69 Maple St approved 2017-07-28ARCHITECT: ROYS. BROWN ARCHITECTS 85 CHILSON ROAD WILBRAHAM, MAO I 095 PH 41 3.59G.23GO FAX 41 3.59G.23GO EMAIL rsba85@yahoo.com REPLACEMENT ROOFING FLORENCE FIRE STATION b9 MAPLE STREET FLORENCE, MA O I Ob2 . . . ... PROJECT LOCUS MAP SCALE l 11 = 801-011 SHEET INDEX: T. I TITLE SHEET A. I ROOF PLAN A.2 SARNAFIL ROOF DETAILS A.3 EPDM ROOF DETAILS CITY OF NORTHAMPTON 2 I O MAIN STREET NORTHAMPTON, MAO I OGO DAVIDJ. NARKEWICZ, MAYOR DAVID POMERANTZ, DIRECTOR OF CENTRAL SERVICES DUANE NICHOLS, FIRE CHIEF Reviewed, Approved 7/28/17Louis Hasbrouck SCOPE OF WORK: I. BASE BID, ON EXISTING LOW ROOF, REMOVE ALL EXISTING EPDM ROOFING MEMBRANE, REGLETS, INSULATION, CANT STRIPS, FLASHINGS AND METAL EDGE COPING. REMOVE BUILT-UP ROOF MEMBRANE, INSULATION, CANT STRIPS AND FLASHINGS DOWN TO EXISTING METAL DECK INCLUDING COUNTERFLASHINGS, VENTILATOR CURB FLASHINGS, AND PLUMBING VENT FLASHINGS. USE OF LEAF BLOWERS IS NOT ALLOWED, BROOM CLEAN ONLY. 2. ALTERNATE NO. I, ON EXISTING UPPER ROOF, REMOVE ALL EXISTING EPDM ROOFING MEMBRANE, REGLETS, INSULATION, CANT STRIPS, FLASHINGS AND METAL EDGE COPING. REMOVE BUILT-UP ROOF MEMBRANE, INSULATION AND FLASHINGS DOWN TO EXISTING CONCRETE DECK INCLUDING REGLETS, COUNTERFLASHINGS, SCUPPERS, DOWNSPOUTS, VENTILATOR CURB FLASHINGS, AND PLUMBING VENT FLASHINGS. USE OF LEAF BLOWERS IS NOT ALLOWED, BROOM CLEAN ONLY. 3. REPLACE ANY EXISTING WOOD NAILERS FOUND TO BE DETERIORATED BEFORE INSTALLING NEW BLOCKING. ADD NEW P.T. WOOD NAILERS AS REQUIRED TO MATCH NEW INSULATION HEIGHT. 4. NEW ROOF DRAINS ARE TO BE FURNISHED AND INSTALLED WHERE SHOWN ON DRAWINGS. CONNECT TO EXISTING DRAINLINES. KEEP DRAINLINES CLEAR OF DEBRIS DURING TEAR-OFF AND WHILE INSTALLING THE NEW ROOF SYSTEM. CONTRACTOR TO CLEAR ANY BLOCKED EXISTING DRAINLINES. 5. WHEN USING CARLISLE/ FIRESTONE ROOFING SYSTEMS, FIELD SEAMS ARE TO RECEIVE BATIEN STRIP FLASHING IN ADDITION TO MANUFACTURER'S REQUIRED SEAM FLASHING DETAILS. G. EXISTING ROOF HATCH IS TO RECEIVE NEW HASP HARDWARE TO PROVIDE A LOCKABLE CLOSURE. 7. THE EXISTING CHIMNEY COPPER REGLET IS TO REMAIN. REVISE AS REQUIRED TO EXCEPT NEW COUNTERFLASHING. ----."~--3'-4" " 1 EXISTING CHIMNEY CAP DIM. 1 VERIFY IN FIELD. EXISTING LIGHTNING ROD ------$ ARRESTING CABLE TO BE RAISED $ RESET ONTO NEW COFFER CHIMNEY CAP EXTEND COPPER CAP UP AND INTO FLUE ~::::;}-NEW 20oz. RED COFFER CHIMNEY CAF w/ HEMMED DRIP EDGE EXTEND COPPER CAP UP AND INTO FLUE CHIMNEY CAP DETAIL -9 ALTERNATE NO. I A. I SCALE 3/4" = I '-0" . 0 lL z 0 u.J f2 ~ ~z u.J ~ 0.... u.J 0.... ~ ::) <( lL D 0-0 co ~ u.J s tf) 0 <( _J co EXISTING I" 0 CABLE TO BE RAISED $ RESET 0 EXISTING LIGHTNING ARRESTING CABLE TO BE RAISED $ RESET G" P.T. BLOCKING FULL PERIMETER GENERAL NOTES: I. CONTRACTOR TO VERIFY ALL DIMENSIONS IN FIELD. 2. DRAWINGS COMPILED FROM DRAWINGS BY ALDERMAN$ MAC NEISH, ARCHITECTS and ENGINEERS, 594 RIVERDALE ROAD, WEST SPRINGFIELD, MA, DATED MAY I , I 972 AND FROM FIELD MEASUREMENT. 3. CONTRACTOR IS TO RAISE EXISTING ROOF TOP ANTENNA CABLES ON UPPER ROOF TO ALLOW DEMOLITION OF EXISTING ROOF AND INSTALLATION OF NEW ROOFING SYSTEM AND SET BACK DOWN WITHOUT INTERRUPTION OF SERVICE TO THE OWNER. 4. THE EXISTING LIGHTING ARRESTING SYSTEM CABLE ON UPPER ROOF IS TO BE RAISED TO ALLOW DEMOLITION OF EXISTING ROOF AND INSTALLATION OF NEW ROOFING SYSTEM AND SET BACK DOWN WITHOUT INTERRUPTION OF SERVICE TO THE OWNER. 5. THE CONTRACTOR IS TO BE AWARE OF WALL MOUNTED ANTENNAE AND GENERATOR EXHAUST PIPING ADJACENT TO THE UPPER ROOF AREA WHICH IS NOT TO BE DISTURBED DURING CONSTRUCTION. 91_011 ~I"--------+---------741_ 111 -----------",~----\----,f--91_ 111 --~ ' -LO --y-,-<( lLJ i'--I ' ~ llJ ti i'---lLJ O tf) ~ I-lLJ <( "1 !'L I 12'-o" <.') ~ .... zITT O -lLJ lLJ I-_J tf) tf) llJ --<( ~ G" ~u t::: WMA 8'-1 O" (FACE F BRICK ELOW) Ul ' co LO WMA + ,-7 '-Z_ t 1/8" ---SB/WP NRD I I .. I I I @ I I ---+-----+-+-I G'-0" I I I I I .. p~ @ FLAT t 1/8" 81-011 SCUP HP 1/8" FLAT @ 1/8" HP @ SB/WP 1/8" TEST CUT NO. I 1/8" .. ROOF PLAN -FLORENCE FIRE STATION SCALE l /811= l 1-011 ~ _, LO i'--NORTH ' i'---E I \ 112" I - - - -_J ---'I.-s @I I G" P.T. BLOCKING I FULL PERIMETER 1/ I I I LEGEND NRD = NEW ROOF DRAIN PV = PLUMBING VENT _ __.,_ = DIRECTION OF DOWNWARD PITCH ~ = NEW INSULATION CRICKET HP = HIGH POINT NSCUPR = NEW WALL MOUNTED SCUPPER @ = INSULATION THICKNESS AT LOCATION LAP = LOUVERED ALUMINUM PENTHOUSE WMEV = WALL MOUNTED EXHAUST VENT WMA = WALL MOUNTED ANTENNA EV = EXHAUST VENT PP = PITCH POCKET SB/WP = SPLASH BLOCK w/ WALK PAD TEST CUT LEGEND TEST CUT NO. I IS\ TEST CUT RESULTS LOWER ROOF LEVEL 'C__) AT INDICATED LOCATION: ... EXISTING EPDM MEMBRANE OVER I /2" RECOVERY BOARD INSULATION OVER B.U.R. ROOF MEMBRANE OVER I 1/2" FIBERGLASS INSULATION OVER METAL DECK. TOTAL THICKNESS 2 1/2". z 0 I-~ ::::l u lLJ tf) ~ IL _J ::::l IL s <S) <( _J ~ 0 u I-I-lLJ u lLJ ~ --, llJ I: ::::l tf) ~ z 0 tf) <{ LO tf) a, L z 0 !'L lLJ :s: -0 IL D O O UJ z 0 <( <( U) ('() lLJ oi8L~C'\! r= !'L . U) s COz:;;fuim I-.0<(~[0 ::::l <S) ~ ~ (I') ('() 0 :r:: I->-Brostst s ~ LO ~ :C ~ <.') z c() 0..... lL >-IL 0 u lLI ~ 0 (D z 0 (D > lLI Di lLI ~ -0 0 I U) t'--0 I -t'--~ ~ 0 u Qi' 0 lLI 0 z I: ,L ro f-IL [! u tf) u lLI z lLI -, ~ ·"1 --;L ~ ~ ~<') ~?d i<!z ~:, ~« 0 0 0..... SHEET A. I 3 OF (\J 'It, UJ NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. I ~-CONTINUOUS METAL HOOK STRIP MIN. 22 GAUGE. FASTEN USING GALVANIZED ANNULAR RING NAILS. WHEN SCREWS ARE USED THEY SHOULD BE NO. 8 MIN. AND PENETRATE WOOD NAILER 3/4 IN. FASTEN TWO ROWS I IN. FROM TOP AND I IN. FROM BOTIOM OF HOOK STRIP. (SEE NOTE 3) ~-SARNACLAD METAL FASTENED I IN. FROM BACK EDGE AT 4 IN. O.C. STAGGERED USING SARNAFASTENER SCREWS. (SEE NOTE 2) ~-SARNAFIL 80 MIL FLASHING STRIP, HOT-AIR WELDED PRESSURE TREATED WOOD NAILERS. HEIGHT TO MATCH INSULATION. (SEE NOTE I) SEE ROOF PLAN FOR INSULATION THICKNESS FOR EACH ROOF AREA. SARNAFIL .080 MEMBRANE ADHERED, w/ AC FORM IV INSULATION, BASE LAYER MECHANICALLY ATIACHED AT METAL DECK ONLY, TOP LAYER FULLY ADHERED SARNVAP SA VAPOR BARRIER --SARNACLAD PVC COATED METAL ... 1/4 INCH GAP --MIN. I -INCH GALVANIZED ANNULAR RING NAILS FASTENED 4 INCHES O.C., STAGGERED OR OTHER ACCEPTABLE FASTENER --4 INCH WIDE 80 MIL FLASHING STRIP, HOT-AIR WELDED IN PLACE 2-INCH WIDE ALUMINUM TAPE OVER JOINT 4" NEW DRAINS TO BE INSTALLED WHERE SHOWN ON ROOF PLAN C.I. DRAIN STRAINER CLAMPING RING SARNAFIL .080 MEMBRANE FLASHING ADHERED TAPERED EDGE SECURELY ADHERED AS REQUIRED SARNAFIL .080 G4 IO MEMBRANE ADHERED, w/ AC FOAM IV INSULATION TAPERED TO SUMP, BASE LAYER MECHANICALLY TO METAL DECK HOT-AIR WELD SARNVAP SA VAPOR BARRI ER EXISTING METAL DECK TO REMAIN z :::;; z z :::;; ... VI L.,J I u z OJ EXISTING LOUVERED ALUMINUM PENTHOUSE TO REMAIN. CAREFULLY BEND UP EXISTING METAL FLASHINGS TO ACCEPT SARNAFIL 80 ,/ MIL FLASHING MEMBRANE. \ t:®L-I"\ NEW PRESSURE TREATED BLOCKING AS REQUIRED I \ I ' II GROMMITTED FASTENER I 2 INCHES O.C. ~,----~-METAL EXTENDER PIECE WITH SARNAFIL SEALANT ONTO BACK SIDE SARNAFIL 80 MIL FLASHING MEMBRANE ADHERED TO ACCEPTABLE SUBSTRATE ~-HOT-AIR WELD I SARNAFIL .080 MEMBRANE ADHERED, , w/ AC FORM IV INSULATION, BASE LAYER llL.. MECHANICALLY ATTACHED AT METAL DECK a \-<:() 0 z UJ UJ NOTE: FOR ADDITIONAL INFORMATION RIEFER TO SARNACLAD METAL EDGE DETAIL MA-I . I NOTE: ~-SARNAFIL SEALANT UNDER MEMBRANE AT CLAMPING RING 1,......... ONLY, TOP LAYER FULLY ADHERED -=---+-I-I -------!D. FLASHING AT I) SARNAFIL G459 MEMBRANE CAN BE USED IN AREAS OF ASPHALT CONTAMINATION. la SARNACLAD METAL JOINTS 2) DRAIN SUMPS TO BE 4'-0" SQUARE TYPICAL WITH INSULATION THICKNESS AT SUMP EDGE OF 2". A. I NOT TO SCALE @TYPICAL ROOF DRAIN DETAIL A. I MULTI-PURPOSE TAPE EXISTING METAL DECK TO REMAIN EXISTING CONCRETE-+------PANEL TO REMAIN NOTES: I) WOOD NAILER5 SHALL BE ATTACHED ACCORDING TO THE DESIGNERS SPEC. OR LOCAL CODE, WHICHEVER 15 MORE STRINGENT. 2) MAXIMUM "L" DIMENSIONS SHALL BE 7 IN. FOR F.M. I -GO, AND 5 IN. FOR F.M.1-:30 SYSTEMS. 3) WITHDRAWAL RESISTANCE SHOULD BE I 00 LB PER NAIL MIN. FOR HOOK STRIP. ANNULAR RING NAILS SHOULD PENETRATE 1-1/4 IN. INTO WOOD NAILER. 4) EXISTING WOOD NAILER5 SHALL BE SECURED PER FACTORY MUTUAL LOSS PREVENTION DATA SHEET 1-4:3 RECOMMENDATIONS. 5) FOLLOW FACTORY MUTUAL LOSS PREVENTION DATA SHEET 1-4:3 RECOMMENDATIONS. G) POSITION THE SARNAFIL .. 080 MIL MEMBRANE (NON-FELTED) OVER THE ROOF EDGE AND DOWN OUTSIDE FACE OF WALL, COVERING TREATED WOOD NAILER(S) COMPLETELY. SARNACLAD METAL EDGE DETAIL A. I (FOR WIND SPEEDS GREATER THAN OR EQUAL TO ee M.P.H.J NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. I NEW 5ARNACLAD METAL SCUPPER BOX NOTES: SARNACLAD METAL FASTENED I IN. FROM BACK EDGE AT 4 IN. O.C. STAGGERED USING SARNAFASTENER SCREWS. (SEE NOTE 2) I) PIECE OF SARNACLAD METAL CUT TO FIT INSIDE OF VOID AT OPEN END OF GRAVEL -DAM, SECURJED IN-PLACE USING POP-RIVETS PRIOR TO COMPLETING FLASHINGS AT SCUPPER BOX 2) VAPOR BARRIER SHALL BE SEALED AT EDGES SARNASTOP FASTENED AT BASE OF WALL OR CURB ALTERNATE BASE FASTENING SARNAFIL WALKWAY OR SARNAPAD WELDED TO ROOF MEMBRANE REFER TO ABOVE DETAIL -fl-SEE ENLARGED -----i---. TERMINATION DETAIL THIS SHEET SARNACLAD MET.A .. L=---\-----'~ DOWNSPOUT w/ -ELBOW NEW ADHERED PVC SPLASH BLOCK -~---SARNAFIL 80 MIL FLASHING STRIP, HOT-AIR WELDED I --PRJESSURE TRJEATED WOOD NAILERS. HEIGHT TO MATCH INSULATION. (SEE NOTE I) 5ARNAFIL .080 MEMBRANE ADHERED, w/ AC FORJV IV INSULATION SECURELY ADHERED, SLOPED TO SCUPPER -SARNVAP SA-~ VAPOR BARJRI ER MULTI-PURFOSE L.-t---T APE I <{J EXISTING CONCRETE DECK TO REMAIN EXISTING BRICK MASONRY WALL TO REMAIN 1'--'s----=--+-".--.-'--"s----=-----, SARNAFIL .080 MEMBRANE ADHERED, ----=.-'--"s----=--+-".-----=,'-',I w/ AC FORM IV INSULATION, BASE LAYER MECHANICALLY ATTACHED, TOP LAYER FULLY ADHERED EXISTING METAL ---1--DECK TO REMAIN SARNVAPSA----==--------------1 NOTES: V APOR BARJRI ER I) METAL EXTENDER PIECE 15 REQUIRED IF EXISTING COUNTERFLASHING 15 CONTAMINATED AND OR COUNTERFLASHING FASCIA 15 LESS 4 INCHES WIDE. 2) VAPOR BARJRIER SHALL BE SEALED AT EDGES. SARNACLAD SCUPPER DETAIL NOT TO SCALE NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. EXISTING C.I. VENT PIPE TO BE SCRAPED, PRIME ,t. PAINTED WITH RUSTOLEUM PAINT, COLOR WHITE f-:r:: <.') lLJ :r:: a:: 9 -lLl ""' lL <( z >-z 2 SARNAFI L BASE o::i FLASHING, HOT-AIR WELDED~ NEW PT WOOD NAILERS SARNVAP SA VAPOR BARRIER EXISTING CONCRETE DECK TO REMAIN PIPE PENETRATION @FLASHING DETAIL A. I EXISTING CONCRETE --SARNAFIL SEALANT (SEE NOTE) STAINLESS STEEL HOSE CLAMP ALUMINUM TAPE (SEE NOTE) SARNAFIL 80 MIL FLASHING MEMBRANE SARNAFASTENER AND SARNADISC SARNAFIL .080 MEMBRANE ADHERED, w/ AC FORM IV INSULATION, BASE LAYER MECHANICALLY ATTACHED AT METAL DECK ONLY, TOP LAYER FULLY ADHERED EXISTING METAL DECK TO REMAIN SARNVAP SA VAPOR BARRI ER NOTES: I) ALUMINUM TAPE 15 REQUIRED IF EXISTING PENETRATION 15 CONTAMINATED. 2) SEALANT 15 A MAINTENANCE ITEM, MAINTENANCE 15 NOT COVERED UNDER THE SARNAFIL WARRANTY. PANEL TO REMAIN :----------j__ 5ARNAFIL SEALANT TO CLEAN SURFACE ~-------1:;p====;====~ MULTI-PURPOSE TAPE ---OR 5ARNAFIL SEALANT ----5ARNAREGLET FASTENED 8 INCHES O.C. WITIH GROMMETTED FASTENERS 5ARNAFIL FLASHING TO --ACCEPTABLE SUBSTRATE 5ARNASTOP AND SARNAFASTENERS -~ HOT-AIR WELD ---SARNAFIL G4 IO --MEMBRANE, ADHERED NOTES: EXISTING METAL DECK TO REMAIN --EXISTING BRICK MASONRY WALL TO REMAIN I) SEALANT 15 A TWO STEP APPLICATION: A) BEHIND TOP OF SARNAFIL FLASHING B) AND AT TOP OF SARNAREGLET. CJ SEALANT SHALL BE APPLIED TO 2) SEALANT 15 A MAINTENANCE ITEM. MAIN-TENANCE 15 NOT COVERED UNDER THE SARNAFIL WARRANTY. CLEAN ACCEPTABLE SURFACE. 3) VAPOR BARRIER SHALL BE SEALED AT EDGES. G SARNAREGLET TERMINATION A. I SARNAFIL ROOF DETAILS SCALE: 311 = l 1-011 (UNLESS OTHERWISE NOTED) SARNAFIL .080 MEMBRANE ADHERED, w/ AC FORM IV INSULATION, BASE LAYER FULLY ADHERED, TOP LAYER FULLY ADHERED SARNACLAD METAL PITCH PLAN FASTENED 4 IN. 0. C. USING GALVANIZED ANNULAR RING NAILS ,------='-------=---OR OTHER ACCEPT ABLE FASTENERS z ::;: z [() SARNAFIL FLASHING HOT-AIR WELDED NEW P.T. WOOD NAILERS TO MATCH INSULATION HEIGHT EXISTING CONCRETE DECK TO REMAIN NOTES: --+--WEATHERHEAD/ ANTENNA MAST ---2 INCHES MIN. SARNAFILLER PITCH POCKET SEALANT CEMENT BASED GROUT SARNVAP SAJ VAPOR BARRIER I J PITCH POCKETS ARE TO BE ELIMINATED WHERE POSSIBLE. 2) SEALANT 15 A MAINTENANCE ITEM. MAINTENANCE 15 NOT COVERED UNDER THE SARNAFIL WARRANTY. @PITCH POCKET DETAIL -ALTERNATE NO. A. I METAL CURB (OPTIONAW FIBERGLASS BATIEN -~ STAINLESS STEEL HOSE CLAMP EXISTING HOT STACK RAIN COLLAR WITH HIGH TEMPERATURE SEALANT SARNAFIL FLASHING MEMBRANE SARNAFA5TENER AND SARNADISC SARNAFIL BASE FLASHING HOT-AIR WELDED NEW F.T. WOOD NAILERS SARNAFIL .080 MEMBRANE ADHERED, w/ AC FORM IV INSULATION, BASE LA\'!'R MECHANICALLY ATIACHED, TOF LAYER FULLY ADHERED EXISTING METAL DECK TO REMAIN SARNVAP SA VAPOR BARRIER NOTES: I) SARNAFIL MEMBRANE SHALL NOT BE IN CONTACT WITH SURFACES HAVING SUSTAINED TEMPERATURES ABOVE fGO F. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES 8 HEATED STACK FLASHING DETAIL A. I NOT TO SCALE 1 t----;'--",c--r"<c--+-cr'<c"-~,..,._.-~.....,...----,'-'c-----,''-'c--1 L EXISTING METAL DECK TO REMAIN NOTES: SARNVAP SA VAPOR BARRIER I J METAL EXTENDER PIECE 15 REQUIRED IF EXISTING COUNTER.FLASHING 15 CONTAMINATED AND OR COUNTERFLASHING FASCIA 15 LESS THAN 4 INCHES WIDE. FASTENED I 2 INCHES O.C. WITH GROMMITTED FASTENER. 2) VAPOR BARRIER SHALL BE SEALED AT EDGES 3 LOUVERED ALUMINUM PENTHOUSE FLASHING A. I NOTE: FOR SARNAFIL ROOFING ON THE UPPER ROOF AREA ONLY, (ALTERNATE NO. I), THE BASE LAYER OF INSULATION IS TO BE FULLY ADHERED AS WELL AS THE UPPER LAYERS. NOTES: SARNAFIL MEMBRANE 2 INCH WIDE G4 IO MEMBRANE STRIP, HOT-AIR WELDED IN PLACE EVERY I 2 IN. O.C. SARNAFIL .080 MEMBRANE ADHERED, w/ AC FORM IV INSULATION, BASE LAYER FULLY ADHERED, TOP LAYER FULLY ADHERED ~-AIR/ VAPOR BARRIER (AS REQUIRED) LIGHTNING ROD CABLE 2 INCH WIDE SARNAFIL G4 I 0 MEMBRANE STRAP ( I 2 IN. O.C.) HOT-AIR WELD EXISTING CONCRETE DECK TO REMAIN I) EXISTING CABLE SHALL BE CLEANED FREE OF ASPHALT CONTAMINATION AS REQUIRED PRIOR TO REINSTALLATION. 2) IF ASPHALT CONTAMINATION CAN NOT BE CLEANED, SARNAFIL REQUIRES A CONTINUOUS G459 FLASHING STRIP UNDER LOCATION OF CABLE. HOT-AIR WELDED IN-FLACE. 3) SARNAFIL 15 NOT RESPONSIBLE FOR LIGHTNING DAMAGE TO SARNAFIL ROOF. 4) VAPOR BARRIER SHALL BE SEALED AT EDGES. LIGHTNING ROD CABLE NOTTO SCALE z 0 ~ I-:::) u \LI (/) 0 DL {L -' :::) lL t.n l -' I-0 u I-I-lLJ u I-\LI -, a'.l I: :::) (/) ~ z 0 (/) <( lI) (/) z (;) 2 0 DL \LI :s - 0 {L D O O UJ z ~ <( <( U) ('() \LI i2 L ~ ~ ~ DL co • U) s z :i U) (;) 0 <( (;) lI) I-:::) t.n lf) lI) . 0 _J :c . ('() ~('()-:c :c -s;r I->-s <...) rO s;t-~m~:c~ <..') z c() 0.... lL >-{L 0 u ll.J ~ 0 (f) z 0 -(f) > ll.J llL ll.J ~ -0 0 I U) 1'-0 I -1'-r::: ;,::'. 0 u ~ 0 ll.J 0 z I: ;L a'.l f-{L g;i u (/) u ll.J z ll.J -, ~ ·o'. ---;L ~ ~ ~'-' ~?2 ~z ~2 ~« Q 0 (L SHEET A.2 3 OF NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. C\J "' tu • f-"' 0 z I" MIN. 1/4" MAX. CONTINUOUS BEAD OF ECOWHITE LAP SEALANT (REQUIRED) P. T. WOOD NAILERS (SEE NOTES) I - I /4" HOT DIPPED GALVANIZED ROOF NAILS AT b" O.C. MAX. 1-3/4" STAINLESS STEEL RINGSHANK 5D COMMON NAILS AT 8" O.C. MAX. 1-3/4" STAINLESS STEEL RINGSHANK 5D COMMON NAILS AT 4" 0.C. MAX., 1/2" STAGGERED 9" QUICKSEAM FORMFLASH 5" QUICKSEAM FLASHING QUICKPRIME PLUS .090" PLATINUM EPDM MEMBRANE BONDING ADHESIVE CONTINUOUS BEAD OF LAP SEALANT (SEE NOTES) FIRESTONE 150 55 + GL . ' . . . 5" QUICKSEAM FLASHING CENTERED OVER LAP SPLICE (SEE NOTES) 3" QUICKSEAM SPLICE TAPE (SEE NOTES) .090" PLATINUM EPDM MEMBRANE BONDING ADHESIVE NOTE: SIMILAR WORK FOR ROOF 15 PART OF ALTERNA-1/B" TO 1/2" QUICKPRIME PLUS .090" PLATINUM EPDM MEMBRANE FIRESTONE 150 95 + GL STRAINER BASKET COMPRESSION RING CONTINUOUS BEAD OF FIRESTONE WATERBLOCK (SEE NOTE5) BONDING ADHESIVE 12" G" MAX. c:::=--== NOTES, I. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. HOLE IN MEMBRANE SHOULD EXTEND A MINIMUM OF 1/2" BEYOND CLAMPING RING AND SHOULD NOT BE SMALLER THAN THE DIAMETER OF THE LEADER PIPE. 3. INSULATION ADJACENT TO DRAIN TO BE APPROPRJATE FIRESTONE INSULATION WITH APPROPRJATE BONDING SURFACE. 4. FIRESTONE WATERBLOCK MIN. OF 1/2 OF 10 OZ TUBE FER 4" DRAIN. USE ADDITIONAL WATERBLOCK FOR LARGER DRAJNS. 5. IN REROOF APPLICATIONS, -REMOVE EXISTING FLASHINGS DOWN TO METAL BO\/vl -REPAIR OR REPLACE BROKEN DRAJN COMPONENTS -DRILL AND TAP BROKEN DRAIN BOLTS AND REPLACE IF NECESSARY. EXISTING LOUVERED ALUMINUM PENTHOUSE TO REMAIN. CAREFULLY BEND UP EXISTING / METAL FLASHINGS TO ACCEPT EPDM / FLASHING MEMBRANE. IJLWJ----t~,-NEW PRESSURE TREATED BLOCKING AS REQUIRED ,_,__---1-__;\~GROMMETIED FASTENER I 2 INCHES O.C. ' L-------METAL COUNTERFLASHING PIECE w/ SEALANT ONTO BACK SIDE ILl UNA-EDGE GS METAL ILl SYSTEM (SEE NOTES) !cl INSULATION, BA5E LAYER MECHANICALLY ATIACHED, TOF LAYER FULLY ADHERED INSULATION, BA5E LAYER MECHANICALLY ATIACHED, TOF LAYER FULLY ADHERED }.090 PLATINUM MEMBRANE ADHERED J,c--7-'c---7--j w/ FIRESTONE 150 95 + GL INSULATION "'""'----QUICKSEAM RPF STRIP ----QUICKPRIME PLUS NOTES, I. REFER TO FIRESTONE WEBSITE FOR M05T CURRENT INFORMATION. CONTINUOUS CLEAT EXl5TI NG CONCRETE FANEL TO REMAIN V-FORCE EXISTING METAL DECK TO REMAIN V-FORCE VAPOR BARRIER EXISTING METAL DECK TO REMAIN NOTES, I. REFER TO FIRESTONE WEBSITE FOR M05T CURRENT INFORMATION. 2. END LAF5 OF QUICK5EAM 5FLICE TAFE MU5T OVERLAF A MINIMUM OF I" 3. END LAF5 OF 5" QUICK5EAM FLASHING MU5T OVERLAF A MINIMUM OF 3". REFER TO FL5-5. BASE LA.YER MECHANICALLY ATTACHED, """"""'~""'=='o-. TOP LAYER FULLY ADHERED SLOPED TO EXISTING UGHTWEIGHT CONCRETE DECK TO REMAIN SUMP AREA FIELD SEAM REQUIREMENTS, V-FORCE DRAIN. VAPOR BARRJER A. IF FIELD SEAM EDGE IS WITHIN 5" OF DRAIN COMPRESSION RING, PLATINUM EPDM TARGET PATCH REQUIRED. 111 Lu ::c u z "' BONDING ADHESIVE FIRESTONE FASTENER AND 2" METAL PLATE AT I 2" O.C. MAX. (SEE NOTES) 2. MAXIMUM G" LONG FA5TENER5. (NOTE, WOOD BLOCKING MAY BE 5UB5TITUTED FOR INSULATION TO REDUCE FASTENER LENGTH REQUIREMENT). .090" PLATINUM EPDM MEMBRANE lb LAP SPLICE DETAIL @ROOF DRAIN DETAIL A. I A. I FIRESTONE METAL EDGE DETAIL NOTES: I. REFER TO FIRESTONE Vl/EB51TE FOR MOST CURRENT INFORMATION. 2. 9" QUICKSEAM FORMFLASH MUST EXTEND TO WITHIN 1/4" OF THE METAL EDGE. 3. INSTALL METAL WORK TO FIRESTONE INSTALLATION INSTRUCTIONS. 4. LAP SEALANT 15 REQUIRED ALONG UPSLOPE EDGE OF QUICKSEAM FLASHING WHEN ROOF SLOPE 15 I" PER FOOT OR GREATER. REFER TO PLS-4 FOR SEAM EDGE TREATMENT. 5. WOOD NAILERS MUST BE INSTALLED TO MEET APPLICABLE BUILDING CODES OR 200 LBS PER LINEAR FOOT MINIMUM IN ANY GIVEN DIRECTION. G. FLANGE OF METAL MUST BE FULLY SUPPORTED BY WOOD AND TERMINATED AT LEAST 1/2" FROM EDGE OF WOOD. A. I SecurEDGE I PIECE GRAVEL STOP BEYOND 7 I -3/4" STAINLESS STEEL RINGSHANK SD COMMON NAILS AT 8" O.C. MAX. NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. 6-, l"MIN. 1:: ', 3" WIDE SURE-SEAL SecurTAPE TO BE USED REFER TO MANUF. DETAIL FOR MEMBRANE SPLICE WITH SecurTAPE. NOTE, SEAM STRJP MUST BE APPLIED AT FLASHING AND TAPE OVERLAPS AND INTERSECTIONS WITH FIELD SEAMS OR JOINTS IN METAL EDGING. 1/4" MAX. CONTINUOUS BEAD OF LAP SEALANT (REQUIRED) NEW TREATED WOOD NAILERS -ll-------MATCH INSULATION HEIGHT ALUMINUM SCUPPER BOX ANCHORED TO ____.,,., WOOD NAILER ~ ALUMINUM DOWNSPOUT ----J------.-. w/ ELBOW SEE LOW WALL COUNTERFLASHING TERMINATION DETAIL FOR ADDITIONAL NOTES FIRESTONE WALKWAY PAD ADHERED TO ROOF MEMBRANE I I / I -3/4" STAINLESS STEEL RJNGSHANK SD COMMON NAILS AT 4" O.C. MAX., 1/2" STAGGERED .090 PLATINUM MEMBRANE ADHERED w/ FIRESTONE 150 95 + GL INSULATION 5" QUICK5EAM FLASHING BASE LAYER MECHANICALLY ATIACHED, QUICKPRIME PLUS TOP LAYER FULLY ADHERED SLOPED TO SCUPPER-----~ .090" PLATINUM EPDM MEMBRANE ----------1-____j BONDING ADHESIVE CONTINUOUS BEAD OF LAP SEALANT (SEE NOTES) V-FORCE VAPOR BARRIER EXISTING CONCRETE DECK TO REMAIN .090" PLATINUM \ \ EPDM MEMBRANE 4 A. I NEW ADHERED PVC SPLASH BLOCK V-FORCE VAPOR BARRIER EPDM SCUPPER DETAIL NOT TO SCALE EXISTING METAL DECK TO REMAIN GENERAL NOTE: "'--/ EXISTING BRICK ASONRY WALL TO REMAIN WHEN USING CARLISLE/ FIRESTONE EPDM ROOFING SYSTEMS, FIELD SEAMS ARE TO RECIEVE BATTEN STRIP FLASHING IN ADDITION TO MANUFACTURER'S REQUIRED SEAM FLASH I NG DETAILS. NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. CONTINLIOLl5 BEAD OF LAP SEALANT (5EE NOTE5) CONTINUOUS BEAD OF LAP SEALANT (SEE NOTE5) QUICKPRIME PLUS CONTINUOUS BEAD OF LAP SEALANT (5EE NOTE5) EX15TI NG CONCRETE DECK TO REMAIN L EXISTING C.I. VENT FIFE TO BE SCRAPED, FRIME $ PAINTED WITH RU5TOLEUM FAINT, COLOR BLACK 5/5 CLAMPING RING PRE-MOLDED QLJICK5EAM PIPE FLASHING .050 PLATINUM EPDM MEMBRANE I 2" QUICK5EAM FORMFLA5H BONDING ADHESIVE 3"1 FIRESTONE 150 95 + GL INSULATION BASE LAYER MECHANICALLY ATTACHED, TOP LAYER FULLY ADHERED EXISTING METAL DECK TO REMAIN V-FORCE VAFOR BARRER 5 PRE-MOULDED VENT PIPE FLASHING A. I NOTES, I. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. REMOVE ALL EXISTING FLASHINGS, LEADS, ETC. PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC. 3. PIPE MUST BE ANCHORED TO ENSURE STABILITY. 4. PRE-MOLDED QUICKSEAM PIPE FLASHING MAY BE CUT TO HEIGHT, BUT NO LOWER THAN REINFORCING RING ( NO WRJNKLES OR FOLDS UNDER CLAMPING RJNG). CONTINUOUS BEAD OF FIRESTONE AP SEALANT EXISTING CONCRETE OR HIGH-GRADE DECK TO REMAIN URETHANE SEALANT Fl RESTO NE ----\----'1 TERMINATION BAR APPROPRIATE FIRESTONE FASTENER I 2" O.C. MAX. CONTINUOUS BEAD OF FIRESTONE WATERBLOCK METAL COUNTERFLASHING 3" MIN. FACE (SEE NOTES) .050" PLATINUM MEMBRANE, .OGO RUBBERGARD MEMBRANE MEMBRANE OR QUICKSEAM CURB FLASHING AS REQUIRED BONDING ADHESIVE ---Ill USE APPROPRJATE EXISTING BRICK MASONRY WALL TO REMAIN BASE TIE-IN---.ll!L ___ ...f\~---..L 5. 12" QUICKSEAM FORMFLASH EXTENDING 1/4" FROM FIFE FLASHING WALL TO 3" BEYOND PIPE FLASHING. REFER TO PP-8 FOR ADDITIONAL APPLICATION INFORMATION AND OPTIONS. G. APPLY LAP SEALANT BETWEEN PENETRATION AND PRE-MOLDED PIPE FLASHING PRIOR TO INSTALLATION OF CLAMPING RJNG. REFER TO PLS-4 FOR SEAM EDGE TREATMENT. 7. PRE-MOLDED PIPE FLASHING FITS I" -G" PENETRATION SIZES. 8. DO NOT USE WHEN SERVICE LINE TEMP EXCEEDS I 80°F. REFER TO PP-4. NOTES, I. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. 2. WATER BLOCK APPLIED AT THE RATE OF IO LINEAR FEET PER TUBE. 3. REGULAR MAINTENANCE OF COUNTERFLASHING AND SEALANTS REQUIRED. NOT INCLUDED AS PART OF THE FIRESTONE WARRANTY. 4. METAL COUNTERFLASHING SHALL BE 24 GAUGE PRE-FINISHED STEEL OR .032" MIN. ALUMINUM FORMED WITH HEMMED LOWER EDGE. 5. INSTALL FIRESTONE TERMINATION BAR WITH 1/4" GAP BETV\/EEN ADJOINING SECTIONS. G. TERMINATION BAR MUST BE CUT AT INSIDE AND OUTSIDE CORNERS. DO NOT BEND AROUND CORNERS. -7. TERMINATION BAR MUST BE FASTENED WITHIN I" MAX. OF ALL SECTION ENDS. 8. INSTALL METAL WORK IN ACCORDANCE WITH CURRENT SMACNA RECOMMENDATIONS. G LOW WALL COUNTERFLASHING TERMINATION A. I NOT TO SCALE EPDM ROOF DET Al LS SCALE: 311 I 1_011 (UNLESS OTHERWISE NOTED) NOTE: WORK FOR UPPER ROOF IS PART OF ALTERNATE NO. CONTINUOUS BEAD OF LAP SEALANT (SEE NOTES) I 2." QUICK.SEAM F0RMFLA5H QUICK.PRIME FLUS (SEE NOTES) FIRESTONE 150 95 + GL INSULATION BASE LAYER MECHANICALLY ATIACHED, TOP LAYER FULLY ADHERfD NOTES, EXISTING CONCRETE DECK TO REMAIN I . REFER. TO FIRESTONE WEBSITE FOR MOST CUR.RENT INFORMATION. 2. REMOVJ: ALL EXISTING FLASHINGS, LEAD, ETC. PIPE SURFACE MUST Bl= FREE OF All RUST, GREASE, INSULATION, ETC. 3. DO NOT USE OVER EXISTING f'tNtTfi'ATION FOCl\"J::TS. 4. IF FIELD MEMBRANE 15 CUT FOR INSTAl..lATION, THE MEMBRANE MUST BE REPAIRED WITH CURtD EFDM PRIOR TO INSTAUATION INSTALLATION OF THE PENETRATION POCKET. 5. MEMBRANE MUST BE INSTALLED WITHIN 1/2." OF PENETRATION. EXISTING wtATHtRHtAD / -+--ANTtNNA MAST FIRESTONE POURABLE 5tAL.tR CUT PVC FIFE 05b PENETRATION POCl<l:T CONTINUOUS BEAD OF LAP SEALANT (5Ef N0Tf5} V-FORCE VAFOR BARRER b. FIRfSTONE POURABLE SEALER MOUNDED TO SHED WATER (MINIMUM DEPTH OF 2", REMAINDER OF POCKET MAY Bf FILLED WITH A NON-SHRINKING GROUT). 7. APPLY lAF 5EA1ANT AROUND ENTIRE F'tRIMETtROF FLASHING. RfftR TO Pl5-4 FOR SEAM EDGt TRtATMENT. B. QUICIQ"RIME PLUS REQUIRED ON PENETRATIONS AND MEMBRANE INSIDE OF PENETRATION POCKET. ';,. 00 NOT USE WHEN SERVICE LINE TEMP. EXCEEDS I B0° F. RfFER TO FP-4. EXISTING METAL DECK TO REMAIN V-FORCE VAPOR BARRIER 3 CURB FLASHING A. I NOTE: SIMILAR WORK FOR UPPER ROOF 15 PART OF ALTERNATE NO. I 5" QUICK5EAM FLASHING CENTERED OVER LAF LAP SPLICE (5EE NOTE5) 3" QLJICK5EAM 5FLICE TAFE (5EE NOTE5) .050" PLATINUM EFDM MEMBRANE BONDING ADHESIVE LIGHTNING ROD CABLE 2" WIDE MEMBRANE 5TRAF OF 5" QLJICK5EAM FLASHING ( 12 IN. O.C.) 1/8" TO 1/2" QUICKFRIME FLU5 INSULATION, BASE LAYER MECHANICALLY ATIACHED, TOP LAYER FULLY ADHERfD V-FORCE VAPOR BARRI ER EXISTING CONCRETE DECK TO REMAIN NOTE, I. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORMATION. @PITCH POCKET DETAIL -ALTERNATE NO. I A. I 9 A. I LIGHTNING ROD CABLE NOTTO SCALE AF SEALANT OR HIGH ----1-_J GRADE CAULKING FIELD FABRICATED ___ ,._ METAL HOOD QUICKFRIME FLU5 5" QUICK5EAM FLASHING <'---4-I /2" 2"---.r--~ PENETRATION (HOT 5TACK) (5EE NOTE5) 2-1/2" INSULATED METAL SLEEVE NOTES; I. REFER TO FIRESTONE WEBSITE FOR MOST CURRENT INFORN1ATION. 2. REMOVE ALL EXISTING FLASHINGS, LEAD, ETC. PIPE SURFACE MUST BE FREE OF ALL RUST, GREASE, INSULATION, ETC. 3. PENETRATION MUST BE ANCHORED TO ENSURE STABILITY. 4. CLAMPING RING AROUND TOP OF FORMFLASH NOT ACCEPTABLE. 5. Vi/HEN OUTSIDE DIAMETER OF THE PIPE EXCEEDS 18", ADDITIONAL FIELD MEMBRANE SECUREMENT RfQUIRfD. CONTINUOUS BEAD REFER TO APPROPRIATE BA5ETIE-IN DETA1l5. Of LAP 5EAIANT b. APPLY LAP SEALANT AROUND ENTIRE PERIMETER OF (5EE NOTE5) FLASHING. REFER TO PLS-4 FOR SEAM EDGE TREATMENT. 7. USE WHEN SERVICE LINE TEMP. EXCEEDS 180° F. 9" QUICK5EAM FORMFLASH CONTI NUOU5 BEAD OF LAF SEALANT (5EE NOTE5) .090" PLATINUM EFDM MEMBRANE BONDING ADHESIVE l!;;:?r,i=:=::::""'==::~~fAFIRE5T,ON~ 150 ~5 -i; GL IN,JU0TION B E LAYER MECHANICALLY ATIACHED, EXISTING METAL DECK TO REMAIN TOF LAYER FULLY ADHERED V-FORCE ® HEATED STACK FLASHING DETAIL A. I VAPOR BARRIER (f) 1-u lLJ I-r ~ <( z s ~ co IL! ~ 0 (f) z 0 -(f) > IL! {l," IL! ~ 0 ~ u IL! I: Di u a::l z ~ " Q SHEET . " ~<.'J i.iz IL 2 -0 I (J) I'-0 I -I'-r::: 0 ~ 0 0 z a::l f-)(2 u IL! IL! -, -;L ~ ~ :;a;:d IL<: 0 (l.... A.3 3 OF z 0 I-:::, u lLI § (L _J ::::, ~ 8 0 lLI ii3 ::::, ITT z 0 ITT ITT ~ lLI (L z lLI ~ Di s I-:::, 0 :r:: l-s 0 z t 0 u