Loading...
35-151 (7) 764 RYAN RD BP-2018-1076 GIs#: COMMONWEALTH OF MASSACHUSETTS Map:Block:35- 151 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Categorv: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2018-1076 Proiect# JS-2018-001939 Est.Cost: $30503.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: VIVINT SOLAR DEVELOPER LLC 070940 Lot Size(sq.fl.): 29577.24 Owner: SCARBOROUGH HENRY F&LUCILLE Zoninyv Applicant: VIVINT SOLAR DEVELOPER LLC AT.- 764 RYAN RD Applicant Address: Phone: Insurance: 150 PADGETTE ST UNIT B (413) 259-8044 O WC CHICOPEEMA01022 ISSUED ON:4/20/2018 0:00.00 TO PERFORM THE FOLLOWING WORK:47 ROOF MOUNTED SOLAR PANELS @ 13.865KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of OccuoancV signature: FeeTvoe: Date Paid: Amount: Building 4/20/2018 0:00:00 $75.00 212 Main Street,Phone(413)587-1240,Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner IV7CP Department use only City of Northampton Status of Penh: Building Department Curb Cut/Ddveway Permit 212 Main Street Sewer/Septic Availability Room 100 WaterNVell Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot(Site Plans Othe pea r �.� APPLICATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEM LIS A ONE OR TWO FAMI Y D ELLING APR SECTION 1 -SITE INFORMATION T Is s eompl9t by office 1.1 Property Address:.,,�1 �/6 r � ot Map .3S LUnit �J Zone Overlay District Elm SL District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT e�2.1 O ner of Reeord: c�mrhLnifauah 7 Name(Print) Curr/q �J/ Telephone 7 Signature 2.2 Authorized Acent: Savina Cervone 150 Padgette St, Chicopee, MA 01022 MNa Print) Current Mailing Address: �LC416 62l e110 413-2174033 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completetl by permit applicant 1. Building CU/_ CVO). 06 (a)Building Permit Fee 2. Electrical '/ �J L/O (b)Estimated Total Cost of ry -J Construction from 6 3. Plumbing Building Permit Fee 4. Mechanical(HVAC) -7 5. Fire Protection 6. Total=(1 +2+3+4+5) Check Number This Section For Oficial Use Only Building Pemlit Number Date Issued'. Sign,tune A L`�z Z45 i Build Commissioner/Inspector of Buildings Date yl Section 4. ZONING Aa information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Depanmem Lot Size Frontage Setbacks Front Side L: R: L R: Rear Building Height Bldg.Square Footage % Open Space Footage % (Lot area minas bldg&paved arkin N of Puking Spaces Fill: volume&Lwahon A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO O DONT KNOW O YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO O DONT KNOW O YES 0 IF YES: enter Book Page and/or Document A B. Does the site contain a brook, body of Water or wetlands? NO O DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained 0 ' . , Date Issued: C. Do any signs exist on the property? YES 0 NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,gradin),excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES,then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House ❑ Addition ❑ Replacement Windows Alteration(s) ❑ Roofing ❑ Or Doors D Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [[] siding[IS] Other 101 Brief Description of Proosed �q Installation oteroof mounted photovoltaic so_Iacsystems# ofmDdules 7 / �]��eLe rte(] l� erml L��1 Alteration of existing bedroom Ve Addigg'new betlroom VesVe N nk c�c. Attached Narrative Renovating unfinished basement yes No Plans Attached Roll -Sheet 5a. If New house and or addition to existina housing, complete the followina: a. Use of building One Family Two Family Other It. Number of roams in each family unit Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each_ g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction Is construction within 100 ft. of wetlands? yes No. Is construction within 100 yr. floodplain VesNo I. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? yes_No. I. Septic Tank_ City Sewer_ Private well_ City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, as Owner of the subject property hereby authorize to act on my behalf, in all matters relative to work authorized by this building permit application. Signature of Ovvner Date I, Vivint Solar Developer. LLC as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true antl accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Savina Cervone Pri ame afore of Ovmer/Agent Da SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor: Not Applicable C Name of License Holds,, John A Jalbert _ CS070940 License Number 150 PadPette St Unit B. Chicopee, MA 01022 _ 03/25/2019 Address Expiation Date 4 13 :.17-4033 Signature Telephone 9.Reaistered Home Improvement Contractor: Not Applicable ❑ VIVINT SOLAR DFVFI OPER I I C /.Iohn A lalbert 170848 Company Name Registration Number 1800 W Ashton Blvd. Lehi UT 84043 1/4/2020 Address Expiration Dale Telephone 413-217-4033 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(6)) Workers Compensation Insurance affidavit must be completed and submitted With this application. Failure to provide this affidavit vd11 result in the denial ofthe issuance ofthe building peril. _ Signed Affidavit Attached Yes....... ❑ No.._... ❑ 11. - Home Owner Exemption The current exemption for"homeowners"was extended b include Owner-occupied Dwellings of one(1) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner:Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one hone in a two-year Period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Offi_ial,on a form acceptable to the Building Official,that he/she shall be responsible for all such work Performed under the Latrine permit. As acting Construction Supervisor your presence on thu job site will be required from time to time,during and upon completion ofthe work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability ofEmployers to Employees for injuries not resulting in Death)ofthe Massachusetts General Laws Annotated,you may be liable for persons) you hire to perform work for you under this permit. The undersigned"homeowner"certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusehs General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by bey MGL c 111, S 150A. Address of the work: 7co--/ The debris will be transported by: yivint solar Developer LLc The debris will be received by: vivint solar Developer LLC Building permit number: Name of Permit Applicant savina Cervone Date Signature of Permit Applicant The Commonwealth ofMassachuselts pp Department of Industrial Accidents 'C Ogee ss Strest Suite 1 I Congress Street,Suite 700 Boston,MA 02114-2017 IMF www.mass.govldia Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Name (Business/Organisation/Individua0: Vivint Solar, Inc. Address' 1600 W Ashton Blvd. City/State/Zit: Le - T a Phone#: _a 117 Are you an employer?Check the appropriate box: Type of project(required): 1.Q I am a employer with 253 _ 4. ❑ I am a general contractor and I . etrtployees(full and/or part-time)." have hired the sub-contmcmrs 6. New construction 2.❑ 1 am a sole proprietor or partner- listed on the attached sheet. 7. ❑Remodeling ship and have no employees Thee subcontractors have g ❑Demolition working for me in any capacity. emptoyces and have workers' [No workers' camp. insurance comp.insurance? 9. E]Building addition required.] 5. ❑ We we a corporation and its I O.❑ Electrical repairs or additions 3.❑ I am a homeowner doing all work officers have exercised their 11.❑Plumbing repairs or additions lf.seNo workerscora m ' right of exemption per MGL Y [ P 12,[]Roof repairs insurance required.] t c. 152,§I(4),and we have no employees. [No workers' 13.El Other Solar Installation .— comp.insurance required.] 'Any aDPllc:un the checks box#1 must also fill out the mals.below showing their workers'com,mi ation policy infomation. y fhuuci .t ery who submit this affidavit indicating day am doing all work and Then hire omside cuneamon met submit a new amdevit indicatirasuch. IComramms that check this box must anachedan addihmW sheet showing the come of the mbcontramos and haze shethaor apt muse entities hnve employees. If the subcontractors have employees,thry must Drovide their workers'comp.p.lipy numbs. lam an employer thatisproviding,workers compensation insurancefor my employees. Below is thepolicy andjob site information. Insurance Company Name. Zurich American Insurance Company _ Policy#or Self-ins.77LLi� 1_ ic. #: W9,509601302 Expiration Date: AV17201Q Job Site Address:/(Q _.j 11 _ City/State/Zip;f-b1. Attach a copy of the workers' pensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to$1,500.00 and/or one-year imprisonment,as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby terrifV71 ams and pen t' perjury at the information provided above is true and correct Sibmaturc ___ _._ ....Date:Phone#: Ani-37 Oficial use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority(circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: HbqlaOoewmr AOrixs M 1NguN11w� 11ff NI smbCO1rtBACTOR Wm: p8: BNTCartl 1 0111192020 VIVINT SOLAR y r F JOHN JAIFEE[itO 1000 W. ON BC LEHI,UT 0!099 uriderswiew1, vNa049e0o BopM sm of►BY91a 891wy Bo0rd of Bu11Mq Ragwlw y OM BWt6eb Lkon9r: CBd708W ; COLWAW OG Sup0Mxor JOINAJY.BBRi'' . , NIUIOLL SO0T"N11MRTON Expintiom Commi.Oio 0012514010 'a DATEIMWODmYn ACORO CERTIFICATE OF LIABILITY INSURANCE lad 1120'] THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER.THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EMEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AELPHOR12ED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: H the certificate holder is an ADDITIONAL INSURED,the policy(iss)must have ADDITIONAL INSURED provislons or be endorsed. If SUBROGATION IS WANED,subject to the hurls and conditions of the policy,cedein policies may require an andersemMr. A Statement on this certificate tices not confer lights In the certificate holder in lieu of such endoneemenl(s). PROWLER NER$H BSA NL NAYS ONE H .5L TE 130VG.H.Eatl (uc. xP) DENJER CU STREET H ' E'xm Alin Cema CCRPnµ. lwmarsh'nT Fal:212-9!6-038 OW — c T IN9URFFLSf RFFO1mIXG COVEMOE MAICr INERLARERA A OSUrOaILiEuViCINS '.. unmNv m Sohl lnc. Lvsoa.Zuntll Amo(rtan lnttlanm C""' _ - :16515 Lhnm 511,,0evvbp.. C NaUNDRO.RF1111il Zu(Z.1111111.1A.CAJ' 40111 16300 AA1o0 Bad MaITREP. N.......Y lnzrVY,Company X42}0] LJ1,IT 64943 INSURERS mSURER F.. _ -. .. COVERAGES CERTIFICATE NUMBER: FEE 103174122.15 REVISION NUMBER: 5 THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LIS-ED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOIWITHSTANOING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN,THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. ILLR RTYPEOFIXBYRANGE =L=1 POIKYXUMBER POLILYEfi LM3 0 % COMMEROPLGMERALLIABILI 37I65C011]EN 01;292011 II0I12018 EMN.ECUIREXC= 8 010 ,300 CLA1Ms+MAOE X FCc11 RACE ro aE�rED - . - Eaocognnul . 31 a 10 NEXP ,y-N—) _. corAs _. - IG ORC PERPONAL&PLEVINJURYY a - _. 1,RWDC TE N L AGCREGA'E LImNr APPUC PER GErvEUL AE'NEGATE 5 2roO,ocB x 'C_,' __ 1ECT - _��wc PRooucTe-coNPIOP Ace s. _ 1,300.CUJ 5 .THN B AGTOMMILEUAeILITY BAP509601W3 .11101120'1 1PTITO10 LEin.MBINEO ALESPESINGLE UNXT 5 1,:100000 xnw"TO BODILY INJURY IPa pmwnl S OJILl SCROESULFO 'EOOILY INJURY(PwawOanU S avMEU OGE9OANAGE x J Oe ONLY A q OSONLV (0'v tt;Wapll CQFNCCII JN X UMBREL4LMB % Occua 3]1650021]EN :0112912011 111011ID18 EACH OCCWRErvcE E 5000.000 Z E%OESS WB CUINI.AOE 'GL Orly AGGREGRE $ 5000000 "I RFIENTI.I$ $ WC5096013031A051 7 111m1$O1B % 9TPTUTE ORiH- p ANDEMPHASIS�ei�ry YIN U/C5306019031MA 11,U11201T 11101120'8 1,000000 OPP EmBE EaL1W � NIA FI FAFF ACC DEN! E jManeNeryEn xxj EL DISEASE_EFEMPLOYEE$ 1NoTOO DESCRCTION OF OPERATI ONS Will ELDSEASE-FQ1l�$ I,MCDO0 D EXCESS LABII ITY GA13EXC8889191V 110.201' I1101l16 CACI OCCURRENCE 55000,TY AIaOFLOMY AGGREGATE $5000,000 OEe[mPRON OF OPEMPONS I LOCATIONS I VEHICLES IACWD 101.Met-1 RamNsatlnd.N, M WI Il men 1,Is NvQ.da CERTIFICATE HOLDER CANCELLATION L!vl VCUba.m", SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE 212 Mein 5vcvl THE EXPIRATION DATE THEREOF, NOTICE VVII BE DELIVERED M ROINamnoe MA 01"60 ACCORDANCE WITH THE POLICY PROVISIONS. AUTIORYB)REPRESENTATNE ..... r Yen11 U.M. Kathleen M,PaRLA, ./ FaU JA. 0ISSB-2016 ACORD CORPORATION. All rights reserved. ACORD 25(2016101) The ACORD name and logo are registered marcs of ACORD vivint1800 W Ashton Blvd- Le'^.i. UT 63033 Structural Group J.Matthew Walsh, SE, PE Jon P. Ward, SE, PE Senior Structural Engineering Manager Structural Engineering Manager james.walsh@vivintsolar.com jon.ward@vivintsolar.com April 18.2018 Re: Structural Engineering Services Scarborough Residence 764 Ryan Rd, Florence, MA S-5889340; MA-04 To Whom It May Concern: We have reviewed the following information regarding solar panel installation on the roof of the above referenced home: 1. Site Visit by a representative from our office under my supervision identifying specific interior and exterior site information including the condition of the existing roof system and the size, spacing, and condition of existing structural framing members. Information gathered during the site visit includes photographs, sketches, and verification forms. 2. Design drawings of the proposed PV System layout, including details to mount the new solar panels to the existing roof. Based on the above information,we have evaluated the structural capacity of the existing root system to support the additional loads imposed by the solar panels and have the following comments related to our review and evaluation: A. Description of Residence: The existing residence is typical wood framing construction with a maximum of two layers of composite shingle roofing. All wood material utilized for the roof system is assumed to be Spruce-Pine-Fir#2 or better with standard construction components and consists of the following: • Roof Section 1: Dimensional lumber -2x4 at 16"on center and 1 x4 collar ties at 16" on center. Survey photos indicate that there was free access to visually inspect the size and condition of the roof members. The interior horizontal length from ridge to Save used for design verification is 12.93'. Based on the span of the existing rafters for this roof section, a structural upgrade is required to strengthen the roof system. Select from options presented in paragraph C below, and locate the upgrade between 4.7'and 8.3'from the ridge. • Roof Section 2: Dimensional lumber - 2x4 at 16" on center and 1 x4 collar ties at 16" on center. Survey photos indicate that there was free access to visually inspect the size and condition of the roof members. The Interior horizontal length from ridge to save used for design verification Is 12.93'. Based on the span of the existing rafters for this roof section, a structural upgrade is required to strengthen the roof system. Select from options presented in paragraph C below, and locate the upgrade between 4.7'and 8.3'from the ridge. B.Loading Criteria 8.43 PSF= Dead Load (roofing/framing) 2.59 PSF= Dead Load (solar panels/mounting hardware) 11.02 PSF=Total Dead Load 20 PSF= Roof Live Load 40 PSF= Ground Snow Load (based on local requirements) Wind speed of 90 mph(based on Exposure Category B-the total area subject to wind uplift is calculated for the Interior, Edge, and Corner Zones of the dwelling.) Page f of2 X i §r ints Page 2 of 2 C.Approved Structural Upgrade Options The method of strengthening the roof shall be determined by the Licensed Construction Supervisor (CSL)under my direction and based on actual field conditions such as access to the attic and location of load bearing walls, and shall be chosen from the following options: 1. Knee wall or purlin constructed of either, 2x4's or 2x6s with top and bottom plates attached to the rafters and attic joists respectively, shall be built in tha attic. The top plate of the support shall be as described above. The bottom plate shall be within 12"of a parallel load bearing wall below the attic. The maximum permitted angle of the knee wall or purfin struts shill be 45 degrees from vertical_ D.Solar Panel Anchorage 1. The solar panels shall be mounted in accordance with the most recent"Unirac, Inc. Installation Manual", which can be found on the Unirac, Inc. website (www.unirac.com). If during solar panel installation, the roof framing members appear unstable or deflect non-uniformly, our office should be notified before proceeding with the installation. 2. The solar panels are 1111'thick and mounted 41,T off ;he roof for a total height off the existing roof of 6". At no time will the panels be mounted higher than 6"above:he existing plane of the roof. 3. Maximum allowable pullout per lag screw(5/16"x 411x') is 2351bs/inch of penetration as identified in the National Design Specifications(NDS)of timber construction specifications for Spruce-Pine-Fir. Based on our evaluation, the pullout value, utilizing a penetration depth of 21/", is less than the maximum allowable per connection and therefore is adequate. 4. The maximum allowed spacing was calculated for the Wind Speed shown in paragraph B above,using the wind load uplift procedures of ASCE 7-10 and is specified below. The following values have been verified by in- house testing and the mounting hardware manufacturers' data, which are available upon request. Panel support connections shall be staggered to distribute Icad to adjacent members. Modules in Landscape Modules in Portrait Roof Zone Interior Ed e_ Corner Interior Ede Corner Max vertical S acin in 40 40 _ 40 66 66 66 Max Horizontal acin in 64 64 _ 64 48 48 48 Max U lift Load lbs 159 131 125 268 221 210 E.Summary Based on the above evaluation,with the structural upgrade installed as prescribed and appropriate panel anchors being utilized, the roof system designed on will adequately support the additional loading imposed by the solar panels, it installed correctly.This evaluation is in conformance with the 2015 International Residential Code with Massachusetts Amendments,current industry standards and practice, and the information supplied to us at the time Of this report. It there are any questions regarding the above,or if more information is required, please contact me. 144j OF Regards, � N P G i Jon P.Ward, BE, PE A8 MA License No. 52584 : NO 52 4q r ay�9FClaTE �4�:PS3/AN , AL ENG A �rrrr rq%� 04/18/2018 ivint. NOTES (E) ROOFING (E) SHEATHING (E)- EXISTING (E) RAFTER INT- INTERIOR NI- NEW (N) 2x4 TOP PLATE NAILED -- -- — ---- - ---------J TO RAFTER WITH (2) 16d SINKERS EA. RAFTER (N) 2x4 BOTTOM PLATE (N) KNEE WALL STUD @ NAILED TO CEILING JOIST 16" O.C. 6'-0" MAX. STUD OF•,•� WITH (2) 16d SINKERS EA. LENGTH ATTACH TO TOP ` sc JOIST AND BOTTOM PLATES N P WITH (2) 16d SINKERS. AN 4y� NO. 525 y�9FC/STE68 R������P� (E) INT. WALL - i (E) CEILING JOIST rCrr/ON A������ 12' vivint Sour 1 HOME UPGRADE STRUCTURAL DETAIL KNEE WALL [IA.TE ERSION 31 : fli6lie - SK WN BY. MU PV STkING(SI'. --- 6FSECTIONS SYSTEM LEGEND 1 764 RYAN RD FLORENCE,MA 01062 ® ' SLOPE " -- v1l le moouLEs nzUHNIAL T (W SYSTEM SIZE FRONT OFHOUSE ® INGLE cGMP INEw ]e55.Ec 114.11 x]I IB MCOUIES j(IIHGLE V3 FIORE." MxrExrzsnaa onEo WIS MCOULES PIM.IUiN-]]] OMEN RR MAIEPIUCOMG. SHINGLE ® W Ili M R LJN KEEN MowLEs. EePaEGNmEo ''.. UNTEENL ¢NEw+wnr✓xEG.uimauN+Eo Ow.E,uN I I I I I i ❑D o -- O I I vivint.Solar 1 1e714G,4II9 — r SCARBOROUGH RESIDENCEQ TI ON1 N xo IYACE.,-5v5Bd5EW J SITE HNW SCALE 311 W Pv 1.01 _ - ---- � � w MOUNTING LEGEND i TP /\ SFM-TRIMRAIL WRH / �SFM-ROOF ATTACHMENT o SFM�RIMRAIL o' GOOF ATiy CHMENT o^' S A NFAIL•Eo6P �SFM-9"ATTACHED SPLICE '' �� 1111111 �•, A I l ;' s $PMµ9"SPLICE , o ,MODULES IN PoRTRAR/IANOSPACF ...•....m.�,.•............. pFMo.LA.Y00T ..4P. vivint.Solar r SCARBOROUGH RESIDENCE 76A�RD FLORENCE NIM 0 EEY2 /� ` it CO Xik. $ECIION VIEW / _ �W SYSFEM MOUNTING DETAIL �0 of w.Zovn� MOUNT DETAILS SCALE'.NOT TO SCALE -._—__— —____— _. �"' " °X mnlral[Sysrem Cond,"-tl.p.IkM lie ALLCONDUCTO.SMVSTBECOPPEg� DC Syste pSze(Watts) 13065 iagb Oesmp(on re Gauee ConEutlorr/Colpr vit5lze AC System Erza�Watts 130W 1PVWIre 1DAW6 I(WaR N/A3ree Ab N/ASree Alr r Total Motlule C...t ]BareCopperGrountl(EGC/ IC) 6AWG 10ABE N/A Eree Alr N'A Ab e 3TXWN-3 1DAWG 63W,3VQ 0A EMT 3TXWN 2-EGC/GEC BAW6 TVN) EMT 3A Q E 3THWN-16AWG 3I1.31L31NI ow. EMi 3/4" m� u 3 TXWN-}GEC I.A.G IIGBN i 3 d � e souareo pu3lExB, Polnmtln nKE'olns pplysme t £ 8 elXs aas e6mE .we opvrypAun(mm. xps ; M Xap.0 mmn n v t x nnm u mopu¢5 - ealem w/oPT mZfnS enom `'e°areooxxixxa .. iaov/wnfrrm,xsta x 1 mIM�z apw[xs. sNEEr NAME r Maas ul.ree..a. 3 3 3 sNEET vunOSp ¢Im un mum G[Cr rce NVMBEW. `" — r Aw4 mpcer nPvrnooVus Pfa uA4eRP=tneaswem • -_�. ie'emrPK.. srz p¢mnnmr K oirmnnrc4 nslµtol Tap DC s. swnmh POM.tlme Batm sae Conductor Calculations ga[etl for max operating con Eilion o/ MOE tele Make/Motlel Al 5olar1gM39Snl-60B V/Ire gauge calculated from code art.310.1501j16j with amble..temperature ca l[ulatloni lydn " e ve ee Art.690.35compBant Opens all Max Power Poini Current lem) 9.1 Am s r1.330151B)(aj(a). ungrion encomtlucmre Max.Power PO If nl Voltage jVmp) 31< Volts For OnPm/"cmEuc[ws we use Use 9OYcd umn arryatlry,Me relevant amAien[rempe temperature s s ~ Open Circuit solM E(Vo[) 39] Vol[s edusterem,and raceway 011 wouuffents from 310.1SIBj(16). a £ v ar Op[im 1[er Solar ftl eP3l0 Snotl-Lira i[Cu tram jli[j 9.61 Ams Far Off Bmf coM.[tors we use lM]SY[d column,ampaciN.or the 90'C columnamWdry with w e On Input Power 330 plains Max.SidRs Fuse lMPO) ]0 Amps the lNevant an .amtempersurtand raceway fill affuntmem ,Ani"Inver l s less. `a $ i a So OC Max.Input Voltage <g Volis m.Max.Power a[STC pri 395 Watts The ratting of the«ntlucb aNer adjustments MUST he greater than,Or egwl or the rnMin...s 9 it OC Max.Input Current 13 11 Amps Max.System voltage ICP(VDC f ULAOCI duty upra@J diameter cunent OC Max.Output Current 11 Adopt oc Tem a ed Coefficient Ol9 %/C Calculyour Example Wirt Rating(WC)I Ambien Temperature Amusement x Contluit Ei 11 Max.strip rating inverter Cepen tlent See SE tloa mens. V rated fdlurtmeat-Continuous Oury Output Curren Inverter Make/Mobel AC Output Current AcmrJm m arrej0jfl) 0].5 Ampa (On Boot.Tag l 10 gauge wire rated for G00. <O AaO96x08 j6 ConEu[[ms)=30JE A>= It Entrench m[",IE%IOW Nomin al AC VoltaBert_6 as. Volts IB]SA AC Operating Voltage a<O Voltl AU THIS PANEL I$FED BY MULTIPLE50UBCE5(UTILITY AND SOUR) 1DN Pw(iag 31:6 gauge wire rateG for 650. Cali ax.OWputarrem ALS Amps OCMM.mete(a„em Sas Am of Imor"M shch msmoduses I......In reNSO compliancewhn an. Spon Grtu It Lump[ aB Amps 69D8,Tables 110 ISM)a)(aL 310.15)B 3 e).310.1518)13)rJ. Max.Odious Faup Current <B ms 310.15(B 16.Ch apter 9Ta rale<,5,&4 Lmam"pheclh, empemrvrenmamaafmm ASHBAEa0L3mtatamesifi . AgheassrL3- a overt Mdin[hrya%Ulea Design Temp.:3a.]°c lowest Mln.Mean Extreme O0:-x59 C r Int J OCPD Calculations Breakers sized according no mm......dry-tints—em Pv n«un man dol rnrmnt b—d diN inverter rondnudi.e didirdm .m.tx 0.sslarL 00eM11). al 1SEI 1AOMUS Mae c.tpm-0].5 A x 125[,It 008(AN jF =5930 A<6DA CCPD) ey system ourpul current w/ onfin-5 duty-59 39 1 fire l5ysrem OL'PD w $ ad quer Notes la i •Oesig netl a[[ortll ng m,a,ita 11 rWe chat no are relevant to.the NEC 3017. SX EEi Allimenor ncewa ys ca Ming OC[.pent=11Ed metallic, NAME: S n 2 u SNEEi NU MBEfl: J vivint•Solar Residential Solar Power Purchase Agreement Customer Name III Contact Information: Installation Location: Nama(a), Henry Scarborough Address: 764 RYAN RD FLORENCE MA 01062 Email: ohenry01062@aol.com Approx.Installation Start and Completion Date: 2018-10-07 Primary Phone: 4135888641 Account No.: 5889340 Date of Customer Signature: 2018-04-10 $0 $ 0.193 2Oyr 2 . 9 % Up-Front Coat Energy Price($/kWh) Initial Term Escalator-Per Year Our Promises • We will design,install,operate and maintain a solar energy system on your home(the"system"). • We warranty all of our work,and that our roof penetrations will be watertight,for 20 years. • We will fix or pay for any damage we may cause to your Property or belongings. • We will not place a lien on your Property,but will record a notice of our ownership of the System. • You will not be responsible for any personal property taxes assessed on the System. • The Energy Price includes a$5 monthly discount for paying by automatic debit from your bank account. • If you need to make Property repairs,we will remove and reinstall the System if you pay our estimated costs. At the End of Your Initial Term If You Move • You can renew the Agreement for a subsequent term; • You can transfer the Agreement to the new homeowner, • You can purchase the System;or regardless of credit rating; • You can request that we remove the System at no • You can prepay the Agreement; additional cost. • After the sixth anniversary,you can purchase the System;or • You can relocate the System under certain circumstances. Your Commitment • Pay us for all the power the System produces for 20 years. • Keep your roof in good condition throughout the Initial Term. • Respond to our sales and support teams when scheduling work and completing paperwork. • Maintain a broadband internet connection. • Continue service with your utility for any energy used beyond the System's production. You may cancel this Agreement any time prior to commencement of any work at or near your Property associated with installation of the System. Vivint Solar Developer, LLC (EIN: 80-0756438) is a licensed contractor in each state in which we operate, including Massachusetts,Contractor License Nos-HIC-170848 and EC,13141A. For more information about our contractor licenses please visit www.vivintsolar.com/licanses. WE MAY HAVE PRESCREENED YOUR CREDIT. PRESCREENING OF CREDIT DOES NOT IMPACT YOUR CREDIT SCORE. YOU CAN CHOOSE TO STOP RECEIVING"PRESCREENED"OFFERS OF CREDIT FROM US AND OTHER COMPANIES BY CALLING TOLL-FREE 888.567.8688. SEE PRESCREEN & OPT-OUT NOTICE BELOW IN SECTION 25 OF THE GENERAL PROVISIONS FOR MORE INFORMATION ABOUT PRESCREENED OFFERS. The Notice of Cancellation may be sent to this address: help@vivintsolar.com I vivintsolar.com 1800 W Ashton Blvd., Lehi, UT 84043 ATTN: Processing Department phone 877.404.4129 1 Fax 801.765.5758 Copyright© 2018 Vivint Solar Developer, LLC. All Rights Reserved. PPA(3/2018,v4.0.1) I Page 1 of 16 SIGNATURE PAGE AND NOTICE TO CUSTOMERS A. LIST OF DOCUMENTS TO BE INCORPORATED INTO THE CONTRACT. These documents are incorporated as part of this Agreement and apply to the relationship between you and us: (1) Residential Solar Power Purchase Agreement, (2)General Provisions, (3) Customer Packet; and (4) Change Orders, as applicable. B. WE HAVE NOTGUARANTEED,PROMISED OR OTHERWISE REPRESENTEDANY REDUCTION IN ELECTRICITY COSTS IN RELATION TO THE SYSTEM THAT WILL BE INSTALLED ON YOUR PROPERTY. C. IT IS NOT LEGAL FOR US TO ENTER YOUR PREMISE.. UNLAWFULLY OR COMMIT ANY BREACH OF THE PEACE TO REMOVE GOODS INSTALLED UNDER THIS ACRE[MENT. D. IF YOU DO NOT ELECT ANY OF THE END-OF-TERM OPTIONS SET FORTH IN SECTION 2 OF THE PPA THIS AGREEMENT WILL AUTOMATICALLY RENEW ON A YEAR-TO-YEAR BASIS. CONSULT SECTION 2 OF THE PPA FOR MORE INFORMATION. E. YOU RISK THE LOSS OF ANY PAYMENTS MADE TD A SALES REPRESENTATIVE. F. DO NOT SIGN THIS AGREEMENT IF THIS AGREEMENT CONTAINS ANY BLANK SPACES. You are entitled to a completely filled in copy of this Agreement,signed by both you and us, before any work may be started. G. YOU, THE CUSTOMER, MAY CANCEL THIS TRANSACTION AT ANY TIME PRIOR TO MIDNIGHT OF THE THIRD BUSINESS DAYAFTER THE TRANSACTION DATE OR,IF LATER,UNTILTHE STARTOF ANY WORKATOR NEARYOUR PROPERTY ASSOCIATED WITH INSTALLATION OF THE SYSTEM. SEE THE ATTACHED NOTICE OF CANCELLATION FOR AN EXPLANATION OF THIS RIGHT. PEYRESENEATIVE: �J?/� CVSfOMERISI: � �+�d Chet u e105098 zroIRmrr Pnnred Name: 5olapenon Na. pmrted Npmr Henry Scarborough Owe. 2018-04-10 2018-04-10 Dp e FOROFFILEUSEONLY TH6 AGREEMENT 6 NDT EIWEO NOR BINDING UPONVMNTS0URMEL0PER,000NrILSIGNED5YAN Spmturr AUTNOAIMDREPRESENTATIVE. VNIM591M DEVELOPER,LLC C� OnrteC Namr S,pnutwe Op-r 2018-04-10 P.mted Npmr Syveah Ballantyne DoN 2018-04-11 prpressmp Na