Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
69 Chestnut Ave. Ext. HERS
BldgSummary 69 Chestnut Ave Ext.pdf Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Property/Builder Information Building Name 69 Chestnut Ave Ext Owner's Name W Marek Inc. Property Address 69 Chestnut Ave Ext City, St, Zip Leeds, MA 01053 Phone Number 413-977-9539 Builder's Name W Marek Inc. Phone Number 413-977-9539 Email Address wmarek3@comcast.net Plan/Model Name Community/Development Permit Date/Number Organization Information Organization Name New England Energy Raters, LLC Address 198 Sylvester Rd. City, St, Zip Florence , MA 01062 Phone Number 413-570-5750 Website neenergyraters.com Rating/RESNET Information Provider ID 1998-072 Sample Set ID 00000000 Registry ID Registry Date Registered Rater's Name Mark Bashista Rater's ID 7580975 Rater's Email neenergyraters@outlook.com Last Field Insp 7/6/18 Rating Type Projected Rating Reason for Rating New Home Rating Number Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 2 of 13 General Building Information Area of Conditioned. Space(sq ft) 3608 Volume of Conditioned. Space 32628 Year Built 2018 Housing Type Single-family detached Level Type(Apartments Only) None Floors on or Above-Grade 2 Number of Bedrooms 4 Foundation Type Conditioned basement Enclosed Crawl Space Type N/A Number of Stories Including Conditioned Basement 3 Thermal Boundary Location N/A Foundation Wall Information Name Library Entry Location Length(ft) Total Height(ft) Depth Below Grade(ft) Height Above Grade(ft) Uo Value Combo* Uo Value (wall only) Foundation R-10 Interior******** Cond->ambient/grnd 126.0 7.8 5.8 2.0 0.065 0.094 Foundation garage R-10 Interior******** Cond->garage/grnd 24.0 7.8 5.8 2.0 0.066 0.094 * Uo Value Combo combines wall, airfilm, and soil path Foundation Wall Library List Foundation Wall: R-10 Interior******** Type Solid concrete or stone Thickness(in) 8.0 Studs None Interior Insulation Continuous R-Value 10.0 Frame Cavity R-Value 0.0 Cavity Insulation Grade 1 Ins top 0.0 ft from top of wall Ins Bottom 0.0 ft from bottom of wall Exterior Insulation Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 3 of 13 Foundation Wall Library List R-Value 0.0 Ins top 0.0 ft from top of wall Ins bottom 0.0 ft below grade Note Slab Floor Information Name Library Entry Area(sq ft) Depth Below Grade(ft) Full Perimeter(ft) Exposed Perimeter(ft) On-Grade Perimeter(ft) Slab Uninsulated2*0** 1280 5.8 150 150 0 Slab Floor Library List Slab Floor: Uninsulated2*0** Slab Covering Carpet Perimeter Insulation (R-Value) 0.0 Perimeter Insulation Depth (ft) 0.0 Under-Slab Insulation (R-Value) 0.0 Under-Slab Insulation Width (ft) 0.0 Slab Insulation Grade 1 Radiant Slab No Note Rim and Band Joist Information Name Location Area(sq ft) Continuous Ins Framed Cavity Ins Cavity Ins Thk(in) Joist Spacing Insulation Grade Uo Value Basement amb Cond -> ambient 126.00 0.0 20.0 3.0 16.0 1 0.057 Bsmt garage Cond -> garage 24.00 0.0 20.0 3.0 16.0 1 0.057 1st-2nd Amb Cond -> ambient 56.00 0.0 20.0 3.0 16.0 1 0.057 1st-2nd Attic Cond -> attic 87.00 0.0 20.0 5.5 16.0 1 0.049 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value 1st amb R-20, 2x6 16" o.c. Cond -> ambient Medium 1060.00 0.060 Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 4 of 13 Above-Grade Wall Name Library Entry Location Exterior Color Area(sq ft) Uo Value 1st amb 2x4 R-13 (2x4)* Cond -> ambient Medium 27.00 0.085 1st garage R-20, 2x6 16" o.c. Cond -> garage Medium 216.00 0.060 2nd amb R-20, 2x6 16" o.c. Cond -> ambient Medium 732.00 0.060 2nd attic/porch rf R-20, 2x6 16" o.c. Cond -> attic Medium 266.00 0.060 Above-Grade Wall Library List Above-Grade Wall: R-20, 2x6 16" o.c. Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 20.0 Frame Cavity Insulation Thickness (in) 5.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 5.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note Above-Grade Wall: R-13 (2x4)* Information From Quick Fill Screen Wall Construction Type Standard Wood Frame Continuous Insulation (R-Value) 0.0 Frame Cavity Insulation (R-Value) 13.0 Frame Cavity Insulation Thickness (in) 3.5 Frame Cavity Insulation Grade 1 Stud Size (w x d, in) 1.5 x 3.5 Stud Spacing (in o.c.) 16.0 Framing Factor - (default) 0.2300 Gypsum Thickness (in) 0.5 Note Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 5 of 13 Window Information Overhang Interior Adjacent Name Wall Assignment Orient U-Value SHGC Area (sqft) Depth (ft) To Top (ft) To Btm (ft) Winter Shading Summer Shading Winter Shading Summer Shading Bsmt rear FndWall 1 North 0.280 0.250 12.00 0.0 0.0 0.0 0.85 0.70 None None Bsmt right FndWall 1 East 0.280 0.250 8.00 0.0 0.0 0.0 0.85 0.70 None None 1st Front OH AGWall 1 South 0.280 0.250 41.34 7.0 1.0 6.0 0.85 0.70 None None 1st Right AGWall 1 East 0.280 0.250 41.34 0.0 0.0 0.0 0.85 0.70 None None 1st rear AGWall 1 North 0.280 0.250 85.21 0.0 0.0 0.0 0.85 0.70 None None 2nd front AGWall 4 South 0.280 0.250 48.00 0.0 0.0 0.0 0.85 0.70 None None 2nd Right AGWall 4 East 0.280 0.250 24.00 0.0 0.0 0.0 0.85 0.70 None None 2nd rear AGWall 4 North 0.280 0.250 56.94 0.0 0.0 0.0 0.85 0.70 None None Door Information Name Library Entry Wall Assignment Opaque Area(sq ft) Uo Value R-Value of Opaque Area Storm Door Front Fiberglass AGWall 1 20.0 0.126 7.0 No Garage Steel-polyurethane AGWall 2 20.0 0.283 2.6 No Roof Information Name Library Entry Ceiling Area(sq ft) Roof Area(sq ft) Exterior Color Radiant Barrier Type Uo Value Cement or Clay Tiles Roof Tile Ventilation 2nd Flat R-49 Blown, Attic*** 969.00 1211.25 Medium No Attic 0.020 No No 1st Ceiling R-38 Blown, Attic** 48.00 60.00 Medium No Attic 0.026 No No Sloped R-38, Vaulted 16oc*** 270.00 270.00 Medium No Vaulted 0.031 No No Roof Library List Ceiling: R-49 Blown, Attic*** Information From Quick Fill Screen Continous Insulation (R-Value) 36.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 6 of 13 Roof Library List Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note Ceiling: R-38 Blown, Attic** Information From Quick Fill Screen Continous Insulation (R-Value) 25.0 Cavity Insulation (R-Value) 13.0 Cavity Insulation Thickness (in) 3.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 3.5 Insulated Framing Spacing (in o.c.) 24.0 Framing Factor - (default) 0.1100 Ceiling Type Attic Note Ceiling: R-38, Vaulted 16oc*** Information From Quick Fill Screen Continous Insulation (R-Value) 0.0 Cavity Insulation (R-Value) 38.0 Cavity Insulation Thickness (in) 9.5 Cavity Insulation Grade 1 Gypsum Thickness (in) 0.500 Insulated Framing Size(w x h, in) 1.5 x 9.5 Insulated Framing Spacing (in o.c.) 16.0 Framing Factor - (default) 0.1412 Ceiling Type Vaulted Note Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 7 of 13 Mechanical Equipment Number of Mechanical Systems 3 Heating SetPoint(F) 68.0 Heating Setback Thermostat Present Cooling SetPoint(F) 78.0 Cooling Setup Thermostat Present DHW SetPoint(F) 125.0 DHW: 50 Gal Hybrid EF3.53 Water Heater Type Heat pump Fuel Type Electric Energy Factor 3.53 Recovery Efficiency 0.00 Water Tank Size (gallons) 50 Extra Tank Insulation (R-Value) 0.0 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Heat: 95AFUE Gas Furn 54k SystemType Fuel-fired air distribution Fuel Type Natural gas Rated Output Capacity (kBtuh) 54.0 Seasonal Equipment Efficiency 95.0 AFUE Auxiliary Electric 442 Eae Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 Cool: 14 SEER A/C 28.8k Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 8 of 13 Mechanical Equipment System Type Air conditioner Fuel Type Electric Rated Output Capacity (kBtuh) 28.8 Seasonal Equipment Efficiency 14.0 SEER Sensible Heat Fraction (SHF) 0.70 Note Number Of Units 1 Location Conditioned area Performance Adjustment 100 Percent Load Served 100 DHW Efficiencies All bath faucets & showers <= 2gpm false All DHW pipes fully insulated >= R-3 false Recirculation type None (standard system) Farthest fixture to DHW heater 30 TOTAL Pipelength for longest DHW run 60 DWHR unit present? false DHW Diagnostics dhwGpd 52.83 peRatio 0.60 dishwasherGpd 5.10 clothesWasherHotWaterGPD -0.09 EDeff 0.94 ewaste 22.49 tmains 55.40 dwhrWhInletTempAdj 0.00 pumpConsKwh 0.00 pumpConsMmbtu 0.00 Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 9 of 13 Duct Systems Name Whole house Conditioned Floor Area(sq ft) 3608.0 # of Returns 4 Heating System 95AFUE Gas Furn 54k Cooling System 14 SEER A/C 28.8k Supply Duct Surface Area(sq ft) 730.6 Return Duct Surface Area(sq ft) 541.2 Duct Leakage Qualitative Assessment Not Applicable Duct Leakage to Outside Supply+Return 0.030 CFM25 / CFA Supply Only Not Applicable Return Only Not Applicable Total Duct Leakage 0.040 CFM25 / CFA Duct Tightness Test Postconstruction Test Test Exemptions IECC FALSE RESNET LtO FALSE ENERGY STAR LtO FALSE Type Location Percent Location R-Value Supply Conditioned basement 65.0 0.0 Attic, exposed 35.0 8.0 Return Conditioned basement 65.0 0.0 Attic, exposed 35.0 8.0 Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 10 of 13 Infiltration and Mechanical Ventilation Whole Dwelling Infiltration Input Type Blower door Heating Season Infiltration Value 3.00 ACH @ 50 Pascals Cooling Season Infiltration Value 3.00 ACH @ 50 Pascals Shelter Class 4 Code Verification Tested Mechanical Ventilation for IAQ Type Exhaust Only Rate(cfm) 74 Sensible Recovery Efficiency(%) 0.00 Total Recovery Efficiency(%) 0.00 Hours per Day 24.0 Fan Power (watts) 13.20 ECM Fan Motor false Ventilation Strategy for Cooling Cooling Season Ventilation Natural Ventilation Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 11 of 13 Lights and Appliances Rating/RESNET audit Ceiling Fan CFM / Watt 0.00 Refrigerator kWh/yr 709 Refrigerator Location Conditioned Range/Oven Fuel Type Natural gas Induction Range No Convection Oven No Dishwasher Energy Factor 0.46 Dishwasher kWh/yr 0 Place Setting Capacity 12 Clothes Dryer Fuel Type Electric Location Conditioned Moisture Sensing No CEF 2.62 Clothes Washer Location Conditioned LER (kWh/yr) 96 IMEF 3.060 Capacity (CU.Ft) 3.810 Electricity Rate 0.11 Gas Rate 1.22 Annual Gas Cost 11.00 Qualifying Light Fixtures Interior CFLs % 100.0 Interior Fluorescent % 0.0 Exterior Lights % 100.0 Garage Lights % 100.0 Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 12 of 13 Mandatory Requirements IECC Requirements Verified IECC 04 false Verified IECC 06 false Verified IECC 09 true Verified IECC 12 true Verified IECC 15 true Verified IECC 18 false Verified NY-ECCC 2016 false Verified IECC MI false EPA Requirements Rater certifies that the home complies with the following requirements for: None Rater Design Review Checklist(National) Rater Field Checklist(National) HVAC Design Report HVAC Commissioning Checklist (optional) ENERGY STAR Version 3 Appliances Amount Refrigerators 0 Ceiling Fans 0 Exhaust Fans 0 Dishwashers 0 ENERGY STAR Version 3 Basements Basement Wall Area 50% Below Grad: false Basement Floor Area 0.00 2009 IECC Prescriptive Requirements for ENERGY STAR v3.0 false Slab Insulation Exemption: false Indoor airPlus Verification Checklist false EPA Field App ID Building Summary Property W Marek Inc. 69 Chestnut Ave Ext Leeds, MA 01053 Weather:Chicopee, MA 69 Chestnut Ave Ext REM 1561 Marek 69 Chestnut Ext.blg Organization New England Energy Raters, LLC 413-570-5750 Mark Bashista Builder W Marek Inc. REM/Rate - Residential Energy Analysis and Rating Software v15.6.1 This information does not constitute any warranty of energy costs or savings. © 1985-2018 NORESCO, Boulder, Colorado. HERS Projected Rating 7/6/18 Rater ID:7580975 Page 13 of 13 DOE Zero Energy Ready Home Home Builder ID Number Mandatory Requirements Verified Fenestration false Verified Insulation false Verified Duct Location false Verified Appliance false Verified Lighting false Verified Fan Efficiency false Verified Water Efficiency false Verified EPA Indoor airPLUS false Verified Renewable Energy Ready Solar Electric false Optional Home Builder Commitments for Recognition Certified under the EPA WaterSense for New Homes Program No Certified under the IBHS fortified for Safer Living Program No Followed the DOE Zero Energy Ready Home Quality Management Guidelines No The buyer of this home signed a waiver giving DOE Zero Energy Ready Home access to utility bill data for one year. No Active Solar System Type None Collector Loop Type None Collector Type None Collector Orientation None Area(sq ft) 0.0 Tilt(degrees) 0.0 Volume(cu ft/gal) 0.0 Notes No slab insulation Prelim HERS Marek 69 Chestnut Ave Ext.pdf