Loading...
NAE-2018-02315 Permit.pdf• Regulatory Division File Number: NAE-2018-02315 DEPARTMENT OF THE ARMY US ARMY CORPS OF ENGINEERS NEW ENGLAND DISTRICT 696 VIRGINIA ROAD CONCORD MA 01742-2751 November 14, 2018 City of Northampton Department of Public Works Attention: David K. Veleta 125 Locust Street Northampton, Massachusetts 01060 Dear Mr. Veleta: We have reviewed your application to permanently discharge 748 square feet of fill below the Ordinary High Water (OHW) mark of waters of the United States associated .with slip-lining and related work at three culverts conveying Burts Pit Road over two unnamed tributaries to Parsons Brook in Northampton, Massachusetts.· The ·first stream crossing conveys a perennial stream and involves the lining of the existing 48'' CMP (corrugated metal pipe) with a 42'' circular HDPE (high-density polyethylene) pipe. A beveled inlet will be installed to improve hydraulic efficiency. The second stream crossing conveys an intermittent stream and involves the lining of twin 29'' by 41 '' ovalized CMP pipes with 22.5 '' by 36'' ovalized HDPE pipes. A new concrete headwall will be installed at the inlet. The new pipes will be installed off-center such that the inverts of the culverts are approximately 1" vertical above the existing invert elevations. Natural rock ramps are proposed at the outlets to facilitate upstream movements of aquatic species. The project also includes 3,399 square feet of temporary impacts below OHW and within vegetated wetlands associated with construction access and dewatering behind control of water structures. The work is shown on the enclosed plans entitled ''CONTRACTS 2018 BURTS PIT ROAD PAVING AND ROADWAY IMPROVEMENTS U SACE PCN'', on two sheets (labeled P-1 and P-2) with revision dates of ''10/17 /2018 '', and ''CONTRACTS 2018 BURTS PIT ROAD CULVERT RELINING PROJECT'' on two sheets (labeled D-1 and D-2) dated ''09 /05 /2018'' (sheet D-1 revised ''10/17./2018''). Based on the information you have provided, we have determined that the proposed actiyity, which includes work and/or a discharge of dredged or fill material into waters of the United · States, including wetlands, will have only minimal individual or cumulative .environmental impacts. Therefore, this work is authorized under the enclosed April 2018 Massachusetts General Permits (MA GPs ), specifically GP 10 , under the pre-construction notification process. This work must be performed in accordance with the terms and conditions of the GPs. You are responsible for complying with all of the G:Ps ' requirements. Please review the enclosed GPs carefully, in particular the general conditions beginning on Page 19 , to be sure tp.at you understand its requirements. You should ensure that whoever does the work fully understands the requirements and that a copy of the GPs and this authorization letter are at the project site throughout the time the work is underway. 2 This authorization requires you to complete and return the enclosed Work Start Notification Form to this office at least two weeks before the anticipated starting date . You must also complete and return the enclosed Compliance Certification Form within one month following the completion of the authorized work. This permit does not obviate the need to obtain other Federal, State, or local authorizations required by law. Performing work not specifically authorized by this determination or failing to comply with all of the terms and conditions of the GPs may subject you to the enforcement provisions of our regulations. This authorization presumes that the work as described above and as shown on your plans noted above is in waters of the U.S . Please submit a request for an approved jurisdictional determination to this office in writing if you desire to appeal our jurisdiction. This authorization expires. on April 5, 2023, unless it is modified, suspended, or revoked before then. You must commence or have under contract to commence the work authorized herein by April 5, 2023 and complete the work by April 5, 2024. If not, you must contact this office to determine the need for further authorization before beginning or continuing the activity. We recommend that you contact us before this authorization expires to discuss a time extension or permit reissuance. Please contact us immediately to discuss modification of this authorization if you change the plans or construction methods for work within our jurisdiction. This ·office must approve any changes before you undertake them. We continually strive to improve our customer service. In order for us to better serve you, we would appreciate your completil).g our Customer Service Survey located at http://corpsmapu.usace.army.mil/ cm apex/f?p=regulatory survey. Please contact Dan Vasconcelos, of my staff, at (978) 318-8653 if you have any questions . Sincerely, Barbara H. Newman Chief, Permits and Enforcement Branch • Regulatory Division Enclosures • 3 cc: Ed Reiner, U.S. EPA, Region 1, Boston, Massachusetts, reiner.ed@ epa.gov David Cameron, DEP WERO, Wetlands and Waterways, Springfield, Massachusetts; davi d.cameron@ state.ma. us. u.s Michael Girvan, MassDEP-WRP, Boston, Massachusetts; michael.girvan@ state.ma.us Conservation Commission, Northampton, Massachusetts, SLa Valley@ northamptonma.gov Johanna Stacy, Department of Public Works, Northampton, Massachusetts, j stacy@ northamptonma.gov US Army Corps of Engineers® New England District WORK-START NOTIFICATION FORM (Minimum Notice: Two weeks before work begins) ****************************************************************************** * * * * * * * EMAIL TO: cenae-r@usace.army.mil ; or MAIL TO: U.S. Army Corps of Engineers, New England District Permits and Enforcement Branch Regulatory Division 696 Virginia Road Concord, Massachusetts 01742-2751 * * * * * * * ****************************************************************************** Corps of Engineers Permit No. NAE-2018-02315 was issued to the City of Northampton and authorized the permanent discharge of748 square feet of fill below the Ordinary High Water (OHW) mark of waters of the United States associated ~ith slip-lining and related work at three culverts conveying Burts Pit Road over two unnamed tributaries to Parsons Brook in Northampton, Massachusetts. The frrst stream crossing conveys a perennial stream and involves the lining of the existing 48 '' CMP (corrugated metal pipe) with a 42'' circular HDPE (high-density polyethylene) pipe. A beveled inlet will be installed to improve hydraulic efficiency. The second stream crossing conveys an intermittent stream and involves the lining of twin 29 '' by 41 '' ovalized CMP pipes with 22.5'' by 36'' ovalized HDPE pipes. A new concrete headwall will be installed at the inlet. The new pipes will be installed off- center such that the inverts of the culverts are approximately l" vertical above the existing invert elevations. Natural rock ramps are proposed at the outlets to facilitate upstream movements of aquatic species. The project also includes 3,399·square feet of temporary impacts below OHW and within vegetated wetlands associated with construction access and dewatering behind control of water structures. The people (e.g., contractor) listed below will do the work, and they understand the permit's conditions and limitations. PLEASE PRINT OR TYPE Name of Person/Firm: ------------------------------ Business Address: Telephone Numbers: Finish: ----------Proposed Work Dates: Start: --------- Permittee/Agent Signature: Date: ________ _ Printed Name: Title: ---------- Date Permit Issued:~-------~· Date Permit Expires: _________ _ ****************************************************************************** FOR USE BY THE CORPS OF ENGINEERS PM: Vasconcelos Submittals Required: Inspection Recommendation: -------------------------~ US Army Corps of .Engineers ® New England District COMPLIANCE CERTIFICATION FORM (Minimum Notice: Permittee must sign and return notification within one month of the completion of work.) Permit Number: NAE-2018-02315 Project Manager: Vasconcelos Name of Permittee: City of Northampton Permit Issuance Date: November 14, 2018 Please sign this certification and return it to our office upon completion of the activity and any mitigation required by the permit. You must submit this after the mitigation is complete, but not the mitigation monitoring, which requires separate submittals. ************************************************************************ * * E-MAIL TO: cenae-r@usace.army.mil; or * * MAIL TO: * * * * Permits and Enforcement Branch A U.S. Army Corps of Engineers, New England District Regulatory Division 696 Virginia Road Concord, Massachusetts 01742-2751 * * * * * * * ************************************************************************ * Please note that your permitted activity is subject to a compliance inspection by an U.S. Army Corps of Engineers representative. If you fail to comply with this permit you are subject to permit suspension, modification, or revocation. I hereby certify that the work authorized by the above referenced permit was completed in accordance with the terms and conditions of the above referenced permit, and any required mitigation was completed in accordance with the permit conditions. Signature of Permittee Date Printed Name Date of Work Completion Telephone Number Telephone Number '