Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
38B-227 (5)
55 FAIRVIEW AVE BP-2017-1020 GIS4: COMMONWEALTH OF MASSACHUSETTS Map:Block: 38B-227 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGL c.142A) Category: SOLAR HOT WATER SYSTEM BUILDING PERMIT Permit# BP-2017-1020 Project# JS-2017-001760 Est.Cost: $12100.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const. Class: Contractor: License: Use Group: SPARTAN SOLAR 107869 Lot Size(sq. R.): 5532.12 Owner: STOVER GERRIT T Zonbag.: URB(100)/ Applicant: SPARTAN SOLAR AT: 55 FAIRVIEW AVE Applicant Address: Phone: Insurance: 10 CHARLES ST (413) 768-0095 GREENFIELDMA01301 ISSUED ON:3/13/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF MOUNTED SOLAR HOT WATER SYSTEM 3 - 4'X8' PANELS, FLUSH MOUNT POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House# Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy signature: FeeType: Date Paid: Amount: Building 3/13/2017 0:00:00 $75.00 212 Main Street, Phone(413)587-1240. Fax: (413)587-1272 Louis Hasbrouck—Building Commissioner File 4 BP-2017-1020 APPLICANT/CONTACT PERSON SPARTAN SOLAR ADDRESS/PHONE 10 CHARLES ST GREENFIELD (413)768-0095 PROPERTY LOCATION 55 FAIRVIEW AVE MAP 38B PARCEL 227 001 ZONE URB(100)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid r Building Permit Filled out *Il 9 Fee Paid Typeof Construction: ROOF MOUNTED SOLAR HOT WATER SYSTEM 3 -4'XS'PANELS,FLUSH MOUNT New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or ' ense 107869 3 sets of Plan of Plan THE FO OWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON INF ATION PRESENTED: Approved Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:§ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding Special Permit Variance* Received& Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management Demolition Delay 3 7 3 -�'7 Signature of iuildmg Of sial Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. * Variances are granted only to those applicants who meet the strict standards of MGL 40A.Contact Office of Planning& Development for more information. ----- Department use only 1320.1City of Northampton Status of Permit !� Building Department Curb Cut/Driveway Permit 212 Main Street Sewer/Septic Availability Room 100 Water/VVell Availability Northampton, MA 01060 Two Sets of Structural Plans phone 413-587-1240 Fax 413-587-1272 Plot/Site Plans Other Specify APPLICATION TO CONSTRUCT,ALTER, REPAIR, RENOVATE OR DEMOLISH A ONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION 3 St) -CIA'? 1.1 Propecrty Address: This section to be completed by office 55 P. /'0.t CVI `I3 Ave,. Map Lot Unit NIord4.YY.,�4av\ Zone Overlay District Elm St District CB District SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: n Gerr'ti— S±o.lec 5-J a+(' e V ,u3 J�V2 Name(Print) Current Mailing Address: '113 - 5gv `i t'i39 g Telephone Sp 5- g 5(3 Signature 2.2 Authorized Anent: /; S ccfwy ec a*� 10 ( kc&ckS St , ��raant]e4/ AM Name(Prin Current Mailing Address: o t'3 a 1 `113 7�8 0Q4S Signature 1 Telephone SECTION 3-ESTIMAT CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Only completed by permit applicant 1. Building d 1 t too (a) Building Permit Fee 2. Electrical (b) Estimated Total Cost of Construction from(6) 3. Plumbing pi u -! 11 ��1 r Building Permit Fee 4. Mechanical(HVAC) Uv1 42006 Wo to 5. Fire Protection d 6. Total=(1 +2 +3+4+5) 1, a , (CO Check Number 6630- This Section For Official Use Only Building Permit Number: Date Issued: Signature: Building Commissioner/Inspector of Buildings Date • Section 4. ZONING All Information Must Be Completed. Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be filled in by Building Department Lot Site Frontage Setbacks Front Side L: R: L: R: Rear Building Height Bldg.Square Footage % Open Space Footage % (xi area minas bldg&paved parking) N of Parking Spaces Fill: (volume&Location, A. Has a Special Permit/Variance/Fin ing ever been issued for/on the site? NO O DONT KNOW YES 0 IF YES, date issued: IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW O YES O IF YES: enter Book Page , and/or Document# v�l B. Does the site contain a brook, body of water or wetlands? NO UCDONT KNOW © YES IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO 0 IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO IF YES, describe size, type and location: E. Will the construction activity disturb(clearing, gradingexcavation,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO p[ 1 IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 5-DESCRIPTION OF PROPOSED WORK(check all applicable) New House El Addition ❑ Replacement Windows Alteration(s) ❑ Rooting El Or Doors C Accessory Bldg. ❑ Demolition ❑ New Signs [0] Decks [p Siding[0] Other 04 Brief Descriplion of Proposed ` ` 1 1 `� r ) Work: Ren Nrfkx (So kat w�Y7f- SS1�M ] 3 y x0 DcfvW S 1 +1,-)41W1OVvk Alteration of existing bedroom Yes No Adding new bedroom V Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet 6a.It New house and or addition to existing housing.complete the followlna: a. Use of building '. One Family Two Family Other b. Number of rooms in each family unit. Number of Bathrooms c. Is there a garage attached? d. Proposed Square footage of new construction. Dimensions e. Number of stories? f. Method of heating? Fireplaces or Woodstoves Number of each g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No. I. Septic Tank City Sewer Private well City water Supply SECTION 7a-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR CONTRACTOR APPLIES FOR BUILDING PERMIT I, GI° 4- J'oV€ as Owner of the subject property (/� �/� hereby authorize SpaCiroW\ V]O c 0YV to act on my behalf. in all matters relative to work authorized by this building permit application. Signature of wn Date Mit& ? 72 ( I, Cif vlW \ V1V f� WhO , as Owner/Authorized Agent hereby declare that th statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. ctc-kavA (-:--IlorJO Print Name ala? 201 /— Signature of er A nt Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor:��fL1 Not Applicable r❑��-1 Name of License Holder: • D CtrkCk)t\ Glo y\.O CS-- tO KDC\ // r \\- 1 ,11r�{ / S(� I -\ 1I, 1 f1� License Number (a l"Yscsr `eS v\ A Are ONe3 fl Jw\ O\701 ExPirationlDta• , I 2--o 15? AMU te i \\\ c"----____ 11(cS— Oo95 Signal Telephone 9.Registered Home Improvement Contractor: Not Applicable 0 S c..ritif‘ . Soar-- I7G 5C3 Company Nair* Registration Numper AAA.c R f I% I2O\$ Address Expiration pate pIrl Telephone S Aua SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L.c.152,§25C(8)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building� permit. Signed Affidavit Attached Yes t'SIDilNo 0 11. - Home Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellings of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who docs not possess a license,provided that the owner acts as supervisor.CMR 780, Sixth Edition Section 1083.5.1. Definition of Homeowner: Person(s)who own a parcel of land on which hclshe resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such work performed under the building permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also he advised that with reference to Chapter 152(Workers' Compensation) and Chapter 153(liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned"homeowner'certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature '$/� Massachusetts Workers'Compensation Insurance Plan AcadM/V1' 33391 MrriaMWNnce Co NMI r Ria 3 vices MmIn49tered by BeM1Jey Assigned Risk Services P.O.Box 59143,Mlnneepolls,Minnesota 65/580143 ASSIGNED RISK SEAVMCES Toll Flee(88$)548-1431 Fax(886)215-8118 wvw. ed eyesL3nearibLemin policytiehrbeeeberklewisk.COM INFORMATION PAGE =newel Of No.New Policy Number: MAARP302432 SPARTAN GIORDANO RiskID: 4747 dba:SPARTAN SOLAR Tax : 11104593@318 10 CHARLES STREET Policy Period: From: 11/09/2016 Greenfield,MA 01301 To: 1110912017 Endorsement Date 11109/2018 Date of&daaing: 11/1012018 II Individual 0 Partnership 0 Corporation 0 Other )Ther workplaces not shown above: See 6ch.duie 2. The policy period ie from 12:01 a.m.i 1/09/2010 lo 12:01 sm.11/09/2017 at the insured's mailing address. 3.A.Workers'Compensation Insurance:Part One at the policy applies to the Workers'Compensation Law of the states listed here: MA B.Empivyen L Mliy insuranpe:Pmt Two tithe pdIcy appaes to work in each bate ksied in item 3A. The limits of our liability under Part Two are: Bodily Injury By Accident $100,000 each accident. Bodily Injury By Disease $500,000 policy limit. Bodily injury By Disease 6100,000 each employee. C.Other States Insurance:Part Three of the policy applies to the states,if any,fitted here: SEE 20-03411(8) 0,This policy Incudes these endorsements and schedules: WCO00415B WC9W001A WCaMeO1 4.The premium for iris policy wig be determined by our Manua of Rules,Classifications.Rates and Rama Pins. Mt ir,armadon required below is suteed to vatlfea[pn and Mange by audit. PREMIUM BASIS RATES ENTRIES IN THIS ITEM,EXCEPT AS SPECIFICALLY PROVIDED ESTIMATED ESTIMATED TOTAL PER$100 OF CODE ELSEWHERE IN THIS CONTRACT:DO NOT MODIFY ANY OF ANNUAL ANNUAL REMUNERATION REMUNERATION NO, THE OTHER PROVISIONS OF THIS POLICY. PREMIUM See Schedule Premium Summary Total Estimated Annual Premium $1,195.00 Minimum Premium : $460.00 Total Fees and Assessments $54.00 L Total Fees and Premium $1249.00 Total Amount Paid ($1.248.00) Total Amount Due $1.00 Agency Narita end Address Shipped Patrick M Agency Mlrlck Ins Agency PO Box 375 Shelburne Falls,MA 01370 DATE: 11/10/2016 /'� t.�N- �_ SignaNre� , ,.- E_ /,�— ,a anc yrpn mess Wass waw card m Carpons.sm mw.nn t..d wm ro 010tom. OM m Snot*Cc.,wacm,anton hnway. WC Pg 0001 massacnusens Workers' Compensation Insurance Plan Ie + Acadia Insurance Co CCI Cartier Code 33391 cik,1SK Y Administered by Ssrkby Assigned Risk Services P.O.Box 59143,Minneapolis,Minnesota 5545&0143 SERVICES Toe Free(868)5487431 Fax M8)215-8118 www.bwIdeyessignedrak.mm pollcyservicn beddeynsk.eom INFORMATION SCHEDULE 1. The Insured: Policy Number. MAARP302432 Risk lD: 1133797 SPARTAN GIORDANO Tax ID* 47.1450516 dba:SPARTAN SOLAR Policy Period: From: 1110912016 10 CHARLES STREET To: 11/09/2017 Greenfield, MA 01301 Endorsement Date 11/09/2016 Date of Mailing: 1111012016 changed as set forth below are hereby made.with respect to the estimated remuneration,premium and/or rates. PREMIUM BASIS RATE PER$100 ESTIMATED ESTIMATED TOTAL OF ANNUAL CODE NO, CLASSIFICATIONS ANNUAL RENUMERATION RENUMERATION PREMIUM State: MA Premium Perrot 1110912018-1110912017 Location: N1 SPARTAN GIORDANO, 10 CHARLES STREET,Greenfield, MA 01301 5538 SHEET METAL WORK-SHOP& $20,500 4.58 $939.00 OUTSIDE-NOC&DR Total Manual Premium $939.00 0000 Employers Uiab ifity Increased Limits 0 $0.00 Subject Premium $939.00 Total Modified Premium $939.00 Total Standard Premium $939.00 0900 Expense Constant $250.00 9740 Terrorism 0.03 $6.00 0931 Short Rate Penalty Premium 1 $0.00 Massachusetts Department of Industrial 0.0575 $54.00 Accident Assessment Repotted Policy Minimum Premium $460.00 Estimated Annual Premium $1,195.00 Total Amount Due $1,249.00 Policy Summary 11/09/2016 - 1110912011 Total Manual Premium $939.00 WC 99 00 01 A Pagelof2 The Commonwealth of Massachusetts ,_— Department of Industrial Accidents =it 5 Office of Investigations 1 4 le== _ 1 Congress Street,Suite 100 ill— Boston,MA 02114-2017 www.mass.gov/dia Workers' Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Legibly Spartan Solar Name(Business/Organisation/Individual): _ Address: 10 Charles St. City/State/Zip:Greenfield, MA 01301 Phone#:413-768-0095 Are you an employer? Check the appropriate box: Type of project(required): 1.IN I am a employer with 1 4. ® I am a general contractor and I employees (full and/or part-time).* have hired the sub-contractors 6. ®New construction listed on the attached sheet 7. ® Remodeling 2.0 I am a sole proprietor or partner- ship and have no employees These sub-contractors have 8. ® Demolition working for me in any capacity. employees and have workers' 9. ® Building addition [No workers' comp. insurance comp. insurance.: required.] 5. ® We are a corporation and its 10.0 Electrical repairs or additions 3.0 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] ' c. 152, §1(4), and we have no Solar Hot Water employees. [No workers' 13.® Other comp. insurance required.] *Any applicant that checks box#I must also fill out the section below showing their workers'compensation policy infomiation_ 'Homeowners who submit this affidavit indicating they arc doing all work and then hire outside contractors must submit a new affidavit indicating such. :contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. If the sub-contractors have employees,they must provide their workers'comp.policy number. I am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name:Acadia Insurance Company Policy# or Self-ins. Lie. #: MAARP302432 Expiration Date- 11/9/2017 Job Site Address: 5J Fgcf`tl 7�e City/State/Zip: {`terP'nQMp ) MA Gio60 Attach a copy of the workers' compensation policy declaration page(showing the policy number and expiration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to $250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do hereby certify and r t e ains and penalties of perjury that the information provided above is true and correct. Signature: Date: ala7/aQ q- Phone#: 413-76800 5 Official use only. Do not write in this area,to be completed by city or town official. City or Town: Permit/License# Issuing Authority (circle one): 1.Board of Health 2.Building Department 3.City/Town Clerk 4.Electrical Inspector 5.Plumbing Inspector 6.Other Contact Person: Phone#: EXIST. 2x6 Ncy, EXIST. ]x8 RIDGE 011 OF 144:4.. EXIST. 2x6 ari, ..---'1' (6) 12d COMMON I�i RAciv: '. NAILS, TYP. Ho.436 - wf F y 'AL AO -IIUNi'atbi.. 2X6 ✓ rOMMON NAILS ,., TYP. ' 1 }' MINIMUM 2x6 SISTER BEARTYP.44 p HURRICANE TIIEE,, TYP. e _ rip EXIST. JOIST J ,I, 323'-7' ® SECTIO\ e= 1'-0' Structural Support PROJECT: CLIENT: LOCATION: DRAWING TITLE: • & SOLAR HOT WATER SPARTAN SOLAR 55 FAIRVIEW AVE. ROOF esign Services & 10 CHARLES ST. NORTHAMPTON, MA FRAMING 236 S.Shirkshke Rd. PHOTOVOLTAIC PANELS GREENFIELD, MA REINFORCEMENT S K 2 Conway. MA 01341 INSTALLATION 913-522-7771 3 10'-7' ± 28'-9' / S ALTERNATEEESK3FOR Th_ __..1. _--1LJL_- ___ —T -__._.T__ 1 -- .___ _. 1I — 1 I I N I a I I mx tx N Cu 4 Q " La 9 1 1 I 1 .___ T _ __ N -- Cu F I a >- �r� iN OF MA ".r. N W % No A56Ea > 1 A.EN6 —I— — 1 ' 1ROOF FRAMING PLAN SKI NOT TO SCALE uniStruCtural SupportPROJECT' CLIENT: LOCATION: DRAWING TITLE &esign Services SOLAR HNT WATER SPARTAN SOLAR 55 FAIRVIEW AVE. ROOF 6 ]0 CHARLES ST. NORTHAMPTON, MA FRAMING I/ 230 S.Srnrksnno RE. PHOTOVOLTAIC PANELS GREENFIELD, MA PLAN K 1 Conway, MA 01341 INSTALLATION 413-5229]]1 jiik • THE-IIEM 0 SERIES S U II E fl fl t H inc. GLAZED FLAT PLATSPECIFICATION ESHEEET THE CHOICE IN COMMERCIAL SOLAR WATER HEATING TECHNOLOGY Aluminum Absorber with Blue Tec Absorber Coating Secondary Silicone Primary EPDM Glazing Seal Glazing Seal Low-Binder Fiberglass Insulation - / Rigid Foam Insulation j Painted Aluminum Backsheet` 'w Low Iron Tempered Glass EPDM Grommets Integral Mounting Channel Extruded Anodized - Aluminum Casing and Vent Plugs Capstrip 5%Silver Brazed Joints Type M Copper Riser Tubes and Manifolds Stainless Steel Fasteners Riveted Corners PROTECTING OUR ENVIRONMENT-SINCE 1978 OD[00111III[. ThermoRay SERIES SPECIFICATIONS nli aiU O ; 3 „I gg '� o al �o'x�4r�4 ., - ,i? ge a �a�c� - a 9 as c TRa-00 482 1222 3.25 409 37.2 130 87 1]0 139 0.009 12 51.38 1 115.63 TPB-32 48.2 983 325 328 29.7 98 ]I 097 1.11 6006 12 5138 1 9363 ASTM[330 Maximi m Test bad 190 psf-Applythe appropriate facto of safety according ro thetest standardsand local building code regu iremenn when deslg ninq a saint thermal system THERMAL PERFORMANCE RATINGS* category (T-Ta) CLEAR MILDLY CLOUDY DAY CLOUDY DAY DAY liatidgfiOPap AI-9°F) 1471 1115 758 6(9°r) 1340 984 627 C(36°F) 1136 789 445 10190M) 774 445 146 E(144 F) 452 171 - A-Pool Heating(Warm Climate) B-Pool Heating C-Water Heating(Warm Climate) 0-Water Heating(Cool Climate)E Air Conditioning/Industrial Process Heat. Thermal performance is obtained by multiplying the collector output for the appropriate application and insolation level by the total gross collector area *Collector ratings are derived from the Solar Rating&Certification Corp ISRCQ Document AM-I and Standard DG-100.Tested at water design flowrate. ENGINEERING SPECIFICATIONS (Performance spedficarmnssubjea totestin e error nr-FS 3yh) The following shall be the specifications for the solar collectors.Collectors The insulation shall be foil-faced polyisocyanurate foam sheathing board of shall be SunEarth ThermoRay model , and shall be of the glazed lig- a minimum 1 inch thickness,silicone in place to the aluminum backsheet, uid flat plate type.Collectors shall be tested in conformance with ASHRAE covered by low-binder fiberglass of a minimum I inch thickness,providing 90-2003 and Solar Rating and Certification Corporation(SRCC) 100-05,and thermal isolation of the foam from the absorber plate.Total thermal resis- have their thermal performance rated according to SACC Document RM-1. tante shall be a minimum of R-12.The sides and ends of the collector shall The collectors shall be certified by SRCC and listed by the International be insulated with a minimum of 1 inch foil-faced polyisocyanurate foam Association of Plumbing and Mechanical Officials(APMO). sheathing board. GENERAL: ABSORBER PLATE AND PIPING: The dimensions of the collector shall be inches in length, The absorber shall consist of an aluminum plate of no less than .017 inch inches in width and 3.25 inches in depth.The collector casing shall be an thickness.Risers shall be a minimum of.39 inch 0.D.copper with a wall thick- anodized aluminum extrusion(AA 6063 T6),minimum thickness 0.060 inch, ness of.020 inches on no more than 4.7 inch centers continuously laser weld- with an architectural dark bronze finish.The casing shall have a notched ed to the plate.The risers shall be brazed to 1.125 inch O.D.Type M copper framewalls for ease of plate removal and reinstallation,Sheet metal screwed manifolds utilizing a copper phosphorous brazing allow with no less than a fasteners shall be stainless steel (18-8#10).The backsheet shall be painted minimum 5 percent silver content,and conforming to the American Welding textured aluminum not less than.014 inch thickness.Al inch vent plug shall Society's BCuP-3 classification. EPDM grommets shall isolate the manifold be installed in each of the four corners of the backsheet to minimize con- from the aluminum casing.The absorber plate shall be designed from a 160 densation.An integral mounting channel shall allow the solar collector to be psig maximum operating pressure. mounted without penetration of the extruded aluminum casing. ABSORBER COATING AND PERFORMANCE CURVE: GLAZING: The absorber coating shall be blue sputtered with a minimum absorptivity The collector glazing shall be on sheet of low iron tempered glass,with a of 95 percent and a maximum emissivity of 5 percent.The instantaneous minimum of.125 inch thickness 615625 on TAB-401,and a minimum trans- efficiency of the collector shall be a minimum V-intercept of 0.751 and a slope missivity of 91 percent(89 on TRS-40).The glazing shall be thermally isolated of no less than-0.734 Btu/ft2ehrt°F. from the casing by a continuous EPDM gasket.There shall be a continuous Note:Please refer to the SACC website at wwv.solanrating.org for the current secondary silicone seal between the glass and casing capstrip to minimize y-intercept and slope for each collector. moisture from entering the casing. INSULATION: Due to SunEarth's policy of continuous product improvement,specifications are subject to change without notice. 010 IIRDIRTH 111[. • 8415 Almeria Ave.•Fonttna,CA 92335 19091434-3100 • Fax vl wwwsunearthinc.comnayttm rar3t_ror euro INK — Y.''X'SP`L S /ti.::5'n[ <5: \. .,. > .<..-'AT Sr,, ` `:t 'RC^;/cT .;.S::5<%eeSaYS`eerti''ti5(x F c CERTIFIED SOLAR COLLECTOR �>W1S pSUPPIJERBRAND: ThemaRayS"- S42s Al111InAMODELTRB.324j,.PkIl 8425 AlmeAa Avenue , FpnbneGA92335USACOLLECTOR TYPE Glazetl Flet Plate 2t && wwwsunearthinccom CERTIFICATION M: 10001804 (.S OriginalOertfication: Mardi Ofi,2013 S�h TY Expiration Date: February 01,2025 0y ! solar collector listed below has been evaluated by the Solar Rating&and atiCorporationfa (SRCCTM),an ANSI aces,and and EPA recognized l"Ja. yT Certification Body,in accordance with SRCC OG-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors,and has been certified by yYia Eh the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the documents incorporated therein by reference. p"jj /X _ __ _ _ O. ISV MA y COLLECTOR THERMAL PERFORMANCE RATING .X. KJ tt-ours(thermal)Per Panel Per Day Thousands of Btu Per Panel Per DN ✓� Climate-> High Radiation Medium Radiation Low Radiation Climate-s High Radiation Medium Radiation Low Radiation `> xT Category (6.3 kWh/miday) (4.7 kWh/m'day) (3.1 kWhlm'day) Category (2000 BtuIW.day) (1500 Btu/t.day) (1000 Btu/h'day) c� TT (Ti-Ta) (Ti-Ta) x Tr A(S°C) 14.1 10.7 7.3 A(-S'F) 48.3 36.6 24.9 Sh 3{12 B(5'C) 12.9 9.5 6.0 B(9°F) 44.0 32.3 20.6 k�h jai C(20'C) 10 9 7.6 4.3 C(36'F) 37.3 259 14.6 S * 0(50'C) 75 42 1.4 0(90'F) 25.4 14.6 CSX .�° E(80°C) 4.3 16 0.0 E(144'F) 14.7 5,5 0.0 tr� A-Pool Heating(Warm Climate)B-Pool Heating(Cool Climate)C-Water Heating(Wane Climate) f 1 jX(TX D-Space&Water Heating(Cool Climate)E-Commercial Hot Water&Cooling 92 X13° -1 COLLECTOR SPECIFICATIONS ,. '''Lx: Gross Area: 3850 TIF 3283 W Dry Weight 44 kg 98 lb s l& 2.t Net Aperture Area: 2733 m' 29.42fi Fluid Capatty: 2.9 Neer O8 gal r/h MvohxArtm Area: 2810 ' 30.25W Test Pressure: 1103 kPa 160 psi 1° <22 �' TECHNICAL INFORMATION Tested N accndenw with:ISO 9806 As yd ISO Efficiency y Equatlon[NOTE:Based on gross area and(P)=TI-Tal 5" LSI UNITS: 0=0748-3.72370(P/G)-0.00670(P'/G) V SC Intercept 0.751 Slope: 4.167 W/m'.'0 `1 A/ IP UNITS: 0=0748-0.65627(P/G)-0.00066(P'/O) V Intercept 0.751 Slope: -0.734 Btu/hr.ft'PF `' 11 T S F j Incident Angle Madttbr Teal Fluid: Water �� 0 10 20 30 40 50 60 70 Teed Mass Flow Rate: 0 0199 kg/(s ml I 14.750/(hr I ) y &<<7 Kra 1.00 0.99 0.98 0.96 094 0.88 0.77 Ir ad Safety Rena:11 Yfh ?v 1 REMARKS: L,L: c ) L j ' S fy5 \ vZ xy yr .5. Fy ygal(IGagy sT C , _AA__//i Al yST Lw1NtcfAdc ® i S,'. '4 Technical Director 06-100 CERTIFIED `< Print Date:July,2013 j ©Solar Rating&Certification Corporation1' ® y r a > ww.w.w sola at gorg•400 Hgh Pot Drive Suite 400 a Cocoa Florida 329226•(3221)2133-603377.'•Fax(321) 821-0910 J.�? y ��.R S7(7.YC Y` rel 2.Y tc ..<<TCct/2CK ` C.< N�. 1<' .^ ,4 Y'� �i�.l`4S.rf4LFF.C'(YJ`4`(/..`Cn Y'SI`2. rX�[��t' C � Page 1 of 3 K2'i SS( scasi y.riS e S.:;.�, r n ,;rr 37: r ^a r:2:3W`rX:2A X.:^r r31 aSySrvraY :" P1223 1 ��g�A11FIiAl/�� ..""1 ,--4, CERTIFIED SOW2COLLECTOR rx „.....b ...mime_ g SUPPLIER'. BRAND: ThermoRay S ��•Inc. MODEL TRB-32 c "s ® � 8425 Amenia Avenue �� J COLLECTOR TYPE: Glazed Flat Plate °tS OJ. co Fontana,CA 92335 USA Y� ,, ,y www.sunearthinc.com CERTIFICATION a'. 10001804 L; rti �a Original Certification March 06,2013 SbV Expiration Date: February 01,2025 kh Y hx. The solar collector listed below has been evaluated by the Solar Rating 8 Certification Corporation"' (SRCC'),an ANSI accredited and EPA < r.1 recognized Certification Body,in accordance with SRCC 0G-100,Operating Guidelines and Minimum Standards for Certifying Solar Collectors, sq c, and has been certified by the SRCC.This award of certification is subject to all terms and conditions of the Program Agreement and the y x documents incorporated therein by reference. ,e`'J S' rS' ADDRIONAL INFORMATION(dick here to retum to the rating page) z' YTest Lab'. TUV Rheinland PTL.LLC Test Report Date' February 01,2013 2 7„-c> Test Report Number. RSI-KI0120809 Test Locton'. outdoors S Br x‘h A/ SOLAR COLLECTOR CONSTRUCTION DETAILS Grim Length: 2-490 m Grose Wk11h: 1.225 m Gros Depth: 85.000 mm 0 COLLECTOR MATERIALS A , Outer Caws Glass sheet Fstlotre back Aluminum Dec[lamination: Fiber,Foam �� Inner Cover. None Endears side: Aluminum Side Insulation: None,Foam r.Y Absorber Description: Tubes connected to Single Sheet flaw Pattern: Parallel/Harp c Czz Riser Tube: Copper Rn: Aluminum At• Absorber Coaling: Selective Tube to an ticnnedica Laser Weld it f 1 5 .ti GLAZING Outer Carer Inner Cover '-" yTr �ti Material: Glass sheet None r? Surface Cheradais : Textured 1- Thickness: 3.8 mm N/A VT r2 Trnx neeelvity. Medium(87-89.9%) q rti Length: 2.440 m - - - - - t, �z Width: 1.134m y ,> `- Tube Glazing to Header Endows Seal: EPDM gasket `r ' F 2� S", k ABSORBER: Absorber Casing: Selective . 5 'r Header Material: Copper HeaderOD: 28.5mm Header Wall: 0.8mm • Riser Tube Material: Copper Riser Tube OD: 9.9mm Riser Tube Wall 0.4mm 'i Thickness: �rti� `;t::" Rn Material: Aluminum Fin Thickness: 0.50mm 'v^ Sh > E. ti yY r;-, rC5 ;S, b9N11t1(A, 15 ~.S\tlf//. $ 1 2s OG-100®IED s tsi zti rti. v y1^zr'v�',r.<1( 1r'z y"YS s^y t<,t,;`1 (e& ®>?.<?;\1 "ti<'.7A37...fatllX>rr-:?,.�".*7)ML'i. r te- r r r 6) ;��c>cc�,r, ,:, d o f� ti ti Z c ti .., Y C �, r m �., -:: 4 -o w ,:. tiY -;, c S'C�4�ti2r2,�'�'ts'.�s Page 2 of 3 £JO£aged c2iV/ 6-(e ` (O2V�Z�*O1V2is„`4rS.;'2�i Y'i1'cr/ZeKN' V;Vis >C76-..;VICs 'VJVV. X 26VV t):„ :(4;` 2',:,�r1YrMryr;'7"�xOCV''Z 1 X S ; 03130tl33001-90 E. ;wr 9_", 7 r ;. ,ti 4 I 44 4 yyti Xz X Fti X Yx5 V X 0'0 LZ't 0 08 xi y 0'0 6L 0 0 OS yJ Y$ 0'0 Z£'0 0 OZ tV �s ow w e,de ed MU/ ?: ' do mad do mos z d01:10 31111sSaad tx C2 iti 998 6991 9861. L91.8 £8ZZ �' OL OS OS 01 0 ' rT [[rutin 0001•O'e1111 ,i 7-, Mx:wee:Q-ed lol4OO IGMOd ','a•. 4 % smaoS singingeewwamg d aaua .h :ww0SZ wood :marl Lein0-e°PIS wwOSZ wood WortmolpS-*ea , auoN Skirl iouul-SOPS two 0'66La91f aaSal dol-'peg i s k saupryL SAL uoa:ol aagoNl WI togeoo1 S`;3 ysy''1 :NOLL 61SNI s 7 }v ,s y5 PPM lase 1401 w T3 l Wwdu+.d co BC :teed•qd 10 t00ual :MCKIM gig y1 MS=sap MOM :sews ,> ?'st t moll o iaQufN tow, tZt nolood4eT1 Ot ROW lB reeunN Y� Ay,then/piped :WOPed MOW `' 6CO y1 X X ,3 F Sv sj Y, . -ta4-- =' > s1 O� amite :s..Tsi.0,?5*`5�xi v s,,-s`"v.>.4a'r i,":"5,,"' ,cx ti'K. ,- >7a�r . s.,:cc>. aKti;;Ks_N,S-> :; v�� rx'yh�.N.> x.,... ;,'5 91:104.:t STIEBEL ELTRON -f , �a � Simply the Best �er .�•. • • "p ..:r x"i nr to (.yc + -15-Yrs, �, u: • f'�3 1 i �„3c, •i ) e ;#1rr"i : rat S 7 y,} .. r Yd Tf4Et �C'v'itiates .Y .w- �r. �,wrt � L •,{�':' � . `.Ara .- . .•i... .. ... _ <. �.��.`rij� • • New! Single coil tanks 3n eeLevaoe with electric element _; • • • • Tanks being porcelain-fired at Shekel Eltron's factory in Nolzminden,Germany . 3 r .ry. ,yi ,,^^aS.'�� Prvt A 1 '} tt �; 4 YZ % ge t }• • t, i I foaling MVk. OR Ta l• erbClua1i esuits In Long Service Life FOR ALL SOLAR, GEOTHERMAL Hacked By A Lifetime warranty > Sacrificial Anode Rod OR HYDRONIC APPLICATIONS Up To 3" R-21 Urethane Foam Insulation ■■ L'�t, ISO 9001 /-'�\ For Low Standby Heat Loss Sus�a "" ""° LFI ETIME > Large Clean-Out Port For Ease Of Maintenance Engineered in Germany *J Intertek 800.582.8423 www.stiebel-eltron-usa.com y - ' A "z m It 4 . }r x, : n. ,+" s• :t;' 'gym-.'a # , "'?, o .[.••p a t ...net` u:e. _..",.,.._._,', Single Heat Exchanger with Electric Element `fs1TeO Hot water outiet\ Sacrl ficial -_.l �� r de LIFETIME box V * y ® i Heat 't� a ha rge Sf.bei EPron SBB and SB-E tanks eo' and heat exchangers are warranted 9 � againstatrial def r f I,fe.All Aux iary otherparts, uding h incial Co is erode,a ora 10enols , . 1.-7ware, 5 / cn l cumpl l details old 4>.-.,.....,..vs: inlet - 1 Cold water inlet DHW Tank Model SR 300 E SD 40UE 1 Hat water cutlet Part number 434110 234111 3 tower heat exchanger port 4 Upper heat exchanger port CONTENTS 5 Lower aux liary port Storage capacity 71 gal/3001 €05.6 gal/400 I 6 Upper auxiilary port Heat exchanger volume 2.4 gal/951 3e gal lllll 7 Clean-nal port Surface area of heat 16.1fN ft,5 m= 20.6 It /19 m= 8 T&P valve port exchanger 9 An ode replacement indicator Working pressure 145 PS;/10 bar 145 PEI/10 bar 10 junction box Max.pressure of boiler loop 145 PS 110 her 145 PSI/10 bar 11 Analog lhermOmeter 12 Upper ter pe rata re son nor sleeve HEATING ELEMENT 13 Electric healing element Heating element voltage 220-260V 14 Lower temperature sensors Leve Heating capacity 10,239 BTU/hr/3 o kW Frequency 60 Hz 10 Rated current 12.5 A lam Required circuit breaker 20 A Heating element type Dome element e Heating element material Ceramic 11 Temperature control Knob • with°F&`C scale under nesting el emeet cover •�SP� Set range of thermostat 8MF-167°F'30°C-75°C 11 OTHER Cold/hot water connection I'male NPT liHeat exchanger&auxiliary 1"female NPT 1 connections _ PERFORMANCE DATA 13 6 Standby losses in 34 hours 3.8 kW/9,553 ETU 3.0 kW/10,]36 BTU Pressure drop at 4.4 gpm aiR.'sear l it kPa 4.9 R.head/12kPa Heat exchanger power rating 165,0s0ETU hri4d.4 kW 183.000BTU/hr/53.]kW 5 Inlet 50°F,140°F Outlet 14 Recovery rate(maximum input) 234 gal llrt/805,/hr 158 gallhr/976 I/hr Recovery rate jelectric element only) 117 gal/hr 15181/hr 13]gallhr 15181/br _ �� DIMENSIONS Ar �1 Height 6149`11552 mm 601716) /1544 mm A I Diameter 159116 1650 mm 29Ie /750 mm ] I Insulation thickness Y'/50m.m 6r __ . 1 Diameter without insulation 213re"/550 mm 2S94g"/650 mm 'r"54 xi{ Li ` "NJ;-C x. . y. xu. .... o x Its....;z:* J� L® Single Heat /Silk 533 300 S.SOB 400 Dual Heat drillrea• arra l• Exchanger " „ ....�.�. ..,....., Exchanger a}� -- - �� � 3 . Engineering., rs & eManufacturing Excellence tlE p over90 of German technology • 1S.lArk•hovel e F IR ell 'hl WO e ,. l, TiLsS �. ioneneicial s Am),duly brarnidial n•di.redo ii.„ simbe roe Sr...Vic hot w,ler ,, SBB 300 Plus,SOB 400 Plus,5BB 600 Plus `pg® mn nem wOaYrr be!,r 9+ 0 ry ouIvo.....♦ f....wu. ... �� S . S ,I. n,ha in b.rel...ebb. o.I n o...Hwy su ensures Eget n .: ,.▪.;l,m man ad All gfilleas i LIR.,(sm.Oral,b{.1,1 lay Ayer/era diodes .. $ . E W ., /. `. ,.. V f lli • E . '" n..r.,.o�i � ▪ uk mit Cs integral elan(anent sin Ye•.er Dual inn Iv em.� a . ■�' 649UU, E@ .paen a rz a bored{ xaan nr L. e, Fft'F.T. y e r ti, , STIEBEL ELTRON 014 . - . Simply the Best lir . r "'H, 1: 1924 Sometimes a "Little thing" leads to a whole Lot more Dr. Theodor Stiebel designed the first coil immersion heater and , founded "ELTRON Dr. Theodor Stiebel" in 1924 in a small workshop ; P on Reichenberger Strasse in Berlin, Germany. ...'��.u4` qu�e-it Since then, Stiebel Eltron has manufactured 20 million tankless ✓� electric water heaters, holds hundreds of patents, has won more than fifty design awards, and continues to stay at the forefront of water heating technology. 2015 Continuing to lead innovation in energy efficiency One of the first manufacturers to develop and manufacture heat • pumps and solar thermal water heating, Stiebel Eltron has been a 1 ii I� } technological leader in renewable energy since 1976. I e 1 I 1 " Today Stiebel Eltron is the heat pump market leader in Germany, and g continues creating innovative, energy efficient products for the homes of the future. Stiebel Eltron Family of Energy Saving Water Heating Products TANKLESS HOT WATER _ RENEWABLE ENERGY Gii t'..-. ®' v}J 4 eyy , t v�f & Efficient tankless It .' . , —__ , Solar Thermal&Heat electric water heaters point-of use whole Hou t Pump Water Heaters Tan kless Tankles55P Complete Solar Hol Hear Pump Water Components Water Heaters Distobuted by: motel(Wons plmi In Halzminden,eennane- Stiebel Eltron has been a world leader in the development of advanced water h90 ting year .technologyOfor more th an STIEBEL ELTRON epelus.0anpursuit gu engineering excellence rslndsi products fuy lfilling highetexpectnions of performance ncee 17 West Street highest expectations of West Hatfield,MA 0I088 and reliability. TOLLREE 800.582.8423 They are...Simply the Best PHONE 413.347.3380 FAX413.247.3369 �e prerecsme s info@stiebel-eltron-usa.com p P. rhns nay:r www.stiebel-eltron-usa.com molten on , tie-tree paper b Ybt,ed inks.%I 11015