31A-169 (11) 66 MAYNARD RD SM-2017-0061 COMMONWEALTH OF MASSACHUSETTS CITY OF NORTHAMPTON jCIS#: 5778 ,Sse":4.,,o, Map. 31A _ -- Block: , SHEETMETAL PERMIT ot- 1001 Permit: SHEETMETAL Category: ISHEETMETAL Permit# SM-2017-006i PERMISSION IS HEREBY GRANTED TO: Project IS-2017-001763 Est. Cost: $17,500.00 'Contractor: License: Expires: Fee Charged$25.00 ROCK VALLEY HVAC Sheetmetal-2626 04/28/2016 Balance Due:$.00 Owner: MARTIN ROBERT lk of Fixtures: Applicant: ROCK VALLEY HVAC DigSafe# AT: 66 MAYNARD RD UsoGroup ConstClass ISSUED ON: 07-Jun-2017 AMENDED ON: EXPIRES ON: TO PERFORM THE FOLLOWING WORK: provide heat pump systems for new addition and existing 2nd floor bedrooms_Ductwork to be sealed to energy star standards and insulated with R-6 insulation THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Signature; Fee Type: Receipt No: Date Paid: Check No: Amount: Sheetmetal RLe 2017-006645 974urH 7 1323 329.00 212 Main Street,Phone:(413)587-1240,Fax:(413)587-1272,Email:Ihashrouck@narthamptonma.gov GeoIMS®2017 Des Leuriers Municipal Solutiaoe.lac File#SM-2017-0061 APPLICANT/CONTACT PERSON ROCK VALLEY HVAC ADDRESS/PHONE 7 APPLEWOOD LN (413)535-7804 PROPERTY LOCATION 66 MAYNARD RD MAP 31A PARCEL 169 001 ZONE U RB(I00U THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid C3\19 Building Permit Filled outFee Paid Typeof Construction: provide heat pun systnew addition and existing 2nd floor bedrooms. Ductwork to be sealed to energy star standards and insu aced with R-6 insulation New Construction Non Structural interior renovations Ad.ition to Existin Accessory Structure Building plans Included: Owner/Statement or License 2626 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INFOliMATION PRESENTED: u/Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER : §_ Intermediate Project: Site Plan AND/OR Special Permit with Site Plan Major Project: Site Plan AND/OR Special Permit with Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received&Recorded at Registry of Deeds Proof Enclosed _ Other Permits Required: _Curb Cut.from DPW Water Availability _ Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee P•gnitftp, Street Co issirtr Permit DPW Storm Water Management 74 Signature o'Bu ling Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact the Office of Planning&Development for more information Commonwealth of Massachusetts CIC / 3 A26 r r1= City Of Northampton t1 , ac Da e: 6/5/2017 Sheet Metal Permit Permitlift spn-j7_w J E$timated Job Cost: $17,500.00 Permit Fee: $ 2 S Plans Submitted: YES NO Plans Reviewed: YES NO ��--Business License# SM2626 Applicant License# Business Information: Property Owner/Job Location Information: Name: Rock Valley HVAC Inc. Name: Robert Martin Street: P.O. Box 1162 Street: 66 Maynard Rd. City/Town: Easthampton City/Town: Northampton Telephone: (413) 535-7804 Telephone: (315)735-6308 Photo ED. required/Copy of Photo I.D. attached: YES . NO Staff Initial J-1 /M-1-unrestricted license J-2/M-2-restricted to dwelling -stories or less and commercial up to 10,000 sq. ft. /2-stories or less Residential: 1-2 family Multi-family Condo/Townhouses Other Commercial: Office Retail Industrial Educational Institutional Other �7 Square Footage: under 10,000 sq. ft. " over 10,000 sq.ft. Number of Stories:_ o� Sheet metal work to be completed: New Work: >/ Renovation: ✓to/ HVAC ✓ Metal Watershed Roofing Kitchen Exhaust System ✓ Metal Chimney/Vents Air Balancing Provide detailed description of work to be done: Provide heat pump systems for new addition and exiling 2nd floor bedrooms. Ductwork to be sealed to energy star standards and insulated with R-6 insulation, (R-8 in attic). Fees with Building Permit:$25.00 Residential,$50.00 Commercial. Fees for jobs without a Building Permit$6.00 per$1000 Minimum fees for jobs without Building Permit$50.00 Residential,$100.00 Commercial INSURANCE COVERAGE: I have a current gabigly insurance policy or its equivalent which meets the requirements of M.G.L.Ch. 112 Yes lid'No LJ If you have checked Yes, indicate the a of coverage by checking the appropriate box below: A liability insurance policy Other type of indemnity ❑ Bond ❑ OWNER'S INSURANCE WAIVER: I am aware that the licensee doss not hays the insurance coverage required by Chapter 112 of the Massachusetts General Laws,and that my signature on this permit application stablesthis requirement. Check 0 ly Owner Agent ❑ Signature,of OwnerOor Owner's Agent By checking this boxy Thereby certify that all of the details and information I have submitted(or entered)regarding this application are true and accurate to the best of my knowledge and that all sheet metal work and installations performed under the permit issued for this application will be in compliance with all pertinent provision of the Massachusetts Building Code and Chapter 112 of the General Laws. Duct inspection required prior to insulation installation: YES NO prngreee IneperHnnc Date f nmmentc Final Invert-inn note (nmmenrs Type of License: By LJ Master Tine ❑Master-Restricted City/Town ❑Joumeyperson Signature of Licensee Permit# DJourneyperson-Restricted License Number: �. C- Fee$ ❑ Check at www mace gnvidpi Inspector Signature of Permit Approval A N ,y„r Level 1 � > > Pf\ : k Rs�L, SEz- rc, NA duAj a kcktac A ; na\oc)r tc_vv 1-c) Garage (1* -J-_3cL.6k i1/4[\" a - C36 Na4z- a1/4J c o Jv . Hall 2 M m PWD 9 4 I STR Kitchen Sun room Living Room Dining Room Hall / I Job #: Rock Valley HVAC Inc. Scale: 1 : 88 Performed by Wes Fortier for: Page 2 Robert Martin P.O.Box 1162 Right-Suite®Universal 2017 66 Maynard Rd. Easthampton, Ma 01027 17.0.21 OS 13.451 Northampton, 3 Ma 01060 Phone: (413) 535-7804 2017-Jun-05 66.4 Maynard Phone:(315)7356308 ve\Heat Loads(11 66 Maynammp www.rockvalleyhvaccom Rockvalleyhvac@yahoo... __ �a) f ', 1s�h i SES K O c9 WA " � kuc. cur koxck -er — Level 2 Master Be. U A clos 2 Ban1 Hall 4ith lar R J]dr1111y or t : illeal Bath 1 4 Hall 3 i 1� II Clos 11lI � I il Job#: Rock Valley HVAC Inc. Scale: 1 :88 Performed by Wes Fortier for: page 1 Robert Martin PO Box 1162 !dant-Suite Universal 2017 66 Maynard Rd. Easthampton,Ma 01027 170.21 RS1124596 017-den-og 13 45 13 Northampton, Ma 01060 Phone:(413)535-7804 vevieat Loads(1)66 Maynard rup Phone: (315)7356308 www.rockvalleyhvac.com Rockvalleyhvac@yahoo... wrightsoft Project Summary Date: June 5,2017 Entire House By: Wes Fortier Rock Valley HVAC Inc. P.O.Box 1162,Easthampton,Ma 01027 Phone:(413)535-7804 Email.Rockvaleyhvaceyahoo.com Web:wwwrockvalleyhvac.corn License: SM2626 Project Information For: Robert Martin 66 Maynard Rd., Northampton, Ma 01060 Phone: (315) 735-6308 Notes: Desi. n Information Weather: Chicopee Falls/West, MA, US Winter Design Conditions Summer Design Conditions Outside db 5 °F Outside db 88 °F Inside db 70 °F Inside db 72 T Design TD 65 °F Design TD 16 °F Daily range M Relative humidity 50 Moisture difference 28 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 44383 Btuh Structure 20376 Btuh Ducts 0 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 44383 Btuh Use manufacturer's data n Rate/swing multiplier 0.93 Infiltration Equipmenf sensible load 18950 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi-tight Fireplaces 1 (Semi-tight) Structure 1030 Btuh Ducts 0 Btuh Central vent(0 cfm) 0 Btuh Heating Cooling (none) Area (ft2)) 2610 2610 Equipment latent load 1030 Btuh Volume(ft') 21445 21445 Air changes/hour 0.32 0.15 Equipment total load 19979 Btuh Equiv.AVF(cfm) 113 54 Req. total capacity at 0.70 SHR 2.3 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trade Trade Model Gond AHRI ref Coil AHRI ref Efficiency 80AFUE Efficiency 0 SEER Heating input 0 Btuh Sensible cooling 0 Btuh Heating output 0 Btuh Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 1099 cfm Actual air flow 1099 cfm Air flow factor 0.025 cfm/Btuh Air flow factor 0.054 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.95 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri htsoft^ 2017-Jun-OS 13:44:47 Gy 9 RghiSatl�Universal 2017 17.0.21 R5024598 Page 1 MM _.wnMGcogle Dnve\Heat Leads(1)\66 Maynard.mp Calc=MJB Front Door faces N