Smith Presidents House - CONSTRUCTION SET 2016-03-100.0 Title Page
A-1.0 BASEMENT PLAN
A-1.1 1ST FLOOR PLAN
A-1.2 2ND AND 3RD FLOOR PLANS
A-2.0 NORTH & WEST ELEVATIONS
A-2.1 SOUTH & EAST ELEVATIONS
A-5.0 WINDOW SCHEDULE
A-5.1 WINDOW SCHEDULE & ELEVATIONS
A-5.2 DOOR SCHEDULE & ELEVATIONS
PRESIDENT'S HOUSE, SMITH COLLEGE
WINDOW & DOOR REPLACMENT
NORTHAMPTON, MA
Smith College
126 West St.
Northampton, MA 01063
Morgan Wilson, Project Manager, Capital Projects
mtwilson@smith.edu
(413) 585-2447
(516) 209-1751 - cell
Kraus Fitch Architects, Inc.
110 Pulpit Hill Road
Amherst, MA 01002
(413) 549-5799
Laura Fitch, AIA, LEED BD-C
413-687-2727 (cell)
lfitch@krausfitch.com KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
Title Page
0.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
Title Page
0.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
ELM
STR
E
E
T
/ RO
U
T
E
9
PARADISE ROADCOLLEGE LANE
FENCED UTILITY COURT
FLAT
PATIO AREA
STUDENT PERMIT
PARKING ALONG
PARADISE ROAD
GARDEN
HEDGESTEEP SLOPE RETAINING WALLGARDEN
FENCEFEN
C
E
FEN
C
E
FENCESTE
E
P
HIL
L
S
I
D
E
W/ SH
R
U
B
S
POSSIBLE STAGING
AREA FOR
CONTRACTOR
STORAGE "BOX"
AND PORTA-POTTY
PARKING FOR LIFT
SITE PLAN
NO SCALE
2
0.0
ELM STRE
E
T
/ ROU
T
E
9
PARADISE ROAD
COLLEGE LANE
LOCUS MAP
NO SCALE
1
0.0
GENERAL CODE SUMMARY:
IEBC:
Work Area Compliance Method: Level 1 (window and door replacement)
Size of Building
Footprint with Porches (exterior): 5,239 SF
Total Finish Interior Square footage (not including basement): 10,045 SF
Uses
Use Group R-3 (Residential Single Family)
Safety Glazing (IBC 2009)
Required in the following locations:
- Glazing adjacent to doors (within 24")- in locations as noted in schedule
- Low panels (within 18" of floor) - NOT APPLICABLE
- Stairways and landings (< 60 inch to sill)- NOT APPLICABLE
Window Sill Requirements (IRC 2009)
In dwelling units where the opening of an operable window is located more than 72 inches
above the finished grade or surface below, the lowest part of the clear opening of the
window shall be a minimum of 24 inches above the finished floor of the room in which the
window is located. Operable sections of windows shall not permit openings that allow
passage of a 4 inch diameter sphere where such openings are located within 24 inches of
the finished floor. - NOT APPLICABLE
Emergency Window Egress Requirements
Not applicable for window replacement.
Stretch Energy Code Requirements
Residential Requirements
- Windows: 0.30 max u-value
- 1/2 lites Doors: 0.27 max u-value
- Full lite Doors: 0.32 max u-value
Commercial Requirements (for energy rebate calucations as building is heated from central
plant).
- Windows: 0.35 max u-value
- 1/2 and full lites Doors: 0.45 max u-value
Codes and Other Sources
2009 International Building Code (IBC)
2009 International Residential Code (IRC)
2012 International Energy Conservation Code (IECC)
Massachusetts Amendments to the IRC 2009
Massachusetts Stretch Energy Code
A-3.0
A-3.0P
A-3.1
A-3.1P
A-3.2
A-3.2P
A-3.3
A-3.4
A-3.5
TYP. EXISTING EXISTING CONDITIONS DOUBLE HUNG
EXISTING CONDITIONS SPLAYED DH FIRST AND SECOND FLOOR
PROPOSED SPLAYED DH FIRST AND SECOND FLOOR
EXISTING CONDITIONS BOWED BAY FIRST FLOOR
PROPOSED BOWED BAY FIRST FLOOR
NEW DH AT IN-SWING CASEMENTS (EXTG AND PROPOSED)
NEW DH AT OUT-SWING CASEMENTS (EXTG AND PROPOSED)
PROPOSED TYPICAL SINGLE HUNG: MARVIN & KOLBE
A-3.6
A-3.7
A-4.0
A-4.1
A-4.2
A-5.0
A-5.1
A-5.2
ATTIC WINDOWS
DOORS: LOGGIA AND STAIR
DOORS: SECOND FLOOR
ARCHED DOORS: SECOND FLOOR
WINDOW SCHEDULE
WINDOW SCHEDULE AND WINDOW TYPE ELEVATIONS
BAY WINDOW SECOND FLOOR (EXISTING AND PROPOSED)
DOOR SCHEDULE AND DOOR ELEVATIONS
DOUBLE WINDOW AT 2ND FLOOR (EXISTING AND PROPOSED)
A-3.8
A-3.9
NEW DH WINDOWS AT LIBRARY BALCONY DOORS
NEW CASEMENT WDWS AT LAUNDRY ROOM DOORS
A-3.10 BASEMENT WINDOWS
A-3.11 GARAGE WINDOWS
A-3.12 GARDENER'S WINDOWS
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
BASEMENT
PLAN
A-1.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
BASEMENT
PLAN
A-1.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
GARDENER'S ROOM
003A
002A
004
HOT WATER TANK ROOM
002
UP
005
UP
008
007
STORAGE AREA
LAUNDRY ROOM
003
ELEV
EXISTING
APPROXIMATE
AREA OF UTILITY
/ MAINTENANCE
YARD
REPLACE EXISTING DOOR
WITH NEW WINDOW,
PANEL BELOW (INSIDE AND
OUTSIDE) BY SITE
CONTRACTOR
REPLACE EXISTING DOOR WITH NEW
WINDOW, PANEL BELOW (INSIDE
AND OUTSIDE) BY SITE CONTRACTOR
REPLACE EXISTING
DOOR WITH NEW
WINDOW, PANEL
BELOW (INSIDE AND
OUTSIDE) BY SITE
CONTRACTOR
REPLACE EXISTING
"Y" WINDOWS
WITH MAPES
PANELS
ADD 1-1
WINE CELLAR HAS
INSULATED SOFFIT
THAT COVERS
WINDOW.
REMOVE AND
REINSTALL AS
NEEDED.
ADD 1-1
CUT MAPES PANEL AS
NEEDED TO
ACCOMMODATE
EXISTING PIPE. REPLUMB
AS NEEDED. SEAL
PENETRATION.
ADD 1-1
PROTECT IT EQUIPMENT
AND PANELS BELOW
AND IN FRONT OF
WINDOWS
ADD 2-10
(MODIFIED BY ADD
3-8): UTILIZE
EXISTING SCREEN
DOOR
ADD 3-8
BASEMENT PLAN
Scale: 1/8" = 1'-0"
1
A-1.0
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
1ST FLOOR
PLAN
A-1.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
1ST FLOOR
PLAN
A-1.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
BUTLERS
PANTRY
WASH
ROOM
GARAGE
106
KITCHEN
PORCH RANGE
REFRIG
105
GUEST
ROOM
110
111
BATH
BREAKFAST
PORCH
DN
DN UP
UP
104 OFFICE
103
102A 101
ROOM
112
DINING
RECEPTION
102
HALL
LOGGIA
ELEV
UP
114
113
ROOM
LIVING
RADIATOR
COVER
RADIATOR
COVER
PREVIOUS
REPLACEMENT
WDW. - INCLUDED
IN CONTRACT
FRONT
DOOR
NIC
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE
INTERIOR
SHUTTERS
WOOD AND S.S.
BACKSPLASH IN
FRONT ON WDW.
CORIAN
BACKSPLASH IN
FRONT ON WDW.
CORIAN
BACKSPLASH IN
FRONT ON WDW.
LOWER
SASH
INTERIOR
SHUTTERS
SUNROOM
DOORS NIC
WITH 20"
TRANSOM PANEL
SUNROOM
DOORS NIC
APPROXIMATE
AREA OF UTILITY/
MAINTENANCE
YARD AT BASEMENT
LEVEL BELOW
REPLACE DOORS
AND SCREENS
DOORSREPLACE EXISTING
FRENCH CASEMENT
WINDOWS WITH NEW
SINGLE HUNG UNITS
KITCHEN DOOR
AND SCREEN - NIC
FIRST FLOOR PLAN
Scale: 1/8" = 1'-0"
1
A-1.1
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
2ND AND 3RD
FLOOR PLANS
A-1.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
2ND AND 3RD
FLOOR PLANS
A-1.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
DN
DN
UPUP
DN
OPEN
TO
BELOW
ROOF
DECK
Washer
Dryer
LIBRARY
208
SITTING ROOM
207
GUEST BEDROOM
209
Kitchenette/Laundry
212
GUEST BEDROOM
206
PRIVATE STUDY
205
MASTER BEDROOM
201
MASTER BATHROOM
203204
202
ELEV
215HALLWAY
210
211
GUEST BEDROOM
214213
INTEGRAL
RADIATOR
COVER
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE INTERIOR
SHUTTERS
AND RADIATOR
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE
INTERIOR
SHUTTERS
AND
RADIATOR
DOUBLE
INTERIOR
SHUTTERS
DOUBLE
INTERIOR
SHUTTERS
INTEGRAL
BOOK CASE
INTERIOR SHUTTERS
AT BOTTOM SASH
INTERIOR SHUTTERS
AT BOTTOM SASH
RADIATOR COVER,
BELOW SILL
RADIATOR COVER,
BELOW SILL
22" DEEP
BALCONY
EXISTING STORM
SCREEN COMBO
EXISTING STORM
SCREEN COMBO
EXISTING STORM
SCREEN COMBO
EXISTING STORM
SCREEN COMBO
32" HIGH RAD.
BETWEEN UNITS
GUTTER CONFLICT AT THIS WINDOW,
(REMOVE GUTTER AND ADJUST AS
NEEDED IF FACTORY-APPLIED
CASINGS)
REPLACE EXISTING
DOORS WITH NEW DH
WINDOWS, PANEL
BELOW (INSIDE AND
OUTSIDE) BY SITE
CONTRACTOR
REPLACE EXISTING FRENCH CASEMENT
WINDOWS WITH NEW SINGLE HUNG UNITS
REPLACE EXISTING CENTER FRENCH CASEMENT
WINDOWS WITH NEW FIXED PICTURE UNITSREVERSE SWING OF
NEW DOORS AND
ADD NEW SLIDING
SCREEN DOORS.
RAISE SILL 1".
REPAIR FLASHINGS.
2 STEPS UP
TO DOOR
REMOVE EXISTING
NARROW BALCONY,
REPAIR STUCCO.
ADD 1-2
NEW SWINGING
SCREEN DOOR
ADD 1-2
TEMPERED GLASS PER SCHEDULE
SECOND FLOOR PLAN
Scale: 1/8" = 1'-0"
1
A-1.2
303
STORAGE
302
BATHROOM
305
301
3'-4"
TYPL DORMER
2'-6"REMOVE
EXISTING STORM
SCREEN COMBO
ALL ATTIC
WINDOWS
EXISTING SKYLIGHT TO
BE REMOVED IN
SEPARATE CONTRACT
THIRD FLOOR PLAN
Scale: 1/8" = 1'-0"
2
A-1.2
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
NORTH & WEST
ELEVATIONS
A-2.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
NORTH & WEST
ELEVATIONS
A-2.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
NIC
INTERIOR LINE OF WALK TO FRONT DOOR,
IN FRONT OF BUILDINGHALLWAY
DASHED LINE
OF GARAGE,
IN FRONT
REPLACE ARCHED
DOOR WITH SIMILAR
DOOR WITH LARGER
LITE.
NEW FRAMES WITH MAPES
PANELS IN THREE (3)
BASEMENT WINDOWS
REPLACE INSWING
AWNING WITH SLIDING
FIBERGLASS UNITS, TYP.
REPLACE ALL SHUTTERS. REMOVE ALL
EXISTING PLATE PINTELS, HINGES AND
S-HOLDBACKS, AND REPLACE WITH NEW
PORCH BEHIND GARAGE
KITCHEN DOOR N.I.C.
NIC
NORTH ELEVATION - PROPOSED
Scale: 1/8" = 1'-0"
1
A-2.0
DASHED LINE
OF GARAGE,
IN FRONT
REPLACE ARCHED
DOOR WITH SIMILAR
DOOR WITH LARGER
LITE.
STONE
STUCCO
REPLACE DOOR
WITH WINDOW
AND PANEL
NORTH GARAGE ELEVATION - PROPOSED
Scale: 1/8" = 1'-0"
2
A-2.0
NIC
REPLACE INSWING
AWNING WITH SLIDING
FIBERGLASS UNITS, TYP.
REPLACE ALL SHUTTERS.
REMOVE ALL PLATE
PINTELS, HINGES AND
S-HOLDBACKS, AND
REPLACE WITH NEW
WEST ELEVATION - PROPOSED
Scale: 1/8" = 1'-0"
3
A-2.0
REPLACE FRENCH
CASEMENT @
MASTER
BEDROOM WITH
DH WINDOW
REPLACE FRENCH
CASEMENT@
GUEST BEDROOM
206 WITH DH
WINDOW
REPLACE FRENCH
CASEMENT @
MASTER
BEDROOM WITH
DH WINDOW
REPLACE FRENCH
CASEMENT@
GUEST BEDROOM
206 WITH DH
WINDOW
REPLACE FRENCH
CASEMENT @
MASTER
BEDROOM WITH
DH WINDOW
REPLACE FRENCH
CASEMENT@
GUEST BEDROOM
206 WITH DH
WINDOW
REPLACE FRENCH
CASEMENT @
MASTER
BEDROOM WITH
DH WINDOW
REPLACE FRENCH
CASEMENT@
GUEST BEDROOM
206 WITH DH
WINDOW
WEST AND EAST ELEVATIONS INSIDE LOGGIA - PROPOSED
Scale: 1/8" = 1'-0"
4
A-2.0
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
SOUTH & EAST
ELEVATIONS
A-2.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
SOUTH & EAST
ELEVATIONS
A-2.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
BREAKFAST PORCH NIC
DEMO LIBRARY BALCONY,
REPAIR SURFACE AS NEEDED
REPLACE FRENCH
CASEMENT @
MASTER
BEDROOM WITH
DH WINDOW
REPLACE DOOR & SIDELIGHTS @ LAUNDRY WITH
FRENCH CASEMENT AND PANEL BELOW
REPLACE FRENCH CASEMENTS @ FIRST
FLOOR GUEST ROOM WITH DH WINDOWS
REPLACE WINDOWS,
TEMPERED GLASSFIELD APPLIED "CAPITALS" AND BASES TO SIMULATE
REMOVED CASINGS
REPLACE CENTER FRENCH CASEMENT @ MASTER BEDROOM AND GUEST BEDROOM 206
WITH SINGLE FIXED WINDOW, MUNTIN SPACING TO MATCH DH WINDOWS AT SIDES
REPLACE DOORS @ LIBRARY WITH
DH WINDOWS AND PANELS
ADD FLASHINGS AT BASE OF EXTERIOR PANELS, SEE
REPAIR FLASHING AT DOOR
THRESHOLD/BALCONY INTERFACE
SOUTH ELEVATION - PROPOSED
Scale: 1/8" = 1'-0"
1
A-2.1
NIC
REPLACE DOOR & SIDELIGHTS @ LAUNDRY WITH
FRENCH CASEMENT AND PANEL BELOW
STUCCO
STONE
REMOVE S-HOLDS FROM
PREVIOUS SHUTTERS;
TOUCH UP STUCCO &
FINISH AS NEEDED
SOUTH ELEVATION - PROPOSED
Scale: 1/8" = 1'-0"
2
A-2.1
SASH POCKET APPROX. 4 1/8"
BRICK OR STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING
EXISTING FRAME
EXISTING JAMB
EXISTING STOP: 1/2" X
2.5" (SCREW ATTACHED)
PAINTED WOOD SASH
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP. SOME
WINDOWS HAVE EXISTING
STORM/SCREEN COMBINATION
UNITS MOUNTED ON EXTERIOR.
PROPABLE CONDITIONS AT
COUNTER WEIGHTS: SEPARATED
BY ZINC METAL STRIP.
NOTE: HEADS HAVE SIMILAR
VOIDS WITH NO WEIGHTS.
LINE OF PLASTER
4 1/2" +/-10 1/2" +/- SILL1'-9" +/- RADIATOR COVER5" +/-3 1/4" +/-1 7/8" +/-
INTERIOR SHUTTERS IN
SOME LOCATIONS
EXISTING JAMB (HEAD SIMILAR)
Scale: 3" = 1'-0"
EX-4
A-3.0
TYPICAL EXISTING WINDOW UNIT WITH INTERIOR CASING REMOVED
SASH
WEIGHT
SASH CORD
VOID
ROUGH OPENING
GAP (1/4" - 1/2")
SASH
SILL
SASH WEIGHT
SHEET METAL SEPARATOR
ROUGH OPENING GAP
1" THICK JAMB
3/4" FRAME
VOID
1" EXTERIOR CASING
1" INTERIOR CASING
PARTING STRIP
SASH
FACE OF BRICK MASONRY
SASH STOP
JAMB DETAIL: TYPICAL EXISTING WINDOW UNIT
TYPICAL EXISTING CONDITIONS - DOUBLE HUNG UNITS
SASH POCKET
APPROX. 4 1/8"
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
SLOPED, PAINTED WOOD
SILL
EXTERIOR CASING & SASH
STOP EXISTING STOP: 1/2" X
2.5" (SCREW ATTACHED)
EXISTING PARTING STRIP
3" +/-2 1/2" +/-10 1/2" +/- SILL
1'-9" +/- RADIATOR COVER
1 3/8" +/-EXISTING SILL
Scale: 3" = 1'-0"
EX-3
A-3.0 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
TYP. EXISTING
CONDITIONS
DOUBLE HUNG
A-3.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
TYP. EXISTING
CONDITIONS
DOUBLE HUNG
A-3.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
KOLBE - ULTRA SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
PROP. TYP. SH
KOLBE
A-3.0P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
PROP. TYP. SH
KOLBE
A-3.0P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
TYPICAL SINGLE
HUNG WINDOW
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
16. INTERIOR
SHUTTERS
3/16"
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
2. PREVIOUS WEIGHT
POCKET
9. NEW WINDOW
11. EXTERIOR CASING, 3 SIDES
3"+/-
13. CAULK JOINT
8. PEEL & STICK
17. BLINDS
1/2"1 1/2"2"
15. INSTALL SHUTTERS STRAP HINGES TO BE LOCATED
SO THATWINDOW OVERLAPS
M.O. AS SHOWN, SHUTTER
WILL NOT BE OPERABLE
1/2" OVERLAP @ MASONRY OPENING
PROPOSED JAMB (HEAD SIMILAR)
Scale: 3" = 1'-0"
2-K
A-3.0P
4" +/-
4. SASH STOP & NEW TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH
SILL
8. PEEL & STICK
PROPOSED SILL
Scale: 3" = 1'-0"
1-K
A-3.0P
16. INTERIOR
SHUTTERS
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
2. PREVIOUS WEIGHT
POCKET
9. NEW WINDOW
11. EXTERIOR CASING, 3 SIDES 3/16"
3" +/-
13. CAULK JOINT
8. PEEL & STICK
17. BLINDS
1/2"1 1/2"2"
15. INSTALL SHUTTERS STRAP HINGES TO BE LOCATED
SO THATWINDOW OVERLAPS
M.O. AS SHOWN, SHUTTER
WILL NOT BE OPERABLE
1/2" OVERLAP @ MASONRY OPENING
PROPOSED JAMB (HEAD SIMILAR)
Scale: 3" = 1'-0"
2-M
A-3.0P
4 1/8" +/-
4. SASH STOP & NEW TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH
SILL
8. PEEL & STICK
PROPOSED SILL
Scale: 3" = 1'-0"
1-M
A-3.0P
MARVIN- NEXT GEN.
FULL FRAME
SASH POCKET APPROX. 4 1/8"
TYPE I - FIRST FLOOR SPLAYED
STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING
EXISTING FRAME
EXISTING JAMB
EXISTING STOP: 1/2" X 2"
(SCREW ATTACHED)
PAINTED WOOD SASH
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
2 1/4" +/-2 1/4" +/-2" +/-1 1/2" +/-EXTERIOR STOP
PROPABLE CONDITIONS AT
COUNTER WEIGHTS: SEPARATED
BY ZINC METAL STRIP.
NOTE: HEADS HAVE SIMILAR
VOIDS WITH NO WEIGHTS.
LINE OF PLASTER
1 1/4" +/-1'-4 3/4" +/- RECESS / RADIATOR COVER2'-9" +/- STOP TO STOP DIM
SECOND FLOOR
3'-1" +/-
FIRST FLOOR TO POINT OF TEAR BA
4'-0" +/- FULL SPLAYED OPENING
SECOND FLOOR
SHUTTER PIN - SOME UNITS
3'-9 1/4" +/- MASONRY OPENING
FIRST AND SECOND FLOORS
EXISTING CONDITIONS: JAMB
Scale: 3" = 1'-0"
EX-2
A-3.1
SASH POCKET
APPROX. 4 1/8"
SPLAYED SIDE WALLS,
BEYOND
INTERIOR WOOD SILL,
PAINTEDSLOPED, PAINTED WOOD
SILL
EXTERIOR CASING & SASH
STOP
EXISTING PARTING STRIP
FIELD DETERMINE
3" +/-10 1/2" +/- SILL
EXISTING STOP: 1/2" X
2.5" (SCREW ATTACHED)
RADIATOR COVER
EXISTING CONDITIONS: SILL @ RADIATOR COVER
Scale: 3" = 1'-0"
EX-1A
A-3.17'-2" +/- MASONRY OPENINGFIRST FLOOR2 1/4" +/-2 1/4" +/-6'-8"+/- TRIMMED OPENING FIRST FLOOR1 1/2" +/-5'-4 1/2"+/- TRIMMED OPENING SECOND FLOOR5'-10" ?????? +/- MASONRY OPENINGFIRST FLOOREXISTING CONDITIONS: HEAD
Scale: 3" = 1'-0"
EX-3
A-3.1
SPLAYED SIDE WALLS,
BEYOND
INTERIOR WOOD SILL
OR STOP, PAINTED10 1/2" +/- SILL
PANEL BELOWSASH POCKET
APPROX. 4 1/8"
EXISTING CONDITIONS: SILL @ PANEL
Scale: 3" = 1'-0"
EX-1
A-3.1 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
SPLAYED DH
FIRST AND
SECOND FLOOR
A-3.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
SPLAYED DH
FIRST AND
SECOND FLOOR
A-3.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016TYPICAL SPLAYED DOUBLE HUNG
WINDOW IN VERY THICK WALLS
- 1ST AND SECOND FLOORS
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
PROP. SPLAYED
DH FIRST AND
SECOND FLOOR
A-3.1P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
PROP. SPLAYED
DH FIRST AND
SECOND FLOOR
A-3.1P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
PROPOSED SPLAYED DOUBLE HUNG
WINDOW - 1ST AND 2ND FLOORS
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
8. PEEL & STICK
2. PREVIOUS WEIGHT
POCKET
13. CAULK JOINT
9. NEW WINDOW
11. EXTERIOR CASING, 3 SIDES
3/16"
15. INSTALL SHUTTERS
1/2"1 1/2"2"
JAMB
Scale: 3" = 1'-0"
4
A-3.1P
9. NEW WINDOW
12. FRAME
EXPANDER
7. REFINISH SILL
4. SASH STOP & NEW TRIM
10. SHIM SPACE
6. FOAM CAVITIES
14. EXISTING SILL
SILL
Scale: 3" = 1'-0"
2
A-3.1P3/16"4. SASH STOP & NEW TRIM
10. SHIM SPACE
3. INTERIOR TRIM
8. PEEL & STICK
INSTALL NEW BACKER ROD AND
CAULK JOINT, MAINTAIN A MIN
OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
EXTERIOR CASING: VERIFY DISTANCE
TO M.O. IS SIMILAR TO JAMBS AND
THAT SAME CASING CAN BE
INSTALLED AT 3 SIDES. CUT BACK
EXISTING FRAME IF NEEDED TO
MAINTAIN UNIFORM CAULK JOINT.
9. NEW WINDOW
HEAD
Scale: 3" = 1'-0"
3
A-3.1P
14. EXISTING SILL
4. SASH STOP & NEW
TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH SILL
PANEL BELOW WINDOW
SILL
Scale: 3" = 1'-0"
1
A-3.1P
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
ADD1-3, ADD2-12 and ADD3-10
14.
15.
16.
17.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
INTERIOR
WD. TRIM
EXISTING
PAINTED SASH
STOP
1'-0" +/-2"
PAINTED WOOD SASH
INTERIOR WOOD TRIM,
PAINTED
4" +/
-
EXTERIOR WD.
TRIM (PILASTER)
NOTE:
CONDITIONS
BEHIND FRAME
ARE UNKNOWN
NO LONGER OPERABLE
HINGED SASH, PAINTED
OR SCREWED IN PLACE
EXISTING SASHES
MAY BE BUTTED,
OVERLAPPED, OR
COVERED WITH
TRIM.
INTERIOR
WD. TRIM /
STOP
EXISTING PAINTED STOP
PANEL AT SIDES
EXISTING CONDITIONS: JAMB AND MULLION
Scale: 3" = 1'-0"
1
A-3.2
INTERIOR WOOD SILL,
PAINTEDSLOPED, PAINTED
WOOD SILL
EXTERIOR CASING & SASH
STOP
2" +/-1'-5" +/- CURVING RADIATOR COVER / S
EXISTING STOP /
INTERIOR TRIM
RADIATOR COVER
+/- WOOD FRAMED WALL UNDER BAY5 1/2" +/-
EXISTING CONDITIONS: SILL
Scale: 3" = 1'-0"
EX-2
A-3.2
INTERIOR WOOD SILL,
PAINTED
VALANCE FOR
CURTAINS
6'-6"+/- TRIMMED OPENING 6'-7" +/- ROUGH OPENINGCEILING
EXISTING CONDITIONS: HEAD
Scale: 3" = 1'-0"
EX-3
A-3.2 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BOWED BAY
FIRST FLOOR
- EXISTING CONDS.
A-3.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BOWED BAY
FIRST FLOOR
- EXISTING CONDS.
A-3.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
EXISTING CONDITIONS
(15' TO LEFT FOR COPYING)
BRICK SILL
BRICK TO GRADE
PILASTER BEYOND
CURVING WOOD BASE
TRIM, PAINTED
CURVING WOOD PANEL,
PAINTED
EXISTING CONDITIONS: PANEL BASE
Scale: 3" = 1'-0"
EX-1
A-3.2
EXISTING CONDITIONS
TYPICAL BOWED BAY - 1ST FLOOR
EXISTING CONDITIONS
(15' TO LEFT FOR COPYING)
CAULK JOINT
INSTALL FACETED OR CURVED COPPER
FLASHING WITH DRIP EDGE OVER
CURVED BRICK SILL
COUNTER FLASHING AND INSULATION:
- CAREFULLY REMOVE CURVED BASE TRIM AND PANEL STILES.
- REMOVE OR CUT PANEL BOARDS BEHIND TO INSTALL COUNTER
FLASHING.
- WHILE BASE OF WALL IS OPEN, EXAMINE CAVITY AND DETERMINE IF
DENSE PACK CELLULOSE CAN BE INSTALLED.
- REINSTALL EXISTING PANEL BOARDS. REPLACE ANY ROTTEN PIECES
WITH FULLY BACK-PRIMED NEW BOARDS TO MATCH.
- SEAL ANY GAPS IN SHEATHING
- SCRAPE AND PAINT
BASE OF PANEL
Scale: 3" = 1'-0"
1
A-3.2P
1'-0" +/-2"
4"
+/
-
NEW P.T. EXTERIOR
STOP
WRAP NEW STOP WITH
BREAK METAL BACK TO
PILASTER, CAULK.
1'-1
0
1/2
"
+/-
NE
W
W
O
O
D
. CL
A
D
SA
S
H
(N
O
FR
A
M
E
)
APPROXIMATE LINE OF
EXISTING CURVED SILL
TO BE SCRAPED AND
PAINTED.
NEW P.T. STUD, CUT TO KEEP
NEW BREAK METAL MULL
COVER ALIGNED WITH EDGE
OF EXTERIOR SILL. SECURE
POST WITH PLATE AT SILL AND
HEAD. COVER IN PEAL AND
STICK.
MULL COVER -
CONFIRM IF THIS CAN
BE CLIPPED INTO SASH
NEW P.T. EXTERIOR
STOPS
WEATHERSEAL EDGE OF
SASH WITH SILICONE
CAULKING OR
NON-EXPANDING FOAM
EXISTING TRIM TO
REMAIN. REPLACE
STOP AT BOTH SIDES.
EXISTING TRIM/STOP.
CUT AND/OR REPLACE
AS NEEDED. REMOVE
STOP TO ASSESS
CAVITIES BEYOND
WRAP EXISTING FRAME
WITH PEAL AND STICK
EXISTING TRIM/STOP.
CUT AND/OR REPLACE
AS NEEDED. REMOVE
STOP TO ASSESS
CAVITIES BEYOND
FOAM CAVITIES
AS POSSIBLE.
FOAM CAVITIES
AS POSSIBLE.
JAMB AND MULLION
Scale: 3" = 1'-0"
4
A-3.2P
PEAL AND STICK
SMALL TRIM TO BRIDGE
BETWEEN EXISTING CASEWORK
AND NEW SILL
EXISTING WOOD SILL
TO BE SCRAPED AND
PAINTED
FRAME EXPANDER
FROM SASH TO SILL
NEW SASH INSTALLED JUST ABOVE
THE PLANE OF THE SILL
P.T. SILL AS NEEDED, CUT TO FIT CURVE
OF EXISTING SILL. NEW SASH CAN
OVERLAP THE EXISTING INTERIOR SILL
(DIFFERENCE BETWEEN NEW STRAIGHT
SASH, AND FORMER CURVED SASH)
NEW SILICON CAULKING AND
NON-EXPANDING FOAM
SILL
Scale: 3" = 1'-0"
2
A-3.2P
PEAL AND STICK
SMALL TRIM TO BRIDGE
BETWEEN EXISTING CASEWORK
AND NEW SILL
EXISTING WOOD TRIM
TO BE SCRAPED AND
PAINTED
NEW EXTERIOR STOP
WRAPPED IN BREAK
METAL
NEW SASH INSTALLED JUST UNDER
THE PLANE OF THE EXISTING HEAD
TRIM
NEW SILICON CAULKING AND
NON-EXPANDING FOAM
P.T. BLOCKING AS NEEDED, CUT TO FIT
CURVE OF EXISTING FRAME. NEW SASH
CAN OVERLAP THE EXISTING HEAD
TRIM (DIFFERENCE BETWEEN NEW
STRAIGHT SASH, AND FORMER CURVED
SASH)
INSTALL NEW HEAD
FLASHING
HEAD
Scale: 3" = 1'-0"
3
A-3.2P SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BOWED BAY
FIRST FLOOR
- PROPOSED
A-3.2P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BOWED BAY
FIRST FLOOR
- PROPOSED
A-3.2P KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
TYPICAL BOWED BAY - 1ST FLOOR
6 1/2" +/-
INTERIOR
WD. TRIM
EXTERIOR MULL COVER
EXISTING CONDITIONS: JAMB
Scale: 3" = 1'-0"
EX-3
A-3.3 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DOUBLE WINDOW
AT
SECOND FLOOR
A-3.3 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DOUBLE WINDOW
AT
SECOND FLOOR
A-3.3 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
SASH POCKET APPROX. 4 1/8"
BRICK OR STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING
EXISTING FRAME
EXISTING JAMB
EXISTING STOP: 1/2" X
2.5" (SCREW ATTACHED)
PAINTED WOOD SASH
INTERIOR WOOD SILL,
PAINTED
2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP
PROPABLE CONDITIONS AT
COUNTER WEIGHTS: SEPARATED
BY ZINC METAL STRIP.
NOTE: HEADS HAVE SIMILAR
VOIDS WITH NO WEIGHTS.
LINE OF PLASTERVARIES +/- SILLSHUTTER MOUNTED TO
STOP
INTERIOR WOOD TRIM,
PAINTED
1 7/8" +/-EXISTING CONDITIONS: JAMB
Scale: 3" = 1'-0"
EX-2
A-3.33/16"3. INTERIOR
TRIM
8. PEEL & STICK
REMOVE WEIGHTS. CUT
OPEN OR DRILL WEIGHT
POCKETS FROM
EXTERIOR. INSTALL
NEW P.T. BLOCKING
ONLY IF NEEDED
EXTERIOR MULL
CASING (FIELD OR
FACTORY APPLIED)
TO BE PROVIDED BY
WINDOW
MANUFACTURER.
3/16"
4. SASH STOP & NEW
TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
9. NEW WINDOW
16. INTERIOR
SHUTTERS
JAMB
Scale: 3" = 1'-0"
3
A-3.3
14. EXISTING SILL
6. FOAM CAVITIES
4. SASH STOP & NEW
TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH SILL
16. INTERIOR SHUTTERS
SILL
Scale: 3" = 1'-0"
1
A-3.3
3" +/-
REMOVE WEIGHTS. CUT
OPEN OR DRILL WEIGHT
POCKETS FROM
EXTERIOR. INSTALL
NEW P.T. BLOCKING
ONLY IF NEEDED
3/16"
4. SASH STOP & NEW
TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
8. PEEL & STICK
2. PREVIOUS WEIGHT
POCKET
6. FOAM CAVITIES
13. CAULK JOINT
9. NEW WINDOW
11. EXTERIOR
CASING, 3 SIDES
3" +/-
16. INTERIOR
SHUTTERS
JAMB
Scale: 3" = 1'-0"
2
A-3.3
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BAY WINDOW
SECOND FLOOR
A-3.4 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BAY WINDOW
SECOND FLOOR
A-3.4 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
SASH POCKET APPROX. 4 1/8"
EXISTING STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING - "PILASTER"
EXISTING FRAME
EXISTING JAMB
EXISTING STOP: 1/2" X 3"
(SCREW ATTACHED)
PAINTED WOOD SASH
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
4 1/2" +/-
EXTERIOR STOP
PROPABLE CONDITIONS AT
COUNTER WEIGHTS: SEPARATED
BY ZINC METAL STRIP.
NOTE: HEADS HAVE SIMILAR
VOIDS WITH NO WEIGHTS.
LINE OF PLASTER
BOOKCASE IN SOME
LOCATIONS 5"+/-EXISTING JAMB
Scale: 3" = 1'-0"
EX-2
A-3.4
EXTERIOR CASING - "PILASTER"
7 3/4" +/-5" +/-INTERIOR WD.
TRIM
PAINTED WOOD
FRENCH
OUT-SWING
CASEMENT SASH
8" +/-EXTERIOR CASING - "PILASTER"
DASHED LINES
OF BLINDS AT
HEAD CASING
EXISTING MULLION
Scale: 3" = 1'-0"
EX-3
A-3.4
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
2. PREVIOUS WEIGHT
POCKET
6. FOAM CAVITIES
13. CAULK JOINT
9. NEW WINDOW
3/16"
FIELD-APPLIED DECORATIVE
CASINGS (PAINTED,
COMPOSITE MATERIAL).
SK1A
8. PEEL & STICK
PROPOSED JAMB
Scale: 3" = 1'-0"
2
A-3.4
14. EXISTING SILL
4. SASH STOP & NEW TRIM
9. NEW WINDOW 8. PEEL & STICK
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH
SILL
6. FOAM CAVITIES
PROPOSED SILL
Scale: 3" = 1'-0"
1
A-3.44. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
9. NEW WINDOW
FIELD-APPLIED DECORATIVE
CASINGS (PAINTED,
COMPOSITE MATERIAL).
17. BLINDS 3/16"3/16"
NEW PICTURE UNIT AT
LOCATION OF FORMER
FRENCH CASEMENT
ADD BLOCKING AS NEEDED
AND INSULATE ANY
CAVITIES
CUT EXISTING FRAME
AS NEEDED
SK-1
PROPOSED MULLION
Scale: 3" = 1'-0"
3
A-3.4
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
FIELD APPLIED CASING, INSTALL
OVER ALUMINUM EXTENSION
JAMBS
WINDOW ELEVATION
Scale: 1/4" = 1'-0"
4
A-3.4
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DH AT FORMER
IN-SWING
FRENCH CSMNTS
A-3.5 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DH AT FORMER
IN-SWING
FRENCH CSMNTS
A-3.5 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
BRICK OR STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING
UNKNOWN CONDITIONS BEHIND
FRAME - POSSIBLY FORMER DH
WEIGHT POCKETS
PAINTED WOOD FRENCH
CASEMENT SASH
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
4 1/4" +/-
LINE OF PLASTER 4 1/2" +/-5" +/-5" +/- EXISTING INTERIOR SCREEN
DASHED LINE OF
BLINDS AT HEAD
CASING
EXISTING JAMB
Scale: 3" = 1'-0"
EX-2
A-3.5
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
SLOPED, PAINTED WOOD
SILL
3" +/-EXISTING SILL
Scale: 3" = 1'-0"
EX-1
A-3.5
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
8. PEEL & STICK
DETERMINE IF THERE IS
A CAVITY. EXISTING
CASEMENTS WOULD
NOT HAVE WEIGHTS.
DRILL FRAME AND
FOAM.
13. CAULK JOINT
9. NEW WINDOW
11. EXTERIOR
CASING, 3 SIDES
3/16"
CUT FRAME AS NEEDED TO
ENABLE NEW DOUBLE HUNG
WINDOW TO SIT CLOSER TO M.O.
THAN PREVIOUS CASMENT UNIT,
TO MAINTAIN SAME EXTERIOR
CASINGS AS OTHER
INSTALLATIONS.
14. EXISTING SILL
4. SASH STOP & NEW TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH
SILL
CUT FORMER CASEMENT FRAME
/ SILL AS NEEDED TO ENABLE
NEW DOUBLE HUNG WINDOW
TO SIT CLOSER SUB SILL, IN
SIMILAR RELALTIONSHIP AS
OTHER LOCATIONS.
6. FOAM CAVITIES
PROPOSED SILL
Scale: 3" = 1'-0"
1
A-3.5
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DH AT FORMER
OUT SWING
FRENCH CSMNTS
A-3.6 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DH AT FORMER
OUT SWING
FRENCH CSMNTS
A-3.6 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
BRICK OR STUCCO ON BRICK
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING
UNKNOWN
CONDITIONS
BEHIND FRAME -
POSSIBLY
FORMER DH
WEIGHT
POCKETS
PAINTED WOOD FRENCH
CASEMENT SASH
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
2 1/2" +/-2" +/-2" +/-3 3/4" +/-EXTERIOR STOP
LINE OF PLASTER
4 1/2" +/-10 1/2" +/- SILL1'-9" +/- RADIATOR COVER5" +/-3 1/4" +/-5" +/- EXISTING INTERIOR SCREEN
LINE OF BLINDS AT
HEAD CASING
EXISTING JAMB
Scale: 3" = 1'-0"
EX-2
A-3.6
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
SLOPED, PAINTED WOOD
SILL
EXTERIOR CASING & SASH
STOP EXISTING STOP: 1/2" X
2.5" (SCREW ATTACHED)
EXISTING PARTING STRIP
??????? +/-3" +/-1'-9" +/- RADIATOR COVER
EXISTING SILL
Scale: 3" = 1'-0"
EX-1
A-3.6
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
8. PEEL & STICK
DETERMINE IF THERE IS
A CAVITY. EXISTING
CASEMENTS WOULD
NOT HAVE WEIGHTS.
DRILL FRAME AND
FOAM.
13. CAULK JOINT
9. NEW WINDOW
11. EXTERIOR
CASING, 3 SIDES
3/16"
3" +/-
CUT FRAME AS NEEDED TO
ENABLE NEW DOUBLE HUNG
WINDOW TO SIT CLOSER TO M.O.
THAN PREVIOUS CASMENT UNIT,
TO MAINTAIN SAME EXTERIOR
CASINGS AS OTHER
INSTALLATIONS.
14. EXISTING SILL
4. SASH STOP & NEW TRIM
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
7. REFINISH
SILL
CUT FORMER CASEMENT FRAME
/ SILL AS NEEDED TO ENABLE
NEW DOUBLE HUNG WINDOW
TO SIT CLOSER SUB SILL, IN
SIMILAR RELALTIONSHIP AS
OTHER LOCATIONS.
6. FOAM CAVITIES
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
PAINTED WOOD CORNER BOARD
SLOPED, PAINTED WOOD SILL
EXTERIOR CASING & SASH STOP
LINE OF PLASTER AT
NARROW DORMER
PAINTED WOOD SASH
INTERIOR WOOD SILL,
PAINTED
SASH POCKET
APPROX. 3 1/2";
CONFIRM IN FIELD
EXISTING FRAME
EXISTING JAMB
EXISTING STOP:
1/2" X 2.5" (SCREW
ATTACHED)
PROPABLE CONDITIONS AT
COUNTER WEIGHTS: SEPARATED
BY ZINC METAL STRIP.
NOTE: HEADS HAVE SIMILAR
VOIDS WITH NO WEIGHTS.
INTERIOR WOOD TRIM,
PAINTED
EXISTING JAMB - ATTIC
Scale: 3" = 1'-0"
EX-2
A-3.7
SASH POCKET
APPROX. 3 1/2"
INTERIOR WOOD TRIM,
PAINTED
INTERIOR WOOD SILL,
PAINTED
ALUM. STORM WINDOW
TRACK
EXTERIOR CASING & SASH
STOP EXISTING STOP: 1/2" X
1.75 (SCREW ATTACHED)3" +/-EXISTING PARTING STRIP
SLOPED, PAINTED WOOD
SILL
SLATE ROOF
EXISTING SILL
Scale: 3" = 1'-0"
EX-1
A-3.7 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
ATTIC WINDOW
A-3.7 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
ATTIC WINDOW
A-3.7 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
3/16"
4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
2. PREVIOUS WEIGHT
POCKET
6. FOAM CAVITIES
9. NEW WINDOW
13. CAULK JOINT
8. PEEL & STICK
17. BLINDS
REPLACE CASINGS WITH FLAT,
PICTURE FRAMED COMPOSITE TRIM
14. EXISTING SILL
4. NEW TRIM
9. NEW WINDOW
12. FRAME EXPANDER
10. SHIM SPACE
1. REMOVE STORMS
COVER WOOD SUBSILL WITH
ALUM BRAKE METAL. THIS
IS PART OF BASE BID FOR
ATTIC LEVEL WINDOWS.
CLARIFICATION: ALUMINUM
BREAK METAL TO BE
PROVIDED AND INSTALLED
UNDER SECTION 06060.
COLOR: WHITE
ADD2-13
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
LIBRARY
DOOR TO
WINDOW
A-3.8 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
LIBRARY
DOOR TO
WINDOW
A-3.8 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
6. FOAM CAVITIES
13. CAULK JOINT
3. INTERIOR
TRIM
NEW SASH STOP
10. SHIM SPACE
NEW INTERIOR
WOOD TRIM
3/16"
17. BLINDS
EXISTING DOOR FRAME,
COVERED IN PLACE
8. PEEL & STICK
11. EXTERIOR CASING,
3 SIDES
9. NEW WINDOW
6. FOAM CAVITIES
NEW INTERIOR WOOD
PANELING, MATCH
PROPORTIONS TO
PANELS IN ADJACENT
ROOM, PAINT.
NEW INSULATED
STUD WALL.
EXISTING DOOR THRESHOLD, REMOVE
OR CUT TO COVER IN PLACE
NEW PAN FLASHING 1'-0" AT TYPE W 2'-0" AT TYPE ZCONTINOUS AIR
BARRIER AT EXTERIOR
SIDE OF SHEATHING,
PEEL AND STICK TAPED
AT BOTTOM EDGE AND
CORNERS.
LIBRARY DOOR TO WINDOW
EXISTING DOOR FRAME,
COVERED IN PLACE
6. FOAM CAVITIES
13. CAULK JOINT
3. INTERIOR
TRIM
NEW INTERIOR WOOD
PANELING, MATCH
PROPORTIONS TO PANELS IN
ADJACENT ROOM.
MATCH FACTORY
CASINGS WITH
COMPOSITE
MATERIAL,
PAINTED
CONTINOUS AIR
BARRIER AT EXTERIOR
SIDE OF SHEATHING,
PEEL AND STICK TAPED
AT EDGES AND SEAMS.
NEW INSULATED STUD
WALL.
3/16"4. SASH STOP &
NEW TRIM
10. SHIM SPACE
3. INTERIOR
TRIM
8. PEEL & STICK
INSTALL NEW BACKER ROD AND
CAULK JOINT, MAINTAIN A MIN
OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
9. NEW WINDOW
EXTERIOR CASING. FIELD OR
FACTORY APPLIED.
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
NEW PAINTED WOOD
INTERIOR SILL
9. NEW WINDOW W/
TEMPERED LOWER SASH AT
TYPE W
12. FRAME
EXPANDER
10. SHIM SPACE
NEW INTERIOR WOOD
PANELING, MATCH
PROPORTIONS TO
PANELS IN ADJACENT
ROOM, PAINT.
NEW INSULATED
STUD WALL.
NEW PAN FLASHING
NEW SILL, COMPOSITE
MATERIAL, PAINTED
1'-0" AT TYPE W 2'-0" AT TYPE ZCONTINOUS AIR
BARRIER AT EXTERIOR
SIDE OF SHEATHING,
PEEL AND STICK TAPED
AT BOTTOM EDGE AND
CORNERS.
ADD 1-5
ADD 1-5
SEE PHOTOS PROVIDED BY ADD2-14 FOR INTENT
OF WOOD PANEL MATCH
NEW INTERIOR
WOOD
PANELING,
MATCH
PROPORTIONS
TO PANELS IN
ADJACENT
ROOM, PAINT.
NEW
INSULATED
STUD WALL.
EXISTING SLOPED
CONCRETE DOOR
THRESHOLD 2'-0"NEW P.T. BUCKS WITH
TWO BEADS OF
SEALANT
CONTINOUS AIR BARRIER
AT EXTERIOR SIDE OF
SHEATHING, PEEL AND
STICK TAPED AT BOTTOM
EDGE AND CORNERS.
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
LAUNDRY
DOOR TO
WINDOW
A-3.9 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
LAUNDRY
DOOR TO
WINDOW
A-3.9 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
13. CAULK JOINT
NEW INTERIOR WOOD
PANELING, MATCH
PROPORTIONS TO PANELS ON
2ND FLOOR.
PAINTED
COMPOSITE OR
RUBBER CASINGS
(MATCH FACTORY
CASINGS)
CONTINOUS AIR
BARRIER AT EXTERIOR
SIDE OF SHEATHING,
PEEL AND STICK TAPED
AT EDGES AND SEAMS.
NEW INSULATED STUD
WALL.
EXTERIOR STUCCO
LINE OF INTERIOR
STUCCO
BASEMENT DOOR TO BI-PARTING
ARCHED CASEMENT WINDOW
EXTERIOR STUCCO
LINE OF INTERIOR
STUCCO
13. CAULK JOINT
10. SHIM SPACE
NEW INTERIOR
WOOD TRIM
9. NEW ARCHED FRENCH
BI-PARTING WINDOW
8. PEEL & STICK
5 1/2"NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
PAINTED
COMPOSITE OR
RUBBER CASINGS -
CURVED ABOVE
3 5/8" +/-
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
LINE OF INTERIOR
STUCCO
3 5/8" +/-5 1/2"
4. SASH STOP
& NEW TRIM
10. SHIM SPACE
8. PEEL
& STICK
INSTALL NEW BACKER
ROD AND CAULK JOINT,
MAINTAIN A MIN OF 1/4"
CAULK JOINT, 1/2"
PREFERRED.
9. NEW WINDOW
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
VARIESPAINTED
COMPOSITE OR
RUBBER CASINGS -
CURVED ABOVE
NEW PAINTED WOOD
INTERIOR SILL
9. NEW FRENCH BI-PARTING,
ARCHED WINDOW
12. FRAME EXPANDER
10. SHIM SPACE
6. FOAM CAVITIES
NEW INTERIOR
WOOD
PANELING,
MATCH
PROPORTIONS
TO PANELS IN
ADJACENT
ROOM, PAINT.
NEW
INSULATED
STUD WALL.
EXISTING SLOPED
CONCRETE DOOR
THRESHOLD
NEW SILL, COMPOSITE
MATERIAL, PAINTED
2'-0"CONTINOUS AIR BARRIER
AT EXTERIOR SIDE OF
SHEATHING, PEEL AND
STICK TAPED AT BOTTOM
EDGE AND CORNERS.
SEE PHOTOS PROVIDED BY ADD2-14 FOR INTENT
OF WOOD PANEL MATCH
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BASEMENT
SLIDING WDW.
A-3.10 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
BASEMENT
SLIDING WDW.
A-3.10 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
NEW PAINTED WOOD
INTERIOR SILL
9. NEW WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
EXISTING SLOPED
CONCRETE
WINDOW SILL
NEW P.T. BUCKS WITH
TWO BEADS OF
SEALANT
STONE WINDOW WELL,
VARIES IN HEIGH TAND
LOCATION
BASEMENT WINDOW SILL
Scale: 3" = 1'-0"
2
A-3.10
LINE OF INTERIOR
STUCCO
10. SHIM SPACE
8. PEEL &
STICK
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
13. CAULK JOINT
11. EXTERIOR
EXTENSION JAMBS,
3 SIDES
9. NEW FIBERGLASS
GLIDING WINDOW BASEMENT WINDOW HEAD
Scale: 3" = 1'-0"
3
A-3.10
EXTERIOR BRICK
LINE OF INTERIOR STUCCO,
REPAIR AS NEEDED
13. CAULK JOINT
10. SHIM SPACE
NEW INTERIOR EXTENSION
JAMB AND FACE TRIM
9. NEW FIBERGLASS
GLIDING WINDOW
11. EXTERIOR EXTENSION
JAMBS, 3 SIDES
8. PEEL & STICK
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
BASEMENT WINDOW JAMB
Scale: 3" = 1'-0"
1
A-3.10
STUCCO ON CONCRETE
EXTERIOR
CASING
STEEL SASH
CONCRETE, STEPS IN
OPENING NOT
KNOWN,
DETERMINE IN
FIELD
EXISTING GARAGE JAMB
Scale: 3" = 1'-0"
EX-2
A-3.11 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
GARAGE
WINDOWS
A-3.11 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
GARAGE
WINDOWS
A-3.11 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
EXTERIOR STUCCO
13. CAULK JOINT
10. SHIM SPACE
NEW INTERIOR
WOOD TRIM
9. NEW CASEMENT
WINDOW
8. PEEL & STICK
11. FIELD-APPLIED
EXTENSION JAMB
AND CASING, 3
SIDES
CONCRETE
WALL
CONDITIONS OF
CONCRETE OPENING
NOT KNOWN,
DETERMINE IN FIELD IF
STANDARD CASINGS
FIT AS SHOWN,2 3/4" +/-SK-2
PROPOSED GARAGE JAMB
Scale: 3" = 1'-0"
2
A-3.11
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
NEW PAINTED WOOD
INTERIOR SILL AND
ARPON
9. NEW CASEMENT
WINDOW
12. FRAME
EXPANDER
10. SHIM SPACE
NEW SILL, MATCH
PROFILE OF
EXISTING WITH
COMPOSITE
MATERIAL,
PAINTED
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
6. FOAM CAVITIES
CUT CONCRETE
AS NEEDED TO
PLACE NEW BUCK
IN PROPER
RELATIONSHIP TO
REPLACED
WINDOW SILL.
PROPOSED GARAGE WINDOW SILL
Scale: 3" = 1'-0"
1
A-3.11
CONCRETE, STEPS IN
OPENING NOT
KNOWN,
DETERMINE IN
FIELD
WOOD SILL
EXISTING GARAGE WINDOW SILL
Scale: 3" = 1'-0"
EX-1
A-3.11
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
GARDENER'S
WINDOWS
A-3.12 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
GARDENER'S
WINDOWS
A-3.12 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
GENERAL NOTES FOR WINDOW REPLACEMENT
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
REMOVE EXISTING STORM WINDOWS AND EXTERIOR SHUTTERS IN
LOCATIONS WHERE THEY OCCUR.
1A. REMOVE ALL SASHES. MODIFY THE REMAINING FRAMES (BY
CUTTING THE EXTERIOR STOP, REMOVING PARTING BEAD, ETC.) AS
NEEDED TO INSTALL NEW FRAME.
REMOVE WEIGHTS AND DRILL INTO WEIGHT POCKETS, OR REMOVE
FRAME AND WEIGHT POCKETS IN LOCATIONS AS NOTED.
DETERMINE IN FIELD IF THERE ARE "PORTS" FOR REMOVING THE
WEIGHTS. IF NOT, CUT FRAME AS NEEDED.
INTERIOR WOOD TRIMS TO REMAIN IN PLACE & UNDAMAGED
REMOVE EXISTING SASH STOP TO ACCESS ADDITIONAL CAVITIES.
REPLACE OR SUPPLEMENT AS NEEDED TO FIT NEW FRAME WITH
SUFFICIENT CAULK JOINT AT M.O. INSTALL NEW WINDOW FROM
EXTERIOR.
IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE TREATED
BLOCKING (SUBSILL, HEAD, AND JAMB) SECURED TO MASONRY
OPENING (APOXY ANCHORS)
FOAM ALL CAVITIES; WEIGHT POCKET, BEHIND TRIM, UNDER SILL.
EXAMINE THE CAVITIES IN THE MOCK-UP WINDOW
INSTALLATION TO DETERMINE LOCATIONS AND BEST METHODS
FOR ACHIEVING THE INTENT. FOR BIDDING PURPOSES, ASSUME
CAVITIES APPROXIMATELY AS SHOWN WITH ACCESS BY DRILLING
THROUGH JAMBS AND APRONS, REPAIRING AND PAINTING UPON
COMPLETION.
EXAMINE EXISTING WOODEN SUBSILLS. SCRAPE AND
REPAINT SOUND SILLS. REPLACE ROTTEN SILL AS
NEEDED WITH COMPOSITE MATERIAL (SEE UNIT
PRICES).
APPLY PEEL AND STICK MEMBRANE FROM EXISTING FRAME (OR
NEW BLOCKING AND SUBSILL) TO M.O. AFTER FOAMING ALL
CAVITIES.
INSTALL NEW WINDOW FROM EXTERIOR, ANCHOR TO EXISTING
FRAMES (SCREWING THRU PREDRILLED JAMBS) OR TO NEW BUCKS
WITH ANCHORS.
INSULATE SHIM SPACE
EXTERIOR CASING (FIELD OR FACTORY APPLIED) TO BE PROVIDED
BY WINDOW MANUFACTURER. INSTALL OVER PANNING AS
NEEDED TO EXTEND TO AND COVER LINE OF PREVIOUS CAULKING
JOINT.
SILL FRAME EXPANDER PROVIDED BY WINDOW MANUFACTURER,
FIELD APPLIED UNDER SILL. LEAVE OPEN 1/8 " AT SILL FOR
DRAINAGE; DO NOT CAULK.
INSTALL NEW BACKER ROD AND CAULK JOINT AT PERIMETER OF
CASINGS (3-SIDES), MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT ON
EXISTING INTERIOR AND EXTERIOR CASINGS AS NEEDED. REPAIR
ANY DINGS OR MARS (CAUSED BY WINDOW INSTALLATION) ON
EXISTING SILLS, RADIATOR COVERS, ADJACENT BOOKSHELVES,
PANELS, ETC.
INSTALL NEW EXTERIOR SHUTTER PINS SECURELY (WITH EPOXY)
INTO MASONRY WALL ACCORDING TO MANUFACTURER'S
INSTRUCTIONS. INSTALL SHUTTERS AND HOLDBACKS.
EXISTING INTERIOR SHUTTERS TO REMAIN IN PLACE, OR BE
REMOVED AND REINSTALLED AS NEEDED. MAGNETIC LATCHES TO
BE REMOVED FROM EXISTING WINDOWS FOR REINSTALLATION OR
REPLACED.
EXISTING BLINDS TO BE REMOVED AND REINSTALLED UNDER
SEPARATE CONTRACT.
ADD1-3, ADD2-12 and ADD3-10
NEW PAINTED WOOD
INTERIOR SILL AND
ARPON
9. NEW CASEMENT
WINDOW
12. FRAME EXPANDER
10. SHIM SPACE
EXISTING STONE SILL
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
CUT CONCRETE AS
NEEDED TO PLACE
NEW BUCK IN
PROPER
RELATIONSHIP TO
REPLACED
WINDOW SILL.
4 1/4" +/-
PROPOSED SILL
Scale: 3" = 1'-0"
2
A-3.12
STEPS IN MASONRY
OPENING NOT
KNOWN,
DETERMINE IN
FIELD.
WOOD SILL
CONCRETE SUBSILL
4" +/-
EXISTING SILL
Scale: 3" = 1'-0"
EX-2
A-3.12
9. NEW CASEMENT
WINDOW
SK-3A
PROPOSED HEAD
Scale: 3" = 1'-0"
3
A-3.12
11. FIELD-APPLIED
EXTENSION JAMB
AND CASING, 3
SIDES
SK-3
13. CAULK JOINT
10. SHIM SPACE
NEW INTERIOR
WOOD TRIM
9. NEW CASEMENT
WINDOW
8. PEEL & STICK
CONCRETE WALL
CONDITIONS OF
MASONRY OPENING
NOT KNOWN,
DETERMINE IN FIELD IF
STANDARD CASINGS
FIT AS SHOWN,
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT4 1/4" +/-PROPOSED JAMB
Scale: 3" = 1'-0"
1
A-3.12
STEEL LINTEL
STONE
EXISTING HEAD
Scale: 3" = 1'-0"
EX-3
A-3.12
EXTERIOR
CASING
STEEL SASH
STONE
EXISTING JAMB
Scale: 3" = 1'-0"
EX-1
A-3.12
NEW NARROW
STYLE
ALUMINUM
CLAD DOOR AND
FRAME
EXISTING WOOD
FLOORING, RAPAIR
AND TOUCH UP AS
NEEDED AT
FORMER SILL
REMOVAL.
SET SILL IN
SEALANT
EXISTING STONE
SILL
PAN FLASHING
NEW SCREEN DOOR BY DOOR
MANUFACTURER
SILL
Scale: 3" = 1'-0"
2
A-4.0 SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DOORS
LOGGIA
AND STAIR
A-4.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DOORS
LOGGIA
AND STAIR
A-4.0 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
STUCCO ON BRICK
DETERMINE IN FIELD IF
FACTORY-INSTALLED CASING
CAN BE PROVIDED AT THIS
OPENING. COMPOSITE
EXTERIOR CASING OTHERWISE
ACCEPTABLE.
INTERIOR WOOD
TRIM, PAINTED
LINE OF PLASTER
4 1/2" +/-
3/16"NEW SCREEN DOORS BY DOOR
MANUFACTURER
NEW NARROW STYLE
ALUMINUM CLAD DOOR
AND FRAME
PEEL AND STICK
WRAPPED TO
M.O.
EXISTING
BLOCKING OR
NEW AS NEEDED
INSULATED SHIM SPACE
DOOR JAMB - LOGGIA
Scale: 3" = 1'-0"
1
A-4.0
EXISTING STUCCO ON BRICK
REPLACE COPPER ROOF
FLASHING AS NEEDED
EXISTING EXTERIOR CASING
AND PANEL, PAINTED
INTERIOR WOOD
TRIM, PAINTED
LINE OF PLASTER
3/16"
PEEL AND STICK
CAULKING
SHIM SPACE
DOUBLE DOOR JAMB AND MULLION
Scale: 3" = 1'-0"
5
A-4.0
STUCCO ON BRICK
CLAD OR COMPOSITE
CASING
EXISITNG
INTERIOR WOOD
TRIM, PAINTED
10 1/2" +/- TRANSOM3/16"NEW INTERIOR
WOOD TRIM,
PAINTED
REMOVE
EXISTING FRAME
ENTIRELY
NEW TRANSOM
UNIT
PEEL AND STICK
TRANSOM HEAD
Scale: 3" = 1'-0"
4
A-4.0
BRICK OR STUCCO
ON BRICK
EXISTING
INTERIOR WOOD
TRIM, PAINTED4 1/2" +/-3/16"RETAIN CURVED EXTERIOR
CASING AS POSSIBLE BY
INSTALLING UNIT FROM INSIDE,
OR CAREFULLY REMOVING AND
REINSTALLING TRIM.
NEW CURVED,
INTERIOR WOOD
TRIM, PAINTED
PEEL AND STICK
SHIM SPACE
PAINTED INTERIOR MULL
BY WINDOW
MANUFACTURER
NEW CURVED,
TRANSOM UNIT
ARCHED TRANSOM VARIESTRANSOM HEAD
Scale: 3" = 1'-0"
8
A-4.0
OUTSWING
DOOR AT STAIR
INSWING DOOR
AT LOGGIA
GENERAL NOTES FOR DOOR REPLACEMENT
1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST)
FOR REPAIR AND REINSTALLATION.
2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR,
SILL AND DOOR FRAME
3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE &
UNDAMAGED
4.FOAM ALL CAVITIES
5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE
TREATED BLOCKING / BUCKS
6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY
LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE
DRAINAGE AWAY FROM WALL AND DOOR SILL.
7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O.
AT CORNERS.
8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR
EXISTING WOOD BUCKS, TURNING ONTO MASONRY
AND LAPPING PAN FLASHING.
9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING
OR NEW BUCKS.
10.INSULATE SHIM SPACE
11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR
CASING, PAINTED
12.INSTALL NEW BACKER ROD AND CAULK JOINT,
MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT
ON EXISTING INTERIOR AND EXTERIOR CASINGS AS
NEEDED.
14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED
UNDER SEPARATE CONTRACT
15.REINSTALL REPAIRED SCREEN DOORS, REPLACING
CLOSERS / HOLD OPENS.
CLAD OR COMPOSITE
CASING
10 1/2" +/- TRANSOMREMOVE
EXISTING FRAME
ENTIRELY
NEW TRANSOM
UNIT
NEW NARROW
STYLE
ALUMINUM
CLAD DOOR AND
FRAME3"SET SILL IN
SEALANT
NEW SCREEN DOOR BY DOOR
MANUFACTURER
MULLION
Scale: 3" = 1'-0"
3
A-4.0
BRICK OR STUCCO
ON BRICK
NEW COPPER PAN FLASHING
FULL WIDTH OF DOOR AND
CORNERS, EXTENDING MIN.
OF 4" OVER EXISTING
ROOFING.
RETAIN CURVED EXTERIOR
CASING AS POSSIBLE BY
INSTALLING UNIT FROM INSIDE,
OR CAREFULLY REMOVING AND
REINSTALLING TRIM.
NEW CURVED,
INTERIOR WOOD
TRIM, PAINTED
REMOVE EXISTING FRAME
ENTIRELY
NEW NARROW STYLE
ALUMINUM CLAD DOOR
AND FRAME3"CAULKING
PAINTED INTERIOR MULL
BY WINDOW
MANUFACTURER
NEW CURVED,
TRANSOM UNIT
ARCHED TRANSOM VARIESMULLION
Scale: 3" = 1'-0"
7
A-4.0
NEW SILL EXTENDS OVER
TRIM AND STEP BELOW
REMOVE EXISTING SILL
AND REPLACE WITH
NEW 2x P.T. BLOCKING
NEW COPPER PAN FLASHING
FULL WIDTH OF DOOR AND
CORNERS, EXTENDING MIN.
OF 4" OVER EXISTING
ROOFING.
NEW TRIM
REPLACE COPPER
ROOFING AS
NEEDED
SET DOOR SILL ON
SEALANT
2 1/8" +/-
RETAIN CURVED EXTERIOR
CASING AS POSSIBLE BY
INSTALLING UNIT FROM INSIDE,
OR CAREFULLY REMOVING AND
REINSTALLING TRIM.
REMOVE EXISTING FRAME
ENTIRELY
NEW NARROW STYLE
ALUMINUM CLAD DOOR
AND FRAME3"CAULKING
PAINTED INTERIOR MULL
BY WINDOW
MANUFACTURER
SILL
Scale: 3" = 1'-0"
6
A-4.0
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DECK DOOR
SECOND FLOOR
A-4.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
DECK DOOR
SECOND FLOOR
A-4.1 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
GENERAL NOTES FOR DOOR REPLACEMENT
1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST)
FOR REPAIR AND REINSTALLATION.
2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR,
SILL AND DOOR FRAME
3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE &
UNDAMAGED
4.FOAM ALL CAVITIES
5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE
TREATED BLOCKING / BUCKS
6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY
LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE
DRAINAGE AWAY FROM WALL AND DOOR SILL.
7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O.
AT CORNERS.
8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR
EXISTING WOOD BUCKS, TURNING ONTO MASONRY
AND LAPPING PAN FLASHING.
9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING
OR NEW BUCKS.
10.INSULATE SHIM SPACE
11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR
CASING, PAINTED
12.INSTALL NEW BACKER ROD AND CAULK JOINT,
MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT
ON EXISTING INTERIOR AND EXTERIOR CASINGS AS
NEEDED.
14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED
UNDER SEPARATE CONTRACT
15.REINSTALL REPAIRED SCREEN DOORS, REPLACING
CLOSERS / HOLD OPENS.
SECOND FLOOR
DOORS TO DECK
WITH WINDOWS
TO EITHER SIDE
STUCCO ON BRICK
INTERIOR WOOD
TRIM, PAINTED
REMOVE EXISTING SILL AND
REPLACE WITH NEW P.T.
BLOCKING, RAISING NEW SILL
APPROXIMATELY 1". COORDINATE
WITH MANUFACTURER'S DOOR
HEIGHT.
3 LAYERS OF NEW FLASHING: REMOVE
SUFFIENT DECKING AND SLEEPERS TO
ACCESS ROOF FLASHINGS. REMOVE AND
INSTALL FIRST LAYER OF NEW
MEMBRANE FLASHING FROM BELOW
NEW SUBSILL EXTENDING 12" OVER
ROOF. SECOND LAYER OF MEMBRANE
FLASHING TO COVER NEW SUBSILL AND
EXTEND 12" OVER LOWER FLASHING.
THIRD LAYER TO BE CONTINUOUS
COPPER DOOR PLAN FLASHING ACTING
AS COUNTER FLASHING AT SILL AND
FOLDING UP SIDES OF R.O.
FIELD-APPLY NEW
DECORATIVE CASINGS
(PAINTED, COMPOSITE
MATERIAL) INSTALLED ON
TOP OF
MANUFACTURER-PROVIDE
D EXTENSION JAMBS /
MULLS.
INTERIOR WOOD
TRIM, PAINTED
REMOVE
EXISTING FRAME
HEAD
CONDITIONS
UNKNOWN.
DETERMINE IN
FIELD.
DOOR HEAD
Scale: 3" = 1'-0"
3
A-4.1
3/16"REMOVE EXISTING CASINGS TO INSTALL
DOOR AND WINDOW. FIELD-APPLY NEW
DECORATIVE CASINGS (PAINTED,
COMPOSITE MATERIAL) INSTALLED ON
TOP OF MANUFACTURER-PROVIDED
EXTENSION JAMBS / MULLS.
ADD BLOCKING AS NEEDED
AND INSULATE ANY CAVITIES
NEW TRIM
PEEL AND STICK
SHIM SPACE
3/16"SCREEN DOOR BY
DOOR MANUFACTURER
EXISTING INTERIOR
WOOD TRIM, PAINTED
DOOR JAMB (AT WINDOW MULLION)
Scale: 3" = 1'-0"
1
A-4.1
PHOTO OF EXISTING DOOR SILL AT DECK
Scale: Actual Size
1
A-4.1
REMOVE EXISTING SILL AND
REPLACE WITH NEW P.T.
BLOCKING, RAISING NEW SILL
APPROXIMATELY 1". COORDINATE
WITH MANUFACTURER'S DOOR
HEIGHT.
3 LAYERS OF NEW FLASHING: REMOVE
SUFFIENT DECKING AND SLEEPERS TO
ACCESS ROOF FLASHINGS. REMOVE AND
INSTALL FIRST LAYER OF NEW
MEMBRANE FLASHING FROM BELOW
NEW SUBSILL EXTENDING 12" OVER
ROOF. SECOND LAYER OF MEMBRANE
FLASHING TO COVER NEW SUBSILL AND
EXTEND 12" OVER LOWER FLASHING.
THIRD LAYER TO BE CONTINUOUS
COPPER DOOR PLAN FLASHING ACTING
AS COUNTER FLASHING AT SILL AND
FOLDING UP SIDES OF R.O.
SET DOOR SILL ON
SEALANT
FIELD-APPLY NEW
DECORATIVE CASINGS
(PAINTED, COMPOSITE
MATERIAL) INSTALLED ON
TOP OF
MANUFACTURER-PROVIDE
D EXTENSION JAMBS /
MULLS.
INTERIOR WOOD
TRIM, PAINTED
REMOVE
EXISTING FRAME
EXTERIOR
DECKING
APPROXIMATE
LINE OF ROOF
BELOW
NEW INTERIOR TRIM,
NATURAL FINISH.
DOOR SILL AT DECK
Scale: 3" = 1'-0"
2
A-4.1
SMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
ARCHED DOORS
BASEMENT
A-4.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETSMITH COLLEGE PRESIDENT'S HOUSEWINDOW & DOORREPLACEMENTREVISIONS:
DATENUMBER
JAN. 19, 2016
ARCHED DOORS
BASEMENT
A-4.2 KRAUS-FITCHARCHITECTS, INC.110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETPERMIT
AND
CONSTRUCTION
SET
ADD-1 JAN. 22, 2016
ADD-2 FEB. 9, 2016
ADD-3 FEB. 17, 2016
EXISTING SLOPED
CONCRETE DOOR
THRESHOLD
NEW SILL SET IN
SEALANT
DOOR SILL
Scale: 3" = 1'-0"
2
A-4.2
BASEMENT
ARCHED DOORS
WITH SIDELITES
LINE OF INTERIOR
STUCCO
2 3/4" +/-
INSTALL NEW BACKER
ROD AND CAULK JOINT,
MAINTAIN A MIN OF 1/4"
CAULK JOINT, 1/2"
PREFERRED.
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
VARIES5 1/2"
PAINTED
COMPOSITE OR
RUBBER CASINGS -
CURVED ABOVE
CURVED FRAME
AND DOOR HEAD
REPAIR AND
RE-INSTALL
EXISTING ARCHED
SCREEN DOOR
COMPLETELY
REMOVE EXISTING
DOOR FRAME
DOOR HEAD
Scale: 3" = 1'-0"
3
A-4.2
5 1/2"LINE OF INTERIOR
STUCCO
CAULK JOINT
NEW INTERIOR
WOOD TRIM 2 3/4" +/-3/16"
NEW P.T. BUCKS
WITH TWO BEADS
OF SEALANT
DOOR FRAME,
FACTORY MULLED
SIDELIGHT SASH COMPLETELY
REMOVE EXISTING
DOOR FRAME
REPAIR AND RE-INSTALL
EXISTING ARCHED
SCREEN DOOR
PEEL AND STICK AND
INSULATED SHIM
SPACE
DETERMINE IN FIELD IF
FACTORY-INSTALLED CURVED
CASING CAN BE PROVIDED AT
THIS OPENING. COMPOSITE
EXTERIOR CASING OTHERWISE
ACCEPTABLE.
DOOR JAMB
Scale: 3" = 1'-0"
1
A-4.2
GENERAL NOTES FOR DOOR REPLACEMENT
1.REMOVE EXISTING SCREEN DOORS (WHERE THEY EXIST)
FOR REPAIR AND REINSTALLATION.
2.REMOVE EXTERIOR TRIM (EXCEPT AS NOTED), DOOR,
SILL AND DOOR FRAME
3.INTERIOR WOOD TRIMS TO REMAIN IN PLACE &
UNDAMAGED
4.FOAM ALL CAVITIES
5.IN LOCATIONS AS NEEDED, INSTALL NEW PRESSURE
TREATED BLOCKING / BUCKS
6.REMOVE AND REPLACE FLASHING IN DECK / BALCONY
LOCATIONS, REPLACE WITH COPPER. CREATE POSITIVE
DRAINAGE AWAY FROM WALL AND DOOR SILL.
7.INSTALL COPPER PAN FLASHING, EXTENDING UP R.O.
AT CORNERS.
8.APPLY PEEL AND STICK MEMBRANE OVER NEW OR
EXISTING WOOD BUCKS, TURNING ONTO MASONRY
AND LAPPING PAN FLASHING.
9.INSTALL NEW DOOR FRAMES ANCHORED TO EXISTING
OR NEW BUCKS.
10.INSULATE SHIM SPACE
11.APPLY FACTORY-SUPPLIED OR COMPOSITE EXTERIOR
CASING, PAINTED
12.INSTALL NEW BACKER ROD AND CAULK JOINT,
MAINTAIN A MIN OF 1/4" CAULK JOINT, 1/2"
PREFERRED.
13.PAINT NEW INTERIOR TRIM PIECES. TOUCH UP PAINT
ON EXISTING INTERIOR AND EXTERIOR CASINGS AS
NEEDED.
14.EXISTING BLINDS TO BE REMOVED AND REINSTALLED
UNDER SEPARATE CONTRACT
15.REINSTALL REPAIRED SCREEN DOORS, REPLACING
CLOSERS / HOLD OPENS.
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
WINDOW
SCHEDULE
A-5.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
WINDOW
SCHEDULE
A-5.0110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSED
Sash Operation - Muntin PatternGlazingVerify
Opening -
Masonry
Approx.
(stop to stop)
Approx. Interior Opening
Color
Material and
Exterior Finish:
Finish
Material and
Frame:
Interior
Finish
Material and
Interior Sash:
Finish
Material and
Interior Trim:
Treatment
Existing Window
Shutters
Exterior
Existing
Shutters
Interior
Existing
Comments
0 01-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 02-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 03-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 04-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 05-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 06-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 07-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 08-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 09-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 10-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 11-Z Room
Gardener's
DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR
0 12-Q Room
Gardener's
CASEMENT
FRENCH METAL
BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False
0 13-X Room
Laundry
DOOR W/ PANEL BELOW
BI-PARTING CASEMENT
8 PANES EACH CLEAR/INSUL PEAK
5'-6"x 6'-10" AT
TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR
0 14-V Room
Laundry
DOOR W/ PANEL BELOW
BI-PARTING CASEMENT
8 PANES EACH CLEAR/INSUL PEAK
5'-0" x 6'-7" AT
TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR
1 01-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False
1 02-R Guest INSWING
FRENCH CASEMENT,
DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED
1 03-R Guest INSWING
FRENCH CASEMENT,
DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False
1 05-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 06-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 07-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 08-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False
1 09-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False
1 10-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 11-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 12-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 13-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False
1 14-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZED
EXISTING WINDOW IS AN INSERT REPLACEMENT,
1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False
1 16-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False
1 17-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 18-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 19-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 20-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill
1 21-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head
1 22-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 23-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False
1 24-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
1 26-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 27-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 28-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
2 01 -S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 02 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 03 -C Guest 206 INSWING
FRENCH CASEMENT
PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 04 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 05 -D Guest 206 OUTSWING
FRENCH CASEMENT
DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 06 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 07 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 08 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 09 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 10 -D Master Bdrm OUTSWING
FRENCH CASEMENT
DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 11 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 12 -C Master Bdrm OUTSWING
FRENCH CASEMENT
PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 13 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 14 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE
2 15 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False
2 16 -H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 17 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 18 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 19 -H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL
2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO
2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO
2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False
2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 30-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
2 31-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True
3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 08 SIM
-F
Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False
ADD 1-8
ADD 1-8
WINDOW TREATMENT KEY:
V= VALENCE
PS=PULL SHADE
D=DRAPES
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
WINDOW
SCHEDULE &
ELEVATIONS
A-5.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
WINDOW
SCHEDULE &
ELEVATIONS
A-5.1110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSED
Sash Operation - Muntin PatternGlazingVerify
Opening -
Masonry
Approx.
(stop to stop)
Approx. Interior Opening
Color
Material and
Exterior Finish:
Finish
Material and
Frame:
Interior
Finish
Material and
Interior Sash:
Finish
Material and
Interior Trim:
Treatment
Existing Window
Shutters
Exterior
Existing
Shutters
Interior
Existing
Comments
0 01-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 02-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 03-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 04-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 05-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 06-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 07-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 08-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 09-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 10-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False
0 11-Z Room
Gardener's
DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR
0 12-Q Room
Gardener's
CASEMENT
FRENCH METAL
BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False
0 13-X Room
Laundry
DOOR W/ PANEL BELOW
BI-PARTING CASEMENT
8 PANES EACH CLEAR/INSUL PEAK
5'-6"x 6'-10" AT
TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR
0 14-V Room
Laundry
DOOR W/ PANEL BELOW
BI-PARTING CASEMENT
8 PANES EACH CLEAR/INSUL PEAK
5'-0" x 6'-7" AT
TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR
1 01-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False
1 02-R Guest INSWING
FRENCH CASEMENT,
DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED
1 03-R Guest INSWING
FRENCH CASEMENT,
DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False
1 05-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 06-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 07-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False
1 08-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False
1 09-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False
1 10-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 11-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 12-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat
1 13-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False
1 14-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZED
EXISTING WINDOW IS AN INSERT REPLACEMENT,
1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False
1 16-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False
1 17-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 18-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 19-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
1 20-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill
1 21-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head
1 22-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 23-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False
1 24-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
1 26-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 27-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
1 28-P Garage CASEMENT
FRENCH METAL
SINGLE CASEMENT PARTING STRIP
OF SIMULATED
8 LITES EACH SIDE
CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False
2 01 -S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 02 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 03 -C Guest 206 INSWING
FRENCH CASEMENT
PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 04 -B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 05 -D Guest 206 OUTSWING
FRENCH CASEMENT
DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False
2 06 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 07 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 08 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 09 -A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True
2 10 -D Master Bdrm OUTSWING
FRENCH CASEMENT
DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 11 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 12 -C Master Bdrm OUTSWING
FRENCH CASEMENT
PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 13 -B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False
2 14 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE
2 15 -H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False
2 16 -H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 17 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 18 -H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 19 -H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL
2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO
2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO
2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False
2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 30-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
2 31-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True
3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 08 SIM
-F
Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False
Window Schedule BuildingShape / TypeLocationFrame TypeExisting Sash Operation PROPOSEDSash Operation - Muntin PatternGlazingVerifyOpening - Masonry Approx. (stop to stop)Approx. Interior Opening ColorMaterial and Exterior Finish: FinishMaterial and Frame: Interior FinishMaterial and Interior Sash: FinishMaterial and Interior Trim: TreatmentExisting Window ShuttersExterior Existing ShuttersInterior Existing Comments001-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False002-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False003-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False004-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False005-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False006-L Basement INSWING AWG SLIDER N/A TRANS 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False007-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False008-Y Basement INSWING AWG MAPES PANEL N/A N/A 42 X 20.5 39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False009-L Basement INSWING AWG SLIDER N/A TRANS 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False010-Y Basement INSWING AWG MAPES PANEL N/A N/A 41" X 19"39" X 16" SASH FG, WHITE FG, WHITE FG, WHITE FG, WHITE NONE False False011-Z RoomGardener's DOOR FIXED W/ PANEL BELOW 9 PANES CLEAR/INSUL Wx H 36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR012-Q RoomGardener's CASEMENTFRENCH METAL BI-PARTING CASEMENT 6 PANES EACH CLEAR/INSUL 41" X 44.5"36" X 37"ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE False False013-X RoomLaundry DOOR W/ PANEL BELOWBI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK5'-6"x 6'-10" AT TBD ALUM., WHITE FG, WHITE FG, WHITE WD., WHITE NONE True False PANEL BELOW BY SITE CONTRACTOR014-V RoomLaundry DOOR W/ PANEL BELOWBI-PARTING CASEMENT 8 PANES EACH CLEAR/INSUL PEAK5'-0" x 6'-7" AT TBD ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False PANEL BELOW BY SITE CONTRACTOR101-G Guest DH 6/6 CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False102-R Guest INSWINGFRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING HARDWARE IS DAMAGED103-R Guest INSWINGFRENCH CASEMENT, DH 4 PER SASH CLEAR/INSUL 42"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False105-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False106-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False107-M Dining FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D False False108-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False109-J Reception DH 6/6 CLEAR/INSUL 42.5" x 86"33"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE False False110-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat111-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat112-M Living FRENCH CASEMENT 2 fixed panels 8 each CLEAR/INSUL N/A 45 1/2" X 78"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V False False Window seat113-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D False False114-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False DOUBLE GLAZEDEXISTING WINDOW IS AN INSERT REPLACEMENT, 1 15-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False116-K Living DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D True False117-K Lav DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True118-K Office DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True119-K 104 DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True120-K Butlers DH 6/6 CLEAR/INSUL 45"x86"36"x80"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Wood and SS backsplash extends 9" above sill121-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False Corian backsplash 9" above sill, valence in front of head122-G Kitchen DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False123-G Wash Room DH 6/6 CLEAR/INSUL 42.5"x65.5"33"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False False124-T Bath 111 DH 4/4 CLEAR/INSUL 32" x 65.5"23"x60"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True126-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False127-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False128-P Garage CASEMENTFRENCH METAL SINGLE CASEMENT PARTING STRIPOF SIMULATED 8 LITES EACH SIDE CLEAR/INSUL 36.5" x 51" INTER. MO ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True False201-S Guest 206 DH 4/4 CLEAR/INSUL 36.5" x 70"23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False202-B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False203-C Guest 206 INSWINGFRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False204-B Guest 206 DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False205-D Guest 206 OUTSWINGFRENCH CASEMENT DH 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, D, PS False False206-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True207-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True208-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True209-A Private Study DH 6/6 CLEAR/INSUL 33" X 57"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE False True210-D Master Bdrm OUTSWINGFRENCH CASEMENT DOUBLE HUNG 6/6 CLEAR/INSUL 35" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False211-B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False212-C Master Bdrm OUTSWINGFRENCH CASEMENT PICTURE 16 PANES (4x4)CLEAR/INSUL 50" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False213-B Master Bdrm DH COMBO 4/4 CLEAR/INSUL 23" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS False False214-H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False INTEGRAL BOOKCASE215-H Master Bdrm DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE D, AUTO BLINDS True False216-H Master Bath DH 6/6 CLEAR/INSUL 45"x86"33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True217-H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True218-H Master Bath DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True219-H Bath 204 DH 6/6 CLEAR/INSUL 33" X 64"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 20 -H Guest 214 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 21 -H Bath 213 DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True
2 22 -H Kit/Laundry DH 6/6 CLEAR/INSUL ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE PS True False BACKSPLASH: 6" ABOVE SILL
2 23 -E Bath 211 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE NONE True True EXISTING STORM / SCREEN COMBO
2 24 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 25 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS True False EXISTING STORM / SCREEN COMBO
2 26 -E Guest 209 DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False EXISTING STORM / SCREEN COMBO
2 27 -E Library DH 6/6 CLEAR/INSUL 42.5" x 62.5"33" X 56"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, AUTO SHADE False False
2 28-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 29-W Library DOOR DH WITH PANEL BELOW 6/6 LOWER SASH
TEMPERED
CLEAR/INSUL,
39" x 91.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False PANEL BELOW BY SITE CONTRACTOR
2 30-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
2 31-N STUDY DH 6/6 TEMPERED
CLEAR/INSUL
ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE V, PS False False TO DOORS (WITHIN 24")
SAFETY GLAZING (IBC 2009) FOR WINDOWS ADJACENT
3 01 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 02 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 03 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 04 -F Attic 303 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 05 -F Attic Bath DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE N/A False True
3 06 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 07 -F Attic 302 DH 6/6 CLEAR/INSUL 30" x 51"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE ROLL BLIND False False
3 08 SIM
-F
Attic 305 DH 6/6 CLEAR/INSUL 27"x43.5"ALUM., WHITE WD., WHITE WD., WHITE WD., WHITE MINI BLIND False False
ALL WINDOW ELEVATIONS SCALE: 1/4"=1'-0"
SIMBADCBA
FRENCH CASEMENT
CHANGED TO DH
(2 TOTAL)
COMBINATION WINDOW WITH CENTRAL FRENCH CASEMENT CHANGED
TO COMBINATION WINDOW WITH CENTRAL FIXED PICTURE WINDOW(2 TOTAL)
(2 TOTAL)
DOUBLE DH
2ND FLOOR,
LOGGIA
SECOND FLOOR, SOUTHSECOND FLOOR,
PRIVATE STUDY
GEF
H
(4 TOTAL)(7 TOTAL)
(+1 SIMILAR)
(5 TOTAL)
(9 TOTAL, 4 W/
SPLAYED
INTERIOR WALL)
SECOND FLOOR,
MASTER SUITE
KITCHEN/BUTLERS ATTIC 2ND FLOOR, NE
(NEW)
1
3.3
3
3.3
2
3.3
2
3.3
1
3.3
2
3.0
1
3.0 1
3.0
(EXISTING)(PROPOSED)
2
3.4
1
3.4
3
3.4
1
3.6
2
3.6
(EXISTING)(PROPOSED)
3
3.1P
2
3.1P
2
3.0
FIELD APPLIED CASINGS, INSTALL
OVER ALUMINUM EXTENSION
JAMBS
1
3.7
2
3.7
F
Q
L
K
P
J
RGARDENER'S
RM EAST
(1 TOTAL)
BI-PARTING
CASEMENTRECEPTION
(2 TOTAL)
FIRST FLOOR NE
(8 TOTAL, 4 WITH
SPLAYED INTERIOR
WALL)
BASEMENT
(7 TOTAL TO BE REPLACED
WITH SLIDING UNIT)
BAY WINDOW BEDROOM 206
(1 TOTAL)
GUEST 110
(2 TOTAL, FRENCH CASEMENT
TO BE REPLACED BY DH)
M
GARAGE
(3 TOTAL) SINGLE
CASEMENT WITH
SIMULATED
CENTER PARTING
STRIP
1
3.1P
1
3.0P
2
3.0P
2
3.1P
4
3.2P
3
3.1P
1
3.5
2
3.5
(EXISTING)(PROPOSED)
3
3.2P
N N204-H
2
3.11
2
3.4
3
3.4
2
4.1
TEMPERED GLASS
ADJACENT TO DOORS (>24")
2
3.10
1
3.10
3
3.10
2
3.121
3.11
3
3.12
1
3.12
1
3.2P
(12 TOTAL,
SASHES ONLY,
2 EACH PER
PREVIOUS
OPENING)2
3.2P
ADD 1-9
(2 TOTAL) EXISTING LIBRARY DOORS
TO BE TURNED INTO DH WINDOW
TYPE "W" WITH PANEL AND
TEMPERED LOWER SASH
5'-6"
V(1 TOTAL)X W
(1 TOTAL) EXISTING GARDENER'S RM
DOOR TO BE REPLACED BY FIXED
WINDOW OVER WOOD PANEL
(2 TOTAL) LIBRARY, TO BE
REPLACED BY WINDOWS1'-0"(2 TOTAL) EXISTING LAUNDRY ROOM DOORS TO
BE TURNED INTO WINDOWS: 013-X & 014-V
(PROPOSED)
(PROPOSED)(PROPOSED)
(EXISTING)(PROPOSED)6'-7" +/- MO6'-10" +/- MO5'-0"(EXISTING)
YBASEMENT
(3 TOTAL WINDOWS TO
BE REPLACED WITH
MAPES PANELS)
GARDENER'S
RM NORTH
Z
3
3.8
2
3.8
1
3.8
4
3.8
3
3.9
2
3.9
4
3.9
1
3.9
3
3.9
2
3.9
4
3.9
1
3.92'-0"2'-0"3.0P
2
3.10
(SIMILAR)
1
3.10
3
3.10
1
3.8
3
3.12
1
3.12
(SIMILAR)
(SIMILAR)
(SIMILAR)
38.5"73.5" +/- MOADD 1-9
2'-0"ADD 1-9
TEMP
S T
BEDROOM 206
(1 TOTAL)
BATH 111
(1 TOTAL)
2
3.5
1
3.0P
2
3.0P
M=MARVIN OPTION
K=KOLBE OPTION
1
3.0P
2
3.0P
WINDOW TREATMENT KEY:
V= VALENCE
PS=PULL SHADE
D=DRAPES
KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
DOOR SCHEDULE
& ELEVATIONS
A-5.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANET KRAUS FITCHARCHITECTS, INC.SMITH COLLEGE PRESIDENT'S HOUSEWINDOW AND DOOR REPLACEMENTREVISIONS:
DATENUMBER
JAN 19, 2016
DOOR SCHEDULE
& ELEVATIONS
A-5.2110 Pulpit Hill RoadAmherst, Ma 01002 413-549-5799Fax: 413-549-7918www.krausfitch.comHOME COMMUNITY PLANETADD-1 JAN 22, 2016
ADD-2 FEB. 9, 2016
ADD-2 FEB. 17, 2016
PERMIT
AND
CONSTRUCTION
SET
Door Schedule - ALTERNATE NO 2
Nominal Size Openings Door Data
Mark Location Approx. WidthApprox. HeightDoor Operation HW SetApprox. RO WidthApprox. RO HeightExisting Window Treatment Comments
0 01-A GARDENER'S ROOM 3'0"6'8"Swing Simple 1 38.5"VARIES - PEAK AT 73.5"NONE
0 02-B FROM MECH. COURT 3'0"6'8"Swing Simple 1 67"VARIES - PEAK AT 82.5"NONE BELOW
SCREEN DOOR; SEE NOTE 1,
UTILIZE THE EXISTING
0 03-X LAUNDRY 3'0"6'8"Swing Simple 1 VARIES - PEAK AT 78"SEE NOTE 1, BELOW
1 05-D DINING TO LOGGIA 3'0"7'3"Swing Simple 2 39"89"FIXED LACE CURTAIN SEE NOTE 2, BELOW
1 06-E RECEPTION TO LOGGIA 4'0"7'4"Swing Bi-part 3 51"86"VALANCE AND DRAPES SEE NOTE 2, BELOW
1 07-D LIVING TO LOGGIA 3'0"7'3"Swing Simple 2 39.5"90"FIXED LACE CURTAIN SEE NOTE 2, BELOW
2 01-F STAIR TO FRONT BALCONY 4'0"8'0"Swing Bi-part 3 52"ARCHED TRANSOM
VARIES TO TOP OF
SHEER CURTAIN
2 04-H STUDY TO ROOF DECK 4'0"7'4"Swing Bi-part 3 WINDOWS
INCLUDES
DETERMINE IN FIELD VALANCE AND PULL SHADES NEW SILL 1".
HEIGHT OF DOOR TO RAISE
FLASHINGS AT SILL. ADJUST
SCREEN DOORS. REPAIR
(IN-SWING) AND ADD SLIDING
REVERSE SWING OF DOORS
2 05-I PRIVATE STUDY TO BALCONY 4'0"7'3"Swing Bi-part 3 51"DETERMINE IN FIELD NONE AS NEEDED.
REPAIR FLASHINGS AT SILL
SWINGING SCREEN DOOR.
SEE NOTE 2, BELOW FOR
ADD 1-10
ADD 2-16
ADD 2-16
107-D 201-F
LOGGIA, LR STAIR LANDING 8'-0"46"
105-D
106-E
KITCHEN LOGGIA, DR
LOGGIA, RECEPTION88" DOOR 4'-0"
DOOR
51" MO +/- MO
SIMILAR
SIMILAR
1
4.0
1
4.0
4
4.0
2
4.0
SIMILAR
1
4.0
4
4.0
2
4.0
SIMILAR
1
4.0
3
4.0
2
4.0
4
4.0
5
4.0
7
4.0
6
4.0
8
4.0
NEW DOUBLE DOORS
AND TRANSOM,
NEW PAIR OF SWINGING
SCREEN DOORS BY DOOR
MANUFACTURER.ADD2-16
205-I
STUDY 207
PRIVATE STUDY 205
REPLACE EXISTING DOOR,
N N204-H
2
3.4
3
3.4
1
4.1
3
4.1
2
4.1
1
4.0
4
4.0
2
4.1
SIMILAR
SIMILAR
SIMILAR
NEW PAIR OF SWINGING
SCREEN DOORS BY DOOR
MANUFACTURER.ADD2-16
1. EXISTING ARCHED SCREEN DOORS:
A. REMOVE FOR REPAIR
B. CUT SIDE AND BOTTOM STYLES AS NEED TO FIT INTO NEW DOOR FRAMES.
C. PAINT
D. REINSTALL WITH NEW CLOSER / HOLD OPEN
2. NEW RECTANGULAR SCREEN DOORS, SEE DRAWINGS FOR OPERATION (SWINGING OR
SLIDING). SCREEN DOOR PANEL AND HARDWARE BY DOOR MANUFACTURER.
002-B
WEST SOUTH-FACING
LAUNDRY ROOM DOOR (2
TOTAL, TO BE TURNED INTO
WINDOW, SEE WINDOW
SCHEDULE)70.5" +/- MO82.5" +/- MO66" MO +/- MO
79" MO36"22"+/-79" MO70.5" +/- MO60" +/- MO
3'-0"
003-X
EAST-FACING LAUNDRY
ROOM DOOR (2 TOTAL, TO
BE TURNED INTO WINDOW,
SEE WINDOW SCHEDULE)
1
4.2
3
4.2
2
4.2
TEMPERED GLASS AT
SIDELIGHTS ADJACENT
TO DOORS (>24")
THIS IS THE WINDOW
ELEVEVATION
3
4.2
1
4.2
2
4.2
SIM
SIM
70.5" +/- MO73.5" +/- MO38.5" MO
GARDENER'S RM (1 TOTAL):
WITH BIGGER LITE. OTHER
DOOR TO BE TURNED TO
WINDOW.
001-A
THIS IS THE WINDOW
ELEVEVATION
3
4.2
1
4.2
2
4.2
SIM
ADD1-10