170 Glendale_PELetter_2016-10-25Eng. Number OAA688687_C2_02
October 24 2016
Page 1 of 2
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com
Structural Evaluation
ATC Site Number & Name 15035, Northampton Landfill MA, MA
Carrier Site Number & Name 4SH0213C, SH213/ATC Northampton
Site Location Westhampton Road
Florence, MA 01062-9806, Hampshire County
42.29556944 N / -72.70784444 W
Tower Description 198.9 ft Monopole
Basic Wind Speed
Basic Wind Speed w/ Ice
Code
95 mph (3-Second Gust)
40 mph (3-Second Gust) w/ 1” ice
ANSI/TIA-222-G / 2009 IBC /Massachusetts State Building Code, 8th Edition
Existing and Reserved Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
197.0 197.0
3 Alcatel-Lucent ALU 800MHz External
Notch Filter
Low Profile Platform (4) 1 1/4" Hybriflex
(1) 0.24" Cat 5 Sprint Nextel
1 Alcatel-Lucent MPR e
3 Alcatel-Lucent 800MHz RRH
3 Alcatel-Lucent 1900MHz RRH
3 Alcatel-Lucent TD-RRH8x20-25 w/ Solar
Shield
1 RFS SB2-107AMPT
3 RFS APXVTM14-C-I20
3 RFS APXVSPP18-C-A20
187.0 187.0
3 Ericsson KRY 112 144/1
Low Profile Platform (12) 1 5/8" Coax
(1) 1 5/8" Hybriflex T-Mobile 3 Ericsson AIR 21, 1.3 M, B2A B4P
3 Ericsson AIR 21, 1.3M, B4A B2P
175.0 175.0
12 Kathrein 860 10025
Low Profile Platform
(12) 1 5/8" Coax
(2) 0.78" 8 AWG 6
(1) 0.39" Fiber Trunk
AT&T Mobility
3 Ericsson RRUS-11 800MHz
6 Powerwave TT19-08BP111-001
1 Raycap DC6-48-60-18-8F.
6 Kathrein 800 10122
1 Andrew SBNH-1D6565C
2 Powerwave P65-17-XLH-RR
144.0 144.0 1 Telewave ANT150F2 Side Arm (1) 7/8" Coax City Of Northampton
Police Dept
142.0 142.0
6 RFS FD9R6004/2C-3L
Low Profile Platform (12) 1 5/8" Coax Verizon
3 Antel BXA-171085-8BF-EDIN-X
2 Antel BXA-70063/4CF
6 Antel LPA-80063/4CF
1 Antel BXA-70063-6CF-EDIN-X
135.0 135.0 3 RFS APXV18-206517 Flush (6) 1 5/8" Coax Metro PCS
120.0 120.0 1 Radio/ODU Flush (1) 1/2" Coax
AT&T Mobility
1 4' HP Dish
116.0 116.0 1 Radio/ODU Flush (1) 3/8" Coax 1 2' HP Dish
114.0 114.0 1 Radio/ODU Flush (1) 3/8" Coax 1 2' HP Dish
73.0 73.0 1 PCTEL GPS-TMG-HR-26N Flush (1) 1/2" Coax Sprint Nextel
Eng. Number OAA688687_C2_02
October 24 2016
Page 2 of 2
ATC Tower Services, Inc. - 3500 Regency Parkway, Suite 100 - Cary, NC 27518 – 919-468-0112 Office - 919.466.5414 Fax - www.americantower.com
Equipment to be Removed
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
187.0 187.0 - - - (1) 1.28" Cable Bundle T-Mobile
Proposed Equipment
Elevation¹ (ft) Qty Antenna Mount Type Lines Carrier Mount RAD
187.0 187.0 3 Ericsson RRUS 11 B12 Low Profile Platform (6) 1 5/8" Coax T-Mobile 3 Andrew LNX-6515DS-A1M
1 Mount elevation is defined as height above bottom of steel structure to bottom of mount, RAD elevation is defined as center of antenna
above grade level (AGL).
Install proposed coax inside of the pole shaft.
The existing and proposed loads listed in the tables above are compared to the tower’s current design capacity
or previous structural analysis. The tower should be re-evaluated as future loads are added or if actual loads are
found different from those listed in the tables. The subject tower and foundation are adequate to support the
above stated loads in conformance with specified requirements.
JDB/AMS