Loading...
22B-054 taLe e ((Litt of Northampton ` I. _?ea RiassadlusstteB5Y niattry DEPARTMENT OF BUILDING INSPECTIONS —1 I INSPECTOR 212 Main Street • Municipal Building Northampton,MA 01060 CERTIFICATE of OCCUPANCY and USE This is to certify that permission is hereby granted under 780 CMI?, sixth edition of the Massachusetts State Building Code, allowing the occupancy or use of the premises or structure or part thereof located at 24 Spring.Street as shown on the Assessors Pa t' ` 5li ^x :.1 -.'.sIZone Gi/wsP/wt' in the City of Northampton, as erein specified CONSTRUCTION TYPE(780CMR 6) 2C USE GROW CLASSIFICATION (780 CMR 3 F1 OCCUPANT LOAD PER FLOOR (780 CMR Table 1008 I 2 1 per 100 sq ft LIVE LOAD PER FLOOR (780 CMR Table 1606.1) 125 lbs/per sq ft Under the following limitations, special stipulations, and /or conditions of the permits. Light Manufacturing Issued this 18th day of December 2000 Certificate of Occupancy and Use t; 1A Authorized Department Personnel Electrical Elevator Fire Plumbing Building Gas ve Building Commissioner This certificate shall be posted by the owner, in a permanent manner and in a visible location, on all floors designated as use group H, S, M, F, or B, and in every room where practicable of use group A, I, R-1, or R-2 per requirement of 780 CMR section 120.,9 Posting Structures_ D re a A 7 n' • d v -v o ttri O z - 3 o zr C 1 'C H R —1 _ F Qt TS > O m �' Z 3 3 Ln f - a m £ .,3 C a vy 4 i '//3 1 '/ Zoning Miscellaneous Additions,Repairs,Alterations,etc. Tel.No. 32(/7.cO' t Alterations NORTHAMPTON, MASS. N14-Y `L I9 @ Additions Repair `• Y�' ^ APPLICATION FOR PERMIT TO ALTER :r � P Garage 1. Location SFIZI1.4Ca .572E67, (=LOZCAItS Lot No. 2. Owner's name N 0112/) -/11Aod Ft3:517UC1S Ito Address 24 tF It4CI S"T. ).F1.-001=T.1Ce 3. Builder's name NAMPS4/LE COfl 7tAit7/on/ 4,2/4/CAddress 321 wE57 57EE 7z Nott7N /M7Fla Nk1 Mass.Construction Supervisor's License No. o 172 7-Ce Expiration Date f C'27.'1 4- 4. Addition -- 5. Alteration GONS7EUC-7 St /V tole ROOM W/7N/A/ EX/SJ,NU A/ANUFAL7✓.0A34, 13on.tF'AK.Z. 6. New Porch 7. Is existing building to be demolished? AAO S. Repair after the fire ^4/A- 9. Garage A.//A No.of cars Size 10. Method of healing 405 nee atr4RM A/2'/�_FugN4La 11. Distance to la lines -6/Z e Fp007 '7Lx� /L / 3 e .a / .457) RE42 12. Type of roof 13. Siding house ,,(. /a 14. Estimated cost-r aZ' Olt? The undersigned certifies that the above sue men are I best of his, h knowledge • d belief. _. / \,`g. 1 rJJ Signature of r sponszble app.¢ant Remarks MAY 7 1996 /) y( Pile No. 7�/�‘:-' G ZONING PERMIT APPLICATION (§10 . 2)defrorbliff5 ) PLEASE TYPE OR PRINT ALL INFORMATION ` 11 3,3 . ( 1. Name of Applicant: /UO7,L4 - iDO(7S IML- C���/ S71 Address: j4$pe/A/rt 67.0567p no Aittc Telephone: .3 77 2 a7/ ' 014- 2. Owner of Property:� A/07/LA -XIAy P/2oLYX-7S /N( r , Address: `'/1/AA(I S7 tET- Telephone: 123/5”1,9412_ 3. Status of Applicant: `Owner rContract Purchaser Lessee Other''/I (explain): `tJ 4. Job Location: F 5P/21A/0 672067 / Parcel Id: Zoning Map# da Parcel# 5 Si District(s): lY) ) WSP / hJ p (TO BE FILLED IN BY THE BUILDING DEPARTMENT) /// 5. Existing Use of Structure/Property 444N OF/W...100/A.)C, /pas 74-ousa: /3c s 447,/Lo 6. Description of Proposed Use/VVork/ProjecUOccupaton: (Use additional sheets if necessary): CON57t1/L7 sSO� Xfvo/ BOOM W/74/0V 7N6 Ey/if:WI :: 444-1I1JFaLTUEr NLi Q3Ulr.q'NU 7. Attached Plans: // Sketch Plan Site Plan Engineered/Surveyed Plans Answers to the following 2 questions may be obtained by checking with the Building Dept or Manning Department Files. 8. Has a Special PermiWariance/Finding ever been issued for/on the site? NO ✓alDON'T KNOW YES IF YES,date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO DON'T KNOW YES IF YES: enter Book Page and/or Document# 9. Does the site contain a brook, body of water or wetlands? NO DONT KNOW YES IF YES, has a permit been or need to be obtained from the Conservation Commission? - Needs to be obtained Obtained ,date issued: (FORM CONTINUES ON OTHER SIDE) 10. Do any signs exist on the property? YES ✓ NO IF YES,describe size, type and location: .. Two 5.Icud Loaefe--z2 oaf recede nax> 70 er4Z6 IreY24" Are there any proposed changes to or additions of signs intended for the property?YES Nor'"-- IF YES,describe size, type and location: 11. ALL INFORMATION MUST BE COMPLETED, or PERMIT CAN BE DENIED DUE TO LACK OF INFORMATION. anis cote® to he filled in by the Bailding Department Required Existing Proposed ( By Zoning Lot size Acizes /0, 639A g55,$/p' Frontage 155. �(a Setbacks - frnnt X17 r 312- - side L:400 R: Si L: Voo R: 30 - rear fyQ( /SO Building height r ._ Bldg Square footage gj6d7D Sr g(oOOb 5F %Open Space: -(Lot area minus bidg 7/1X0 / C! 7217 &paved parking) �I lij Pf, -Parking Spaces /010 /20 t %f Loading Docks / O /q Fill: 6 t(boltkme -& location) N/,a tJ/q . r 13 . Certification: I hereby certify that the informatit ,•(i•a 7Lit G is true and accurate to the best of my knowl-dge. VY DATE: 05OOZ—147 APPLICANT's SIGNATURE enrinirr4F NOTE: tssunnoe of a zoning permit does not relieve an applicant's burden to Qom Sty with at zoning requirements and obtain an required permits from the Board of Health. Conserv-'i. Commission. Department of Public Woro_ and other applicable permit granting authoriti '.9'„. FILE # oviumopi 1e City of Northampton REQUIRED INSPECTIONS '�s-!, 1. Footings and Walls ,.:_� �_ e BUILDING DEPARTMENT g 2. Structural Components in Place* 3. Complete Building* No. 344 Office of the Building Inspector Zoning Form No. 960926 Date 5/8/96 Fee $192.00aeekp 7634 & 7624 Page, 22B Parcel 54 ,Zone GI/WSP/WP Section 127 U Yes ® No BUILDING PERMIT * Plumbing and Electrical Inspections required THIS CERTIFIES THAT Hampshire Construction/Robert Bartlett Jr. before Building Inspections has permission to construct a 50' X 60' room inside existing building. Inspection on Site—Foundations situated on 24 Spring Street - Nutra Max Products Inc. Inspection of Plumbing—Rough provided that the person accepting this permit shall in every respect Inspection of Plumbing—Finish conform to the terms of the application on file in this office, and to the Gas Inspection provisionsof the Statutes and the Ordinances relating to the Construction, WActs }IA/ 5-/7/l Maintenance and Inspection of Buildings in the City of Northampton. Inspection of Wiring—Rough Any violation of any of the terms above noted is an immediate revocation Inspection of Wiring—Finish /1 of this permit.Expires six months from date of issuance,if not started. Building Inspection—Rough C./-1; Note:A certificate of occupancy will be issued by this office upon return Insulation Inspection of this card signed by the Plumbing,Wiring and Building Inspectors. Building Inspection—Finish Smoke Detectors(Fire Department) Other THIS CARD MUST BE DISPLAYED IN A CONSPICUOUS PLACE ON THE ' r( MI Certificate of Occupancy P Y � � - -I._- � Biu Buildi g Inspector t=aiggil FILE I n C n < V CO-( 9114 MY 7 1906 • APPLICANT/CONTACT PERSON: ;c�/7,,-/A<77,-,,,L7-_ r �,N! ;/,i�7C; r r ,// /f G<" , 7// ADDRESS/PHONE: -`T , ,•/_---,7! -11•0/4-1,4, ;Y PROPERTY LOCATION: -,21 If; (/.<7. ci • C !! '///le l MAP o'er % PARCEL: ! y ZONE r :/::cz- f rf THIS SECTION FORAFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSE]) REQUIRE]) DATE 7ONTNf_FORM FIT .FD (MIT L! Fee Paid mit Building Permit Filled`nut i- '1r/&.5/L . 40i-I _ FeePaid � A11' i. 1•i` — d ✓ Type of Cnnctnierino• New f nnctnirtinn (.c%G CLst'f/G Remodeling interior Addition to Trifling J.f _ - e!t, A rreccnry Ctnirtnre Building Plans included• I Seta n Plans l Pint Plan THE C GLOWING ACTION HAS BEEN TAKEN ON THIS APF ICATION: ? • Approved as presented/based on information presented Denied as presented: Special Permit and/or Site Plan Required under: § PLANNING BOARD ZONING BOARD Received&Recorded at Registry of Deeds Proof Enclosed Finding Required under:§ et/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed I Variance Required under. 6 w/ZONING BOARD OF APPEALS Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval-Bd of Health Well Water Potability-Bd Health Permit from Conservation Co„ i .ion Signature of Building Lisp r Date • NOTE:issuance of a zoning permit does not relieve en applioant's burden to oompiy with all zoning requirements and obtain all required permits from the Board of Health, Conservation Commission, Department of Public Works and other applioable permit granting authorities. a > 2 S 9 z C s n U c x 3' 3 c `z FX re - . ad - _ in 7 Z - > 3 3 mF e O A -I c [r1 t Zoning Miscellaneous Additions,Repairs.Alterations.etc. Tel.No. Alterations � NORTHAMPTON, MASS. 19_ Additions j APPLICATION FOR PERMIT TO ALTER Repair :.A- r� � Garage I. Location r2il 512nNg SI-- Q v' ,>l,1 . fwj Lot No. 2. Owner's name YC �. i/.- ,. 1 ,�VC�S3Pwa Ca' Address a'1 S 'r ' t r 3. Builder's name 1 Ms4 / Cd NCZ Address I).1 L'IA„./Cy Si— i Mass.Construction Supervisor's License No. ()Sect 51) Expiration Date 9'3 45 4. Addition / 5. Alteration i& -f 1 ' ' ' . .1 f 4. { i 6. New Porch 7. Is existing building to be demolished? 8. Repair after the rue 9. Garage No.of cars Size 10. Method of heating 11. Distance to lot lines 12. Type of roof 13. Siding house 14. Estimated cost- E3.0 c_____ g ;J[^3 The undersigned cert ies that the above statements are true to the best of his, her knowledge and belie . (��)� ((���) l Sage of re able app scan, •Remarks i`�*IWC le.."19W, L'Rg11 c(S (SCI CG`rn i/i< ON7 + t,J R ykd , �ptc#f e Saki l`Gl rv4 Revd nit f,,,rrd, T_f/Sktll 11,4„IJ reit C-K& 1079, 440 Date Filed ', 003182 File No. ZONING PERMIT APPLICATION (510. 2) Ali . Name of Applican - "�� �nj 'S Q�1� / )]3 Ek �'�� UMZ - e Address : ! — s�;�_- Te ephone: 2 . Owner of Property: . o0-$45 0m-4 rc,. (-45 Address : 3�lpR, S'f GTsa.f Telephone: 3 . Status of Applicant: Owner f_ Contract Purchaser _Lessee _Other (explain : 4 . Parcel Identification: ZoningpMap sheet# 22'6 , Parcel# 5T''// Zoning District(s) (include owe lays)' V _ Street Address YY'' ' , Required 5 . Exi$i �, Proposed by Zoning Use of Structure/Property �"Lp (if project is only interior,.. work, skip-to #6) Building height %Bldg. Coverage (Footprint) Setbacks - front - side L: R: L: R: - rear Lot size Frontage Floor Area Ratio %Open Space (Lot area minus building and parking) Parking Spaces Loading Signs Fill (volume & location) 6. Narrative Descrip on of Proposed Work/Project: (Use additiopa sheets if necessary) ct ---�INeMp..e- LJ: ,J Yo ' O^/ rol+ 01 it' I /Ace rev 7 . Attached Plans: Sketch Plan Site Plan 8 . Certification: I hereby certify that the inf mation contained herein is true and accurate to the best of my knowl d Date: l -fly Applicant' s Signature: ( // THIS SECTION FOR OFFICIAL USE ONLY: UUU. Approved as presented/based on information presented Den -d as presented--Reason: • -ci.1 Per 't and/or Site Plan Required: — 40 , • g Rep/Fr- 6 : Variance Required: -� vi • gnatu of-Bulldi • sector �//�'153 D e Y e) NOTE: Issuance of a "ng permit does not relieve an applicant's burden to comply with all zoning requirements and obtain all required permits horn the Dowd of Health,Conservation Commission,Department of Public Works and other applicable permit granting uuthodtles. L. y City:of Northampton REQUIRED INSPECTIONS ` �`�� 1. Footings and Walls :;= BUILDING DEPARTMENT 2. Structural Components in Place* 3. Complete Building* No. 833 Office of the Building Inspector Zoning Form No. 003182 Date8/24/94 Fee $40 Check* 1872 Page, 22B Parcel 54 ,Zone GI Section 127 U Yes ® No BUILDING PERMIT * Plumbing and Electrical Inspections required THIS CERTIFIES THAT David Nunez before Building Inspections hasmission to Remove roof & replace rafters, reshingle Inspection on Site—Foundations situated on 24 Spring Street Inspection of Plumbing—Rough provided that the person accepting this permit shall in every respect Inspection of Plumbing—Finish conform to the terms of the application on file in this office, and to the Gas Inspection provisions of the Statutes and the Ordinances relating to the Construction, Inspection of Wiring—Rough Maintenance and Inspection of Buildings in the City of Northampton. Any violation of any of the terms above noted is an immediate revocation Inspection of Wiring—Finish of this pennit.Expires six months from date of issuance,if not started. Building Inspection—Rough Note:A certificate of occupancy will be issued by this office upon return Insulation Inspection of this card signed by the Plumbing,Wiring and Building Inspectors. Building Inspection—Finish Smoke Detectors(Fire Department) Other THIS CARD MUST BE DISPLAYED IN A CONSPICUOU$PL CE Ai PREMISES Certificate of Occupancy B ' • nspector �. . r�CP '9Alf SiID9lI PERMIT APPLICATION I CHEC . ST i►11 •IG • . • .. • b... ' � I.. rry YES NODS 1 . ON . FOP . A- ION / 2 . PERMIT APPLICATION S 3 . OWNER OCCUPANT STATEMENT / LIC. # IF NOT 4 . 3 SETS OF PLANS /PLOT PLAN 5 . NEW CONSTRUCTION 6 . CURS CUT 7 . WATER AVAILABILITY FORMS 8 , REMODELING INTERIOR 9 . ADDITION 10 . ACCESSORY STRUCTURE 11 , SIGN / AWNINp 12 . PERMIT FEE - CHECK ONLY - MONEY ORDFR 13 . SPECIAL PERMIT REQUIRED WITH DEED IF APPLICABLE 14 . UNDER SECTION 127 - CMR 780 15 , FORM A 6 . FI I_ _ _ (i ,.. .' OMMENTS • �M-'^' HAMPSHIRE CONSTRUCTION CO., INC. ,G44X13 OO 7 4 - AE L JU44LQIL 327 West Street NORTH HATFIELD, MASSACHUSETTS 01066 (413) 247-5024 OATS OS O . f(' J08 eNc FAX (413) 247-3305 ATTENTION LLQ,AM7AMy -o,PA Sa7 Aurae: RE TO C/7Y c A-1007N4/4p70&/ /J0724 -A141 PZottc S itcluanVG7 / p .g7%ja-M - tV/ PE7Nv 572a'7 /=LoeoNLE, 41455 . r : MAY 819e6 WE ARE SENDING YOU. r a Attached ❑ Under separate cover via the following items: ❑ Shop drawings - -- -Prints 7 Plans�f ❑ Samples ❑ Specifications ( C. J1"Copy of letter ❑ Change order )( ff - WaSti 040 COPIES v DATE NO. DESCRIPTION OMS (aIL,NAN teos Co/iP4- lY 1oafarc47/0N ale 10,3o,q/ PAL7otY ,Gt01214t, nsE,4,e1a 2etr (614.44.4A/ &zos gate-?) THESE ARE TRANSMITTED as checked below: For approval 7 Approved as submitted 7 Resubmit copies for approval ❑ For your use 7 Approved as noted ❑ Submit copies for distribution ❑ As requested 7 Returned for corrections C Return corrected prints 7 For review and comment C ❑ FOR BIDS DUE 19 7 PRINTS RETURNED AFTER LOAN TO US REMARKS 56/0 La-. /Ol> eaJ&dire EQif7N6,t /Alzrag=At47/aAI paf&r Go T! 7 -GIC eucu5at fl ,00% C# ZA( /N 7/ Aktouu7 Or- 51--• K 7C 40 Q AS A Pts4o4-77f I .. COPY TO faE 47Z.G77 SIGNED: 7 If enclosures are not as noted,kindly noti us at o THE J GILMAN BROTHERS COMPANYMAY 8 935 GILMAN Manufacturers of Commercial Quality Foam Boards Thank you for your recent inquiry regarding Gilman Ceiling Panels. Wr arc pleased to enclose the product literature and samples you requested. What Is the secret to the Gilman Ceiling Panel technology and performance? Our panels are designed to he installed completely below either an upright or pendant sprinkler system, therefore the sprinkler heads above the panels are completely hidden out of sight. The low melt temperature parcels arc designed to quickly shrink and drop out of the grids exposing the heads and allowing the sprinkler system to activate with a 'prompt and unobstructed sprinkler waren flow'_** What makes these panels extremely desirable and popular for both nen and existing sprinkler and ceiling systems? Since the panels can be installed below the sprinkler system, rime, labor and material costs are reduced significantly by not basing to lowcr the sprinkler heads. In addition, .savings due to reduced heating and cooling coat are also realized because of the insulation value of these noels. Since fire safety and the performance of Gilman Ceiling Panels are of primnn' importance, extensive testing has been performed to meet some of the roughest standards; e National Fire Protection Association Standard 131791. • Classified by Underwriters Laboratory, Inc • Factory Mutual System Approved Standard 4651. * Meets ASTM C578-92 for thn mai insulation. " Non-dusting to meet USDA standards. Weighing less than one pound per panel. the light weight easy to install Gilman Ceiling Panels art manufactured with a bright white pebbled finish on both sides. Having two usable finished sides allow the panels to be reversed for rnyry additional years of service. Being made of 100% thermoplastic resin, the Gilman Ceiling Panels arc inherently moisture proof which makes thein washable and resistant to warp. sag and mildew. Additionally, the Gilman Ceiling Panel is the answer for the environmentally responsible companies who require a recyclable material. Installations that spec!fy our ce"hug panel msy be recycled ;MO other useful products lhwugh available polystyrene recycling facilities throughout North America. If you should have any questions concerning technical data es wet! as pricing and delivery intermiloa, please feel free in contact us at 1-800-851-4220. ely, ^ • Gray, /'/ Sales Manager V **Factory Mutual Research approval standard for plastic suspended ceiling,panels. Section 1.4 • Oilman °sad • Gilman,Comhecticut 06736 • Fox(203)899 tt226 • Telephone(203)889.8444 4h='d OTC: TNT Cu 'aces ;R.^_ Lf' 'ii , 'SPtt3 Ies11I0 3H1 old '7.:60 55, LT "CV 1 Factory Mutual Research 1161 Oostun•P,nvidence Turnpike 11 P.O. Aox 0102 MAY 81996 Norwood. Mnuchusetts 02067 OV7A9.AC Ogi:ober 30. 1991 (4651) CELLULITE SUSPENDED CEILING PANELS from THE GILMAN BROTHERS COMPANY GILMAN, CONNECTICUT 06336 1 1 INTRODUCTION 1. 1 The Gilman Brothers Company submitted their Cellulite suspended ceiling IPanels. a foamed polystyrene product. for Factory Mutual Research Approval . 7.. 2 This report contains the results or fire tests previously Conducted under report Serial No. 19052 . 1.3 Fire tests were conducted on the product to determine Its effect an the operation of automatic sprinklers installed above and its possible risme spread behavior when installed in a suspended roiling grid system. 1. 4 The suspended ceiling panels produced no Flame spread over its surface and will not significantly interfere with expected sprinkler operation. 1.5 Cellulite polystyrene ceiling panels met Factory Mutual Research Approval requirements subject to the limitations noted in Section V. 1.6 This report supersedes Report Serial No. 19052. 7 II MATERIAL TESTED 2. 1 The Cellulite suspended ceiling panel is a rigid board molded from expanded polystyrene beads, The product had an average density of 1.0 lb/ft' (16.0 kg/mil and is provided in nominal 2 x 4 ft (0.6 x 1.3 NO x 1 tn. (25 mm) thick square edge panels. 1 III FIRE TESTS 3, 1 Seven tests were performed to observe the ease of drop-out or melt-out, the cooling effect due to water application simulating sprinkler distribution and the surface combustibility of the product. 13.2 For tests 1 and 2, three panels were mounted horizontally in a metal suspension system positioned 35 in. (89 mm) above and centered over en exposure fire derived from a I in. (25 mm) depth of alcohol within a 1 Pt' (0.09 m') pan. The panels were exposed to intermittent flame impingement. UT .ECH BTi.TTL.;r_TPT 01 e77c see e.02 'i" 'cit rn+bi1ln 3H1 'JJ '2:60 S5, LT -Inc FACTORY MUTUAL Rrs1ARIN CORPORATION Page 2 OV7A9.AC J . 3 tests 3-6 inclusive were simile' to tests 1 and 2 except thet water was sprayed applied at a rate of 10 gpm (37.8 dm' /min) onto the panels before and during the fire exposure. 3. 4 Test 7 was conducted on an (8 x 10 ft (2.4 x 3 m) telling grid assembly with the fire exposure located under the center ceiling panel . A fen was positioned to induce a low velocity draft on the underside of the ceiling. IV TEST RESULTS 4. i Tests i_ and 2 were conducted to determine the effect of heat and- flame on the panels and their ability to melt nut quickly. Performance was noted at various time intervals during exposure to the fire source. 2b sec. - slight sagging of panel 40 sec. - flame burned through 90 sec. - sides of panel separated in center along short axis 4. 1. 1 Burn-through, in 40 seconds, indicated heat will reach sprinkler quickly and the ceiling tile will not interfere with prompt sprinkler operation. 4 2 test 3-6 were conducted to determine if water would Cool the panels and delay Fall-out. As the water flowed onto the panels, some was absorbed and some ran off prior to ignition of the exposure. Panels remained flat during application of the water prior to fire exposure. Performance was noted at various time intervals during exposure to the fire source. 25 sec . • slight sagging of panel . Water accumulating. 65 sec . - sagging and water accumulating increased to where the weight of water and thinning of the panel through melting, caused the panel to fall out . 4 3 Test 7 was performed to simulate Favorable conditions towards creating a surface spreading fire an the underside of the ceiling. 4.3. 1 The exposure was arranged SO that flames impinged on the panel nearest the fan. No flaming over the surface of the panels was noted. 4. 4 Since the oerfnrmance was satisfactory for the conditions employing 1 in. (25 mm) thick panels. it would also be deemed satisfactory with thinner panels and/or a more severe exposure. V FIELD INSTALLATION 5. 1 S rinklered Areas 5. 1 .1 For use below Automatic sprinklers, the individual panels must be installed in a metal suspension system and have minimum nominal dimension of 2 x 2 ft (0.6 x 0.6 m) . 1 1 5. 1.2 Clips used to prevent normal drafts from lifting the panels should limit the upward motion only and permit the panels to drop from the suspension system without restraint. 1 5.2 Unsprinklered Areas 5.2.1 In noncombustible buildings having occupancies that do not 1 require sprinkler protection, this product may be installed as layin. ceiling panels within a metal Suspension grid system without creating a need for sprinklers. 1 VI MARKING 6.1 The manufacturer shall apply the FMRC name or Approval Mark on all 1 packaging of the Approved ceiling panels. 6.2 The manufacturer agrees that use or the Factory Mutual Research name or I Approval Mark is subject to the conditions of the Factory Mutual Research Approval . Such conditions and limitations mint be included in all references to the Factory Mutual Research Approval - 1 VII MANUFACTURER'S RESPONSIBILITIES 7.1 To assure compliance with installation procedures in the field. the I manuracturer shall supply to the installer such necessary instructions or assistance as required to produce the desired performance achieved in the tests. I 7.2 The manufacturer shall notify the Factory Mutual Research Corporation of any planned change in the Approved product prior to general sale or distribution. All requests for changes shall be made end agreed to in writing Iutilizing FMRC Form 797, Approved Product-Revision Report. 7.3 Continued Approval is based upon the fabrication of the ceiling panels in accordance with this Approval Report, satisfactory field experience, and I continued use of acceptable quality control procedures as determined by Facilities and Procedures Audits. IVIII QUALITY AUDIT INSPECTION AND RE-EXAMINATION 8.1 Quality audit inspections will be conducted periodically at the I manufacturing facility at Gilman, Cl to determine that the quality and uniformity of the ceiling panels have been maintained and will provide the soma level of performance as originally Approved. 1 8.2 A re-examination of the product may he required to assess any changes in field installation procedures or end-use limitations. The current Factory Mutual Research Approval Guide shall be consulted. 1 1 1 Ot'SO'd OtcTIL.£ItT O1 9"7S 688 20E 'Ili ';Dae HHOltg 3H1 d3 P2:60 Se, LT mr PACTOBY MUTUAL aeSLAlC11 cnarOgatoN Page 4 OV7A9.AC Ix CONCLUSIONS 9. 1 Tests results show Oilman Brothers' Cellulite Suspended Ceiling Panels, installed in a metal suspension system will not significantly affect the action of automatic sprinklers installed above and will not produce a spreading fire on its surface. 9.2 Cellulite polystyrene lay-in place ceiling panels or nominal 2 x 2 or 4 rt (0, .6 x 0.6 by 1.2 m) by 1/2 to 1 in. (13 to 25 ma) thick met rectory Mutual Research approval requirements subject to limitations noted in Section V. 9.3 Approval is effective when the Approval Agreement (Form L-15) is signed and returned to Factory Mutual Research Corporation. 9.4 Continued Approval will depend upon satisfactory Field experience end periodic Quality Follow-Up Facilities end Procedures Audits. REPORT BY: HFPORT APPROVED BY: 7 e aura rd C. A, mi h Manager , Materials Section JEBIdo Test Date: Notebook No. 227