Loading...
fp111/2":12 " 1/2": 1 2 " 1/2": 1 2 " 1/2":12 " 1/4":12" 1/4":12" 1/4":12" 1/4":12" 1/4 " : 1 2 " 1/4":1 2 " 1/4 " : 1 2 " 1/4":1 2 " 1/4":1 2 " 1/4 " : 1 2 " 1/4":1 2 " 1/4" : 1 2 " 1/4":1 2 " 1/4 " : 1 2 " 1/4 " : 1 2 " 1/4":1 2 " 1/4":12" 1/4":12" 1/4":12 " 1/4": 1 2 " SLOPED EXISTING ROOF STRUCTURE EXISTEXIST EXIST HPHPHPHPEJ-HPEJ-HPHP HPHPEJ-HPEJ-HPNOT IN CONTRACT NOT IN CONTRACT NOT IN CONTRACT COURTYARD COURTYARDCOURTYARDSLOPEDEXISTINGROOFSTRUCTURESLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE EJ-HP SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE EJ-HPSLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE SLOPED EXISTING ROOF STRUCTURE FLAT EXISTING ROOF STRUCTURE OVERFLOW SCUPPER P.2 P.2 P.2 P.2 P.4 P.1 P.1 P.1 P.1 P.1 P.1 P.1 R.D. R.D. R.D.R.D. R.D. R.D. R.D. R.D. R.D. R.D.R.D. R.D. R.D. R.D. P.1 P.1 P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.34"V. P.34"V. P.34"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P.3 4"V. P1.1 ROOF PLAN - PLUMBINGR RK Finn Ryan Road School498 Ryan RoadNorthampton, MA 01060Drawn By: Checked By: Approved By: Drawing Scale: Revisions: No.Date Description Date: AS NOTED APRIL 14, 2015 ROOF PLAN - PLUMBING SCALE: 1/16" = 1'-0"1 N ABBREV PLUMBING LEGEND SYMBOL DESCRIPTION GAS COCK VTR VENT THRU ROOF PIPE PLUMBING PIPING TYPICAL RD ROOF DRAIN P.1 KN PLUMBING KEY NOTE VTR RTU ROOF TOP UNITRTU PLUMBING KEY NOTES: REMOVE THE EXISTING ROOF DRAIN STRAINER, FLASHING COLLAR & BOLTS PER THE GENERAL CONTRACTORS PHASING PLAN SO THE ROOF IS WATERTIGHT AT THE COMPLETION OF WORK EACH DAY. THE EXISTING ROOF DRAIN BODY & PIPING SHALL REMAIN ACTIVE. ONCE THE NEW ROOF IS INSTALLED, INSTALL NEW ROOF DRAIN STRAINER, FLASHING COLLAR AND NEW BOLTS. HPG HPG HI PRESSURE GAS REMOVE AND DISPOSE OF EXISTING ROOF DRAIN & BODY. PROVIDE NEW DRAIN TYPE "A" AS SPECIFIED, MATCH EXISTING PIPE SIZE. P.2 P.1 1. 2. 3. 4. GENERAL NOTES: THE PLUMBING DRAWINGS ARE DIAGRAMMATIC AND ARE TO BE USED FOR THE PURPOSE OF ESTABLISHING GENERAL LOCATIONS OF PIPING RUNS, SIZES OF PIPING, AND QUANTITIES OF FIXTURES AND EQUIPMENT TO BE FURNISHED HEREIN. REFER TO ARCHITECTURAL DRAWINGS FOR DIMENSIONS FOR EXACT LOCATIONS OF ALL PLUMBING FIXTURES, AND EQUIPMENT, INCLUDING FLOOR DRAINS, AND MOUNTING HEIGHTS. IN THE EVENT OF CONFLICT OR IF DIMENSIONS ARE NOT SHOWN, OBTAIN FIELD DIRECTIVE FROM THE ARCHITECT AS TO THE LOCATIONS OF ALL VISIBLE EQUIPMENT. PAY PARTICULAR CARE TO COORDINATE WITH THE ARCHITECT'S FIELD REPRESENTATIVE ALL FLOOR DRAIN AND FLOOR CLEANOUT LOCATIONS. ALL PIPING SHOWN ON THIS PLAN SHALL BE RUN CONCEALED ABOVE SUSPENDED CEILINGS, IN CHASES, OR IN PARTITIONS UNLESS SPECIFICALLY NOTED OTHERWISE. EXISTING CONDITIONS INDICATING PIPING AND EQUIPMENT LOCATIONS ARE TAKEN FROM ENGINEERING FIELD NOTES AND DRAWINGS OF THE ORIGINAL BUILDING CONSTRUCTION ARE TO BE CONSIDERED APPROXIMATE ONLY. FIELD VERIFY POINTS OF CONNECTIONS OF NEW TO EXISTING BEFORE INSTALLING ANY PIPE OR EQUIPMENT. BRING ANY DISCREPANCY TO THE ATTENTION OF THE ARCHITECT. MAINTAIN PLUMBING SYSTEMS IN OTHER BUILDING AREAS AT ALL TIMES DURING THE CONSTRUCTION. REFER TO PHASING PLANS AND SPECIFICATIONS ON THE ARCHITECT'S DRAWINGS & SPECIFICATIONS. EXTEND 4" CAST IRON VENT TO MINIMUM 24" ABOVE PROPOSED ROOF ELEVATION.P.3 REMOVE AND DISPOSE OF EXISTING ROOF DRAIN & BODY. PROVIDE NEW DRAIN TYPE "B" AS SPECIFIED, MATCH EXISTING PIPE SIZE. P.4