24C-141 (4) 90 FRANKLIN ST BP-2018-0893 GIS#: COMMONWEALTH OF MASSACHUSETTS Map:Block:24C- 141 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category:SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-0893 Project# JS-2018-001635 Est.Cost. $46000.00 Fee:$75.00 PERMISSIONIS HEREBY GRANTED TO: Const Class: Contractor: License. Use Group: TRINITY SOLAR 104144 Lot size(su. f): 9452.52 Owner: GOODMAN TAN zoning URB(100)/ Applicant: TRINITY SOLAR AT. 90 FRANKLIN ST ApplicantAddress: Phone: Insurance: 32 GROVE ST (508) 577-33910 WC PLYMPTONMA02367 ISSUED ON.3/612018 0:00:00 TO PERFORM THE FOLLOWING WORIL•40 ROOF MOUNTED SOLAR PANELS AT 11.8 KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Rough: Rough: House House# Foundation: 9(� Driveway Final: Final: Final: 1— Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: __ ��///� � Final: Smoke: Final: a94 2V/Wlff THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REG Certificate of Occuoan �� Signature: FeeType: Date Paid: Amount: Building 3/620180:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner U198 81 /HECTOR JOB NO.: WIND PRESSURE SUBJECT: WIND PRESSURE E M G 1 n E E R S PROJECT: Ian Goodman Residence Components,and Cladding Wind Calculations Label: Isolar Panel Array Note: Calculations per ASCE 7-10 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 117 Notes: Exposure Category: C Risk Category: II ADDITIONAL INPUT& CALCULATIONS: Height of Roof, h [ft]: 35 (Approximate) Comp/Cladding Location: Gable Roofs 27°<8<_45° Enclosure Classification: Enclosed Buildings Zone 1 GCo: 1.0 Figure 30.4-2C (enter largest abs. value) Zone 2 GCo: 1.2 (enter largest abs.value) Zone 3 GC,: 1.2 (enter largest abs.value) a: 9.5 Table 26.9-1 Ze [ft]: 900 Table 26.9-1 Kn: 1.01 Table 30.3-1 Kr: 1 Equation 26.8-1 Kd: 0.85 Table 26.6-1 Velocity Pressure, qh [psf]: 30.2 Equation 30.3-1 GCp;: 0 Table 26.11-1 (largest abs. value) OUTPUT: p =4b GCS — GC i Equation 30.9-1 Zone 1 Pressure, p[psf]: 30.2 psf(1.0 W, Interior Zones') Zone 2 Pressure, p[psf]: 36.3 psf(1.0 W, End Zones`) Zone 3 Pressure, p [psf]: 36.3 psf(1.0 W, Corner Zones' Within a) (a=3 ft) YECTOR JOB NO.: U1982-0526-181 SUBJECT: CONNECTION PROJECT: Ian Goodman Residence Lag Screw Connection Capacity: Demand: Lag Screw Size [in]:FNDS pressure Maz Maz. Trib. Cd: .2 r Max. Uplift Embedment' [in]: (0.6 Wind) Tributary Area Force (Ibs) (psf) Width (ft) (ft )Grade: Zone Capacity [lbstin]: .2A 1 18.1 6.0 16.5 2Number of Screws: 2 21.8 6.0 16.5 359 Prying Coefficient: 3 21.8 6.0 16.5 359 Total Capacity [lbs]: Demand< Capacity: CONNECTION OKAY 1.Embedment is measured from the top of the framing member to the beginning of the tapered tip of the lag screw. Embedment in sheathing or other material is not effective.The length of the tapered tip is not partof the embedment length. 2.'Max.Trib Area'is the product of the'Max.Tributary Width'(along the rails)and 1/2 the panel width/height (perpendimlartothe rails). y ECTOR JUB ND.: U,962_D526-,8,SUBJECT: GRAVITY LOADS PROJECT: Ian Goodman Residence Roof 1 and Roof 2 CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original ROOF DEAD LOAD D pitch loading Roof Pitch112 malffim Composite Shingles 2.3 1.15 2.0 psf 112' Plywood 1.2 1.15 1.0 psf Framing 3.0 psf Insulation 0.0 psf 112' Gypsum Clg. 0.0 psf M, E& Misc 0.0 psf DL 6 psf PV Array DL 4 psf ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-10,Table 4-1 Roof Live Load With PV Array [psf] Massachusetts State Building Code(780 CMR Ch w/Solar Panel Roof Slope [x:12]: 6.9 6.9 Roof Slope [1: 30 30 Snow Ground Load, pg [psf]: 40 40 ASCE 7-10,Section 7.2 Terrain Category: C C ASCE 7-10,Table 7-2 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-10,Table 7-2 Exposure Factor, Ce: 0.9 0.9 ASCE 7-10,Table 7-2 Thermal Factor, Ct: 1.1 1.1 ASCE 7-10,Table 7-3 Risk Category: II II ASCE 7-10,Table 1.5-1 Importance Factor, Is: 1.0 1.0 ASCE 7-10,Table 1.5-2 Flat Roof Snow Load, pt[psf]: 35 35 ASCE 7-10,Equation 7.3-1 Minimum Roof Snow Load, pm [psfJ: 0 0 ASCE 7-10,Section 7.3.4 Unobstructed Slippery Surface? No Yes ASCE 7-10,Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-10,Section 7.4 Roof Slope Factor, Cs: 1.00 0.67 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, ps [psf]: 35 23 ASCE 7-10, Equation 7.4-1 Design Snow Load, S [psf]: 35 23 VECTOR LOAD JOB NO.: R1 SUBJECT: LOAD COMPARISON E n G I n E E R E5 PROJECT: Ian Goodman Residence Roof 1 and Roof 2 Summary of Loads Existing With PV Army D[ps j ] 10 Lr[pef] 20 0 S[psf]1 35 1 23 Maximum Gravity Loads: Existing With PV Array D+L,[psf] 26 30 ASCE 7-10,Section 2.4.1 D+S Ipsf] 41 33 ASCE 7-10,Section 2.4.1 Maximum Gravity Load [psfl:l 41 1 33 Ratio Proposed Loading to Current Loading: BO% OK The gravity loads in the area of the solar array are decreased;thus,the stresses of the structural elements are decreased.Therefore,the requirements of Section 807.4 of the 2015 IEBC as referenced in 760 CMR Chapter 34,9th Edition are met and the structure is permitted to remain unaltered. Y ECTOR JOB NO.: U1982-0526-181 SUBJECT: GRAVITY LOADS PROJECT: Ian Goodman Residence Roof 3 North West end CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original ROOF DEAD LOAD (D) pitch loading Roof Pitch/12 Composite Shingles 2.3 1.15 2.0 psf 1/2" Plywood 1.2 1.15 1.0 psf Framing 3.0 psf Insulation 0.0 psf 117' Gypsum Clg. 0.0 psf M, E &Misc 0.0 psf DL 6 psf PV Array DL 4 psf ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psfJ 20 ASCE 7-10, Table 4-1 Roof Live Load With PV Array [psf] 0 Massachusetts State Building Code (780 CMR Ch w) Solar Panel SNOW LOAD (S): Existing Array Roof Slope [x:12]: 6.9 6.9 Roof Slope [°]: 30 30 Snow Ground Load, ps [psf]: 40 40 ASCE 7-10,Section 7.2 Terrain Category: C C ASCE 7-10,Table 7-2 Exposure of Roof: Fully Exposed Fully Exposed ASCE 7-10,Table 7-2 Exposure Factor, Ce: 0.9 0.9 ASCE 7-10,Table 7-2 Thermal Factor, C,: 1.1 1.1 ASCE 7-10,Table 7-3 Risk Category: II II ASCE 7-10,Table 1.5-1 Importance Factor, I,: 1.0 1.0 ASCE 7-10, Table 1.5-2 Flat Roof Snow Load, p,[psf]: 35 35 ASCE 7-10, Equation 7.3-1 Minimum Roof Snow Load, pm[psf]: 0 0 ASCE 7-10, Section 7.3.4 Unobstructed Slippery Surface? No No ASCE 7-10, Section 7.4 Slope Factor Figure: Figure 7-2b Figure 7-2b ASCE 7-10, Section 7.4 Roof Slope Factor, C,: 1.00 1.00 ASCE 7-10, Figure 7-2 Sloped Roof Snow Load, p, [psfJ: 3535 ASCE 7-10, Equation 7.4-1 Design Snow Load, S[psf]: 35 35 \ Fm Fm 9 \������ PN' pG E6 (PMI IWI E.(MI) \_\ JOB NO.: U19820626-101 OFLX1 OFLXI LMO IW 1}W.MO xx ::://��' E! fl O I'1 C C Fi 9 pM�SxseITPOEP 9PFWe 6PXx SPX12 I<00.Wx xe.i PROJECT: Ien GOo0men Reel6enpe SUBJECT: BEAMS NF VE DESIGN LOAD& Loa01}yee: 9nuw IJve DBFO VL 120) LYL 12,0%iWEI Roof 36 20 8 CRITERUIN Dn Dii Du ISL L9L1!aRtw[I !w �W !xw.ouu et Solar 3.5 A.., 120 240 m. n F36 1 D 1!,. 11. ANO,OAt em B 210 160 .Ll m Eyes EL n.WS lewd xe,Wb.5o5 eW C 600 800 $1. xO.w WIXjI eW Dm Polnl Ou D,— W1 A111 LNG RCpI FIWr Wdl Llve 9der Pdm D41 Loetl Loetl I $ (SEE (SEE 1.ECL LsgIM1 Trlb Tr'A Ttlb Loml Lantl Laetl F 'e' 'Pu 9a 3 1�r Mm. M®.. V� Va.,. O1L OMw. CONO GONG OLR LMM L'IR) IRI (11) IRI (01) (0) F. to (ft) IIb) (lb) Grade Slee a b c, Co Gv R.(Ib) R,(S) (ft-lb) (M14b) (lb) (lb) (ln) (In) G) 'C') Comb CIKKk rnn13 11.6 2 x.0 2 8PFp2 2e8 1.16 1.15 130 532 532 1529 18W I90 1]06 0625 1.150 0210 0.515 081M JOB NO.: 1 ECTOR SUBJECT: SOLAR LAYOUT E PROJECT: Ian Goodman Residence i Cw�Pp!tOBE ilE1gCO MV W]L 6FEEi 90 FRANKLIN ST EP-2018-0686 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON Map: 24C Lot: 141 ELECTRICAL PERMIT Permit. Electrical Category. 40 ROOF MOUNTED SOLAR PANELS AT 11.8 KW Penn[# Electrical PERMISSION IS HEREBY GRANTED TO: Project p JS-2018-001635 Est.Con: Contractor: License: Fee: $60.00 TRINITY SOLAR MASTER ELECTRICIAN 21233 Owner: GOODMAN IAN Applicant: TRINITY SOLAR AT. 90 FRANKLIN ST Applicant Address Phone Insurance 32 GROVE ST (508) 577-3391 () C- Liability, EGGCC000065616 PLYMPTON MA02367 ISSUED ON:3/62018 0:00:00 TO PERFORM THE FOLLOWING WORK.• 40 ROOF MOUNTED SOLAR PANELS AT 11.8 KW Call In Date: Date Requested Inspection Dete/SignOff: Relnspert', Treuc"TG: Special Instructions x Rough x Special Instructions: SKE Called In: _ Signature: Fee Twe:: Amount: DatePaid Electrical $60.00 3/6/2018 0:00:00 4182 212 Main Street,Phone(413)587-1244,Fax(413)587-1272-Inspector of Wires -Roger Malo