Loading...
32A-154 (5)ARCHITECT J E F F R E Y S C 0 T T P E N N 77 Worthington Road, Huntington, NIA 01050 tel. 413-667-5230 fax.413-667-3082 J.psed'd � erizon, net 19 September 2017 3 ZA - IS `4 Investigation and Evaluation Familiars Coffee & Tea 6 Strong Avenue Northampton, MA 01060 General a permit has been issued for Structural remediation at the site. This document outlines pertinent portions of the relevant building codes for occupancy. IEBC 2009 Chapter 3 Prescriptive Compliance Method 310.6 Exception 2 — Accessible means of egress are not required 310.8.1 Entrances — Main Entry shall comply 310.8. 11 Toilet rooms — shall comply 310.8.14 thresholds — maximum 3/4" high 310.9.1 Site arrival points — at least one Accessible Route from Site Arrival Point — shall comply 310.9.3 At least one Main entrance shall be accessible — shall comply 310.9.4 Toilet and Bathing Facility — shall comply 521 CMR 7.3 Aisles min. 36" clear — shall comply 17.2 Seating — 5% min. 1 — shall comply 17.2.2 36" accessible aisle — shall comply 17.2.3 clear floor area for seating 30"x48" — shall comply 17.2.5 height of table or counter max. 34" high — shall comply 17.6.2 tray slides max. 34" high — shall comply 17.7 tableware and condiment areas max. reach height 54" at l.0" from face — shall comply 17.10 cash register counder max. 36" high — shall comply 20 Accessible Route — shall comply 22 Walkways (48" width) — shall comply 26 doors and doorways — shall comply 30 toilet rooms — shall. comply IBC 2009 303.1 A-2 Restaurant use group 602.3 Type I1IB construction — metal exterior but wood backers; call: Construction. Type VB Table 602 separation = 5-10 feet; Group A 1hr fire protect exterior; separation 10-30 feet Group A Ohr fire protect ext. 903.2.1.2 Group A-2 Sprinklers required if: 1. over 5000 sq. ft. fire area or 2. 100 or more occupant load or 3. public occupancy on other than grade egress level 1011.1 Exit signage visible from along accessible path 1011.5.3 Battery Backup required for Exit signage and Emergency Egress path lighting 1008.1.10 Panic Hardware required in Group A if 50 or more occupants Table 1015.1 Spaces with 1 exit or exit access doorway Group A49 max. occupants Table 1021.1 Stories with 1. exit 1St fl. Group A 49 max. occupants; 75' max. travel 248 CMR 10-10 Table 1 Restaurant A-3 (A-2?) facility requirements: Female toilets 1/30, male 1/60, lavatories 1/200 — at 49 occupants will have 25 female, 25 male thus comply with two lavatories : I i ;°�I �t - -- ---------- i NIS CA I 1: 7�1 _-7-T 7F 4 •r • 07 I _T_ X A% __t T • 1- _T I 48f 1 v YAM -rtT ZI ON A wmm� A r J r o l :p �-�o "o-dom t- -1 =I- mo OW 40- ow F '4j 100 00 +-\ , A L ,?7 �n � -- ��wti� 1 hl 11 r9whimmoo'l Z�v w4w --LDM I .. �.t ,4?0t le