18C-013 (3) 304 HAT FIELD ST BP-2017-1075 GIS a: COMMONWEALTH OF MASSACHUSETTS Map:Block: I8C-013 CITY OF NORTHAMPTON Lot:-001 PERSONS CONTRACTING WITH UNREGISTERED CONTRACTORS Permit: Building DO NOT HAVE ACCESS TO THE GUARANTY FUND (MGLLcc.1144/2�A) Category: SOLAR ELECTRIC SYSTEM BUILDING PERMIT Permit# BP-2017-1075 Project# JS-2017-001840 Est. Cost: $23760.00 Fee: $75.00 PERMISSION IS HEREBY GRANTED TO: Const.Class: Contractor: License: Use Group: BRIGHT PLANET SOLAR 109128 Lot Size(sq. ft.): 15768.72 Owner: BAKKER CHRISTOPHER&REBECCA SCANDURA Zoning: RI(100)/RR(100)/ Applicant: BRIGHT PLANET SOLAR AT: 304 HATFIELD ST Applicant Address: Phone: Insurance: 5A ST (407) 489-5522 WC AU BU RN MA01501 ISSUED ON:3/28/2017 0:00:00 TO PERFORM THE FOLLOWING WORK:ROOF MOUNTED PV SOLAR ARRAY, 22 PANELS, 5.94KW POST THIS CARD SO IT IS VISIBLE FROM THE STREET Inspector of Plumbing Inspector of Wiring D.P.W. Building Inspector Underground: Service: Meter: Footings: Rough: Rough: House/I Foundation: Driveway Final: Final: Final: Rough Frame: Gas: Fire Department Fireplace/Chimney: Rough: Oil: Insulation: Final: Smoke: Final: THIS PERMIT MAY BE REVOKED BY THE CITY OF NORTHAMPTON UPON VIOLATION OF ANY OF ITS RULES AND REGULATIONS. Certificate of Occupancy Signature: FeeType: Date Paid: Amount: Building 3/28/20170:00:00 $75.00 212 Main Street, Phone(413)587-1240, Fax:(413)587-1272 Louis Hasbrouck—Building Commissioner File#BP-2017-1075 APPLICANT/CONTACT PERSON BRIGHT PLANET SOLAR ADDRESS/PHONE 5A ST AUBURN (407)489-5522 PROPERTY LOCATION 304 HATFIELD ST MAP 18C PARCEL 013 001 ZONE RI(I00VRR(I00)/ THIS SECTION FOR OFFICIAL USE ONLY: PERMIT APPLICATION CHECKLIST ENCLOSED REQUIRED DATE ZONING FORM FILLED OUT Fee Paid Zt Building Permit Filled out 't Fee Paid Typeof Construction: ROOF MOUNTED PV SOLAR ARRAY,22 PANELS,5.94KW New Construction Non Structural interior renovations Addition to Existing Accessory Structure Building Plans Included: Owner/Statement or License 109128 3 sets of Plans/Plot Plan THE FOLLOWING ACTION HAS BEEN TAKEN ON THIS APPLICATION BASED ON IN O ATION PRESENTED: Approved_Additional permits required(see below) PLANNING BOARD PERMIT REQUIRED UNDER:¢ Intermediate Project: Site Plan AND/OR Special Permit With Site Plan Major Project: Site Plan AND/OR Special Permit With Site Plan ZONING BOARD PERMIT REQUIRED UNDER: § Finding_ Special Permit Variance' Received&Recorded at Registry of Deeds Proof Enclosed Other Permits Required: Curb Cut from DPW Water Availability Sewer Availability Septic Approval Board of Health Well Water Potability Board of Health Permit from Conservation Commission Permit from CB Architecture Committee Permit from Elm Street Commission Permit DPW Storm Water Management ",,,,,„ Si:urre of Bu'•ing Official Date Note: Issuance of a Zoning permit does not relieve a applicant's burden to comply with all zoning requirements and obtain all required permits from Board of Health,Conservation Commission,Department of public works and other applicable permit granting authorities. *Variances are granted only to those applicants who meet the strict standards of MGL 40A. Contact Office of Planning&Development for more information. ' _ (�ar 4r City of Northampton Building Department/ ., P8< ., 212 Main Street Room 100 Northampton, MA 01060 kl ` ` -,, phone 413-587-1240 Fax 413-587-1272 "§ " " `,,,i,..:,';-,,....` ;‘..;:.:t%,17,4 � ���'gym' l#r %` APPUCATION TO CONSTRUCT,ALTER,REPAIR,RENOVATE OR DEMOLISH%AONE OR TWO FAMILY DWELLING SECTION 1 -SITE INFORMATION \"CQ�� 1.1 Property Address': This section to be completed by office 301-\ }�0 Ct2\c\ -c:' \--E-Q---k- Zone Lot Unit Overlay District Elm St Oktdet ca DIsetet SECTION 2-PROPERTY OWNERSHIP/AUTHORIZED AGENT 2.1 Owner of Record: 04'3.MvFv QA.n,x- � Aa ie" 30 LA 1 k o—fir.;e.A\ Srer, c .� Name(Punt) CurrenttM ailing AAddress: ---/�f/(„ Telephone Signature 2.2 Authorized fA�g�ent i /' Name(Pd Current Mailing Address': L P ,Q{ �t�t yci , z-1 Signature Telephone SECTION 3-ESTIMATED CONSTRUCTION COSTS Item Estimated Cost(Dollars)to be Official Use Onty completed by permit applicant 1. Building kci (?2_0 (a)Building Permit Fee 2. Electrical 5IlCII-A° (b)Estimated Total Cost Construcson from(6)pf 3. Plumbing Building Permit Fee 4 Mechanical(HVAC) 5. Fire Protection )� � S. Total-(1 +2+3+4+5) '29, I`�I(Yr° Check Number j, /f777 76 This Section For Official Use Only Building Permit Number Date issued: Signature: Building Commissioner/inspectorsor Buildings Date / /(.VQGJ%�/y[� Section 4. ZONING AU Information Must Be Completed.Permit Can Be Denied Due To Incomplete Information Existing Proposed Required by Zoning This column to be fined in by Building Department Lot Size Frontage Setbacks Front — - -` Side L:. R:IL:, R ,. Rear • Building Height • Bldg. Square Footage Open Space Footage / (Lot area minus bldg&paved • parking) • • • if of Parking Spaces ' - Fill: (volume&Location) A. Has a Special Permit/Variance/Finding ever been issued for/on the site? NO 0 DONT KNOW 0 YES 0 IF YES, date issued:'.. IF YES: Was the permit recorded at the Registry of Deeds? NO 0 DONT KNOW O YES O IF YES: enter Book Page and/or Document# B. Does the site contain a brook, body of water or wetlands? NO © DONT KNOW O YES O IF YES, has a permit been or need to be obtained from the Conservation Commission? Needs to be obtained O Obtained O , Date Issued: C. Do any signs exist on the property? YES O NO O IF YES, describe size, type and location: D. Are there any proposed changes to or additions of signs intended for the property? YES O NO O IF YES, describe size, type and location: E. Will the construction activity disturb(clearing,grading,excavation, or filling)over 1 acre or is it part of a common plan that will disturb over 1 acre? YES O NO O IF YES, then a Northampton Storm Water Management Permit from the DPW is required. SECTION 6-DESCRIPTION OF PROPOSED WORK(check all applicable) New House (fl Addition ❑ Replacement Windows Alterations) i Roofing n Or Doors 0 Accessory Bldg. 0 Demolition ❑ New Signs [O] Decks [p Siding 1OI Other la Brief Description of Proposed Work tot?-ryiwwVerdA S \.0.4 o-x-rn..,�v - 2 \cfvtlS � rici {i...W Alteration of existing bedroom Yes No Adding new bedroom Yes No Attached Narrative Renovating unfinished basement Yes No Plans Attached Roll -Sheet Ba.If New house and or additions to existing housing,complete the following: a. Use of building : One Family '+ Two Family Other b Number of rooms in each family unit: Number of Bathrooms c. Is there a garage attached? PA d. Proposed Square footage of new construction. Dimensions e. Number of stones?_ f. Method of heating? Fireplaces or Woodstoves Number of each _ g. Energy Conservation Compliance. Masscheck Energy Compliance form attached? h. Type of construction Sat-Ac, i. Is construction within 100 ft. of wetlands? Yes No. Is construction within 100 yr. floodplain Yes_-_No j. Depth of basement or cellar floor below finished grade k. Will building conform to the Building and Zoning regulations? Yes No I. Septic Tank City Sewer Private well_-_ City water Supply SECTION Ta-OWNER AUTHORIZATION-TO BE COMPLETED WHEN OWNERS AGENT OR'CONTRACTOR APPLIES \FOR "BUILDING PERMIT ` .as Owner of the subject property 7 'r' C (/ hereby authorize cc* - \ } cx c ' - / \r'?3.bt1 ?v ' r' r CLC to act on my behalf, in all matters relative to work authorized by this buildin�A} s.s permi application. -*C./An Signature of CAvner (ry� Date PCS MruYl�i'o._ ,as Owner/Authorized Agent hereby declare that the statements and information on the foregoing application are true and accurate,to the best of my knowledge and belief. Signed under the pains and penalties of perjury. Print Name '5\'L3,I`i ... Signature of 0 -r/Agent Date SECTION 8-CONSTRUCTION SERVICES 8.1 Licensed Construction Supervisor Not Applicable ❑ Name of License Holder: las&x. JV0.rtccED.- 1 OCi License Number 5 sk- e n Me5o1 I-a0ll°k Address� Expiration Date G 0-44 .aan ,' � it 4Zz o l55 Signet re Telephone S.Recdstered Horns knprOvement Contractor Not Applicable ❑ raa 41 5-- Rl buss 2162 CompanVName Registration Number 5 c t h,. O\ l st2..d0( Address Expiration Date Telephone -\b142c'y 22 SECTION 10-WORKERS'COMPENSATION INSURANCE AFFIDAVIT(M.G.L,c.152,3 25C(6)) Workers Compensation Insurance affidavit must be completed and submitted with this application. Failure to provide this affidavit will result in the denial of the issuance of the building permit. Signed Affidavit Attached Yes No . ❑ 11. -Rome Owner Exemption The current exemption for"homeowners"was extended to include Owner-occupied Dwellines of one(I) or two(2)families and to allow such homeowner to engage an individual for hire who does not possess a license,provided that the owner acts as supervisor,CMR 780, Sixth Edition Section 108.3.5.1. Definition of Homeowner Person(s)who own a parcel of land on which he/she resides or intends to reside,on which there is,or is intended to be,a one or two family dwelling,attached or detached structures accessory to such use and/or farm structures.A person who constructs more than one home in a two-year period shall not be considered a homeowner. Such"homeowner"shall submit to the Building Official,on a form acceptable to the Building Official,that he/she shall be responsible for all such wort(performed under the buiidine permit. As acting Construction Supervisor your presence on the job site will be required from time to time,during and upon completion of the work for which this permit is issued. Also be advised that with reference to Chapter 152(Workers'Compensation) and Chapter 153(Liability of Employers to Employees for injuries not resulting in Death)of the Massachusetts General Laws Annotated,you may be liable for person(s) you hire to perform work for you under this permit. The undersigned'9tomeownee'certifies and assumes responsibility for compliance with the State Building Code,City of Northampton Ordinances,State and Local Zoning Laws and State of Massachusetts General Laws Annotated. Homeowner Signature City of Northampton 212 Main Street, Northampton, MA 01060 Solid Waste Disposal Affidavit In accordance of the provisions of MGL c 40, S54, I acknowledge that as a condition of the building permit all debris resulting from the construction activity governed by this Building Permit shall be disposed of in a properly licensed solid waste disposal facility, as defined by MGL c 111, S 150A. Address of the work: 30"\ siAA S� The debris will be transported by: t-4- 10.ns< t The debris will be received by: 'Qar k? 1aa 5b\ Building permit number: Name of Permit Applicant ?DQikz. Date Signature of Permit Applicant The Commonwealth of Massachusetts —it ,—— Department of Industrial Accidents t 11=r Office of Investigations ^d!=...Jig Congress Street, Suite 100 =iin Boston,MA 02114-2017 ,"'L www.mass.gov/die Workers'Compensation Insurance Affidavit: Builders/Contractors/Electricians/Plumbers Applicant Information Please Print Leeibly Name(Busi,tess/OrganirationttndividuM): BRIGHT PLANET SOLAR, INC. Address: 5 A Street City/State/Zip: Auburn, MA 01501 Phone#: (888)997-4469 _ Arerrryou an employer?Check the appropriate box: Type of project(required) : I. 1 am a employer with_50 4. ® I am a general contractor and I `yq l employees(full and/or part-time).* have hired the sub-contractors 6. New construction 2.0 I am a sole proprietor or partner- These on the attached sheet. 7. 0 Remodeling ship and have no employees These sn}s-contractors have S. ® Demolition workingfor me in anycapacity, employees and have workers' P Y- 9. 0 Building addition [No workers' comp. insurance comp. insurance.• required.] 5. ® We are a corporation and its l0.0 Electrical repairs or additions 3.0 I am a homeowner doing all work officers have exercised their 11.0 Plumbing repairs or additions myself. [No workers' comp. right of exemption per MGL 12.0 Roof repairs insurance required.] ' c. 152, §1(4),and we have no employees. [No workers' 13:.Other SOLAR comp.insurance required.] *Any applicant that checks box 41 must also fill out the section below showing their workers'compensation policy information. f Homeowners who submit this affidavit indicating they am doing all work and then hire outside contractors must submit a new affidavit indicating such. %Contractors that check this box must attached an additional sheet showing the name of the sub-contractors and state whether or not those entities have employees. lithe sub-contractors have employees'.they mast provide their workers'comp.policy number l am an employer that is providing workers'compensation insurance for my employees. Below is the policy and job site information. Insurance Company Name: A.M. GUARD INSURANCE Policy#or Self-ins. Lic. it: R2WC767475 Expiration Date: 12/18/2017 Job Site Address: SGL\ kk Qa-C:t_ic1 �c'esk City/State/Zip: fx\„f .....‘. • _ ,Ile o\C)(e0 Attach a copy of the workers'compensation policy declaration page(showing the policy number and exp ration date). Failure to secure coverage as required under Section 25A of MGL c. 152 can lead to the imposition of criminal penalties of a fine up to $1,500.00 and/or one-year imprisonment, as well as civil penalties in the form of a STOP WORK ORDER and a fine of up to$250.00 a day against the violator. Be advised that a copy of this statement may be forwarded to the Office of Investigations of the DIA for insurance coverage verification. I do herebyettifA un the p 'ns and penalties of perjury that the information provided above is true and correct. o Signature: 6.1A Date: '-- \23 X1'-7 Phone#: (888)997-4469 Official use only. Do not write in this area,to be completed by city or town ofcial_ City or Town: Permit/License# Issuing Authority(circle one): I. Board of Health 2. Building Department 3. City/Town Clerk 4. Electrical Inspector 5. Plumbing Inspector 6. Other Contact Person: Phone It: —,—„-- knpxu0tttstsr � 7 CONST)euCTION NOTES a , , • .wo. .N t StiV.M, WYI- .a,<,enwxo. .,r .r , PnailAl — • uErar rt ..� » o� w M & QrSSMM Ip .au • 4:04110,53tOWIERICUMM.1101flIkeerkti6P0 2+ • c . 'OC'NYANIXSmNS*KIONTR£ 1 ran inowsicaaua nirt _ j • i.,,,,.,,,,,,,,,,,,,,„,,,,,,,,,,,,,,,,,,,,„.„,,,,,,,„,„,„,,,f It i "`"" ..e,w.nr. :�2 .. _. , • .+ - liSi Arxuueemss ` Iat.,v r*:�rw G , . .a" :'hr E _ _ .. t o m AU w cM lin ftgfli"Cet n nwraawrtx cacxsan"-MTh" 05* "b"' m.rexp STREET VIEW GE VIEW 01= fcooir f., . r , s., pg;e - _- o rf Wlgtt Pbnst Soler Christopher CMstopher 8tMr Itly Sheet t 84 Me Street Suds SOB AS .. _ I SNWtOn Street �� Planet s Westborough.MA 01551 ,cNicecra NMhAt�$bn.MA MOO 98&997-4469 tart PIP a -eve6 i4 s I, C.ci,ev 3 011-7.7 M W 67Av= dpoofe . nom l City of Northampton_ e Building Department .�, Plan Review `onmar - _- 212 Main Street ,�--. — — L ROD=_ NEC, � Northampton, MAO1066O Lco T ACCESS PO/NTMP car 1 0 `_� 00 COMPOSITION SHINGLES 0 SYMBOL LEGENDI _ ❑= MECHLUE/PNICAL LUMBINGV �� O=FiUE1QLLMiBINfi'LENT i \\l III 91911111 �1 MAIN SERVICE PANEL \\ l�/ / I \sl�___/////� CHIMNEY ' E10 210 270 270 COUTILITY METER Z"J 270 I 270 270 03 AC DISCONNECT C� 270 270 ® 270 270 OPV SUB PANEL(IF USED) �•• ®� 270 270 INVERTER&INTEGRATED OG D'SCONNECT Aii, A A OPd00OPTIMI2ER(TYPICAL FOR EACH MODULE) � 0 V JUNCTION BOX ROOF SIZED DETERMINED IN FIELD 0 PVMOMELES — —. _ — OCONDUIT RUN IS SURFACE MOUNTED (ACTUAL CONDUIT RUNS TO BE HATFIELD STREET DETERMINE()IN THE FIELD) I SIGHATDDE„„t„2,„2,„•2„ REV oE«Aa,� BtlPNt Planet SOkr w i -a Bakker ^•+m ChmaTml ` BOLS °Plan$ 1T Planet ': 09anMmoYSwn9OMbBt1 onw,2.x$ 2 m,Der ` ® -1 Street304 Hatfield AA Northampton.MA 01060 n. .888-9974489PV2oE nxE - DATE I » P ,retNuwNa A.nM _J NTN- wM�M.1�DM ARMCO SOLAR Too Iw,vxe„nI vved ran� Y [ 4N6M'fMM.LTON WANUMLERLIMIMMMODC I.stomas MAMMY MUM iryfrilivatTALL _ to 446m NUMMI MmCOMPICIFOWYMILAMEWI LEL ,.L. 1101/INALACOWERTVOIUM RATED MKT X POWER T _I xl L as I0. osiAsES- 110011141.11411/010 VOLTAMm II Ie1 �1[ ,la -_ WA mmowur[mmi (L. 1, . a xyCuxe WASUAI 000,0 Jr 0777270.077 W0000 4 ® f, M A.SrIW _. my le V. w Fuss --1 xu,.ru,m MA WWII n,s,ww05110 KM _• • MAIN'HAMM m4l Lal _ I _.. _ _ --_.. BREAKER SIZE • n Hl J ®� ROLM 141/46.w,uwu TER NM]gIIfYYMfIG1pNB L w 1 .Ian w„mono: I .[ amnions. mow soonSao -. .Po.u-Wwr -_. ISI MOW xCRIMP,pnmrrorw MIJIMILECEOINTIOLTAIREWI Ili El !GMAINILIN6 EiKTRON.116111f,V a,d INTEGRATED DULE&RACKING GEM METHOD'UNMc SOLARMOUNi offmaxurrm,irw ®L 00. MOTALI A SUWIEMENTAI 04IMMENNE FlICTROM Moan err 10 BF ON 00 MDC 1 1711 TRAAAC] MOOUIESJOFTFMIZERS IN A STRING co RED waxEN •M/ �'�+ LI LC °�r°< p ® CALCIMRMS- T EXIST.!ASP E,MVPME Maw- I F.F.`"�uPEaF»reMwINaERSINBMLS © A A ©omm _ w =w oMpDMLESD.nMTERaN.3rRND +� m Q E o . .. off 1SE , - LIMIMS M 1 LI 1 ■ ti Ma N ■■,. . on. L — .�— -- — . - L2IL 1 35x. wL,xrxR wAK 3,w M lUBL . w �,T F w © VISIBLE BLADE �IELECTUTILITYMAX'ern..CURIUM 0 LpnaalEGRID _ii-- __-270W ..-AC1wi I WY POWER znw ATIUTo MACCESS 24.7 a MOTE O -... _-. 4UIPMENTSCHEDINE 4 - TTv_c°MOCON NR 2C[AW I •0FC Or CcwuCrM T/» [ a][pwal IOr RS xpun SRF „ l.W SOLAR npn MANUFACTURER PART NUMBER NOTES NUE ., Win R :sou AIR SOLAR W MODULE 12 SUN EDISON F.;RIES Imry SUN EDISON MYRIES 270W QUANTITY Ii - TIWRU M 1 MEM AIR mL33 BM[_ SOLAR Iv DuLE128IW 3ry" SUM o-s0004 uSv SUNEwvx f-xPI[vmw OUANmv 1, Ism fm&88 4 ]MI IxgRrtR _ »,m EDGE SFSCws.15 _ _ SOLAR EDGE ssswnus QIAANTml mw .weM la PA FUrt -OPTIMISER --- UNIRAC ASI OIMMm 22 -- _ RACKING .1-BOX _ EMIT(X _ E9tl1 icoNoucTOR CNCIMrIOM I ALCONSEETOM M[ j OROUR IR -- UNuc SOLAPIrwuNT MONAD TO wy%AIL TOI BOX SILO.111=15611 4)Iii 1u.15.254 DESIGNED FOR LEEMAVA NM SOW SUB-P ECT xTMEM10 INV REEFED ER comer Ma .NAW6.3L gLTA6[pA01. IxwsSHUTDOI INTEGRAL imWERr[R INTEGRAL 10 INVERTER T,D.,4edO lbl.,rz 6310.1.5011.101ESMT =M, SNAIL EXTERIORCONDIOS zl Rmlpixlnwxn mwEpc[ - NEMA uTOlxvEAnn T6neyCl m6„/m5-nssv nss./nx-liae wxvluvEwnERvma 10 4ClunUE l DISCONNECT EQUAL malxa,u0V.IDAzgx ,aAMINO..133ahos.nu. 27w.3s. mnrLS SIGNATURE 0.10c0 A a[ am Planet SYTEMSIZE 6MSS MSS DATEOEscwcnox Bright Planet Solar 4 Ha Christopher Bakker • 69 Milk Street Sidle 308 RISER Nlestbopuph,MA 01581 CONTRACTOR LICENSE LATE 0 30 42011 _- _- 304 Hatfield Street Northampton,MA 01080 DIAGRAM 868-997-4069 DATE DESIGNER Ln RNA!. — — PV3 NOTE PLAQUES SMALL BE ATTACHED TO THE SERVICE EQUIPMENT r ■ ■ /S t WITH POP RIVETS,SCREWS,OR APPR VED ADHESIVE 13 PLAFARb ♦ ■■`�/!■( ■(/�/�j■ ���V■■ 01 OOAnON.MAIN OREAVFR.UP"TEM' Q g {'}l] LOCATION MBP tan 1at2'7TEXT CAUTIONYSTEM SOLAR CT ELECTRIC i' wean PxN1YA V IA1I Po n., iiicm 1 PHOTOVOLTAIC SYSTEM MOPPED ( 1 SYS1EM CONNECTED AND d titerft� r IMOD Baams6uTbowN ` POWER TO THIS BUILDING IS ALSO �' E aeaGrzED Cebw ee4MmBe19etlgurA I '1., @. ,l SUPPLIED FROM THE FOLLOWING 1 Y C– k mats*-Adxe<mmrosontmro �IOGT!ON fN ER R 14 PT(0T9 'ITEXi� 10 LO ATIo MAN BR£ ER.14 P1 ,P 7 f T SOURCES WITH TDO_+ � DISCONNECTS AS SHOWN 'I La39303sma araeRk 1 r scaiBwrst vel r RAPIN SHUTDOWN DISCONNECT UTILITY AC DISCO —EXISTINGMAlN j ' �+s SOLAR INVERTER SERVICE '�4— _ _ k , L BENBLIE:EWSRES I �` ___ 6 — k & DC DISCONNECT I ENTRANCE 1.0 LOCA/ION AC DISCONNECT "APT{0]95'ITEXT Ig Lpppllpft BGOI@COOR.NVPRTER.HPT M.:96')TEx - wnvri I�BCtwNftt [hU11pN 401AN PV Ni[gUl1Yti11M1=11 I tick OW CT I OR UID]TY OP(RA TION 1 d B I 1 1 ®LOCATION SUB PANEL IIF USPtC 14P"fo IWj TEXTI - 1������ I 111111111 a:- V P.nnu, i- SOLAR PV ����\L� r k e• ARRAY ON ■■ I 1 LOCATION MSP PANE PT(OI.MT}TEXT ROOF 'll- ,,,_ • _. HATFIELD STREET • k -- -- ---' m-ssrto t.;;;44; ;I.. PV SUB OF USED} FOR ILLUSTRATION ONLY NOT ACTUAL MSPIT LOCATtONIJ@O%esl 14PT(0 195 TEXT GAIN SERWCE PANEL I T 1 j a�I i 1 IC)PLACARD IV L--J j - 'L. _ R' k AC 1 w (�} I aSCON ECT 0 Lf 1 BOB i , ioLOCATION MWNPVBREAKER 14 PTO 0iGGApON SUS PANEL{if USE01-14P7(01951TOD 1 ID MVERIER OF USED/ f ea z SOLAR ONLY 12 1 ED � I a � I I of I � I — 2 k k { a 2 I 1 1 i I, • Planet m�o-nam Bright Nene< « 1 T C CEM a� „- I Cr! Sr .,�- -- ..._ �x:P,. .._. N r94 Ratm.Mnowao 1 & Nam& 11 Y WeM,Wlalp, MA01581 III __ Table R802.5.1(2)-Continued • - Gunk MOUNT ATTACHMENT LOCATION • RAFTER SPANS FOR COMMON LUMBER SPECIES M/MIMUM OVERHANG(CANTILEVER)IS 19" (Roof live load=20 psf,ceiling attached to rafters.L/A=240 MAXIMUM SPACING OF ANCHORS(FOOTINGS)Is 4e DC FIELD VERIFY EXACT LOCATIONS OF STRUCTURE MEMBERS DEAD LOAD=10 psf DEAD LOAD=20 psf RAFTER 2x4 2x6 2 x 8 2x10 2x12 2x4 2x6 2x8 2x10 2x12 SPACING SPECIES AND GRADE Maximum rafter spans* (inches) (feet (feet- (feet- (feet- (feet- (feet- (feet- (feet- (feet- (feet • - inches) inches) inches) inches) inches) inches) inches) inches) inches) inches) ' Douglas fir-larch 55 10-5 16-4 12-7 Note b Note b 10-5 16-0 20-3 24-9 Note 0 Douglas fir-larch #1 10-0 15-4 19-5 23-9 Note b 91 13-3 16-10 20-7 23-10 1 Douglas fir-larch #2 9-10 14-4 18-2 22-3 25-9 8-6 12-5 15-9 19-3 22-4 Douglas fir-larch #3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10 YiarT--4r—.- -1 - - 7C-141-1.4. Him-fir SS 9-10 15-6 20-5 Note b Note b 940 15-6 19-11 24-4 Note b s-÷ . i •---, • Him-fir #1 9-8 14-11 18-11 23-2 Noteb 840 12-11 16.5 20-0 23-3 1 • Him-fir #2 9-2 14-2 17-11 21-11 25-518-1122-0 i_• . • + B5 12-3 15-6 F. •+ • i • • • +• • +• • 16 Him-fir #3 7-5 10-10 13-9 16-9 19-6 6-5 9-5 11-11 14-6 16-10 I I Southern Pine SS 10-3 18-1 21-2 Note b Note b 10-3 16-1 21-2 Note b Note b F: • •I . • 1 -_ }--. • :{ Southern Pine 41 10-0 15-9 20-10 25-10 Note b 10-0 15-0 18-10 22-4 Note b • • • • • • ' Southern Pine #2 9-10 15-1 19-5 23-2 Note b 94 13-0 16-10 20-1 23-7 1 •_ _ • 1 Southern Pine #3 7-11 11-8 14-10 17-6 20-11 6-10 101 12-10 15-2 18-1 F• • + • i • i • •i, , Spruce-pine-fir 55 9-8 15-2 19-11 25-5 Note b 9-B 1410 18-10 23-0 Note . y •• • Spruce-pine-8r #1 9-5 14-4 18-2 22-3 25-9 85 12-5 15-9 19-3 224 • ROOF A Spruce-pine-fir #2 9-5 14-4 18-2 22-3 25-9 0.6 12-5 15-9 19-3 22.4 Sprutxyinealr #3 7-5 10-10 13-9 16-9 19-6 6.5 9-5 11-11 14-6 16-10 Pholowliak Dead Load Statement 21 x e'RAFTERS/TRUSSES Tolal Ares Of Army- 338.Oes011 *LENGTH INDICATED IS TOTAL UNSUPPORTED LENGTH. 16'ON CENTER Array Gross Weight=1LV7.551bs Dead St Raug=a.s 9 ft A framing plan is required onlyif the combined weight of the PV arrayexceeds 5 pounds per awing Structure,Framing.2e (ft 1e'oe square foot(PSF or IbsRP)or the existing rafters are over-spanned.The following span tables from the 2013 International Residential Code(IRC)can be used to determine if the rafters are over-spanned. For installations in jurisdictions using different span tables,follow the local tables. • Bright Planet Solar SIGNATURE oawsc smn REV DATE o[scwenox Christopher Bakker Structural S aSk Planet 69 Milk Street Suite 306 srFu alis :4:7 wwr — — 304 Hatfield Street Calculations P Planlet • Westborough.MA 01581 CONTRACTOR LICENSE DATE Tama -- - Northampton,MA 01060 ' —J 888-9974469 DATE DESIGNER n.,a.,•. -- - PV5 F - _ Z50 f / ins ROOF RIDGE ET RDS QUICK MOUNT DIMENSIONS . 1/4‘I ,�RAc„ICLUDDPONENTS F o 0 NOTE 1 1 0 COMPLIES WITH ICC ESR 3744. 1 © _ O ll O � 12 00 1.30 An dimomo... . • 150 n � 3.00" O I 300MINIMUM SEALANT APPLIED UNDERNEATH FLASHING ITEM DESCRIPTION GIY EMBEDMENT= FLASHING.12"X C. X 05065G52 MILL 1 _ OBLOCK CLASSIC,A360.I CAST AL.MILL 1 HANGER BOLT,PLAIN CENTER 4 OY x 6.MOSS 1 E O WASHER SEALING,NCID%WOOD.EPGM BONGED 55 1 NUE HEX,5'1618.UNC-203.We 33 2 12.00 WASHER PLAT,ER 5/I&x1 XI"0 x 1A'EPOM 1 WASHED.FENDER9.5 ID ID 04184 SS 1 WASHER.SPLIT-LOCK,S'16'1010055 1 ROOF COVERING IS OPTIMAL SPACING FROM EDGE AND IN BETWEEN CLAMPS COMPOSITION SHINGLE OVER PLYWOOD [LANDSCAPE PANELS tr PORTRAIT PANELS-.1\ CLAMP RAIL SOLAR MODULE B" 2-1p- e" x •M MODULE PI. • x• 00••• •11111111,,...„ ... � 16" le 1 y- prill CE MODULE CLAMP SLIDING N L-FOOT B _.] i OUICNMOUNT HANGER BOLT RAIL HANGER BOLT COMPOSITION MOUNT NOTE.shall be el VV,FLASHING least s InOpa from arlY SEALANT APPLIED UNDERNEATH L FOOT OBLCCrt siaa Bright Planet Soler �� Planet , 69 Milk Street Suite 308 ruRc sPn ursu 5 wawµ REV DATE DESCRIPTION Christopher Bakker Structural Westborough,MA 01581 cwlrracroa ucexs[ 304 ptonE Street A010 Attachments 086-93]-0089 DESI 1241017 -- - - NGMamplGn,MA 01060 DATE UEM NER n.5'.e. — — PV6 It.. " -. 1. r 4.. ,+ ' : \\*%...".:‘ cN , /it':, rs •1 westbcftu4 Planet -... Astvzrrso,„, airaittimmt_ ./". z se A Po 8@&9974%g MA 01581 f __,4_, eresasThwamst �',Qo . uc$th Ba tichr,. rBakker Northampton MA�t� Pr°Per&tNes Py SILVANTIS' R-SERIES : €1SunEdison 270 W TO 290 W 60-Cell High Wattage Modules SunEdison introduces the next generation of high nine min nhe solar modules based on innovative Continuous Ca ICCr) w.- monocrystalline cells with PERC tech e:magy. The SJvanIls ri-Sen es defrvers the highest feyels of efficiency and durability: providing homeowners yeah the game quality and pedor mann - SunCdisods utility customers enjoy, gag,optimizing roof 81, ocerali system sire and installer productivity • SunEdison i,a leader in eine scan solar systems • • with Over Iwo and a half-million Silva+itis modules deployed hn home of the worlds harsiv):a dimaes and roost remote locations. This experience, coupled with over 56 years of expertise in silicon technology and innovation enables SunEdison to design and produce highly advanced residential 6nlarsol Utiolt5- 'C?^n SILVANTIS ADVANTAGE • 17.7%module efficiency oath positivepowertolerance Ilk • PID-free:compatible witbanstamedess and muibMPFT inverters • Higher return on investment with more watts-per-module • Reliability tested beyond international standards • Uticy-grade manufacturing:ISO 14001,ISO 9071 and 100%EL inspection QUALITY& SAFETY ROBUST&AESTHETIC DESIGN • industry leading PID test conditions • teacd°nodded corrosion resistant aluminum frame • 98 hours.&5C.85%relativehuminity.—1kV s White back sheet.SE-R2KOC-3y • IEC certifwtl by 70v SUD. • War*back sheet SE-R2xxK2C-3y n 61730 to ensureelentrcal safety • Low glare anti-reflective coated AGI tempered glass . 60068-268 dust ant send testing for desertcNates BUNEDISON WARRANTY n 61316 i0rlg•t6On Iner°tlee in e sanely of climates ircludingsnow loading uytosoo pa • 25-year mite warranty for materials and workmanship and bail testing for assignees 5250 RWDC n 61781 Level I and Leve/6 salt mist corrosion resistant • 2:Wesr linear power warranty at STC for mane regions a Year is se 5%of rated power • 62716 ammonia testing for aaicugorei cairn/Meets n After year h 50.7%rated power degradation per year • Manufactured to AOL 04 Lessee quality and tested up a,3x beyond IEC standards • GSA certified to'41703 for 1,000 V systems in the US and Canada nil • MCS cereffed by 8ABt for the UK I lc' SvnF 1%£i a hum SV F-0 l(Mar WatrM$ cci tit, 0000z 1 - � �❑ v , , , •:1t : cels a YSun&iison' SILVANTIS R-SERIES: 270 WTO 290 W PHYSICAL PARAMETERS H-SERIES SOLAR MODULE DIMENSIONS mm[inch] Module Weight 19k mmx999 mm mm - CogTYModulWe1gM _ '. 1ERC - Number - .I 6ERC on 65z mgmttysYtldm - u__., _. Number of Cel! - - 60 ��-f Frame Materiel Black Anodized Aluminum Tempered ARARC Glass Thickness 1 32 mm7 reo•no nu TEMPERATURE COEFFICIENTS AND PARAMETERS' -- I m eratmg ten Temperature—MOUS I 40C C JTemeratureC of nt of Pma - 44%/C I\cO0 1Temperature Coefficient 1-0.32%/C 1 Temperature Coefficient of Ise -905%IC Operas gfiemPerature _ 1-dOC to+85C Module Dimensions �Te. Maximum System Voltage 11992 v(UL it IEC) L A-9_903907 6-iy!,tt[65 31 Ravers°CuneRa -.._. 92OA Maximum Sanas Fe15A C-5012.01 C-3011.191 Pmax Production Tolerance --Rating [OW to+S W Mounting Hole Spacing Junction Box Rating -- II/67 C-950[324] F-994139.1] IEC 61130 Application Class A Module Fire Performancet 1pe2 L- 11, Length (indicatedin mo33 Sj FreResistPackaging rkeRaa ClassmC L- 1,000 t5121?model 39,�8Y Packagm95pacifwafipns 20 module perpallet 0' L 1,3001612P,model 3'JI 520p modules per 40'HigM1-cube container Wind and Snow front Load _--- to24Pa Pe Wind Back Loan --- 2)00 Pa Reduction of SIC efficiency from 1000 Went <4% IV CURVES AT MULTIPLE IRRADIANCES{2S CI to 200 Wfm2(Relative) STC ELECTRICAL CHARACTERISTICS' ,g Model8 — R270 R275 RR280 RM8 R290 R270 8275 8260 RIBS 8290 8 (e.g.RDVC¢C-3* I CzC CzC CzC CYC CzC KYC K2C KaC KzC K6 L '� —lima wm' Pa d 270 275 280 285 230 2I9 275 280 285 290 - _. __ — rm, Power4 a ..__.__. �.. x Grccrw Pottage ]eb ago 2 393 393 �388 BBs--3B7 38J t _. yam m Short-Circuit Current 910 630 945 950 955 9.1p 920 930 940 9.50 —pXw,e, Ise(AI , 2 — -Module Efficient/3°A) 1 164 7166 17.1 77451 17.7 164 1169 17.1 fVQ } 1L7 11 Maximum Power Point 315 316 . 317 3191 31S 315 316 315 . 317 3L1e _ VopageVmpP08 0 s i* sas to as 40 Maximum Power Point 1 8 58 I 812 I 884 896 9.14 638187218. 9W 9.14 voltage WI • ImNOCT ELECTRICAL CHARACTERISTICS' 1 IV CURVES AT MULTIPLE TEMPERATURES 11000 Wim'] Mod&# -_ 8220 8225 R280 PM8390 8270 R 8280 8 275 265 R290 10 {eg_F22oreze- y)' C2C tic C2C CrC { CzC Keel Kee Kee �C KZC Rated Maximum i 1973 20.9 2046 206.2 211911934 1967'.2003'2039..&15 8 Power ernes OV) Open un Voltage 355 356 135.7 ] 388 1 35S 1 r 353 1355 735.6 357 356 q a - _,sc Short-CircusCurrent 1 742 745 247 L 749 751 728 732 735 738 741- o —arc /so(Ai e Maximum Power Point 284 288 ( 291 1294 { 296-28.21 22.61 28.97 292 ' 295 < .- — ---nc Voltage VmpP08 _- I Maximum Power Point 694 ' 697 703 7099 7.15 684 688 693 '. 699 705 2 -- - -- - Currentlmpp(A) Listed specifications are subject to change without prior notice. p - _ EIDpe.'F1 1 .e.ac'75,5 . ,. , i.'ae 0 5 IC ,S De 25 30 a5 40 WNgeM eerier L IroreAIR/ /WO WNr.AM I.6 )5t reel eters rnay • V°,?' 53 MAAlv:evro - a(o/eancer)yet(.07 pe PIMA'Fvuu f0ee.ra i?5ired r r PP O.marre.r^ JM1eJro ne_t O.0.coedlow Gra ter01 lei,& srly)se,(sfr'�v 7710 N to -5W O 'Cf r C 31 [i„µAlk S4 8: 38 39 1 41rC H4 'Mr 1l enZ)a • ,on mr: ,k2.0 M uex�x ... �< A tla,;e3- IX:wen NOD Qer e rVieS ,.nca n0. APMMIli,CAM77011(1.77CsPs:8IX7.vin/.20C, AM I5 4 m:rNb For more information about SunEdison's Silvantis modules,please visit www.sunedison.com or 2 1 Lterc IUS-g 5 < c4 A Sr E0.' t Td'N A wtl 5r,E d l c' MFII :I loon m,a 1.r 1 s. pdM C ICearai- l_L d '7" c lie f C. ..C.r id - ed Sear - . . - Sol arEdga power CC Module Optimizer W Add-On For North N P300 / P400 / P405 America c� Q C jf C.L. sF .:1110 ti' s _ I 6 LMpv.e s lir �r Ftn sz 4 # —,-,4 4.(1-044„ ` Flexible °frnoddu(e • • tr ,� a,;a 4. Next t snstallax n with single m 4WfzetP smatelt m 4la[{tglti8 �` `� m:.re,�, x .f---.:`� � ^a� `� � y� c" olt 41. Module-level generation°fiaee shutdown with module-keelmonitoring lvrfCt�>kp � . ..� ` C• ami °; down for Installer and fi autoe Ti- USA refiBflkNr'Saf...y GERMANY AtY FRANCE - JAPAN - CHINA - ISRAEL ' AUSTRALIA WWW soiaredge us solar- • • G SolarEdge Power Optimizer Module Add-On for North America P300 / P400 / P405 0 — P#D P400 P405 _ {rorsa:xp=chats) tm �x rs9s<m moaulna (for mm film mwwe:! INPUT Rated Input DC Power° 300 400 405 W Absolute Maximum Input Voltage 48 • 80 12$ Vdc (Vac at lowest temperature) MPPT Operating Range 8-48 8.80 12.5 105 Vdc Maximum Short Circuit Current(Ise) 10 Adc Maximum DC Input Current 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED i0 OPERATING SOLAREDGE INVERTER) Maximum Output Current I 15 Adc Maximum Output Voltage 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF} Safety Output Voltage per Power Optimizer j 1 Vdc STANDARD COMPLIANCE _ EMC FCC Part15 Class 8,1E661000-5-2,IEC61000-6-3 Safety F IEC62109-1(class II safety),UL1741 • RQHS Yes 1., INSTALLATION SPECIFICATIONS Minimum Allowed System Voltage 1000 Vdc Pxxx-2 series 141 x 212 x 40.5/5.55 x 8.34 x 1.59 mm/in Dimensions(Wx I_x H) 128 x 152 x 27.5/ 128x152x35/ 128x152x48/ Pxxx-5 series 5 x 597 x 1.08 5 x 5.97x 1,37 5x 5.97 x 129 rnm/in Pxxx-2 series 950/2.1 gr/ib Weight(including cabiess IP%%MS series 770/1.7 I 930/2.05 1 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated;MC4 Compatible Output Wire Length 0.95/3.0 i Li/3.9 m/ft Operating Temperature Range -40-485/-40-+185 'C/'F I Pxxx-2 series IP65/NEMA4 Protection Rating Pxxx-5 series P68/NEMA6P Relative Humidity .0-100 eava SR onwa of the mocks ...Wtluro of ap le, 5M now,miemaalbwa PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTERI'f .__ .t_ Minimum String Length8 10 18 (Power (Power Optimizers) _....__ . _. Maximum String Length t (Power Optimizers( 25 25 50 Maximum Power per String 5250 6000 12750W Parallel Strings of Different Lengths Yes Or Orientations II nem Mue.a++nxawm w_>IW!>amAc*iop'ho.,„,. sg -... CE Tc IIIII sna8paielosmmm 13b8Si-Nl±.5pNG1H3N13N 3N1-V!)VN1Sgb-bNIHJ�Nbdbt- `_'• t ZT•j/SNV. 3JNby3-gbll-ANVWNd'J.VSO okkuo u/ alsei j0 4oirmg k a uaya_Ieuopd0 uo • • ,,. 01SJDAUO)3 0 S1 alquaasse-a d t '' *w ,- r .z ssaleur�,ro oRellgsul a8glot pa '..44.'"4'-' w. ra . y k� £ -a;' ' 7ega 3a 447 u +oop�n0 E ` � ,... � � u6��y'�C.+4ASesp�rempum ul�lm l .. ve.4. ,;a , NI yiNus am i ,poin '...!em::,t3 "T z�VW�� yam ku 'y`�"•!I m. x "k 1� a a( c$ � t �. ,. . I ri I I , allemmist I m sn y00093SSn-b004tl3Slsn-b TJ Sn b00033S/ 000w S/ sn eooae3s sr�a000s3s saapanul asey a souaiu y tnJoN Jod CO d l�u•0 afip3Jelos . ae'os solar - se = Single Phase Inverters for North America SE3000A-US/SE3800A-US/SE5000A-US/SE6000A-US/ SE7600A-US/SE10000A-US/SE11400A-US 1SE3000A-US 1 SE8800A-U5SESOWA-08 SE6000A"US 5E]60DA-U5 SEIWWA"US j SE33499A-US OUTPUT Nominal AC Power Output 3000 I 3800 5000 6000 I 7600 9980@2089 11400 VA 1900012450 I Max.Afr Power Output 3300 415E I54o0@2U6v 5000 8350 50800@20893 121100 VA 5450 @2496 10950 9240V AC Output Voltage Min:Nom Max"' J J 183.'208-229Vac AC Output Voltage M n Num.-Max" J JL J / J J J 211 240 264 vac AC Frequency Min:Now:Max:" 59.3-50 603 Hz 24@208948@208V Max Continuous Output Current 12.5 116 21@2409 25 32 I 42@2409 4]5 A 6101Threshold 1 A Utility Monitoring,[ nding Protectfon,Country Configurable Thresholds Yes Yes INPUTMaximum DC _._ Transformer-lezyngroundeu Power(STC) 4050 SSW 6750 8100 10250 13500 15350 I W es Max.Input Volta&e 500 Vdc Nom-DC Input Voltage 325 @ 2089/350 @ 240v Vdc I 165 @ 208V 1 I 33 @ 208V Max.Input Current' 95 I 13 18 I 23 345 Ady 155(92400 305@240V Max Input Short Circuit Current 45 - Ado Reverse Polarity Protection Yes .. o.n....ut s lao..____. Grouu&Faultlsoladon U2tuCfion 600k48erwlHvRy Maximum Inserter Efficiency 9]71 982 983 98.3 I 98 98 98 % (ECWeighted Efficiency 9i5 . 9 8 4]@2089 96@24gv 97 5 97 5._. 9]5@2409 4T@2�V 975 --.g.._. 1 , Nlghitmme Power Consumption 325 <4 1 W ADDITIONAL FEATURES Supported Communication Interfaces R5485,8430 Ethernet,llg6ee(optional) Revenge Grade Data ANSI 0121 Opfipnaiva Rapid St widows-NEC 2014 690 12 1 _ _ _ _ Yes STANDARD COMPLIANCE Safety Utl741, - - UL1699 . 8 CSA 22.3 Grid Connection Standards IEEEISO e s FCC parttis dasse INSTALLATION SPKIFiCATiONS AC output conduitsize/AWG range 3/4"minimum/16-6 AWG 3/4"minimum/8-3 AWG 7 DC Input conduit size/P Of strings/ 3/4"minimum/1-2 strings AWG 3/4'minimum/1-3 strings/ AWG range 1416 AWG Dimensionf with Safety Switch r 305x12.5x 10In/ (H(Hatt/50130305)(125x 7.2//75 x 325 x 184 775 315s2606U We€ght with Safety Switch 512/23.2 54.7?24.] 88,4:401 1b/t"$.. Natural ection Cooling Natural Convection and internal Fans(user replaceable) fan(user _ _i.replaceable} Noise <25 1 <50 deA Min_Max.Operating leBlperature _13 to+140/-25 to+60)-40 to• Oversion av1111Pbve') Range Protection Rating NEMA 3R rcglav gs pia onm e high*want mead.the -w rMMnn in spoon mlfu wlcwd. tt enielei fi-103,'WOW in 5Ea NA-UWO2NIVR:, aom..wsllm Svae uw.wNNun irorMeow mro1er57taOAusIDo1NMIu:. CO C > RoHS MI 41 1, p 1 1,11L1 } i GreenFasten"GF1 — Product Guide Cut Sheets: GF1 I,'• I. iy At tA Pro- "Its las Nt. • to 1 W t1 0 H SECTION A-A 877-859-3947 EcoFasten yid 7 � `� 1 4'p EcoFa5len Sol p�Mutls are pSmo(ecctkeiaicontentprotectedunder copyright5Msrts21199114 3.1 byibe following US Patents 8.151 522 82 8 153]00828,181 398 82 8166]10 B26.146399828209914828 245454 B28P2,174 82822555782 GreenFasten'" GF1 — Product Guide Cut Sheets: GF1-812 l I< } , t air 8" 4X R8.. F 1/32 hH # r 08, 1 06. A 5/64 co 5 ILt ++ 16• DETAILSCALE A i•--1 SCALE. 2:1 • t4 Finish Options BLK= Matte Black MLL= Mill Finish i 3 j.t' EcoFaste Solar59 products are proteen cted by the followr All content Ongib SePatentsr8151522rB28'19)00 828181 reserved E92/14 B28.186710 B28.106299 B2 8 209 914 B2 8 245 054 82 8 272174 B28225.557 B2 32 *:4P4. Stxtl^ ." 1 .z a . 1 f I�; . 4 1 Gre®d Itspent6F1-PrPdndufLj&dede Cut Sheets: Bracket Options - CP-SQ-Slotted %°,I .f I i, t- I,50� 1 so 7_ 38 zoo TH loo �I 00 0 0-38 00 T 0.50 1 1 N/ 0 0.88±.01 X 82° 9 L 2,00 y� n s /14 cR8Solar Ecocssten Solar content protected 8/515221 All 153.700reserved 818 398 B2I 3.3 ¢ 5 't EcoFasten SdarprMuc6 are protected by the following U.S Patents:6.15L522828.153]90828]81398828166]13828.146299828209914826.2452548282]2,1]8B2 8 225 557 P s ..13135;,5',, a it GreenFasten'" GF1 – Product Guide Cut Sheets: Bracket Options-SCL-101-3" �r, I II 3/8" r � r (110 A 46 SERRATIONS `TJ v ' Ir �, t3 f 1 t,'{ 1 1 R1/l6" - 1 7/8" 1/4" Lo — 3/4" r_ 1/16' R.005 111. R.O10 ailk/ \ 2X R.O1 ii 4 \ 4 60.0 \ \y„.„.------ { ° 3/8"-.002 8' N/ 0 7/8" X 82° DETAILSCALE 3a ^, 877 859 3947 EcoFasten Solar'All content protected under copynght All rights reserved 8127114 3.5 id - EcoFesten Solar products are protected by the following U S Patents 8.151522 B28.153.700 B2 8 181 398 B2 8 186713 B28,146.299 62 8 209 910 B2 8.245 454 62 8.272.174 B28225557 B2 Pi P j Y p11 ; ' I r, t ! };, GreenFasten GF1 – Product Guide Cut Sheets: Bracket Options- L-102-3" 'i 2X 3/8" A 46 SERRATIONS M O ‘...__IV N IL ' If f \ N 1 7/8" — 15/16' R1/16" 1 7/8" i., — 3/4" —I 1/4" Eo ,�. q . 1— 1/16" r ;o1111 (_Jr,\ R.005 . 1 \ R.O10 2XR.01 -1 60.00° + 006 03/8" 002 1 1/8" \/ 0.875+.010 X 82° DETAIL A SCALE 3 : 1 .. ll R rights 877-859-3947 EcoFasten Solar the following protectedngUSPatents .151 522 8153.700reserved881 988/27114 3.6 „ EcoFas[e 5lar pmtlucis are protected by 0ebllow ng LLS.Pa@nK6.151522B2 8,153]00828181 X96 820,166]13 B2 8 146 299 82 6 209 914 B2 8 245 454 B2 2]2.1]4 B2 0 22555782 4 ' nM isP'. }^BOLT LOCATION \ 2 . 16 }"BOLT LOCATION J I. U N I RAC / PRODUCT LINE: SOLARMOUNT ` DRAWING NOT TO SCALE 1 <wmraoucCOMPANY ALL DIMENSIONS ARE NOMINAL J TA DRAWING TYPE: PART DETAIL a 1411 BROADWAY BLVD NE r ALBUQUERQUE NM 87102 USA DESCRIPTION: STANDARD RAIL PRODUCT PROTECTED BY ONE WWW.UNIRAC.COM OR MORE US PATENTS. REVISION DATE: JUNE 2014 LEGAL NOTICE SHEET T f lig' 1 W `i� B CLAMP 30mm to 32mm Module Thickness C CLAMP D CLAMP (1.18'to 3.26') 33mm to 36mm Module Thickness (1.30'to 1.421 38mm to 40mm Module Thickness (1.50'to 1.571 21 1AIL] li.*1.. 16 1 K CLAMP F CLAMP 39mm to 41mm Module Thickness E CLAMP 45mm to 47mm Module Thickness (1.54'to 1.61') 50mm to 52mm Module Thickness (177'to 1.851 (1.47"to 2.051 12 �` t Z m lir TYPICAL END CLAMP DETAILS w I �� PRODUCT LINE: SOLARMOUNT O LINIRAC ,� DRAWING IMENSI NS TO SCALE 1 �� ALL DIMENSIONS ARE NOMINAL J O >NILTI GROUP COMPANY DRAWING TYPE: PART 1411 BROADWAY BLVD NE a+ ALBUQUERQUE.NM B7102 USA DESCRIPTION: END CLAMPSPRODUCT PROTECTED BY ONE ± OR MORE US PATENTS WWW.UNIRACCQM REVISION DATE: FEBRUARY 2015 %. ...iLEGAL NOTICE SHEET BONDING SPLICE BAR S O O O O A , ____ 16 5. ,..._ #12 X1 SELF DRILLING 5S SCREWS INCLUDED TYPICAL SPLICE BAR DETAIL I RE TYPICAL EXPANSION JOINT DETAIL USEDOTE THATT EXPANSIONOXPA OJOIS N. USED AT AN JOINT. THE SPLICE BAR DOES NOT BOND ACROSS AN EXPANSION JOINT. �� PRODUCT UNE: SOLARMOUNT DRAWING NOT TO SCALE U. UNIRAC ALL DIMENSIONS ARE NOMINAL 0 GROUP m nnILTI exvwnwv DRAWING TYPE: PART&ASSEMBLY ` 1411 BROADWAY BLVD NE E ALBUQUERQUE.NM 87IO2 USA DESCRIPTION: BONDING SPLICE BAR [PRODUCT PROTECItD RV ONE OR MORE E US PATENTS {n WWW.UNIRAC.COM REVISION DATE: SEPT 2014 LEGAL NOTICE . SHEET ` f r it I `l LL i-Sb - I c I-16 x IT BOLT � t FLANGE NUT LIIIIIIII1b - I E L FOOT -m- 1- -0- • 2' SOLARMOUNT LIGHT ON L-FOOT f_7 'H! MAXIMUM HEIGHT 316 MINIMUM HEIGHT 216 r I! t SOLARMOUNT STANDARD ON L-FOOT t Ina f 11 MAXIMUM HEIGHT 4 '11I1 I MINIMUM HEIGHT 3 SOLARMOUNT HjfD ON L-FOOT i MAXIMUM HEIGHT $- Ili MINIMUM HEIGHT 16" �`� '• �r[I___ iiii LNOTE: LFOOT CAN BE INSTALLED IN TWO ORIENTATIONS. PLEASE REFER TO INSTRUCTIONS IN THE QUICK START GUIDE.• (�{� ( Y •••UNI RAC PRODUCT LINE: SOLARMOUNT DRAWING NOT TO SCALE RIRI RALL DIMENSIONS ARE NOMINAL EV A HDI GROUP COMPANY DRAWING TYPE: O PART &ASSEMBLY Qc 1431 BROADWAY BLVD NEI ALBUQUERQUE.NM 87102 USA DESCRIPTION: L-FOOT PRODUCT PROTECTED BY ONE OR MORE I US PATENTS In WWWUNIRAC.COM REVISION DATE: JANUARY 2016 LEGAL NOTICE SHEET t 1 BONDING SM MID CLAMP BONDING SM END CLAMP J • \ 1. T 84 1_21. v 1 ■ I H 116 16 `— 1 VARIES- REFER TO 111 ta- +-a SHEET SM-PO4 HI-- 4 + —6°1r— a END CLAMP`'. 4 liCilliii.H.41-11411111°P 160.4 MID CLAMP 44.41N. Z NNies .I` f \ t 1 PRODUCT LINE: SOLARMOUNT 7T9 DRAWING NOT TO SCALEUNiRAC ALL DIMENSIONS ARE NOMINAL n *HIM GROUP COMPANY DRAWING TYPE: PART &ASSEMBLY Q 5411 BROADWAY BLVD Ni ♦ AI3UQUfaput,RN s71O2 USA DESCRIPTION: BONDING TOP CLAMPS PRODUCT PROTECTED BY ONE WWW.UNIRAC.COM OR MORE US PATENTS Vi ♦ REVISION DATE: SEPT 2014 LEGAL NOTICE SHEET e Certificate TUVRhein(and Certificatess US 82140038 01 Lkeuse Holden Manatatosing Plane _..� Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Tatrepoduo.: USA•31440029 001 CllatRekreure:John Nagyvary Tntedto: Subject 2703 No. 2 (11-13-2012) Cerf&dpsodurh Module Rack Mounting System LkmunPa-Univ Model Designation: SolarMount (SM) 7 Maximum Size of PV Module: 65" long and 39.125" wide Maximum System Voltage of PV Module: 1000 VDC Maximum overcurrent protection rating of PV Module: 30 A Fire Rating: Class A when installed with Type 1 fire rated modules, Type 2 fire rated modules, ) Type 3 fire rated modules, Type 10 fire rated modules. (continued) 7 Appendix: 1, 1-4 Licensed Teat mark: Dau of Issue (daylmo/yr) 19/12/2014 TOvaheiniend ue 1WN rttWM Pn.tie.2210 actsIh WMmveN Skeet Tempt.Mama 85282.10(480)966-1165.fax PS)3,481E Ake Certificate TUVRheiniend Certificate oo. US 82140038 02 Ucmae Holder. Masnfcaring PMOL Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Teeteroiwnow: USA-3144002) 001 CHaetRefereeee:John Nagyvary Tntedte: Subject 2703 No. 2 (11-13-2012) Cenilkd Produet Module Rack Mounting System WceonFee-UWM (continued) 7 Modules Evaluated & Qualified for Mechanical Load: Trina Solar TSM-255PA05.08 Design Load: Positive = 112 psf, Negative = 50 psf Centrosolar TP6 250 SW and E 2508 Design Load: Positive = 112 psf, Negative = 50 psf TSMC Solar TS-150C2 Design Load: Positive = 35 psf, Negative = 35 psf Modules from the same series with same frame are qualified if their area is less than or equal to test module area. (continued) 7 Appendix: 1,1-4 Lkcned Test nate Date of Woe (dayhoo/yr) 19/12/2014 CADrilvtommund --- us Thy!Mariana Pit.tit 22teSwk RWevet Street Tempt M100&85222.1•1000).68-1700.PV(77S)114-8458 Certificate TUVRheinfand Cmaa US 82140038 03 LicameHeMem Ma atanoring Plent Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Teetraponns: USA. 31440023 001 Clkntkeferenee:Jahn Nagyvary Tenedto: Subject 2703 No. 2 (11-13-2012) CertlaalProdaet Module Rack Mounting System LkemePee-UMM (continued) 7 Modules Evaluated & Qualified for Electrical Bonding; AU Optronics (BenQ Solar) PM Series Canadian Solar CS5A-M, CS6P-M, CS6P-P, CSX-P Centrosolar America C-Series, E-Series ET Solar ET AC Module, ET Module Hanwha SolarOne HSL 60 Hyundai Heavy Industries MG Series Kyocera KD-F Series LG Electronics Mono Neon, Mono X Phono Solar Technology All Standard Modules (continued) 7 Appendix: 1,1-4 Licensed Test mark: Date otlwne (day/too/yr) 19/12/2014 TVVRheiniand U, Ttiv RMtrla,PR.(LC,2210 Sort Fmnw.Seat Tent Mims WW2,bM0$))966-f703.Fv an)at48459 A.a Certificate TOVRheinland Ceedaatt om US 8214003$ 04 Unase Holder. Maindsch ring Plant: Unirac Inc. Univac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Test report co.: USA 31990029 001 Mat Reference: John Nagyvary Tested to: Subject 2703 No. 2 (11-13-2012) CertifedPradud; Module Rack Mounting System Ileeme Fee-Units (continued) 7 Modules Qualified for Electrical Bonding (continued] Renesola All 60-cell Modules Sharp ND240QCJ, ND290QCS, NDQ235F4 Suniva MV Series, OPTIMUS Series SunPower AC, E-Series, Sig Black, X-Series Suntech STP XXX Trina PD0S, PA05 Yingli Panda '60, YGE 60 Yingli YGE-Z 60 Sun Edison / MEMC F-Series, R-Series SolarWorld SunModule Protect, SunModule Plus 7 Appendix: 1,1-4 Licemad Test mark[ Daae of Jesse (day/moyr) 19/lz/za14 1tVRhtins�a us WV mwn nd Gn.LLC.]1w Su0Rimini;Saw.iamb.Nieto 6ii0Z.tet(4800664 7%,H.I775)]41459 � Certificate T[UVRheintand CsMDam aa. US 82140038 45 Chex Holder. Miumadming Plant Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Tmtrepwtno.: USA-31440029 003 CIWtRdeemee:Tom Young Tandto: Subject 2703 No. 2 (11-13-2012) CerWfedPmduec Module Rack Mounting System LerenseFa-Ualt Model Designation: SolarMount (SM) 7 with additional features and more qualified modules. Max System Voltage of PV Module: 1000 VDC Max Size of PV Module: 20.8 sq. ft. surface area Max Overcurrent Protection Rating of PV Module: 30 A when using the qualified grounding lugs; 20 A when using the Enphase micro inverter EGC. Fire Rating: Class A when installed with Type 1, Type 2, Type3, or Type 10 fire rated modules. (continued) 7 Appendix: 1, 1-5 Licensed Test mark: Date of Issue (day/mo/yr) 06/11/2015 TOValwiMenE Vr NV P4ie ald Plt,tit,2210 Soon PttYwFStreet Tagg,Mvua 853$2,Tot uP)I BM-f2m.Fax 07%31481$ Certificate TOS/Rheinland Certificate no. US 82140038 06 Lkmue Holder. Mnuateemring Plant Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Teetreportne.: USA 31440029 003 C7kotReference:Tom Young Testedtm Subject 2703 No. 2 (11-13-2012) CertakMProdoet Module Rack Mounting System LkemeFee-Unit (continued) 7 More Modules Evaluated & Qualified for Mechanical Load: SunPower SPR-E20-327 Design Load: Positive = 112 psf, Negative = 50 psf Hyundai Solar HiS-M300MI & HiS-S300MI Design Load: Positive = 112 psf, Negative - 50 psf Models from the same series with same frame are qualified if their area is less than or equal to test module area. (continued) 7 Appendix: 1, 1-5 Licensed Tesst mark: Date of kae RinW06/11/2 06/11/2015 r TY1VnlreinbM Vie Rheinland PYY.LLC,2210 Sault RunnX Seim Tomo MT 85282,Td 080)90617W Pax 1rt51 Mt*Ape 1m� I'..: R`fiCecate TUVRheinland Ctrt lateaa. Certificate 14a US 82140038 07 Lkease Holders Muefacmrfag Plot Unirac Inc. Unirac Inc. 1411 Broadway NE 1411 Broadway NE Albuquerque NM 87102 Albuquerque NM 87102 USA USA Tatmmtea: USA-31440029 003 CBenRekreee:Tom Young Tntedto: Subject 2703 No. 2 (11-13-2012) CertlkdProduct Module Rack Mounting System LkeneFee-Ualte (continued) 7 More Modules Evaluated & Qualified for Electrical Bonding: Canadian Solar ELPS CS6P-MM, ELPS CS6A-MM Hyundai Heavy Industries RG Series, RW Series Panasonic VBHNxxxSA06/SA0681SA11/SA118 SolarWorld Sunmodule Pro TSMC Solar TS-150C2 GIGS 7 Appendix: 1, 1-5 Licened Test mark: Dateof tesae (daylmdyr) 06/11/2015 TUVRteinland 586 TW Rherand RTL LLC.2210 Scutt Roarveil Stns(Terme.Mara 85282.Tel aoi &,ir Fax I"5)]1{8458 L. y Planet 5 A Street Auburn MA 01501 www.brightplanetsolar.com (888) 997-4469 City / Town: \\\, c.. ),1,A Property: ti-\ IA ( 1(6 \<, Sj . Name: 0\m„s €--)ek,\Ail Question and concerns please contact: Julie Meeks Permits and Inspections Manager 888-997-4469 ext. 728 juliem@brightplanetsolar.com TS A�IJ CERTIFICATE OF LIABILITY INSURANCE OAo3rzzrzon n THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN 'THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER,AND THE CERTIFICATE HOLDER. IMPORTANT: If the certificate holder fs an ADDITIONAL INSURED,the poiicy(ies)must be endorsed. If SUBROGATION IS WAIVED,subject to the terms and conditions of the policy,certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsemengs). PRODUCER NAMVictoria Locke TACT NAME: _ ...... _ __ _. ANDREW G GORDON INCPHONE E ,,1781)659-2262 FAX,wet: AODRE53' vitt �gordenadanticinsurance.COM 306 WASHINGTON STREET —__ !WRENS) FFORoIN0 COVERAGE NAM* NORWELL MA 02061 INSURER A: AMGUARD INSURANCE CO 42390 INSURED r. ___ _ _ _. _ _ _ __ INSURER e: _ _ BRIGHT PLANET SOLAR INC wsURaec . INSURER O: SA STREET INSURERE: AUBURN MA 01501 INSURER F: COVERAGES CERTIFICATE NUMBER: 136625 REVISION NUMBER: THIS IS TO CERTIFY THAT THE POIJCTES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOMMTHSTANDING ANY REQUIREMENT,TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO M1ICH THIS CERTIFICATE MAY RE ISSUED OR MAY PERTAIN.THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES.LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS. INSR. - . � _..gI Pr CY EFF POLICY ERP I TYPE OFIXSVPANcE _. -.... M PCYXVMRER ...r TY MNOa LL LIMITS COMMERCIAL GENERAL MOUSY I ' EACHOCCURRENCE $ _t CLAIMS-MADE OCCUR • e ARES N ... F PREMISES IDA :mil _ .. MED E%PAnY one person) S _. N/A I PERSONAL BADV INJURY S GEN'L AGGREGATE LIMIT APPLES PER'. I GENERAL AGGREGATE IS _ POLICY L AIXPftd . ..J LCC PRODUCTS.COMPK,AGG I$ OTHER F..._ COMBINED SINGLE LIMIT AUTOMOBILE LIABILITY " iS. }Ea ezbnp spew NJURY War person) IS mo— IANY AUTO ALL OWNED i SCHEDULED AUTOSBODILY INJURY Pera accident) S _ HIRED NON-OWNED Autos N/A PROPERTY DAMAGE S I nmeonuros ' AUTOS IPe,a's+dMAi. I _ UMBRELLA LIAR OCCUR EACH OCCURRENCE ;F EXCESS WB CWMS.MADE, N/A I AGGREGATE b r I oco ,RETENTIONS I'. �/ -. S /N —.. WORKERS COMPENSATOR S_A41T[.1... I ERM- ANDEMPLOYERS LIA61UUfY _ -... ANYPROPRETOR,PARTNERJEXECUTIVE YIN . EL EACH ACCIDENT S 1,000,000 A OFFICERIMEMNEREXCLUDEDP WA NIA WA' R2WC767475 12/18/2016 04/04/2017 - - _ (Mandatory In NH) EL DISEASE-EA EMPLOYEE S 1,000,000 yes deco Yle Undo, OESCRIPrloN OF OPERATIONS bob* E L DISEASE POLICY LIMIT 5 1,000.000 I NMA DESCRIPTOR OF OPERATIONS I LOCATORS'VEHICLES IACORD 101,AM:Monal Remarks Schedule.may he attached R more space is nqulredl Workers'Compensation benefits will be paid to Massachusetts employees only.Pursuant to Endorsement WC 20 03 06 B.no authorization is given to pay claims for benefits to employees in states other than Massachusetts if the insured hires.or has hired those employees outside of Massachusetts. This certificate of nsurance shows the policy in force on the date that this certificate was issued(unless the expiration date on the above policy precedes the issue date of this certificate of insurance), The status of this coverage can be monitored daily by accessing the Proof of Coverage-Coverage Verification Search tool at www.mass.gov/lwd/workers-Compensation/investigations/. CERTIFICATE HOLDER CANCELLATION SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN Town of Northampton ACCORDANCE WITH THE POLICY PROVISIONS. 210 Maar Street AUTNCRIaEOREPRESEHTATVE Northampton MA 01060 Daniel M.Crow`ley.CPCU,Vice President-Residual Market-WCRIBMA (0 1988-2014 ACORD CORPORATION. All rights reserved. ACORD 25(2014/01} The AGGRO name and logo are registered marks of ACORD Qaer AIS BrightPlanetS '. iar Date: 4/15 / 011 To the Torn of WO r 1-6 rh pko n ,Mk : 1, Chas bailer ,give permission for Bright Planet Solar to submit and sign all the necessary building/electrical permit and utility interconnection paperwork for my solar system construction at3 V I I/et geld )F. Yor sett k'ir,~4 I have chosen them as my solar installation contractor. Sincerely. glitte...- X Name Y Ctrl s-lo pLe• lly U• Signature SASt.Auto"MA01501 (888)997-4469 Office of i'oasaaaer Agin & Easiness Regulation flea 't, OME IMPROVEMENT CONTRACTOR Rett 1112102 Type: EXPO 917 Supplement C BRIGHT PLANET SOL^ INC. AUL MANFRA 55 SEWAL L. AVE. ».s. BROOKLINE. MA 02446 Undersecretary Massachusetts Department of Public Safety Board of Building Regulations and Standards License:CS-109128 Construction Supervisor PAUL MANWRA 36 EVERGREEN STREET 11111 SAUGUS MA 01906 rel Expiration: Commissioner 09/2012019 >�/ECTOR E rl p I rl E E R 5 VSE Project Number:01932-0717-171 March 21,2017 Brieht Planet Solar ATTENTION: Mikey Heinz 69 Milk St..Suite 308 Westborough,MA 01581 REFERENCE: Christopher Bakker Residence:304 Hatfield Street,Northampton,MA 01060 Solar Array Installation To Whom It May Concern: Based upon our review, it is our conclusion that the installation of the solar array on this existing roof will not adversly affect this structure. It is our understanding that the structural components of the existing roof framing are in good condition and free of damage. The design of the solar panel racking(mounts,rails,etc.)is by the manufacturer or contractor. Solar module mounting hardware is engineered by the manufacturer. Vector Structural Engineers has relied on site survey information (photographs,measurements&diagrams)provided by the installer for roof framing information. Resin.] Parameters Code:Massachusetts State Building Code(780 CMR Chapter 16, 8th Edition(2009 IBC)) Occupancy Category:II Design wind speed:90 mph (3-sec gust)per ASCE 7-05 Wind exposure category:C Ground snow load: 40 psf Existine Roof Structure Roof structure:2x6 rafters @ 16"O.C. Roofing Material: asphalt shingles Roof slope:35° Connection to Roof Mounting connection:(1)5/16" Lag Screw w/min.2.5" embedment at max.48"O.C. Conclusions Our conclusion regarding the adequacy of the existing roof is based on the fact that the additional weight of the solar array is 3 psf or less. In the area of the solar array,other live loads will not be present or will be greatly reduced. The member forces in the area of the solar panels are not increased by more than 5%; thus, the stresses of the structural elements are not increased by more than 5%. Therefore, the requirements of Section 3403.3 of the Massachusetts State Building Code (780 CMR Chapter 16,8th Edition(2009 IBC))are met and the structure is permitted to remain unaltered. The solar array will be flush-mounted (no more than 6" above the roof surface) and parallel to the roof surface. Thus, we conclude that any additional wind loading on the structure related to the addition of the proposed solar array is negligible. The attached calculations verify the capacity of the connections of the solar array to the existing roof against wind (uplift), the governing load case.The connections to the existing roof shall be spaced at 48"maximum. 651 W. Galena Park Blvd. /Draper, UT 84020/T(801) 990-1775/F (801) 990-1776/www.vectorse.com VSE Project Number: U1932-0717-171 _ VECTOR Christopher Bakker Residence E rn E I r1 E E R 9 3/21/2017 Limitations Installation of the solar panels must be performed in accordance with manufacturer recomendations. All work performed must be in accordance with accepted industry-wide methods and applicable safety standards. The contractor shall notify Vector Structural Engineerine, LLC should any damage,deterioration or discrepancies between the as-built condition of the structure and the condition described in this letter be found. Particular attention must be paid to the maximum allowable spacing of connections and the location of solar panels relative to roof edges. Connections to existing roof framing must be staggered so as not to overload any existing structural member, except at array ends. The use of solar panel support span tables provided by others is allowed only where the building type,site conditions, site-specific design parameters, and solar panel configuration match the description of the span tables. Electrical engineering is the responsibility of others. Waterproofing around the roof penetrations is the responsibility of others. Vector Structural Engineering assumes no responsibility for improper installation of the solar array. VECTOR STRUCTURAL ENGINEERING.LLC en ROGER;. . / VII >` 1 FIS A .. Nr;• , / I 03/21/2017 Roger Alward], P.E. MA License:47740-Expires: 06/30/2018 Principal Enclosures RTA/haz 651 W. Galena Park Blvd./ Draper, UT 84020/T(801) 990-1775/ F(801) 990-1776/www.vectorse.com �/ ECTOR JOB NO.: SUBJECT: WIND : WIND PRESSURE E fl G I rl E E R S PROJECT: Christopher Bakker Residence Components and Cladding Wind Calculations Label: 5 .x)11 Note: Calculations per ASCE 7-05 SITE-SPECIFIC WIND PARAMETERS: Basic Wind Speed [mph]: 90 Notes: Exposure Category: C Occupancy Category: II �, ,, ` "fix Importance Factor, I: 1.0 s "-ra. _� ADDITIONAL INPUT& CALCULATIONS: Height of Roof, h [ft]: i , ] (Approximate) Comp/Cladding Location: � .� Enclosure Classification ,,•]],',...;;;Y-•]:.r:-,. Zone 1 GCp , .i] '; Figure 6-110 (enter largest abs. value) Zone 2 GC 's p t :J (enter largest abs. value) Zone 3 GCp �: (enter largest abs. value) a: 9.5 Table 6-2 zg [ft]: 900 Table 6-2 Kh: 0.95 Table 6-3 KSI: 1 Equation 6-3 Kd: 0.85 Table 6-4 Velocity Pressure, qh [psf]: 16.7 Equation 6-15 GCp;: 0 Figure 6-5 (largest abs. value) OUTPUT: p=gh[(GCp)—(GCp,) Equation 6-4 Zone 1 Pressure, p [psf]: 16.7 psf(1.0 W, Interior Zones*) Zone 2 Pressure, p [psf]: 20.0 psf(1.0 W, End Zones*) Zone 3 Pressure, p [psf]: 20.0 psf(1.0 W, Corner Zones*within a) (a= 3 ft) )I/ E C T O RE fl G I rl E E R S JOB NO.: U1932-0717-171 SUBJECT: CONNECTION PROJECT: Christopher Bakker Residence Lag Screw Connection Capacity: Demand: Lag Screw Size [in]. ' 5t1t6] Cd. 1.6 NDS Table 2.3.2 Pressure Max Max. Trib. Max. Uplift (1.0 Wind) Spacing Area Force Embedment [in] SI (psi) (ft) (ifs) (lbs) Grade _ t}.42). , -.1 Zone Capacity [lbs/in] ]..11NDS Table 12.2A 1 16 7 ,1t04]*, ` 1 1.0 183 t . Number of Screws: .C r 4+ 2 200 11.0 220 PryingCoefficient: 1.4 3 20.0 ,; 1H 8.3 165 Total Capacity [lbs]: 586 Demand< Capacity: CONNECTION OKAY N/ E CTO RJOB NO.: U1932-0717-171 SUBJECT: GRAVITY LOADS E Tie I n E E R E PROJECT: Christopher Bakker Residence CALCULATE ESTIMATED GRAVITY LOADS Increase due to Original DEAD LOAD (D) pitch loading Roof Pitch/12 E`=__ Asphalt Shingles 2.4 1.22 2.0 psf 1/2" Plywood 1.2 1.22 1.0 psf Framing 3.0 psf Insulation 0.0 psf 1/2" Gypsum Clg. 0.0 psf M, E & Misc 0.0 psf DL 7 psf PV Array DL 3 psf ROOF LIVE LOAD (Lr) Existing Design Roof Live Load [psf] 20 ASCE 7-05, Table 4-1 Roof Live Load With PV Array [psf] i$ + 0 w/Solar Panel SNOW LOAD (9): Existing Array Snow Ground Load, pg [psf]: Roof Slope [°]: 35 35 Snow Ground Load, pg [psf]: s � „ • ASCE 7-05, Section 7.2 Terrain Category: ASCE 7-05,Table 7-2 Exposure of Roof: . + :,z. ASCE 7-05, Table 7-2 Exposure Factor, Ce: 0.9 0.9 ASCE 7-05, Table 7-2 Thermal Factor, C,: ASCE 7-05, Table 7-3 Risk Category: ASCE 7-05, Table 1-1 Importance Factor, Is: 1.0 1.0 ASCE 7-05, Table 7-4 Flat Roof Snow Load, p,[psf]: 28 28 ASCE 7-05, Equation 7-1 Minimum Roof Snow Load, p, [psf]: 0 0 ASCE 7-05, Section 7.3.4 Unobstructed Slippery Surface? .-Ro s;e ASCE 7-05, Section 7.4 Slope Factor Figure: Fi.ure 7-2b Fi.ure 7-2b ASCE 7-05, Section 7.4 Roof Slope Factor, Cs: 1.00 0.58 ASCE 7-05, Figure 7-2 Sloped Roof Snow Load, pe [psf]: 28 16 ASCE 7-05, Equation 7-2 Design Snow Load, S [psf]: 28 16 932-0717-171 ��/ ECTOR JOB NO.: L ADCOMPAR SUBJECT: LOAD COMPARISON E Il G I n E E RS PROJECT: Christopher Bakker Residence Summary of Loads Existing With PV Array D[psf] 7 10 Lr[psf] 20 16 S [pfsf] 28 16 Maximum Gravity Loads: Existing With PV Array D+ L,[psf] 27 26 ASCE 7-05,Section 2.4.1 D+S[psf] 34 26 ASCE 7-05,Section 2.4.1 Maximum Gravity Load [psf]: 34 26 Ratio Proposed Loading to Current Loading: 75% OK The gravity loads in the area of the solar array are decreased;thus,the stresses of the structural elements are decreased.Therefore,the requirements of Section 3403.3 of the Massachusetts State Building Code(780 CMR Chapter 16,8th Edition(2009 IBC))