Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
49-001 (3)
. M9 -oo ( i. N -- 0 I.1If.M VENTS) ❑ NOWVENTIS) m I 1 N g 4 T M 1tLUUIt O N 229 Glendale Rd, Florence MA 01062 I L_l-] �C f§2 vpi* PV SYSTEM SIZE. 0 CHIMNEY N C• 5.320 kW DC I I 8"LL z 1 I I-1 tRTIM.NI 5 j•V,( AIA9e0Me0s MODULE*,al IN j•tlronfP000( ONT/IE 9lGR Di EACJI 115— j , ST � 19M(MMI rS SS Of 1'WI OONOUI1 FROM AI1:110N BOM TO ELECTRICAL RAMI CI I 0 wOCII INTERCONNECTION rover.wvealea, A IOCMABIE DISCONNECT I TI I U II N/I MO LOCA DON.III:INTO y SIL 0 I I i) y USING ON NI IND TACNEOTOMMr 1 j •/ j v / / ■ I C o U51•ti MUONIIN{i1ACHNDTt ID KELP % / / / 7 / / JUNCTION 00110EIO VV h %%�%%� % � •� Roof Type:Comp.Shingle % %% 4 I •> ' Roof Section 1 I �l — I O Ro, Roos TM»R.M 29 115 t 7 0 I A 3 4 , Li P SHEET NAME: I---------------------------------------------------------------I ujg Na SHFFT NUMBER O PV SYSTEM SITE PLAN SCALE:3/3Y=i•-0- > _-_ a ‘...1. �'7 filwrl itcW/A„;cnfw ,KT W r[n wn...van ,,, s5.,'',..;.' ��i% .�W*�� �... Ny y. ,� ` I -- ,,\ 414 O o '," ...,... , tSitttto .4.,,,,;0 fir 01. R 7.--.' g--- -N.."'".1111111111111.11111iii 8:may. til LL _ s. s Mom MI/LIL 4Ufm PHUFILE SFM -TRIMRAIL WITH 1 SFM -ROOF ATTACHMENT z SFM-3"RAIL 3 SFM-9"ATTACHED SPLICE 4 SFM-9"SPLICE 8SFM-TRIMRAIL 6 ROOF ATTACHMENT PV 3.0 NOT ID scam Pv 3.0 NOT TO SCALE w 3.0 NOT TO SCALE w 3.0 NOT TO SCALE NOT ID SCALE pV 3.0 NOT TO SCALE L_ t13 NODULE\ . CAMT,.EVER uS OR LESS 0 ' L MAS 54 _ 1 P y,;^ colmuNc LA, \\ _ c , .iii _.____MOM,F •NMI t4 E dih W' �� x d----'.Ar-fT SFM 9'Al IACALU SIMA:L •rIMO r. > 0 ASEMB•SPI ICE . SFM 3' • ' SECTION VIEW 8 PV SYSTEM MOUNTING DETAIL i y� 3.0 NOT TO SCALE w 3.0 MDI IO SLAIt I i.I a]� C3 CLAMP.ATTACHMENT I ...-'*4 h F CLAMP•ATTACHMENT /r LOURING �I ! tk i 11 1. PERMITTED / ,♦ ri Iii- 1 COUPLING� I I CLAMP SPACING r � y4 `\\ ' �IHIMHAIL SPLICE \ THOMAS.ROOF ATTACHMENT SEE TAME ll IA(IUtlllIll I (DI iiii Ili SHEET RAFTER NAML: utuvaA J _ _Q 111111111 MODULE 1111 RAFTER 0 ILL SHEET 1-1 ANDSCAPT CA AMP SPACING NUMBER: 9 MODULES IN PORTRAIT/LANDSCAPEL-PORTRNT 10 SFM LAYOUT CV w D 3 NUT TO SIDLE I_ —.I CLAMP SPACNG . 3.0 NOT TO SCALE Q- . Photovoltaic System Conduit Conductor Schedule(All CONDUCTORS MUST BE COPPER) DC System Size(Watts) 5320 Tag it Description Wire Gauge N of Conductors/Color Conduit Type Conduit Size m AC System Size(Watts) 3800 1 PV Wire 10 AWG 2(V.,V-) N/A-Free Air N/A-Free Air •-•., m Total Module Count 19 1 Bare Copper Ground(EGC/GEC) 5 AWG 1 BARE N/A-Free Air N/A-Free Air 11 s o N 2 THWN 2 10 AWG 2(1V1,1V-)B/R EMT 3/4" o -i ct 2 THWN-2-Ground 8AWG 1(GRN) EMT 3/4" a i 2 3THWN•2 10AWG 3(111 112 1N)B/R/W EMT 3/4" C � i ro' 3 TIIWN•2•Ground 8AWG 1(GRN) EMI 3/4" t m ;. 8Ns4 u Jr 0 i- (/1 4- C • n n. o e n.y Y N Y V of re Q • n Solar Edge R so m 51310011./5 0 `� ii 'Conforms to ANSI m C12.1-1008,Rapid Z a2 o_ shutdown disconnect Is DC Point of Interconnection.IOAA � 7 Aswitch. Rapid Shutdown Side 705.12(0)(3HD) Z Disconnect.Square I) u, icicc 2 OU221RB 240V/30A '' IL . Unfused,NFMA1.or ���>n v. .71' io equivalent,with 25Y a in terminations SHEET L ■■ NAME: eie ILII r i• a fan,: }IDV/1)1A C t° ? _I _ ______ Servl ce Pand,5.n�ie C 'C STRING 1:19 PV t �� �� ■ • i �.-_ 3- Phes Oi�Ymw�cA Mani MODULES ■ II NEMA4 Iunsdon Sun " O II with Irreversible © © SHEET Ground Splice(TTPI i L; 1 A NUMtlER 1910 MODULES PER INVERTER-5320 WATTS Visible lockable Knife'NC Minimum GEC size 6 e'i STC Disconnect Awl topper DC Safety Switch PV Module Rating @ STC Conductor Calculations co Rated for max operating condition of Module Make/Model 1KM280M-608 §. Inverter.Art.690.35 compliant.Opens all Max.Power-PoInt Current(Imp) 8.81 Amps -Wire gauge calculated from art.code 310.15(8)(16)with ambient temperature calculations from v z o art.310.15)2))a). ungrounded conductors Max.Power-Point Voltage(Vmp) 31.8 Volts ra o w ¢ m For "On Rool'conductors we use the 90°C column ampacity,0.5"-3.5"off-the-roof temperature a M Open-Circuit Voltage(Voc) 38.6 _ Volts adjustment from 310.15(B)(3)(c),and raceway fill adjustments from 310.15(8)(16). z O timirer Solar Edge P300 Short-Circuit Current Ise 9.53 Amps c iu u c N ( IFor"Ott Roof"conductors we use the/S'C column ampacity,or the 90'C column ampacity with „ w 'o DC Input Power 300 Watts Max.Series Fuse(OCPD) 15 Amps the relevant ambient temperature and raceway fill adjustments,whichever is less. E r DC Max.Input Voltage 48 Volts Nom.Max.Power at STC(Pmax) 280 Watts The rating of the conductor after adjustments MUST be greater than,or equal to,the continuous t• r°° O a . _ LL i DC_Max.Input Current 12.5 Amps Max.System Voltage 1000 V DC(UL) duty uprated output current. DC Max.Output Current 15 Amps Voc Temperature Coefficient _ -0.29 J %/C Calculation Example-Wire Rating(90"C)x Ambient Temperature Adjustment a Conduit Fill =t Max.string rating inverter dependent.See SE documents. Adjustment s=Continuous Duty Output Current Inverter Make/Model - SF3R0OH-US AC Output Current According to art.690.8(8)(1) 15.83 Amps (On Roof,Tag 2):10 gauge wire rated for 40 A, 40 A x 0.71 x 1(2 Conductors)=28.4 A>=18.75 CEC Efficiency 99 % Nominal AC Voltage 240 Volts A (Off Roof,Tag 3):10 gauge wire rated for 35 A, 35 A>=19.79 A AC Operating Voltage 240 Volts THIS PANEL IS FED BY MULTIPLE SOURCES(UTILITY AND SOLAR) Cont.Max.Output Current 16 Amps DC Mao.Input Current 10.5 Amps Rooftop conductor ampacities designed in compliance with art. Short Circuit Current17.5 Amps 690.8,Tables 310.15(B)(2)(a),310.15(B)(3)(a),310.15(B)(3)(c), Max.Output Fault Current 1/.5 A/20 ms 310.15(B))16),Chapter 9 Table 4,5,&9. Loacation specific f� - - temperature obtained from ASHRAE 2013 data tables. ASHRAE 2013- • �' Highest Monthly 2%U.B.Design Temp.:33.2°C Lowest Min.Mean Extreme D.B.:-26.9°C U d N d V us I OCPD Calculations 0 Breakers sued according to continuous duty output current.PV circuit nominal current based off re inverter continuous output current X(1.25jart.210.19(A)(1)(a))). 40 u, id Inverter 1:513800H-U5 Max Output-15.83 A x 1.15(art.210.19(A)(1)(a)) • n- -19.79 A<70 A(OCPD) 7 system output current w/continuous duty=19.79<20A(System OCPD) a cc ,, z J co J V Q Q M N vl Lo Q O Other Notes I E '^ •Designed according to,and all code citations are relevant to,the NEC 2017. SHEET •All ampacity calculations are made In compliance with art.220.5(6)..49 and below Is rounded down to 0,and.50 and above are rounded NAME: up. •All interior raceways carrying DC current shall be metallic. d De0 0 z 0. SULU NUMBER: N W