Loading...
133 Glendale mod plumb PlansDefinition Of Terms -Builder,The purchaser, who is the contractual purchaser of goods from the company will provide a construction supervisor, duly licensed in accordance with 780 CMR R5, shall, in accordance with 780 CMR 108.3.5, act as the agent for the owner/purchaser for the purpose of applying for and obtaining any and all building permits required for the field erection of all one and two family manufactured dwellings subject to the provisions of 780 CMR 35 and applicable 780 CMR R3. The purchaser will be identified throughout this document as the "builder". All notes containing the term "by builder" are defining an obligation, for construction methodology/acceptable building practice for which the company accepts no responsibility, and should be reviewed carefully by the builder and the local building inspector. All such insta!lalion instruction will be in compliance with applicable building codes. -VM, For simplification, the manufacturer/supplier of the Thin:1 Party Inspected and Labeled modular component known as VERMOD HIGH PERFORMANCE MANUFACTURED HOUSING, LLC will be identified throughout this document as the "VM". -Local Building Code Official, the official having jurisdiction for issuing permits and site inspections. -Third Party Inspection Agency, T. R. Arnold & Associates, Inc. is an independent company approved by the state having jurisdiction to provide in plant inspections and labeling of the manufactured components. Specifications and Special Instructions ~ 1.0 FRAMING 1.1 Floors: 9 Y:," Wood "I" joist, T&G OSB sheathing glued and nailed with ring shank nails 1.2 Underside of 1st floor sheathed and taped with 7/16" Zip sheathing or GP Forcefield sheathing glued and nailed with ring shank nails 1.3 Exterior walls: double 2x4 SPF Stud Grade walls 24" OC, 1 O" thickness, 7 /16" Zip sheathing or GP Forcefield sheathing glued and nailed with ring shank nails 1.4 Roof system: 12· SIP's (Structurally Insulated Panels), 5/8" OSB sheathing, all soffits and facia installed 1.5 Interior partitions: 2x4 SPF Stud Grade @ 24" OC 1.6 Construction Stairs with temporary treads 2.0 ROOFING 2.1 EPDM rubber roofing complete with all flashings, plumbing boots, solar collector box installed 3.0 SIDING AND EXTERIOR TRIM 3.1 Double 4" vinyl siding M & L BY BUii DER 3.2 White accessory trim M & l . BY BUILD.ER 3.3 White 3" vinyl or Miratec corner boards M & L BY BUILD.ER 3.4 Miratec Facia with vinyl soffit, White 3.5 1x6 Miratec sand board (White) M & l BY BUil DER 3.6 Optional metal siding and deck prep M & l BY BUH DER 3.7 All exterior decks, porches, steps to grade M & l BY BUil DER 4.0 INS\ il AJIQN AND AIR SEAi ING 4.1 Fiberglass dense packed insulation 1st floor, rim of 1st floor ceiling to 2nd floor R 40, Walls R 43 4.2 Roof insulation SIPS panels -MA code compliant assembly 4.3 All exterior sheathing Joints sealed with Zip Tape or equal 4.4 All penetrations in exterior walls, ceilings and floors sealed 4.5 Windows and exterior doors sealed wlth tape and foamed in place 5.0 WINDOWS AND EXTERIOR DOORS 5.1 Vinyl casement and awning windows-foam filled frames, triple glazed argon filled, U.21 5.2 ThermaTru Smooth Star fiberglass doors with adjustable threshold and strike plate. Y:z glass back door, full glass front door 5.3 Brushed Chrome lever handles and hinges, deadbolts keyed alike 6.0 INTERIOR DOORS 6.1 6 panel or flush hollow core doors with 3 mortised hinges M. & L BY BUILDER 6.2 Satin Nickel Knobs M & l BY BUILDER 7.0 FINISHES 7 .1 5/8" sheetrock on all walls and ceilings taped and sanded 7.2 Vapor retarder primer on all walls and ceilings M & L BY BUILDER 7.3 BM Ultra Spec 500 flat latex paint "Linen White" on walls and ceilings· Zero voe White semi- gloss paint on doors and interior trim -Zero voe M & L BY BUILDER 7.4 Clear pine window sills and aprons M & L BY BUfLDER 7.5 2 W Colonial window/door trim w/ 3 %" baseboards or 2 Ya" Flat window/door trim w/ 4 Y." baseboards M & l BY BUILDER 7.6 Closet Maid wire shelving in all closets M & L BY Bil/I QER 7.7 Bamboo interlock flooring in all living spaces M & L. BY BUILDER 7.8 Vinyl interlock flooring in bathrooms, utility room, and laundry room M. & l BY BUILDER 7.9 Towel bar and toilet paper holder installed M & I BY BUILDER 7.10 Finish Stairs and railings M. & L. BYBWLDER Definition OfTerms PROJECT DATA -Delive~ Crew, responsible for road permits, r~ut~~ to site, ?nd es~ort vehicles I PROJECT: HABITAT FOR HUMANITY JOB: # 18229 for the delivery of the. modular co~ponents to their lifting location at. s!te. I LOCATION: LOT 4, 133 GLENDALE RD NORTHAMPTON MA 01062 -S~t Crew, respons,b.le for prepping the modular components for lifting and USE GROUP: R-3 landing on the. foundation. . . . CONSTRUCTION CLASS: SB -Crane Service, responsible for nggmg and placing the modular compcnents on AREA· 1 ST FLOOR· 602 f the founda!ion. Also resp~nsible for .safety while they ~re on site. · ZND FLOOR; 602 !r -The deta1~ and ln~truct1ons con)amed lh:oughout t~1s do.cument a'.e . . VOLUME: 13244 cf NUMBER OF FLOORS: 2 representative of. t~1cal construcl)on p'.actlce co11;ply1~g with recogmzed bull~1ng HEIGHT OF BUILDING FROM TOP OF FND . 22• codes. These bu1!dmg codes are hs!ed m the section t1tled "Referenced Bu1ld1ng . .. Codes•, however, local building codes may require special design consideration. OCCUPANC: LOAD PER FLOOR. (1 OCC. PER 200SF.) Consult your local building code official to review any required alternative details/ 1ST FLOOR. 3 PEOPLE materials (which deviate from the VM standards necessary for code compliance). 2ND FLOOR: 3 PEOPLE The details defining materials lo be supplied by the builder are for general WALL AND CEILING FINISHES: MAX FLAME SPREAD INDEX 75 guidance only and code compliance for such details are the responsibility of the MAX SMOKE • DEVELOPMENT INDEX 450 · builder. IN ACCORDANCE WITH ASTM E 84 / UL 723 ' -Structure Type: VerMod Components range from Single Box homes that are O HR. WALL CONSTRUCTION WlTH UNRATED 95% factory complete to Multi Box configurations that require far more site work. OPENINGS MIN. SETBACK FROM P~OPERTY See the BOX PROFILE to the right of this page. These diagrams will be used lo LINE TO DRIP LINE OF BUILDING: 6 focus detalls and site responslbilttles unique to the structure type. TYPE OF SUPPRESSION SYSTEM: NONE REQUIRED TYPE OF SMOKE DETECTOR: PHOTO ELECTRIC TYPE CARBON MONOXIDE ALARM: UL2034 M & I · Material and Labor 8.0 CABINETS AND COUNTERTQPS 8.1 JSI "Premier" series cabinets with dovetail drawers an undermount slides M & L BY BUILDER 8.2 Formica coi.mtertops with integral backsplash M & 1 BY BUILDER 18.3 Cultured marble vanity top with integral bowl (white) M..1!...L · BY BUILDER . 8.4 Chrome faucets M & I BY Btm DER 9.0 APPLIANCES 9.1 Energy Star Refrigerator M & l BY Bl/IL DER 9.2 Energy Star Dishwasher M & l BY B( Ill DER 9.3 Smooth top Electric Range M & L BY BUil DER 9.4 Microwave/hood over Range M & I BY BUH DER 9.5 Energy Star Washing Machine (white) M & I BYB/Jfl DER 9.6 Energy Star Condensing Dryer (white) M & I BYBU/1 DER 9.6.1 *Choice of white, black, or stainless steel* M & l BY BlfflDER 10.0 PLUMBING 1 10.1 PEX supply piping 10.1.1 Site connections: between boxes and boxes to site hook-ups M & L BY Blllf DER 110.2 Schedule 40 PVC waste lines BUILDER REQUIRED TO NOTIFY THE LOCAL AUTHORITY HAVING JURISDlCVON A MINJMUM OF 48 HOURS PRIOR TO DAYQFSET MANUFACTURER'S DATA Name: VerMod LLC Address: P.O. Box 566 Plant Address: 2677 Route 5 Wllder VT. 05088 Wilder VT 05088 · MAApproval: #566 ExpiraUon Date: 8-16-19 THIRD PARTY INSPECTION AGENCY DATA Name: TR Arnold & Associates, Inc. Address: 4703 Chester Drive, Elkhart, Indiana 46516 MA. Approval: 03 Expiration Date: 4-30-19 DATA PLATE & LABEL LOCATIONS DATA PLATE, 3rd PARTY LABEL, AND MA LABEL are located on the exterior wall Bedroom Closet BOX A 3rd PARTY LABEL, AND MA LABELS are located in BOX B Bedroom 2 Closet PROPRIETARY INFORMATION DRAWING INDEX SHT.# TITLE DATE LAST DRAWN REVISED CVR COVER 6/14/18 X A1.0 BASEMENT PLAN 6/14/18 A1.1 1ST & 2ND FLOOR PLAN 6/14/18 A2.1 1 ST FLOOR FRAMING & 1 ST CEILING 6/14/18 FRAMING A2.2 2ND FLOOR FRAMING & ROOF 6/14/18 FRAMING A3.1 TYPICAL SECTION & STAIR DETAILS 6/14/18 A4.1 ELEVATIONS 6/14/18 A5.0 FASTENING SCHEDULE 6/14/18 A5.1 TYPICAL FRAMING DETAILS 6/14/18 A5.1T TYPICAL THERMAL ENVELOPE DETAILS 6/14/18 A5.2 EXTERIOR WALL DETAILS 6/14/18 M0.1 MECHANICAL PLANS 6/14/18 EO.O ELECTRICAL NOTES 6/14/18 E0.1 ELECTRICAL PLANS 6/14/18 P0.1 DWVPLANS 6/14/18 P0.2 SUPPLY PLANS 6/14/18 P0.3 DWV & SUPPLY ISOMETRIC 6/14/18 S0.1 SITE BOX TO BOX AND BOX TO 6/14/18 FOUNDATION FASTENING CODE REFERENCES Buildings manufactured by VerMod LLC conform with editions of the following codes and there requirements. 1) Building Cocle: 9th 780 CMR 51.00: Massachusetts Residential Code 2015 IRC International Residential Code• 2) Mechanical Code: 91h 780 CMR 51.00: Massachusetts Residential Code 10.1.2 Site connections: between boxes and boxes to site hook-ups M & L BY BUILDER 1------------------------i 2009 IRC International Residential Code• This plan set and all contents herein are the exclusive property of 3) Plumbing Code: 248 CMR Uniform State Plumbing Code: Massachusetts 10.3 Double bowl Stainless Steel sink with combination spray/ faucet M & I BY BUILDER 10.4 Elongated bowl toilet (comfort height) M & l BY BUILDER 10.5 Heavyweight fiberglass 5' tub with faucet 11.0 HEATING, AIR CONDITIONING, AND YENTi\ ATION· M & L BYBUILDER 11.1 Conditioning Energy Recovery Ventilator (CERV) complete , heat/AC air source heat pump M & L BY BUii DER J 11.2 Soffits with ductwork roughed in per plan ' 11.2.1 Site connections: between boxes and boxes to site hook-upsM & I BYBUILDER 11.3 Water heater (heat pump) M & L. BY BUH DER 11.4 Continuous monitoring of carbon dioxide, pollutants, and humidity M & l BY BUil DER 11.5 Programmed continuios whole house heat recovery ventilation M & L BY BUii DER 11.6 All mechanicals installed M & L BYBIJ/l DER 11. 7 Condensate, Refrigerant and electric line for mini split M. &L BYBlfflDER 12.0 ELECTRICAL 12.1 200 Amp entrance panel 12.2 All material and labor to comply with the currant National Electric Code 12.3 Light almond color switches and outlets (cover plates provided, not installed) 12.4 Smoke, CO detectors [provided, not installed) 12.5 Energy Star light fixtures M. & L BY BUILDER 12.6 CAT 5 Phone and RG 6 TV in each bedroom and living area (3 locations) 12. 7 Secondary panel for solar and conduit to roof and below floor installed, ready for solar installation M & L BY BUILDER 12.8 Optional 7 KW solar array W/ integrated racking system (installed on site by Vermod) MJLJ....BY.-8UJLQEB. VERMOD LLC. No reproduction, copies and/or facsimiles shall be Residential Code produced in any manner whatsoever, whether in part or in whole. 2015 IRC International Residential Code• Coping of this plan set and/or its contents shall be cause for legal 4) Electrical Code: 9th 780 CMR 51.00: Massachusetts Residenlial Code action. 2015 IRC International Residential Code* ENERGY DATA BUILDING COMPONENT Floor* Wall Roof Windows ... Doors Conditioned Basement REQUIRED REQUIRED ACTUAL (ELECTRIC) (FOSSIL) # .05 .05 .033 .040 .40 .071.10 .08 .05 .033 .65 .40 .071.10 .025 .023 .017 .21 .12 .025 5) Energy Code: 9th 780 CMR 51.00: Massachusetts Residential Code 2015 IECC International Energy Conservation Code, 780 CMR 110 Appendix AN 6) Fuel Gas Code: 9th 780 CMR 51.00: Massachusetts Residential Code 2015 IRC International Residential Code• " with State Amendments and Supplements DESIGN LOADS !--------------------· ---~··---·- Roof Dead Load: 15 psf Floor Dead Load: 20 pst Habitable Attics & Sleeping Areas: 30 psf Live Load Seismic Category: B Stairs: 40 psf Live Load All other areas Except Balconies & Decks: 40 psf Live Load Foundation Bearing Capacity: 1500 psf. Table R401.4.1 IRC 2015 SNOW LOAD ( NORTHAMPTON MA ) Ground Snow Load: 40 psf Roof Snow Load: 35 psf 1-------------------------+-"':,now Exposure Factor: Ce 1.0 HEAT, AIR CONDITIONING AND VENTILATION Load Importance Factor: I 1.0 Thermal Factor: Ct 1.1 Plus Drifting as Applicable Hot Water Heater (hybrid heat pump) Material and labor by the builder. Splitter heat pump & AC combined with CERV complete Heat/ AC air source heat pump. Continuous monitoring of carbon monoxide, humidity, pollutants and whole house heat. Programmed continuous whole house heat recovery ventilation. Material and labor by the builder. Consealed duct work supplied and installed by VERMOD The Builder shall not make any penetrations through the Thermal Envelope of the modular boxes without approval from VerMod LLC * Floor above conditioned basement. *** Vinyl casements & awning windows: foam filled frames. triple glazed, argon filled. NO. DESCRIPTION BY DATE WIND LOAD Ultimate Design Wind Speed V ult: 117 mph Nominal Design Wind Speed V asd: 91 mph Risk Category: II Wind Exposure: C Basic Wind Design Pressure: 33 psf Internal Pressure Coefficient: +/. 0.18 Kevin M. Finn, P.E., Inc. 815 Waterbury Park Drive Elkhart, IN 46517 MA PE Lie. # 39636 PROJECT DESCRIPTION: I . e I 1-,,l ' · .. .· . ·, . . . · . . BOX PROFILE T 1---TYPICAL SINGLE BOX WITH ROOF 1----· SGALE:NA . . I . . i 1-€) I C ·_.-"j e.~·-· .. ·"-. ·-"-'~···."-·-···-"""'--'-'-'--•..,· I ' ','. ·._ :.· ··.' BOX PROFILE J k-=---TYPICAL SINGLE BOX FIRST FLOOR OR SCALE: NA ... SECOND FLOOR 0 EXTERIOR WALL @MARRIAGE WALL CLG CEILING OPN OPEN CEILING ~ FLOOR I ~ ROOF FRAMING SHEET TITLE: 2 BOXES Id \Ila .. I-__ · .. ,, . . INDICATES SITE WORK BUY THE BUILDER SEE JOB SPECIFIC PLANS FOR MORE DETAIL THIS IS A SAMPLING OF MODULAR BOX TYPES AND POSSIBLE COMBINATIONS OF THEM. SEE JOB SPECIFIC PLANS FOR ACTUAL ARRANGEMENTS. I 1 OF 18 I -Builder,The purchaser, who is the contractual purchaser of goods from VW will provide experienced professional contractors in responsible charge of the work to connect and complete modular components at site, including but not limited to building, mechanical, electrical, plumbing, and site work. The purchaser will be identified throughout this document as the "builder". All notes containing the term "by builder" are defining an obligation, for construction methodology I acceptable building practice for which VM accepts no responsibility, am:! should be reviewed carefully by the builder and the local building inspector. All such work and material shall be In compliance with applicable building codes. -- ·- ... ... ·-... . .. ... ••tafji~iff(i'. .: verm.o·a HABITAT FOR HUMANITY SHEET: CVR COVERSHEET -VM, For simplification, the manufacturer/supplier of the Third Party Inspected and Labeled modular compcnent known as VERMOD HIGH PERFORMANCE MANUFACTURED HOUSING, LLC will be id9ntified throuahout this document as the ''VM", or "VERMOD" 1 0 --... ORIGINAL PRINTING MJD -- 6/14118 P.O. B9x 566 2677 Route 5 Wilder VT. 05088 LOT 4, 133 GLENDALE RD. NORTHAMPTON MA 01062 18229 --.. ·-~----.. -----··-----, .. , ___ ,,. _______ ---~-""""··--·----·--- SOFFIT BEDROOM2 FLOOR ACCESS FOR SITE OOO 1 2 CONNECTION OF HVAC CVR DUCTS BOX A TO BOX B 00 FLOOR ACCESS FOR SITE CONNECTION OF KITCHEN VENT N SCALE: 3/16"=1 '-0" 1112" BOW VENT ~ '"""''''-Ll 1112" DRAIN~ SECOND FLOOR DWV PLAN LIVING / DINING KITCHEN BEDROOM1 e 1rn 10n erms -Builder.The purchaser, who is the contractual purchaser of goods from VW will provide experienced professional contractors in responsible charge of the work to connect and complete modular components at site, including but not limited to building, mechanical, electrical, plumbing, and site work. The purchaser will be identified throughout this document as the "builder". All notes containing the term "by builder" are defining ari obligation, for construction methodology/ acceptable building practice for which VM accepts no responsibility, and should be reviewed carefully by the builder and the local building inspector. All such work and material shall be in compliance with applicable building codes. -VM, For simplification, the manufacturer/supplier of the Third Party Inspected and Labeled modular component known as VERMOD HIGH PERFORMANCE MANUFACTURED HOUSING, LLC will be identified throu hout this document as the "VM", or "VERMOD" NO. DESCRIPTION BY DATE 0 ORIGINAL PRINTING MJD 6/14/18 D FIRST FLOOR DWV PLAN I I 1~liltfil;{': ..• ve>rmod P.O. Box 566 2677 Route 5 Wilder VT. 05088 PROJECT DESCRIPTION: HABITAT FOR HUMANITY LOT 4, 133 GLENDALE RD. NORTHAMPTON MA 01062 SHEET TITLE: 1ST AND 2ND FLOOR PLUMBING DWV PLANS I 15 OF 18 I SHEET: P0.1 18229 TUB/ F SHOWER A [r A F C C LAV ~' )~, 1!{" .. A_,,:,,,/ ~,, WC. //'A "~ ?5<f LA~~ WATER ,,> HEATER Cf A'~ ft WASHER ~ , RISERS IN BOX A BUILDER TO A~ 1 BOX , , CONNECT TO BOX B SUPPLY PIPING <A E WC ,A~ AB ~ "'A A'-:::--~ ALL MATERIAL AND LABOR TO COMPLETE SUPPLY PIPING IN CRAWL SPACE IS BY THE BUILDER PER APPLICABLE CODES ~~ " ALL H&C PIPING TO BE PEX WATER SUPPLY SYSTEM -------=COLDWATER SUPPLY -------= HOT WATER SUPPLY 3" MAIN ST ACK VENT & VENT THRU ROOF 21 DWVSYSTEM = DRAIN MATERIALS = VENT MATERIALS ':!.'l.,'f.. <?,.'f)'i (I-'] l)/ ~ 3" MAIN STACK VENT 57 i & VENT THRU ROOF I I 21~21 BOW VENT KITCHEN SINK DRAIN STUBBED TO BASEMENT (6~~)---· · -= RADON VENT MATERIALS 4-= SITE CONNECTION BETWEEN BOXES AND BOXES TO BASEMENT f DWV FITTING SCHEDULE PART# DESCRIPTION 1 1-1/2" 90° ELL 2 1-1/2" LS 90° ELL 3 1 • 1 /2" SANHEE 4 1-1/2" WYE W/ 1/B" BEND 5 1-1/2" DBL TEE 6 1-1/2"WYE 7 1·1/2" COUPLING 8 1-1/2" 1/8'' BEND g 1·1/2" P-TRAP WI CLEAN-OUT 10 TUB DRAIN & OVERFLOW 11 1-1/2" 45° ELL 21 2" 90° ELL 22 2' 90° LS ELL 23 2' SANI-TEE 24 2' WYE WI 118" BEND 25 2' DBL TEE 26 2'WYE 27 2'COUPLING 28 2' X 2" X 1-1/2" SANI-TEE 29 2' 1/8" BEND 30 2" P-TRAP WI CLEAN-OUT 31 LAUNDRY STAND PIPE (18"-36') 32 2' X 2" X 1-1/2" WYE 33 2' X 2" X 1-1/2" WYE WI 118" BEND 34 2' X 2" X 1-1/2" X 1-1/2" DBL TEE 35 2" X 1-112 COUPLING 36 CONTINUOUS WASTE 37 2'' X 1-112" X 2" SANI-TEE 38 2'' 45• ELL 41 3" 90° ELL 42 3'90° LS ELL 43 3"SAN-TEE 44 3" WYE WI 1/8' BEND 45 3"DBL TEE 46 3'WYE 47 COUPLING 48 3 X 3 X 2 SANI-TEE 49 3" X 3" X 1-112' SANI-TEE 50 3' 1/8" BEND 51 3" X 3" M/2" WYE 52 3" X 3" X 2'WYE 53 3' X 3" X 1-112" WYE WI 1/8'' BEND 54 3' X 3" X 2" WYE WI 118" BEND 55 3' X 3" X 2" X 2' DBL TEE 56 3" X 3" X 1-1/2' X 1-1/ 2" DBL TEE 57 3" X 2" COUPLING 58 3" 45° ELL 61 4' CLOSET FLANGE 62 4" X 3" CLOSET ELL 63 4'90° ELL 64 4' 90° LS ELL 65 4'WYE 66 4' SANI-TEE 67 4" WYE WI 1/8'' BEND 68 4' X 4" X3" SANI-TEE 69 4' X 4" X3" WYE 70 4' X 4" X3" WYE W/ 118" BEND 71 4" X 4" X 3" COUPLING 72 4" 45° ELL SUPPLY FITTINGS A = 1/2" PEX TUBING B = 3/4" PEX TUBING C = 1/2" COMP STOP D = 3/4" COMP STOP E = WASHER BOX F = ANTI-SCALD MIXING VALVE ~---·-------··-···-··----·---------------------------------! , MINIMUM DISTANCE FROM TABLE A I ' ~---M_!~~~U_M_DI_ST_'A_N_C_E~R_O_M_T_'A_B_~_E _A ___ ,i: , MINIMUM DISTANCE FROM TABLE • MINIMUM DISTANCE FROM TABLE A ,.. . I' ' NOTES D C GENERAL PLUMBING NOTES 1. ALL DRAIN, WASTE, & VENT LINES ARE SCHEDULE 40 PVC 9. ONE (MIN.) 3" MAIN STACK VENT PER DWELLING. 10. ONE (MIN.) 2" FUTURE VENT PER DWELLING (WHEN APPLICABLE). t ALL PLUMBING CONNECTIONS BETWEEN FLOORS ARE THE RESPONSIBILITY OF THE BUILDER -~ _w~ 8" J~ NO FIELD CUT HOLES IN HATCHED ZONES La 2XDa i Da ~-Lb 2XLb Job ~ .I ~ 2. ALL VENT STACKS SHALL EXTEND UNDIMINISHED IN SIZE TO A MINIMUM OF 1'·0" BELOW ROOF 11. HORIZONTAL TO HORIZONTAL AND VERTICAL TO HORIZONTAL DRAINS SHALL BE LONG SWEEP FITIINGS. 2. ALL PLUMBING CONNECTIONS, FIXTURES, ETC. IN THE BASEMENT IS I ARE THE RESPONSIBILITY OF THE BUILDER 3. PITCH ON HORIZONTAL WASTE LINES ARE 114" PER FOOT. 4. PLUMBING ACCESS PANELS SHALL BE PROVIDED PER APPLICABLE CODES. 5. TUB & SHOWER PROTECTION SHALL BE PROVIDED PER APPLICABLE CODES. 6. AIR ADMITTANCE VALVES ARE NOT PERMITTED IN THE STATE OF MASSACHUSETTS. 7. DRAINAGE LINES ARE STUBBED FIRST FLOOR MODULES FOR ON-SITE CONNECTIONS BY G.C. 8. ALL PLUMBING, PLUMBING FIXTURES, ETC. BELOW FIRST FLOOR (BASEMENT) IS I ARE SUPPLIED & INSTALLED BY G.O UNLESS OTHERWISE NOTED. Definition Of Terms 12. ALL WATER SUPPLY LINES ARE PEX TUBING. 13. DISHWASHER & CLOTHES WASHER ARE FACTORY SUPPLIED AND INSTALLED UNLESS OTHERWISE NOTED. 14. ANTI-SCALD DEVICES INSTALLED PER CODE. 15. WATER HAMMER ARRESTORS SHALL BE INSTALLED PER CODE. 16. INLET SHUT-OFF VALVE SHALL BE SUPPLIED & INSTALLED ON SITE BY G.C. 17. SILL COCKS ARE SUPPLIED & INSTALLED AT FACTORY EXCEPT IN AREAS BEYOND FACTORY LIMITS -Builder.The purchaser, who is the contractual purchaser of goods from VW will provide experienced professional contractors in responsible charge of the work to connect and complete modular components at site, including but not limited to building, mechanical, electrical, plumbing, and site work. The purchaser will be identified throughout this document as the "builder". All notes containing the term "by builder" are defining an obligation, for construction methodology I acceptable building practice for which VM accepts no responsibility, and should be reviewed carefully by the builder and the local building inspector. All such work and material shall be in compliance with applicable building codes. -VM, For simplification, the manufacturer/supplier of the Third Party Inspected and Labeled modular component known as VERMOD HIGH PERFORMANCE MANUFACTURED HOUSING, LLC will be identified throurihout this document as the "VM", or "VERMOD" NO. DESCRIPTION BY DATE 0 ORIGINAL PRINTING MJD 6/14/18 ~· ... 1.1 ,,.'... .. I rfiinimurif · ~-------------------·«- ROUND HOLE SIZE General Notes -HOLES MAY BE LOCATED VERTICALLY ANYWHERE WITHIN THE WEB. LEAVE 118" OF WEB (MINIMUM) AT TOP AND BOTIOM OF HOLE. -KNOCKOUTS ARE LOCATED IN WEB AT APPROXIMATELY 12" O.C.: THEY DO NOT AFFECT HOLE PLACEMENT. -FOR SIMPLE SPAN (5' MIN.) UN!FORML Y LOADED JOISTS MEETING THE REQUIREMENTS OF THIS GUIDE, ONE MAX. SIZE ROUND HOLE MAY BE LOCATED AT THE CENTER OF THE JOIST SPAN PROVIDED THAT NO OTHER HOLES OCCUR IN THE JOIST. -DISTANCES ARE BASED ON THE MAX. UNIFORM LOADS SHOWN IN TRUS JOIST T JI JOIST SPECIFIER'S GUIDE T J-4000 -DO NOT CUT OR NOTCH FLANGE. PROJECT DESCRIPTION: :: •i• i . ~,• : NO FIELD CUT HOLES 8" 1m nrmum IN HATCHED ZONES ---·--··--------------~ SQUARE OR RECTANGULAR HOLE SIZE DEPTH T JI 2" i 3" 4" 5" 6 1/2" g 112" 2so 1 '-o" I 21~0" ~3, ... on 4,::5,, s· -o··- How to use the Table 1. USING THE TABLE ABOVE, DETERMINE THE HOLE SHAPE/SIZE 2. SCAN HORIZONTALLY UNTIL YOU INTERSECT THE CORRECT HOLE SIZE COLUMN. 3. MEASUREMENT SHOWN IS THE MINIMUM DISTANCE FROM EDGE OF HOLE TO SUPPORT. 4. MAINTAIN THE REQUIRED MINIMUM DISTANCE FROM THE END SUPPORT. ALLOWABLE HOLES IN 9 1/2" 230 T JI FLOOR JOIST SHEET TITLE: ·····1·1~fij.t1!\1.:'\)·, ·vermdd HABITAT FOR HUMANITY PLUMBING ISO DWV AND SUPPLY P.O. Box 566 2677 Route 5 Wilder VT. 05088 LOT 4, 133 GLENDALE RD. NORTHAMPTON MA 01062 I 17 OF 18 j SHEET: P0.3 18229 e 1rn 10n erms BEDROOM1 THRUWALL~ DROPS TO 1 ST FLOOR -Builder.The purchaser, who is the contractual purchaser of goods from VW will provide experienced professional contractors in responsible charge of the work lo connect and complete modular components at site, including but not limited to building, mechanical, electrical, plumbing, and site work. The purchaser will be identified throughout this document as the "builder". All notes containing the term "by builder" are defining an obligation, for construction methodology I acceptable building practice for which VM accepts no responsibility, and should be reviewed carefully by the builder and the local building inspector. All such work and material shall be in compliance with applicable building codes. -VM, For simplification, the manufacturer/supplier of the Third Party Inspected and Labeled modular component known as VERMOD HIGH PERFORMANCE MANUFACTURED HOUSING, LLC will be identified throu hout this document as the "VM", or "VERMOD" THRU FLOOR KITCHEN NO. DESCRIPTION BY DATE 0 ORIGINAL PRINTING MJD 6114118 N SECOND FLOOR WATER SUPPLY PLAN SCALE: 3/16"=1'·0" FIRST FLOOR WATER SUPPLY PLAN --~~~1f~f v•errm oa P.O. B~x 566 2677 Route 5 Wilder VT. 05088 PROJECT DESCRIPTION: HABITAT FOR HUMANITY LOT 4, 133 GLENDALE RD. NORTHAMPTON MA 01062 SHEET TITLE: 1ST AND 2ND FLOOR PLUMBING SUPPLY PLANS -~~----------------------------------------------------------------------------------~ j 16 OF 18 j SHEET: P0.2 18229