gfn_pavilion_materials
Rattlesnake Gutter Timberworks Hank Silver 1 Rattlesnake Gutter Road Leverett, MA 01054 Email: HYPERLINK "mailto:hanksilver@rgtimberworks.com" hanksilver@rgtimberworks.com Mobile: 917-902-2998 Unrestricted CSL# 108530 Proposed Structure at: Approximately 140 Meadow Street Florence, MA 01062 As required by FEMA Technical Bulletin 2/ August 2008, this document provides a list of materials to be used in the proposed 16-foot by 22-foot open-air pavilion. FLOOR: Cast-in-place concrete – conforming FEMA TB-2, page 7 WALLS: 8x8 White Cedar posts – conforming FEMA TB-2, page 9 8x8 Eastern White Pine (EWP) top plates – conforming FEMA TB-2, page 9 8x10 EWP tie beams – conforming FEMA TB-2, page 9 1-inch Black Locust pegs – conforming FEMA TB-2, page 9 4x6 EWP & Black Cherry knee braces – conforming FEMA TB-2, page 9 ROOF: 5x7 EWP rafters – conforming FEMA TB-2, page 9 8x8 EWP king posts – conforming FEMA TB-2, page 9 6x8 EWP truss struts – conforming FEMA TB-2, page 9 1-inch EWP roof sheathing – conforming FEMA TB-2, page 9 29-gauge corrugated metal roofing – conforming FEMA TB-2, page 10 FASTENERS: All fasteners shall be of stainless steel or hot-dipped galvanized – conforming FEMA TB-2, page 12