DrwgsJORDAN HOUSE EMERSON HOUSE SCALE DATE DRAWN BY CHECKED BYISSUED FOR PERMIT & BIDDINGSMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSA APRIL 18, 2014 JJR KJC COVER SCJG2513 JORDAN HOUSE SMITH COLLEGE KOSHER KITCHEN NORTHAMPTON, MASSACHUSETTS LOCATION MAP BERKSHIRE DESIGN GROUP 4 ALLEN PLACE NORTHAMPTON, MA 01060 RICK KLEIN (413) 582-7000 rick@berkshiredesign.com CIVIL ENGINEER KOHLER & LEWIS 27 MECHANIC STREET KEENE, NH 03431 ADAM KOHLER DAN LEWIS ROY SWAIN (603) 352-4841 adam@kohlerandlewis.com dan@kohlerandlewis.com roy@kohlerandlewis.com MECHANICAL ENGINEER SMITH COLLEGE FACILITIES MANAGEMENT 126 WEST STREET NORTHAMPTON, MASSACHUSETTS 01063 DIANA RANDALL (413) 585-2364 drandall@smith.edu OWNER BLACK RIVER DESIGN, ARCHITECTS 73 MAIN STREET MONTPELIER, VT 05602 JOHN HEMMELGARN KATE COFFEY (802) 223-2044 johnh@blackriverdesign.com katec@blackriverdesign.com ARCHITECT SHEPERD ENGINEERING, INC JOHN SHEPERD 1308 GRAFTON STREET WORCESTER, MA 01604 (508) 757-7793 jsheperd@shepherdengineeringinc.com ELECTRICAL ENGINEER DRAWING INDEX A COVER L1.1 SITE PLAN & SITE DETAILS L2.1 SIGNAGE DETAILS A0.1 GENERAL NOTES & DEMOLITION PLAN AND NOTES A1.1 FLOOR PLANS, RC PLANS, AND ENLARGED PLAN A5.1 INTERIOR ELEVATIONS AND DETAILS A8.1 DOOR AND FINISH SCHEDULES M1.1 KITCHEN PLUMBING PLAN M1.2 KITCHEN HEATING AND VENTILATION PLANS M1.3 MECHANICAL DETAILS & LEGEND E1 FLOOR PLANS - LIGHTING & POWER PHILIP R SHERMAN, P.E. PHIL SHERMAN 444 WILMOT CENTER ROAD ELKINS, NH 03233 (603) 526-6190 psherman@prsherman.com CODE SPECIALIST PROJECT LOCATION KEY PLAN REVISIONS UP DN DN UP PANTRY KITCHEN STORAGE DEMOLITION EXISTING RADIATOR DEMOLITION EXHAUST HOOD AND ASSOCIATED DUCTWORK DEMOLISH EXHAUST HOOD EXISTING BULKHEAD TO REMAIN EXISTING COLUMN TO REMAIN REMOVE STAIR, RAILS AND TRIM REMOVE SOFFIT ABOVE REMOVE BUILT-INS REMOVE ASSEMBLY IN FRONT OF LOWER SASH OF WINDOW REMOVE WINDOW AND WALLS TO ACCOMODATE NEW DOR AND TRANSOM COORD. WITH WALK WIDTH60"DEMOLISH A PORTION OF BRICK WALL AND CAP. BRICK TO REMAIN BELOW DECKING THE OWNER IS RESPONSIBLE FOR ALL ASBESTOS ABATEMENT WHICH IS BELIEVED TO BE COMPLETE. IF ADDITIONAL ASBESTOS IS UNCOVERED DURING CONSTRUCTION THE CONTRACTOR IS TO NOTIFY THE OWNER IMMEDIATELY SO THE ASBESTOS CAN BE ABATED. CONTRACTOR TO COORDINATE AREAS OF ABATEMENT WITH OWNER'S ABATEMENT CONTRACTOR. THE PLANS ON THIS SHEET ARE INTENDED TO ASSIST THE CONTRACTOR IN LOCATING MAJOR AREAS OF DEMOLITION AND TO GET AN OVERALL VIEW OF THE FLOOR PLANS. THEY ARE NOT INTENDED TO BE A COMPLETE LIST OF ALL DEMOLITION REQUIRED TO BE DONE BY THE CONTRACTOR FOR THIS PROJECT. ASBESTOS ABATEMENT DO NOT INTERUPT POWER, WATER, TELEPHONE OR SEPTIC WITHOUT PRIOR APPROVAL FROM THE OWNER. SHORE AND BRACE ALL AREAS AS REQUIRED TO INSURE STRUCTURAL INTEGRITY BEFORE PROCEEDING WITH DEMOLITION WORK. SEE DIVISION 1 SPECIFICATIONS FOR ADDITIONAL INFORMATION ON SCOPE OF WORK, CUTTING AND PATCHING, DEMOLITION AND HAZARDOUS MATERIAL PRESENCE AND REMOVAL. CONTRACTOR RESPONSIBLE FOR PATCHING DISTURBED AREAS CREATED FROM REMOVAL OF EXISTING CONSTRUCTION. REMOVE ALL MECHANICAL AND ELECTRICAL ITEMS NOT REQUIRED FOR USE IN NEW SYSTEM. DO NOT REMOVE SUCH ITEMS UNTIL THEY ARE NO LONGER REQUIRED FOR USE IN OCCUPIED AREAS. REMOVE EXISTING FLOOR FINISHES TO SUBFLOOR WHERE NEW FLOOR FINISHES ARE INDICATED. IN ADDITION ANY QUARRY TILE LOCATED ON THE WALLS TO BE DEMOLISHED. TRENCH EXISITNG SLABS AS REQUIRED FOR NEW CONSTRUCTION, SEE MECHANICAL AND ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR LOCATIONS OF NEW CONTRUCTION THAT MAY REQUIRE THIS TRENCHING. OWNER SHALL HAVE THE RIGHT TO ANY SALVAGE MATERIAL. CONTRACTOR SHALL VERIFY WHAT MATERIALS THE OWNER WISHES TO RETAIN PRIOR TO DEMOLITION. REFER TO SPECIFICATION FOR SALVAGE RIGHTS OF OWNER. VERIFY ITEMS TO BE REUSED WITH THE OWNER. PROTECT THOSE ITEMS TO BE REUSED FROM DAMAGE UNTIL TIME AT WHICH THEY ARE TO BE REUSED. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS. BEFORE START OF WORK, FIELD VERIFY EXISTING HEIGHTS. CONTACT ARCHITECT IF DIMENSIONS, RELATIONSHIPS, OR ELEVATIONS ARE DIFFERENT THAN INDICATED. ALL PLAN ANGLES ARE 90° OR 45° UNLESS OTHERWISE INDICATED. MISC CARPENTRY PROVIDE BLOCKING AT ALL WALL MOUNTED ACCESSORIES, INCLUDING BUT NOT LIMITED TO: SHELVING TOILET ACCESSORIES, WALL STOPS CABINETRY ARCHITECTURAL WOODWORK FIRE EXTINGUISHERS CABINETRY PRE-MANUFACTURED CASEWORK: SEE CASEWORK ELEVATIONS FOR CONFIGURATION. PROVIDE DUPONT CORIAN, PRICE GROUP B, SOLID SURFACE COUNTERTOPS WITH INTEGRAL 4" BACKSPLASH. INSULATION PROVIDE INSULATION IN EXTERIOR INFILL AT DEMOLISHED HOOD DUCTING AS REQUIRED TO MATCH EXISTING WALL CONDITION TO REMAIN. SEALANT PROVIDE SEALANT AT ALL JOINTS, TRANSITIONS, CORNERS, AND CHANGES IN MATERIALS AND AS REQUIRED TO COMPLETE AN INSTALLATION. WINDOW/DOORS DOOR TAG - SEE DOOR SCHEDULE WINDOW TAG - SEE WINDOW SCHEDULE EXISTING WINDOWS - NO WORK, EXCEPT PAINTING WT - WINDOW TO RECEIVE LEVELOR VISIONS FAUX WOOD 2" CORDED SLATTED BLINDS IN CREAM 12067102, OR OWNER APPROVED COLOR IN 2" CLASSIC VALUE SERIES XX FIRE EXTINGUISHERS WALL HUNG FIRE EXTINGUISHER VERIFY LOCATIONS AND MOUNTING HEIGHTS WITH OWNER AND CODE OFFICIAL BEFORE INSTALLATION STRUCTURAL ALL COLUMNS MAY NOT BE INDICATED ON ARCHITECTURAL FLOOR PLANS. PLUMBING SEE ENLARGED PLANS FOR SCOPE OF TOILET AND BATH ACCESSORIES FINISHES ROOMS THAT ARE NOT LABELED WITH A ROOM NAME AND NUMBER ARE TO RECEIVE SIMILAR FINISHES AS ADJOINING ROOM. FE TOILET & BATH ACCESSORIES SEE ENLARGED BATHROOM PLANS AND SPECIFICATIONS FOR SCOPE OF ACCESSORIES MECHANICAL CUH =CABINET UNIT HEATER - SEE MECHANICAL FIRESTOPPING - ROOMS SHALL BE CONSTRUCTED WITH ENCLOSURE TO PROVIDE FIRE RESISTANT RATING INDICATED. PROVIDE THROUGH PENETRATION FIRE STOP SYSTEM AND FIRE RESISTIVE JOINT SEALANT SYSTEMS AS REQUIRED TO ENSURE RATING. EX WT FOLLOWING THE ROOM NAME INDICATES THE ENITRE ROOM IS TO BE PROTECTED BY AN AUTOMATIC SPRINKLER SYSTEM. SP SCALE DATE DRAWN BY CHECKED BYISSUED FOR PERMIT & BIDDING 1/4" = 1'-0"SMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSA0.1 APRIL 18, 2014 JJR KJC GENERAL NOTES & DEMOLITION PLAN AND NOTES SCJG2513 SCALE: 1/4" = 1'-0"1 LEVEL ONE DEMOLITION PLAN DEMOLITION NOTES REVISIONS GENERAL NOTES UP DN DN R. F. DW UP 14'-0"A5.12 1 LIVING/DINING 101 SP STORAGE 102 SP HC TOILET 103 SP KITCHEN 105 SP CASE OUT EXISTING COLUMN TO REMAIN SPRINKLER PIPE TO REMAIN PROVIDE NEW UPPER SASH TO MATCH SIZE AND CONFIGURATION OF EXISTING WINDOWS TO REMAIN VIF9 1/2"VIF 7" VIF 3'-6 13/16" LOCATE WALL TO ALLOW GYP. BD. TO CONCEAL EXISTING SPRINKLER PIPE INFILL AT REMOVED EXHAUST HOOD TO MATCH EXISTING CASED OPENING WITH PAINTED 1x5 WOOD TRIM EX EX 30 WT 30 WT A1.1 4 A5.1 4 A5.1 7 A5.1 5 JAN. 104 SP 102A 103A 101A 104A A5.1 FE 3/4" MTL. FURRING WITH (1) LAYER OF 5/8" TYPE "X" GWB, TYPICAL AT ALL INTERIOR WALLS UNLESS OTHERWISE NOTED PAVED GRADE RAMP WITH RETAINING WALL ON BUILDING SIDE ONLY, SEE CIVIL DRAWINGS TOOTH IN SALVAGED BRICK AT ENDS OF BRICK WALLS NOW OPEN AS REQUIRED +- 19'-0" O.D. OF FRAMING+- 13'-8 5/8" V.I.F.TREX ENHANCE 1" SQUARE EDGE BOARD DECKING (NO JOINTS) WITH TREX HIDEAWAY HIDDEN FASTENERS. COLOR TO BE SELECTED FROM MANUFACTURER'S STANDARD COLORS GE CAFE SERIES 30" ELECTRIC RANGE CS980STSS FRAME AND DECK A REMOVABLE SECTION OF DECK TO CREATE ACCESS FOR EXISTING CATCH BASIN PTD PVC WAINSCOTTING FROM TOP OF COVE BASE TO 48" UP, ACROSS ENTIRE LENGTH OF WALL 3 PROVIDE SNOW GUARDS AT ROOF ABOVE DOOR, SEE ALLOWANCE DECK TO FRAME CLEAR OF EXISTING WALL SPIGOT TO REMAIN 3/4" METAL FURRING WITH (2) LAYERS OF 5/8" TYPE "X" GWB. THIS WALL FROM EXTERIOR WALL TO EXISTING CORNERKITCHEN 105 SP LIVING/DINING 101 SP HC TOILET 103 SP STORAGE 102 SP L2L2 F1 L2L2 L2 L2L2 L2 L2L2 L2 EFL1 UC1 UC1 UC1UC1 UC1 UC1 UC1 UC1 LOWER GYP. BD. SOFFIT 8'-0" AFF CASE AROUND EXISTING COLUMN RANGE EXHAUST HOOD PRELIMINARY LIGHTING LAYOUT. FINAL LOCATIONS TO BE DETERMINED ON SITE BASED ON EXISTING JOIST LOCATIONS EXT1 GYP. BD. 8'-0"AFF GYP. BD. 8'-0"AFF GYP. BD. 8'-0"AFF GYP. BD. 9'-0"AFF GYP. BD. 9'-0"AFF L2 EQ.6'-0"EQ.L2 L2 L2 L2L2L2 PR-1 LINE OF INFILLED STAIR OPENING ABOVE LOWER GYP. BD. SOFFIT 8'-0" AFF EQ. 6'-0" 6'-0" EQ. ADVANCE TABCO SC-38 STAINLESS STEEL CEILING-MOUNTED POT RACK, SECURE TO CEILING CUH MECHANICAL EQUIPMENT, CENTER ON DOOR OPENING BELOW AND INSTALL AS CLOSE TO WALL AS ALLOWABLE APPROXIMATE LOCATION OF EXISTING EXPOSED SPRINKLER PIPING. PAINT ALL EXPOSED SPRINKLER PIPING (1) LAYER OF 5/8" TYPE "X" GWB OVER 1x FURRING AT EXISTING CEILING TYPICAL NOTE: MODIFY EXISTING SPRINKLER SYSTEM AS REQUIRED TO ACCOMODATE NEW LAYOUT. SUBMIT LAYOUT FOR REVIEW. UPSZIE LINES AND PROVIDE ADDITIONAL HEADS AS NECESSARY. JORDAN HOUSE EMERSON HOUSE INFILL EXISTING STAIR OPENING DEMOLISH EXISTING HAND AND GUARD RAILSCORRIDOR 201 A5.1 8 NEW STUD WALLS AROUND EXISTING STAIR OPENING HC TOILET 103 JAN. 104 3 1/2"6'-2"3 1/2" VERIFY WITH EXISTING CHASE +- 8'-5 5/16"3 1/2"3" 3/4"1'-6"1'-6"42"GB 36"GB ALIGN WITH EXISTING WALLA5.1 6 PAINTED 3/4" PLYWOOD SHELF WITH 3/4"x3/4" SOFT WOOD NOSING. SHELF AT 6'-8" A.F.F. 5 PAINTED 3/4" PLYWOOD SHELVES WITH 3/4"x3/4" SOFTWOOD NOSINGS ON HEAVY DUTY STANDARDS HOLD EDGE OF NOSING BACK 1" FOR FROM EDGE OF WALL PTD SD TPD SCALE DATE DRAWN BY CHECKED BYISSUED FOR PERMIT & BIDDINGSMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSA1.1 APRIL 18, 2014 JJR KJC FLOOR PLANS, RC PLANS, AND ENLARGED PLAN SCJG2513 SCALE: 1/4" = 1'-0"1 LEVEL ONE PLAN SCALE: 1/4" = 1'-0"2 LEVEL ONE REFLECTED CEILING PLAN KEY PLAN SCALE: 1/4" = 1'-0"3 PARTIAL SECOND FLOOR PLAN SCALE: 1/2" = 1'-0"4 ENLARGED HC TOILET ROOM PLAN REVISIONS BUILDING-MOUNTED SIGN DW BY OWNER 34" MAX.CABINETS, TYPICAL EACH CABINET TO RECEIVE 2 ADJUSTABLE SHELVES SHELVES, BY OWNER SOLID SURFACE COUTERTOP WITH INTEGRAL BACKSPLASH INTEGRAL VINYL COVE BASE, TYPICAL UC1 UC1 UC1 UC1 UC1 30"15" ADA SINK BASE 48"24" KITCHEN 10510"MECHANICAL EQUIPMENT, CENTER ON DOOR OPENING BELOW AND INSTALL AS CLOSE TO WALL AS ALLOWABLE CUH ALTERNATE: TILE ABOVE BACKSPLASH TO BOTTOM OF CABINET ABOVE AND CONTINUE BEHIND REMOVABLE SLOPED WOOD CLOSURE PANEL COUNTER TO OVERHANG END BY 1" MODIFY END PANEL OF SINK BASE TO ACCOMODATE TUBING FOR DETERGENT BOTTLES PTD A5.1 9 KITCHEN 105 EACH CABINET TO RECEIVE 2 ADJUSTABLE SHELVES REFRIGERATOR AND FREEZER BY OWNER 34" MAX.12" 36" 18" UC1UC1UC1UC1UC1 ALTERNATE: TILE ABOVE BACKSPLASH TO BOTTOM OF CABINET ABOVE AND CONTINUE BEHIND LEVEL 1 PLAN 100'-0"36"1"5"1"24"1"4"2" PT 2x12 JOISTS AT 16" O.C. TREX ENHANCE DECKING OR APPROVED EQUAL EXISTING GRADE, VARIES PT LEDGER BEYOND PAINTED STEEL RAIL ASSEMBLY 1" 3/4" THRU CARRIAGE BOLT, PAINTED TO MATCH RAIL ASSEMBLY LEVEL 1 PLAN 100'-0" 12" O.C. 12" O.C. ANCHOR DETAIL AT EXISTING BRICK WALL NOTIFY ARCHITECT IF WALL IS NOT SOLID MASONRY LINE OF LEDGER TO BE FASTENED AFTER SEALANT OVER ANCHOR HOLES CONTINUOUS BEAD OF SEALANT ABOVE ANCHOR HOLES TO DIVERT WATER ADHESIVE ANCHOR HOLES FOR FASTENING LEDGER 6" SIMPSON LUS212 HANGER OR EQUAL PT. DOUBLE 2x12 LEDGER, TYP. 3/4" HILTI HIT HY 150 ADHESIVE ANCHOR @ 12" O.C. STAGGER VERTICALLY PT 2x12's SPACED 16" O.C. TREX DECKING TO BE SELECTED BY OWNER EXISTING MASONRY WALL NOTIFY ARCHITECT IF WALL IS NOT SOLID MASONRY. ANCHORING DETAIL TO BE REVISED EXISTING GRADE, VARIES PAINTED BLACK METAL ANGLE, THRU BOLTED , AS REQUIRED FOR SECURING RAILING ASSEMBLY LEVEL 1 PLAN 100'-0" ASPHALT WALK, SEE CIVIL DRAWINGS PT BLOCKING AND SHIMS AS REQUIRED TO ALIGN ROTATED DECKING WITH DECK PT 2x12 JOISTS AT 16" O.C. TREX ENHANCE DECKING OR APPROVED EQUAL TOOTHED IN BRICK ON THIS FACE, SALVAGED FROM DEMOLISHED PORTION OF WALL EXISTING GRADE, VARIES PT LEDGER BEYOND HC TOILET 103 36"GB 42"GB BASE SEE SCHEDULE HEIGHT AND LENGTH OF GRAB BARS TO MEET LOCAL CODE REQUIREMENTS ALTERNATE-TILE AT ALL TOILET WALLS TO 5'-0" A.F.F. MIRROR TO BE BOBRICK CHANNEL FRAME MIRROR 18"Wx30"H - B-165 1830 SD PTD TOILET PAPER DISPENSER, TO BE BOBRICK MODEL B2740 NOTE: SOAP DISPENSER (SD) AND PAPER TOWEL DISPENSER (PTD) TO BE PROVIDED BY OWNER FOR CONTRACTOR INSTALLATION PROVIDE SANI CANS-TOUGH GUY SANITARY NAPKIN RECEPTACLE IN WHITE. MODEL #2NX101 Level 2 111'-4"VIF EXACT AREA OF INFILL TO BE V.I.F. 29"EXISTING WALL 3/4" PLYWOOD SUBFLOOR TO ALIGN WITH EXISTING 2x JOISTS @ 16" O.C., MAXIMIZE DEPTH UP TO 2x12, COORDINATE WITH EXISTING FLOOR ASSEMBLY THICKNESS TO ALIGN WITH FLOOR AND CEILING 1X3 WOOD FURRING AS REQUIRED 5/8" TYPE "X" GWB, PAINT LINE OF EXISTING WALL OR FLOOR NEW WALL AROUND EXISTING VERTICAL STAIR OPENING MIN. 11"MIN.9"MIN.27"MIN. 8" ADA CLEARANCE SHALL BE 30" WIDE MIN. COORDINATE REMOVABLE CLOSURE PANEL WITH ADA CLEARANCES AND SINK DRAIN REQUIREMENTS SHELF FOR DETERGENT BOTTLES LIVING/DINING 101 NEW PAINTED GYPSUM WALL BOARD CEILING PAINTED WOOD TRIM, MATCH SIZE FROM EXISTING WINDOWS NEW 3'-0"x6'-8" DOOR AND TRANSOM IN EXISTING WINDOW OPENING PAINT EXISTING WINDOW TO REMAIN (WINDOW TREATMENT NOT SHOWN) 1x6 PAINTED WOOD BASEBOARD SCALE DATE DRAWN BY CHECKED BYISSUED FOR PERMIT & BIDDINGSMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSA5.1 APRIL 18, 2014 JJR KJC INTERIOR ELEVATIONS AND DETAILS SCJG2513 SCALE: 1/2" = 1'-0"1 KITCHEN ELEVATION B SCALE: 1/2" = 1'-0"2 KITCHEN ELEVATION A SCALE: 1 1/2" = 1'-0"4 SECTION THRU DECK AND METAL RAIL SCALE: 1 1/2" = 1'-0"7 FRAMING DETAIL AT EXISTING PRIVACY WALL SCALE: 1 1/2" = 1'-0"5 SECTION THRU DECK AND GRADE RAMP SCALE: 1/2" = 1'-0"6 HC TOILET ROOM ELEVATION SCALE: 1 1/2" = 1'-0"8 INFILL DETAIL AT STAIR OPENING REVISIONS SCALE: 1" = 1'-0"9 SECTION THRU ADA SINK BASE SCALE: 1/2" = 1'-0"3 ENTRY DOOR ELEVATION ALUM - ALUMINUM BB - BALL BEARING BF - BARRIER FREE ELEV - ELEVATION EXIST - EXISTING EXT - EXTERIOR FLR - FLOOR FNCTN - FUNCTION FT - FEET HD - HEAVY DUTY HG - HALF GLASS HGHT - HEIGHT HNDL - HANDLE VERIFY SIZE AND FRAME REQUIRED FOR NEW DOORS IN EXISTING CONSTRUCTION PROVIDE SCHEDULED HARDWARE FOR BOTH LEAVES OF DOUBLE DOORS EXCEPT FLUSH BOLTS EXTERIOR THRESHOLDS TO EXTEND BEYOND EDGE OF FOUNDATION SECOND NUMBER IN FRAME ELEVATION COLUMN INDICATES FRAME HEAD DEPTH ALL GLAZING IN FIRE RATED DOORS TO BE WIRED GLASS ALL GLAZING IN EXTERIOR DOORS TO BE 1" INSULATING GLASS SIGNAGE SHALL CONSIST OF BOTH DIRECT APPLIED LETTERS AND ROOM SIGNS, VERIFY FINAL SIGNAGE LIST WITH ARCHITECT BEFORE ORDERING ALL PANIC HARDWARE TO BE KEYED COORDINATE DOOR PULL AND KEY CYLINDER LOCATIONS TO ALLOW FULL KEY ACCESS TO KEY CYLINDER PROVIDE KEY CONTROL SYSTEM NRP - NON REMOVABLE PIN SCTN - SECTION SCW - SOLID CORE WOOD SIM - SIMILAR STD - STANDARD STORERM - STOREROOM THK - THICKNESS UC - UNDERCUT HW - HARDWOOD IN - INCHES INT - INTERIOR MAT'L - MATERIAL MI - METAL INSULATED MIN - MINIMUM "XXX" IN SIGNAGE COLUMN REPRESENTS ROOM NUMBER. THREE (3) NUMBER CONTENT TO BE DETERMINED FLUSH EXT.DOOR HEIGHTDOORWIDTH 2 X DOOR WIDTH DOOR HEIGHT10 20 12 DOOR WIDTH DOOR HEIGHTWINDOW HEAD ROCOORDINATE WITH EXISTING1 2x4" WOOD STUDS GYP. BD. DOOR CASING PRE-HUNG WOOD DOOR JAMB 4 3/4"PVC - WALTON PLASTICS WALPLAX875 PVC WALL PANELS SUSP - SUSPENDED SHEET VINYL - FORBO ETERNAL CLASSIC COLLECTION WITH HEAT-WELDED SEAMS AND 4" INTEGRAL FLASH COVE BASE. COLOR TO BE SELECTED FROM FULL FANCE OF MANUFACTURERS STANDARD COLORS POLY - POLYURETHANE CLEARCOAT EXIST - EXISTING GYP, GYP BD OR GWB - GYPSUM WALL BOARD SEE REFLECTED CEILING PLAN(S) FOR LOCATION AND HEIGHT OF DROP GYP. BD. SOFFITS. SEE FLOOR PLAN(S) FOR LOCATION OF CHANGES IN FLOORING MATERIAL PROVIDE ACCESS PANELS IN CEILING CONSTRUCTION AS NECESSARY TO ACCESS MECHANICAL EQUIPMENT. SEE MECHANICAL DRAWINGS AND SPECIFICATIONS. PRIME AND SEAL KNOTS AT ALL NEW WOOD TRIM SCALE DATE DRAWN BY CHECKED BYISSUED FOR PERMIT & BIDDINGSMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSA8.1 APRIL 18, 2014 JJR KJC DOOR AND FINISH SCHEDULES SCJG2513 DOOR NOTES & ABBREVIATIONS DOOR TYPESDOOR FRAME ELEVATIONS NUMBER LOCATION FIRE RATINGDOOR 1" UNDERCUTFRAME HARDWARE SIGNAGE COMMENTS NUMBER FROM ROOM NUMBER FROM ROOM NAME TO ROOM NUMBER TO ROOM NAME TYPE MATERIAL FINISH SIZE ELEV FRAME SECTION FRAME MATERIAL FRAME FINISH LATCH SET WIDTH HEIGHT THICKNESS FUNCTION 101A 101 LIVING/DINING EXTERIOR EXT. 3'-0 1/16" 6'-8" 1 3/4" 12 "EXTERIOR" SEE SECTION 087100, DOOR HARDWARE SIMPSON 2130 WITH ULTRABLOCK TECHNOLOGY. PROVIDE TRANSOM WITH SDL'S. PROVIDE CARD KEY ACCESS PER COLLEGE STANDARDS WITH MANUAL OVERRIDE 101A 102A 102 STORAGE 101 LIVING/DINING FLUSH SCW PAINT 6'-0" 7'-0" 1 3/4" 20 1 WOOD PAINT "CLOSET" SEE SECTION 087100, DOOR HARDWARE 102A 103A 101 LIVING/DINING 103 HC TOILET FLUSH SCW PAINT 3'-0" 7'-0" 1 3/4" 10 1 WOOD PAINT "BATH" SEE SECTION 087100, DOOR HARDWARE 103A 104A 104 JAN. 101 LIVING/DINING FLUSH SCW PAINT 3'-0" 7'-0" 1 3/4" 10 1 WOOD PAINT "JANITOR" SEE SECTION 087100, DOOR HARDWARE 104A DOOR SCHEDULE DOOR FRAME SECTIONS FINISH NOTES & ABBREVIATIONS ROOM FLOOR WALL CEILING BASE BASE COMMENTS NUM.NUM. NAME MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH 101 LIVING/DINING SHEET VINYL GWB/EXISTING PAINT GWB PAINT 1x6 SOFTWOOD PAINT 101 102 STORAGE SHEET VINYL GWB PAINT GWB PAINT iNTEGRAL VINYL COVE 102 103 HC TOILET SHEET VINYL GWB EPOXY PAINT GWB EPOXY PAINT iNTEGRAL VINYL COVE PROVIDE ADD ALTERNATE FOR CERAMIC TILE WITH EPOXY GROUT ON WALLS TO 48" AFF 103 104 JAN. SHEET VINYL GWB/EXISTING/PVC EPOXY PAINT GWB EPOXY PAINT iNTEGRAL VINYL COVE PVC PANELS FLOOR TO CEILING THREE SIDES OF MOP SINK 104 105 KITCHEN SHEET VINYL GWB/EXISTING EPOXY PAINT GWB EPOXY PAINT iNTEGRAL VINYL COVE 105 201 CORRIDOR EXISTING GWB/EXISTING PAINT GWB PAINT EXISTING/MATCH EXISTING EXIST/MATCH EXIST. BASE FINISH OF NEW TO MATCH EXISTING.201 FINISH SCHEDULE REVISIONS R. F. DW K L OHLER & EWIS E N G I N E E R I N G Mechanical Engineering for the NortheastSMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTS73 MAIN STREET MONTPELIER, VERMONT 05602 ISSUED FOR PERMIT & BIDDING R.F.DW K L OHLER & EWIS E N G I N E E R I N G Mechanical Engineering for the Northeast 73 MAIN STREET MONTPELIER, VERMONT 05602SMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSISSUED FOR PERMIT & BIDDING K L OHLER & EWIS E N G I N E E R I N G Mechanical Engineering for the Northeast 73 MAIN STREET MONTPELIER, VERMONT 05602SMITH COLLEGE KOSHER KITCHENJORDAN HOUSESMITH COLLEGE - NORTHAMPTON, MASSACHUSETTSISSUED FOR PERMIT & BIDDING