DRAWINGS FOR OPERATION (SWINGING OR SLIDING). SCREEN DOOR PANEL AND HARDWARE BY DOOR MANUFACTURER. 002-B WEST SOUTH-FACING LAUNDRY ROOM DOOR (2 TOTAL, TO BE TURNED INTO WINDOW, SEE WINDOW SCHEDULE)70.5" +/- MO82.5" +/- MO66" MO +/- MO 79" MO36"22"+/-79" MO70.5" +/- MO60" +/- MO 3'-0" 003-X EAST-FACING LAUNDRY ROOM DOOR (2 TOTAL, TO BE TURNED INTO WINDOW, SEE WINDOW SCHEDULE) 1 4.2 3 4.2 2 4.2 TEMPERED GLASS AT SIDELIGHTS ADJACENT TO DOORS (>24") THIS IS THE WINDOW ELEVEVATION 3 4.2 1 4.2 2 4.2 SIM SIM 70.5" +/- MO73.5" +/- MO38.5" MO GARDENER'S RM (1 TOTAL): WITH BIGGER LITE. OTHER DOOR TO BE TURNED TO WINDOW. 001-A THIS IS THE WINDOW ELEVEVATION 3 4.2 1 4.2 2 4.2 SIM ADD1-10