35-050 (9) 966 RYAN RD BP-2019-0485 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:35-050 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2019-0485 Proiect# JS-2019-000782 Est.Cost: $19489.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: NORTHEAST SOLAR DESIGN ASSOCIATES LLC 106113 Lot Size(sa.ft.): 14897.52 Owner: JONES MICHAEL E&MEGAN E zonina: Applicant: NORTHEAST SOLAR DESIGN ASSOCIATES LLC AT. 966 RYAN RD Applicant Address: Phone: Insurance: 136 ELM ST (413) 247-6045 () Liability HATFIELDMA01038 ISSUED ON:10/19/2018 0:00:00 TO PERFORM THE FOLLOWING WORK.-INSTALL 16 ROOF TOP SOLAR PANELS -5.76 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeType: Date Paid: Amount: Building 10/19/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner aN C's , o Ic fCI ! = �Ingapnt i 212 Main Street OCT 18 2013 Room 100 N Qrthamptorn IIA 01060 phong 41587-1240 Fax 413-587-1272 rUILDING INSPECTIONS 10001,+8N,MAIDIe66 I APPLICATION TO CONSTRUCT,ALTER,REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 .SWE MFORkt ATX)N 6 to, /-/ J '7 85- 1.1 PraoertY Address: This section to be eonlplab by oAioe 966 Ryan Rd Yap 26—w 06-0 Llrq Florence MA 01062 IIons 0vwinyDb11rW Sm 9L DW&Wt Ce 012t7ld SECTION 2.PROPERTY OViNERSHUqAlffHORIZED AGENT V Owner at Racard: 966 Ryan Rd Michael Jones Florence MA 01062 Saw*(Pnnt) Currom Maung Address: 1 413-727-8669 ieteDhor`� Sigr%vu e Nortt S I r 136 Elm St. Hatfield, MA 01038 N, awR(Pnnti Gwent Maung Address: Al. 413-247-6045 Sign�lure TelepMre ciw Item Esiimeted Cost(DAM)to be 01111c iai U13e Only Gaff0eted t applicant 1. Building (a)Building Permit Fee 2. Electrical CA Eallmated Tates Cast of Canstrudkan horn 3. Plumbing BultdinS Psmilt Fee 4. Mechanical(HVAC) 5.Fire PmtecGon 6. Tccel = t +2+3*4+S 119,489 C m*Numbw 'y.3 Thb Ss cbm For OAleid tlss On Offile Building Pemlit Number Issued: 101i i3ul p vdInwealarofBu***. came Section 4. ZONING Ala Infomlatlon Must be Computed, Permit Can be Denied clue To Incomplete lntormation Existing Propo9od Rcgrdred by Zoning Tbia aoktm to be SIM in h7 Building[kpa=mt Lot Sim Frontage Setbacks Front Silk L'I R: L_'_ R: Rear BmIding Height € SFootage __ ___ �, � 1 Open Space Footage ..._.____-� -..____ % (tall VU Winut bit&toYod #of Pwidng Spam �_.. Fill: I vohuw&Locabm) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO DONT KNOW YES 0 IF YES, slate issued:; IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW 0 YES IF YES: enter Book M1 Page andlor Document t S. Dees the site contain a brook, body of wager or wettands? NO DONT KNow 0 YES 0 IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained 0 Obtained 0 , Date Issued: C. Do any signs exist on the property? YES 0 NO IF YES, describe size, type and location: D. Are there any proposed changes to or additions of sighs intended for the property? YES 0 No IF YES, describe size, type and location. E YVIII the construction aciMty dstwb(c6priinlL gradlin%jiWasystion.or filling)aver 1 acre aria it pert cis oamman plan OW vAN dhMA over t acre? YES 0NO IF YES.than a Northampton Storm Water Management Permit Iran the DPW Is required_ SECTION S. RIPTION OF PROPOSED .41 New Hausa E:] Addition © Repiacement Windows Alteration(s) 0 Roofing 0 Or Doom E3 Accessory Bldg. ❑ Demolition ❑ New Signs (0) Delos IU Siding IOI Other(,q Brief DemAption of Proposed Install 16 solar panels on Roof Work: Alteration of existing badroorn Yes No Adding new bedroom Yes NO Attached Narrative Renoveting unfinished basement Yes _No Plians Attached Roll -Sheet a. Use of building:one Femity Two Fancy Other b. Number of rooms in each farrily unit: Number of Bathroorns c, Is there a garage attached? d. Proposed Square footage of new construction_ Dimensions e. Number of stories? f. Method of heating? Fireplaces or Wcodstoves Number of each g. Energy Consrervabovn Co Masschieck Energy Compliance farm attached? h. Type of oonstrumon L Is construction within 100 ft.of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No I. Depth of basement or cedar fbor bellow finished grade k. Wilt building conform to the Building and Zoning regulations? Yes No. 1. Septic Tank City Surer Private well City water Supply SECTION Ts-OWNER AUTHORIZATION.TO BE COMPLETED VAIIEN OWNERS AGENT OR CONTRACTOR APPLES FOR BWLDM PERMIT I Michael Jones as owner of the sub(ect property hereby authorize Northeast Solar to act on my behalf,in all majiers authorized by this building perp it application. sionours of Ow ner Dale 1, Gregory Garrison/Northeast Solar as OwnerYAuthorized Agent hereby declare that the statements and Wormation on the foregoing application are true and acowats,to the best of my knowledge and belief. Signed under the pains and penal6as of perjury. GreciorAGarrisoOM, Print Mrr* signerre of t]aAe SECTION d-CONSTIFAJCT10N SERVICES ::1 8.1 UceanMW CongIMCdon SuRtryl Not Applicable ❑ Phillip Baunsgard 05106113 t.ioaras Number 41 Heath Rd Colrain, M$ 01340 6/7/19 P�tld E*taUon Dasa P 413-247-6045 MOM Not Applicable ❑ Northeast Solar 169641 Comp=Name Registration Number 136 Elm 4 A Ha5tq4,1dAjMa 01038 7/13/2019 Address A&�-�SAJ# . - Expiration Orate Telephone 413-247-6045 SECTION 10-WMIR RENSATION INSURANCE AFFMAViT(ILG.1..e`152,J 35C(6)) Workers Compensation Insurance affidavit must be competed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of&*building permit. Signed Affidavit Attached Yee.......M No...... ❑ The current exemption for"homeowners"was extended to include Owner-awmied Dwe[lin¢s of one(1) or two(2)53milics and to allow such horneowner to engage an individual for hire who docs not possess a&-cnse,nravided that the amasr arta m sanerviw.CNIR 90, Sixth Edition Section t11UL t. Pcmw(9)who own a parcel of land on which bvsbe resides or intends to reside,on which there is,or is intended to be,a one or two fatuity dwelling,attached or dctaclmd structures accessory to such use aD&or farm structures.A person veto constructs more thin one bmw in a two-year period shall no be considered a bomemmer. Such"bomcownce shall submit to the Building Ot'iieial,on a form acceptable to the Building OfHcia4 thm he><Ae a all be ro�.■±�ea[ble for such work performed ander the bnffdLm2 nermK. As acting Cons&nctign Sopervisor your presence cm the job site will be rcquired from time to time,during and upon compketion of the work for which this permit is iced. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Fimptoyers to Emplo)c+es for injuries not resulting in Death)of the Massachusetts General Laws Annotated,You may be liable for person(s) you hire to perform work for you under this permit. Tbc undcraigned"bomcownca"certifies and asannes,resporm-bility for compliance with the State Building CD&,City of Northampton Ordinanem State and Local Zoning,Lain and State of Massachusctu General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: o(o a The debris will be transported by: -CAW A t i U II AM at8k9 The debris will be received by: ill'licoozker -,(n6J buyntA T rj Building permit number: Name of Permit Applicant : I U W-2A,4 7 ho i _t '40A c"Dte nature of Permit App&Ant The Commonwealth of Massachusetts Department of Industrial Accidents Office of Investigations 1 Congress Street, Suite 100 Boston,MA 02114-2017 'U'r www.nmus.gov/d`ia Workers' Compensation Insurance Affidavit: General Businesses Applicant Information Please Print L egibl_y Business/Organization Name:Northeast Solar Address:136 Elm St. City/State/Zip:Hatfield,Ma 01038 Phone#:413-247-6045 Are you an employer?Check the app rip riate box: Business Typ a(required): 1.[Z] I am a employer with 17 employees(full and/ 5. ❑Retail or p art-time).* 6. ❑RestaurantrB u/E ating E stablishm ent 2.❑ I am a sole proprietor or partnership and have no q ❑O ffica and/or Sales(incl.real estate, auto, etc.) empl oye e s w orking for m e in any c ap acity. [No workers' comp.insurance required] g• [:]Non-profit 3.❑ We are a corporation and its officers have exercised 9. ❑Entertainment their right of exemptionper c. 152,§1(4), and we have 10.❑Manufacturing no employees.[No workers'comp.insurance required]* 4.[] We are anon-profitorganiaation, staffed by volunteers, 11.❑Healthcare with no employees.[No workers' camp. insurance req.] 1 12.0 Other *Any applicant that checks box#1 mut also fill out the sectionbelow showirg their workers'compensation policy irf'amation **If the corporate avers have exempted themselves,but the corporation has other employees,aworlmrs'compensation policy is required and such an organimtianshould check box#1. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy information. Insurance CampanyName: ACE American Insurance Co Insurer's Address: 966 Ryan Rd City/State/zip: Florence MA 01062 Policy# or S elf-ins.Lic. # 1K445604UB Expiration Date 7/8/19 Attach a copy of the workers'comp ensationp orwy declaration page(showing the p olicy numb er and exp iration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of aSTOP WORK ORDER and afine of up to$250.00 a day against the violator. B e advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby cert:;fy, r Ae ins and fperjunry Aid the reformation provided above is trete and correct. S ionature: Date: 8/30/2018 Phone#:4134- 47-6045 Offlcial use only. Do mot write in Ms area,to be completed by city or town official City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Budding Department 3.City/Town Clerk 4.Licensing Board 5.Selectmen's Office 6.Other Contact Person: Phone#: www.nw s goa/dia Main electric panel in basement Michael Jones 966 Ryan Rd Florence, Ma 01062 Northeast }g Vreeland Design Associates An integrative approach to design engineering and site planning Date: October 15, 2018 To: Justin Annis Northeast Solar 136 Elm Street Hatfield, MA 01038 From: David Vreeland, P.E. Vreeland Design Associates Re: Michael Jones 966 Ryan Rd, Florence, MA: Structural assessment of existing house roof to support proposed solar array. I have investigated the existing roof framing of the house for the proposed PV solar panel installation. The modular built 25'x 40', 1-story ranch style house was constructed in 1968. The rafters are 2x6, appear to be Douglas-fir with a found grade stamp of 1500 psi for bending which corresponds to select structural. The rafters are installed 16" on-center, spanning 12' with a 4/12 roof pitch. The rafters are inline and notched 1" into 2x4 select structural ceiling joists. It appears that the rafters are nailed down through the top of the rafters into the 2x4's. 1 x4 diagonal tension braces are attached to the side of the 2x6 rafters approximately 30"from the ridge and angle down and secured to the side of the 2x4 ceiling joists approximately at mid-span. At the ridge the rafters are secured with metal nail plates. The roofing is new standing seam metal. 16 PV solar panels are to be installed on the south facing house roof. I have reviewed the mounting details for the proposed solar arrays. Based on my calculations and on the specified PV solar panel unit weight of 42± lbs, with the attachment points of the array placed at a maximum of 4' on center and staggered to minimize the load to any one rafter,the existing roof framing of the house and addition are adequate to support the proposed PV solar arrays and the snow and wind load requirements of the current MA State Building Code. Please contact me if you have any questions or need additional information. Sincerely, iw OF s c o� DAVID yG VREELAND 00 CIVIL David Vreeland, PE A No.46317 0.46317 Vreeland Design Associates SSfONAL 116 River Road, Leyden, MA 01337 Phone: (413) 624-0126 Email: dvreeland@verizon.net Fax: (413) 624-3282 EVALUATION REPORT Report Numben 0248 Originally Issued: 09/2012 Valid Througlu 0912013 Division:06—WOOD AND PLASTICS 3.0 DESCRIPTION Section: 06060—Connections and Fasteners 3.1 General Description REPORT MOLDER: EZ Roof Mount L-Foot Kit consists of 5 basic SunModo Corporation components: (1)shoe assembly with captive waterproof 1905 SE Ss'St,Sults A washer, (2)lag bolt to fasten through the shingles to the Vancouver,WA 98681 roof rafter, (3) Hashing that is placed under the row of shingles above the shoe and then over the shoe, (4)L- EVALUATION SUBJECT Foot that is placed over the protruding shoe threads and (5) hex cap that is secured on to the shoe, See SunModo EZ Roof Mount L-Foot Kit for Shingle Figures 1 to 5 in Table 2. Roots 3.2 Materials 1.0 EVALUATION SCOPE: EZ Roof Mount is fabricated from aluminum. Shoe 1.1 Compliance with the following nodes: assembly is fabricated using casting aluminum alloy with dimensions of 2.80 inches in diameter and 1.00 . 2009 International Building CodeO inches in height. It is held in place using one 5/16 inch • 2009 In#ematbnal Residential Code® diameter lag bolt that is 4 inch in length and made of 2006 International Building CodeV stainless steel. Flashing is fabricated from sheet • 2006 international Residential Code® aluminum with dimensions of 10.0 inches in width, 12.5 inches in length and 0.04 inches in thickness. 1.2 Evaluated In accordance with: L foot is a 2.00 inch long unequal leg angle made from • Evaluation Criteria for Joist Hangers and 8063-T6 aluminum with dimensions of 3.00 inches in Miscellaneous Connectors (IAPMO ES EC002- depth, 2.00 inches in width and 0.24 inches in 2011),Approved March 2011 thickness. It contains a 0.375 inch diameter round hole . Acceptance Criteria for Roof Flashing for Pipe with a 0.83 inch diameter chamfer (in base) that is Penetrations(ICC-ES AC286),Approved April 2010 located in the center of the base leg, One slot measuring 1.64 inch long by 0.40 inch wide occurs in 1.3 Properties Evaluated: the center and Is located 0.30 inches from the top edge of the vertical leg, which has a scallop front and rear op Structural face. See Table 2 for component material properties • Weather Protection and figures. 2.0 USES 4.0 DESIGN AND INSTALLATION EZ Roof Mount L-Foot Kit for Shingle Roofs is used to 4.1 Design mount solar systems and other rooftop devices such as satellite dishes an asphalt shingle roofs with wood Tabulated allowable loads shown in Table 1 of this rafters underneath. report are based on allowable stress design (ASD). Adjustments to these values are required for wet EZ Roof Mount is specifically designed to be used for servrce conditions, sustained exposure to elevated installation of solar panels for electric or hot water temperatures, use with fire retardant lumber or with production on roofs with slopes from 3 to 12 units lumber whose specific gravity is less than 0.55(Southern Pine). Allowable values based on fastener vertical in 12 units horfron#ai, strength may be adjusted for duration of loading. See footnotes of Table 1 for more detailed explanation. Page 1 of 4 cerr+abl m mt�ay�Memedanol Aueeeefen of Pt4mWna end�Uohenked lalndeu,w rgba resenY4 rmda ti In,Wiled Etriee No pen stole publio•dmi neey Ae npiaaeoed,Blond in 1 an INelunit n104ed eY+hnt at tr=%W*gQ r NJ fman W by m.M+re OKUWft Modlem oel 1 1--eltidey,mmdal.or*Mormon.v�aA me PrW vwren pembMon a the gAtideer.Pk 7- TAESRPr•Roc W9.172A 171•Witt gy-SM Earl p1Reo"ft Is, "Onwle.Cello neie 4f7s+-Belo—URA �, EVALUATION REPORT Report Number. 0248 Originally Issued: 08/2012 Valid'Through: 09/2013 4.2 Installation Rain test data and thickness of aluminum flashing submitted is in conformance with Acceptance Criteria EZ Roof Mount must be installed using the 5/16 incl/ fbr Roof Flashing for Pipe Penetrations (ICC-ES AC diameter stainless steel -lag screw at each bracket 286-2008). Rain test conformed to Underwriters location as described in the manufacturer's installation Laboratory Standard for Gas Vents, UL 441-96 Section instructions_ Lag screw must penetrate into the roof 25. rafter a minimum of 2 Y2 inches. Prior to installation,the roof rafter shall be bored with the required lead and Test results are from laboratories in compliance with clearance hole for the unthreaded and shank portions ISOAEC 17025. of the lag screw as required in Section 11.1.3 of the NDS -05. Threaded portion of the lag screw shall be 7.0 IDENTIFICATION inserted into its lead hole by turning with a wrench and not driving by a hammer. A die-stamp label in the flashing bearing the name and address of the manufacturer, the model number, Use of auxiliary holes in the Shoe other than the use of IAPMO Uniform ES Marks of Conformity, and this an extra fastener to stop the shoe from rotating during Evaluation Report Number(ER-0248). installapon is outside the scope of this report. Flashing should be installed full under the shingle up to 1A P U the raised portion of the flashing to prevent water M 0 ES ingress under the shingle, No portion of the flashing should be bent upward; the flashing must rest fully ES against the roof shingles, Otherwise the water and wind ® Thr performance may be Impaired. IAPMO#0248 5.0 CONDITIONS OF USE EZ Roof Mount L-Foot Mt for Shingle Roofs described in this report complies with the codes listed in Section 1,0 of this report subject to the following conditions: 5.1 EZ Roof Mount shall be installed in accordance with this report, manufacturer's installation instructions and the codes listed in Section 1.1. 5.2 Calculations to verify the imposed Toads on the EZ Roof Mount assembly do not exceed the allowable loads contained in Table 1 of this report shall be submitted to the code official when requested. Calculations shall be prepared by a registered design professional when required by the statues of the jurisdiction where the work is constructed. i 6.0 EVIDENCE SUBMITTED Testing and analysis data submitted is in conformance with Evaluation Criteria for Joist Hangers and Miscellaneous Connectors OAPMO ES EC 002-2011). Page 2 of 4 EVALUATION REPORT F Report Numben 0248 • Originally Issued: 09/1012 Valid Through 0913013 TABLE 1. ALLOWABLE LOADS FOR EZ ROOF MOUNT L-FOOT KIT(lba.)I*Z-"`s Ultimate Load Test Load at Test Load at Calculated Load re below) Test Value 0.350 inch 0.125 inch Fastener/Metal Allowable Loa (see figure below) F'.S.-3.0 deflection deflection Stren Design Load Uplift(Withdrawal) 7I5 11800 695 340 340 Lateral 260 1 240 1 130 153 130 Notes 1. Allowable load values are based on the least value from the ultimate load of three tests(strength limit),tested load at 0.125 inch deflection(deflection limit),calculated fastener capacity(withdrawal or lateral)for wood with a specific gravity of 0.55(Southern Pine)or allowable stress of the aluminum L-foot connector. 2. Allowable load values are based on lumber with all of the following characteristics. a. Located in dry service conditions where the moisture content does"exceed 19%for an extended period of time such as in most covered structures. b. Located where it does not experience sustained exposure to elevated temperatures that exceed 100°F. For any other conditions,allowable table values shall be multiplied by the related adjustment factor(s)(C,,, and/or C,)in accordance with the National Design Specification for Wood Construction(NDS-05), 3. Allowable load values are based on lumber with a specific gravity of 0.55(Southern Pine or equal). 4. Allowable load values for withdrawal are based on a minimum penetration of2'� inches into the roof rafter by one 5/16 inch x 4 inch long stainless steel lag screw. 5. Allowable values may not be increased for load duration in accordance with Section 10.3.2 of the NDS-05- Uplift Lateral Page 3 of 4 EVALUATION REPORT. Report Numbers 0248 WgInally Issuedc 09/2042 Valid Throught 0"013 TABLE 2:MATERIAL PROPERTIES Cam nent h4aterial Shoe ' Aluminum alla ANSYAA A380.0 Werproof Washer FPDM with duromew raflyA of 60 LM Bolt 304 stainless steel ASTM A 240 L-foot I Aluminum alloy 6063-T6 ASTM B221 Hex Cap Aluminum alio ANSI/AA A380.0 Flashing Aluminum alloy 1060 ASTM B209 EZ ROOF MOUNT COMPONENTS Figurel:Shoe Assembly Figure 4:Hex Cap Figure 2:Lag Boft Figure 5:Flashing Figure 3:L-foot Page 4 of 4 EVALUATION REPORT Report Number: 0248 = Originally Issued: 0912012 Valid Through: 09/2013 TABLE 1: ALLOWABLE LOADS FOR EZ ROOF MOUNT L-FOOT KIT(lbs.)I"r"*44 Ultimate Load Test Load at 'fest Load at Calculated Load u re bie below) Test Value 0.250 inch 0.125 inch Fastener/Metal Allowable (age figure benign Load F.S.-3.0 deflection deflection Strength Uplift(Withdrawal) 715 1,800 695 340 340 Lateral 1 260 240 1 130 153 1 130 Notes 1. Allowable load values are based on the least value from the ultimate load of time tests(strength limit),tested load at 0.125 inch deflection(deflection limit),calculated fastener capacity(withdrawal or lateral)for wood with a specific gravity of 0.55(Southern Pine)or allowable stress of the aluminum L-foot connector. 2. Allowable load values are based on lumber with all of the following characteristics: a. Located in dry service conditions where the moisture content does not exceed 19%for an extended period of time such as in most covered structures. b. Located where it does not experience sustained exposure to elevated temperatures that exceed I00°F. For any other conditions,allowable table values shall be multiplied by the related adjustment factors)(C„, and/or Q in accordance with the National Design Speciftcatiod for Wood Construction(NDS-05). 3. Allowable load values are based on lumber with a specific gravity of 0.55(Southern Pine or equal). 4. Allowable load values for withdrawal are based on a ndnimum penetration of 2'r4 inches into the roof rafter by one 5116 inch x 4 inch long stainless steel lag screw. 5. Allowable values may not be increased for load duration in accordance with Section 10.3.2 of the NDS-05. Latera! � ! i | VANES NmClomn End ClWnp AILOXINRIDGE ' LLA Q21§4 A,Mid ^ | � ' --- - \ . ! 1 ' ' � !uua� Ta 1 -W - 1 ' \ � i AvIcal Flush Mount AsTaX-Nn View Mid Clamp "*~ ' -00 | � � ' InonPidge Rai / `�- -~~~ \ � / u�' �'�� ---'~—`----- - ' on ~~- �� , - ( ( \ � Mid Clamp svuclamp , / i ! � ' - � . » " ° ! � � . - . . ~ � i | ! � � L 314"=V~ ------------- ^ ' m .� Northeast Sol II IIII Typical feet placement w/ 16" o.c. rafter spacing II II I r 1 I I I I Typical feet placement w/ 24" o.c. rafter spacing 1 ZL i I z, {. 4 4 4' (9 LG I nnovation Life's Good Better LG NeON R MMM MM U .. The LG NeON®R is a powerful solar module that provides world-class performance.A new cell structure that eliminates electrodes on the 60 cell front maximizes the utilization of light and enhances reliability.The �p�p LG NeON®R is a result of LG's efforts to Increase customer value DVE beyond basic efficiency.The NeON°R features enhanced durability C LO US III(I" and performance under real-world conditions,an enhanced warranty and an aesthetic design suitable For roofs. Enhanced Performance Warranty .. High Power Output il LG offers a 25-year product warranty for LG NeON`"'R, le The LG NeON°R has been designed to including labor,in addition to an enhanced performance significantly enhance its output,making It efficient warranty.After 25 years,LG NeON R is guaranteed to even in limited space. produce at least 88.4%of its initial power output. Roof Aesthetics ® Outstanding Durability LG NeON`'R has been designed with aesthetics in mind: With its newly reinforced frame design,LG the lack of any electrodes on the front creates an NeON°R can endure a front load up to 6000 Pa, improved,modern aesthetic. and a rear load up to 5400 Pa. �•• ' Near Zero LID (Light Induced � Better Performance on a Sunny Day (' ••..�.. • LG NeON'R now performs better on sunny L� Degradation) days,thanks to its improved temperature coefficient. The n-type cells used in LG NeON`�'R have almost no boron.This leads to less LID(Light Induced Degradation)right after installation. About LG Electronics LG Electronics is a global player who has been committed to expanding its capacity,based on solar energy business as its future growth engine.We embarked on a solar energy source research program in 1985, supported by LG Group's rich experience in semi-conductor,LCD,diemistry,and materials industry.VVe sucf essfully released,rst Mono X®series to the market in 2010,which were exported to 32 countries in the following 2 years,thereafter.In 2013,NeON-(previously known as Mono X®NeON)&2015 NeON2 with CELLO technology won"Intersolar Award",which proved LG is the leader of innovation in the industry. LG NeON"' R EMM• Mechanical Properties Electrical Properties(STC*) Cells 5x`10 Module 365 360 355 350 Cell Vendor LG Maximum Power(Pmax) 365 360 355 350 Cell Type Monocrystalline/N-type MPP Voltage(Vmpp) 36.7 36.5 36.3 36.1 Cell Dimensions 161.7 x 161.7 mm/6 inches MPP Current(Impp) 9.95 9.87 9.79 9.70 Dimensions(L x W x H) 1700 x 1016 x 40 mm Open Circuit Voltage(Voc) 42.8 42.7 42.7 42.7 66.93 x 40.0 x 1.57 inch Short Circuit Current(Isc) 10.8 10.79 10.78 10.77 Front Load 6000Pa Module Efficiency 21 1 20.8 20.6 20.3 Rear Load 5400Pa Operating Temperature -40--90 Weight 18.5 kg Maximum System Voltage 1000 Connector Type MC4 Maximum Series Fuse Rating 20 Junction Box IP68 with 3 Bypass Diodes Power Tolerance(%) 0-+3 Length of Cables 1000 mm x 2 ea STC(standard Test Condition)Irradiance 1,000 W/m',Ambient Temperature 25°C,AM 1 5 Glass Tempered Glass with AR Coating The nameplate power output Is measured and determined by LG Electronics at Its sole and absolute discretion Frame Anodized Aluminium Electrical Properties(NOCT*) Certifications and Warranty Module 365 360 355 350 Certifications IEC 61215,IEC 61730-1/-2 Maximum Power(Pmax) 275 271 267 263 UL 1703 MPP Voltage(Vmpp) 36.6 36.4 36.2 36.0 IEC 61701 (Salt mist corrosion test) MPP Current(Impp) 7.51 7.45 7.39 7.32 IEC 62716(Ammonia corrosion test) Open Circuit Voltage(Voc) 40.2 40.2 40.2 40.1 ISO 9001 Short Circuit Current(Isc) 8.70 8.69 8.68 8.67 Module Fire Performance(USA) Type 1 *NOCT(Nominal Operating Cell Temperature).Irradiance 800 W/m',ambient temperature 20°C,wind speed 1 m/s Fire Resistance Class(CANADA) Class C(ULC/ORD C1703) Product Warranty 25 years Output Warranty of Pmax Linear warranty** Dimensions(mm/in) a _•v�-a2 z,,4r, .,3, .y-ir q8 Temperature Characteristics a NOCT 44±3°C Pmpp -0.30%/°C Voc -0.24%/°C Isc 0.04%/°C Characteristic Curves 1o0ow 1000 vRQQVV eao U 60OW 600 4 400 - - 2.00 _ --....., Voltage(V) �! S 000 500 1000 15.00 2000 2500 3000 35.00 4000 4500 { 140 a 100 1 so 50 40 20 L i a _ a $, 0 Temperature(-C) X40 -25 0 2s 50 75 e0 *The distance between the center of the mounting/grounding holes. ® LG North America Solar Business Team Product specil1cations are suh)ect to change without notice. Q L6 Electronics U.SA.Inc DS-T1-72-W-G-P-EN-60630 Life's Good 1000 Sylvan Ave,Englewood Cliffs,NJ 07632 ~� Copyright©2017 LG Electronics.All rights reserved. Innovation for a Better Life Contact tg.solar@(ge.com 01/01/2017 www.igsolarusa.com Q